| 1 | Supply and install hi wall split units indoor/outdoor completewith minimum 5 star rating and EER 3.2.of capacity 2 TR as showncomplete all as perspecified and as directed.Note: 1 Making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates. |
| 2 | Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 32 Amp complete all as specified and directed by Engineer-in-charge. |
| 3 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed by Engineer-in-charge. |
| 4 | M&L for Sub main wiring complete with non-metallic rigid PVC insulated fire retardant grade unsheathed 1100V grade multistranded copper conductor cable 2 run of4 Sqmm single core confirming to IS-694 with copper conductor drawn through PVC casing capping/conduit heavy duty and accessories in walls, roof and floors along with 1 run of4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete including chase cutting by cutter concealed in PVC conduit all as specified and as directed by Engineer-in-Charge. |
| 5 | M&L for earthing with electrode should be 2 No’s Copper Plate of size 90cmx60cmx5mm inter connected with 50 X 6 mm copper strip of length 1.5 mtrs and in center shall be 32 X 6 mm copper strip of 3 meter with suitable brass nut bolts and brazing for lower resistance. Alternate layers of Soil & Curec+ or equilent (03 kgs bag x2 ) ; make as per IEEE 80 2000 ,Clause 14.5 D, Maintenance Free Earthing System to give Earthing Resistance value of ≤ 1Ω. The soil shall be mixed with backfill CURENITE or equivalent (25-kgs x 2bags). Copper Electrode’s should be solid rod and surrounded with highly conductive and non corrosive nature (pH value certified) & covered with Poly plastic Earth Pit Cover in and including construction of PCC boundry with specified colour coding around the poly plastic pit cover. Further electrodes of GI pipe atleast 30mm dia shall be interconnected in parallel fashion incase low ohmage is not achievable poly plasticc enclosure shall be provided. |
| 6 | S&F in replacement of factory made epoxy polyster powder coated distribution board SPN 6 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified and confirming to IS: 8623.Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. |
| 7 | Supply and install Flame proof air cooled,GI powder coated outer bodyunits indoor/outdoor complete with cordless remote control unitwith minimum 5 star rating and EER 3.2.of capacity 1.5 TR as shown Make:- Friz Cool Twin Compressor-single speed Type :- floor mounted Power input : 220V/50 Hz/ Single phase or equivalent as approved by GE.Note: 1) Making hole in wall(included Lintel Beam), insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates. |
| 8 | Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 32 Amp complete all as specified and directed by Engineer-in-charge. |
| 9 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed by Engineer-in-charge. |
| 10 | Supply and fixdehumidifier continuous operating complete, Power rated consumption660W(30 degree centigrate 80% RH) *Airflow:-250M3/H*Air Flow(Dry Mode): 380M3/H *Noise Level:50DB(A) *Moisture Removal (L/Day):35L/Day (26.7 Degree Centigrade 60% RH) 50L/Day (30 Degree C 80% RH*Water tank Cap:-5L*Refrigerant:-R410 |
| 11 | S&F in repalcement of MCB SP 63 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge. |
| 12 | Supply and fixing in replacement of Automatic transfer switch of capacity 200 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/ manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge. |
| 13 | S&F stop valve cast copper alloychromium plated high pressure, fancy type screwed on both ends with iron pipe or unions, 15 mm bore fancy type all as specified and directed. |
| 14 | S/F waste fittings brass Chromium Plated for glazed ware sinks basins etc with long screwed shanks and fly nuts flange end embedded in red lead cement and other end fixed of 32mm size all as specified and directed. |
| 15 | S&Fof 32 mm bore of pipe low density (LDPE) of pressure rating 6 kg/ sqcm fixed to wall or floor etc including fittings complete all as specified and as directed. |
| 16 | M&L for PVC (SWR) floor trap of 75mm dia, plain with grating including jointing withsolvent cement all as specified and directed. |
| 17 | S&F 75 mm bore PVC (SWR) rain water pipes of single socketed in any length with rubber ring joints, jointed with solvent laid in trenches or in floors with matching PVC SWR rings including cutting holes and making good the disturbed portion with PCC 1:2:4, type B0 complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply and fixing framed work such as grills, gratings, tank cover, drain covers made of angle,for monkey proofing, channel, bars and sheets etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 19 | Material and labour for preparation of new steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a one coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 20 | Supply and fixing 500 litre capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball PTMT, valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimum weight 210 gram complete all as specified and as directed. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortarbedding (but not backing) , removing serviceable tiles to store and rubbish off the permises complete all as specified and directed. |
| 22 | M&L Glazed ceramic coloured tiles of size450x300x7mm thick on vertical surfaceset and jointed in neat cement slurry and pointed in white or colour cement to match the shade etc including 10mm thick rendering in CM (1:4) complete all as specified and directed . |
| 23 | S&F SS 304 Grade Wall Mounted safety Eye wash Kit / Fountain /Shower with all connected fittings like SS Sprinklers, SS Nozzels, SS Push plate/ liver,Waste pipe etc.As per BIS 10592:1982 Make : SoleSafe or equivalent as approved by GE. |
| 24 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed |
| 25 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed |
| 26 | Taking down or up 15 mm bore galvanised iron tubing and connection including cleaning for refixing or removal all as specified |
| 27 | All as per item No 30 here in before but 20 mm bore |
| 28 | Demolition of concrete is reinforced (Reinforcement cut as required to faciliate demolition)of any descrition and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge All dismantling/demolished material removed from MOD land completely.Rate ofremoval outside side from MoD land deemed to be included in the same item. |
| 29 | Taking down cement plaster including raking out joints hacking for key and scrubbing down with water complete as specified and directed. |
| 30 | Taking down rain water pipe and eaves gutters(any size and pattern) including all fittings heads shoes bends swan necks etccomplete all as specified and as directed. |
| 31 | Demolition of brick work or stone/boulder masonry, built in cement mortar incl. all quoins arches, pillars etc. but excluding ashlar facing, dressed stone work andprecast concrete articles, complete all as specified and directed. |
| 32 | M&L for Precast RCC slab, landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs,mangers, shelves type B1(1:2:4)and similar articles with plain faces set in cement mortar 1:4 all as spfd and directed |
| 33 | M&L TMT steel bars 10mm dia and over cut to length bent shape required, including cranking bending binding with mild steel wire (annealed) not less than 0.9mm dia quality conforming to relevant IS complete all as specified. |
| 34 | S & F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified. |
| 35 | All as per serial item 38 here in before but 20 mm bore |
| 36 | S&F factory made white color 3-Track UPVC sliding window are made of UPVC extruded profile with wall thickness of (2.3mm to 2.5mm), window profile with hollow section with multi chamber, Frame(91mmx47mm), sliding glazed sash (60mmx34mm), 1 No SS mesh sash (60mmx34mm), sliding interlock (one vertical length in each shutter) (38.4mm x29.5mm), incl glazed through 5mm thick glasswith glazing bead (18mmx16mm) will be metered cut and fusion weldedat all corners, including driling of holesfor fixing hardware with 2 Nos touch lock, 06 Nos roller wheel and drainage of water etc making arragementof fixing of hardware, EPDM gasket(1.2 mm to 3mm) thick, GI of (1.2mm tto 1.5mm) thick in frame, 2 sliding glass sash and 1 sliding mesh sash to be inserted in required profile , frame will be fixed by wall with 8mmx100mm long fasteners complete fittings and fixtures as per manufacture\"s specificationand direction of Engr-in-Charge. Note : Quoted rate included all above complete descritption. |
| 37 | M&L for 15mm thickrendering in CM 1:4 on other than fair faces of brick or concrete surfaces finished even and smooth without using extra cementall as spfd and directed. |
| 38 | S & F cast iron floor trap with graating of 100 mm size including jointing to waste pipe with cement joints etc complete as directed |
| 39 | S&F in repairvitreous china wash basin under counter oval type (536mm X 435 mm) , white, flat back, size 550 mm x 400 mm fixed over graniteand including cp waste coupling, waste fitting and union complete all as specified and as directed. |
| 40 | S&Fdeck mount type pillar tap mixercast copper alloyfor iron pipe pipe and fixed with 15mm bore in repairs all as directed. |
| 41 | S & F32mm dia waste fitting brass chromium plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 42 | S & F in repair PVC connection 15 mm size with CP nuts of length 600 mm etccomplete all as specified. |
| 43 | S&F angle valves CP screwed down high pressureof fancy type chromium plated screwed both ends for iron pipe or for union and fixed with 15mm bore in repairs |
| 44 | S&Ftwo way angle cock CP screwed down high pressureof fancy type chromium plated screwed both ends for iron pipe or for union and fixed with 15mm bore in repairs |
| 45 | S&F in repair of CP soap tray fixed to walls with rubber plugs complete all as specified and directed. |
| 46 | S&F in repair brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed. |
| 47 | S & F 110 mm bore of pipe PVC (SWR) pipes double socket in any length with rubber ring joint laid in trenches or floor as directed |
| 48 | S&F in repair colour venetian blinds of 100mm widthof stripwith frame and fittings fixtures complete all as sfpd and directed |
| 49 | M&L for Mirror polishing on Old Kota stonework where ever required to give high gloss finish complete all as spfd and directed |
| 50 | M&L brick work in CM (1:6) with sub class ‘B’ bricks straight or curved on plane exc 6m mean readius,used in drain, boundary wall,compound wall complete all as specified and directed by engr in charge. |
| 51 | M&L for 20mm thick granite (of any type)work (table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like over 15mm thick screed bed in CM 1:6including pointing in white cement 1:2using marble dust with admixture of pigment to match with shade of graniteetccomplete all as specified. |
| 52 | Rounding to the edge of stone slabs on edge such as cooking platform |
| 53 | M & L for preparation of new plastered surfaces of walls and applying two coat of Oil Bound distemper over a coat of 1mm thick wall care putty on wall, complete all as specified. |
| 54 | M&L in repairfor fixing of Aluminium composite panel of 3mm thickfixed on wall as wall paneling with making grid of 1200mm X1200mm of MS square pipe of size 25mmx25mm of 4mm thick fixed complete all as specified and directed by Engr-in-charge. Note : Pattern/design and color shall be approved by Accepting Officer. No Extra shall claim by the contractor for same. Note : Necessary scafolding rate deemed to be included in same item |
| 55 | M & L preparation of old painted surface of steel and iron work of any description over 10 cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and as directed. |