| Sl. No. | Item Description |
| 1 | Taking down carefully aluminium/copper point wiring on battenor in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete,including fixture and fitting such as switches,ceiling roses,pendents,regulators,sockets,light fitting etc.removing materials to storefor keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making goodthe disturbedsurfaces of walls, Floors, ceilings etc. |
| 2 | Taking down carefullyexisting wooden board , Main switch, MCB DB boxes, cut out,etc of any size anycapacity fromboards completeall as specified and as directed. |
| 3 | Taking down carefullyexistingTPN boxes of any size anycapacity fromboards completeall as specified and as directed. |
| 4 | Taking down carefully sub main wiring from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed. |
| 5 | Taking down carefully service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed. |
| 6 | M & L for Modular concealed point wiringone lightcontrolled by one modular switch with PVC insulated and unsheathed flame retardant Low Smoke(FRL-SH) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, withmodular MS terminal boxes (not less than 1.6mm thick) including earth dollywith modular frame plates with matching cover plates all modules including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed for the following. Note : Modular matching cover frame pates of defferent sizes areshall be measured separately. |
| 7 | All as per Srl item No.6 above but one fan / Exhaust fan point controlled by one modular switch & modular regulator. |
| 8 | All as per Srl item No.6 above but one 3 pin10 Amp socket outlet point controlled by one modular switch on independent board. |
| 9 | All as per Srl item No.6 above but one 3 pin10 Amp socket outlet point controlled by onemodular switch on same board. |
| 10 | All as per Srl item No.6 above but one bell / buzzer point controlled by one modular bell switch |
| 11 | Description all as per item No 6 above but power point with modular MS Terminal Box (not less than 1.6mm thick) complete with PVC insulated and unsheathedflame retardant Low Smoke(FRL-SH) cable of 2.5 sqmm single core multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with for 3/6 pin 15 Amp modular socket outlet 2 module controlled by one modular switch on independent board with and including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. |
| 12 | M & Lconcealed point wiring for one lightcontrolled by one switch complete with PVC insulated and unsheathedflame retardant Low Smoke(FRL-SH) ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.0mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dollywith 3 mm thick plastic laminated sheet in top cover including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed |
| 13 | All as per Srl item No 12 above but one fan / Exhaust fan point controlled by one switch |
| 14 | All as per Srl item No.12 above but one 3 pin 10 Amp socket outlet point controlled by one switch on independent board. |
| 15 | All as per Srl item No.12 above but one 3 pin10 Amp socket outlet point controlled by one switch on same board |
| 16 | All as per Srl item No.12 above but one bell / buzzer point controlled by onebell switch |
| 17 | Description all as per item No 12 above butfor concealed power point wiring withMS Terminal Box (Not less than 1.0 mm thick) complete with PVC insulated and unsheathedflame retardant Low Smoke(FRL-SH) cable of 2.5 sqmm single core multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with for 3/6 pin 15 Amp socket outlet controlled by oneswitch on independent board with and including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. |
| 18 | M&L for Modular Casing Caping point wiring one lightcontrolled by one modular switch with PVC insulated and unsheathed flame retardant Low Smoke(FRL-SH) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and includingPVC casing caping, with modular MS terminal boxes (not less than 1.6 mm thick) including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed . Note : Modular matching cover frame pates of defferent sizes areshall be measured separately. |
| 19 | All as per Srl item No.18 above but one fan / Exhaust fan point controlled by one modular switch . |
| 20 | All as per Srl item No.18 above but one 3 pin 10 Amp socket outlet point controlled by one modular switchon independent board. |
| 21 | All as per Srl item No.18 above but one 3 pin10 Amp socket outlet point controlled by one modular switch on same board. |
| 22 | All as per Srl item No.18 above but one bell / buzzer point controlled by one modularbell switch |
| 23 | Description all as per item No 18 above but for power point using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed,flame retardant Low Smoke(FRL-SH)cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with PVC Casing Caping and including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. |
| 24 | M&L PVC casing caping point wiring for one lightcontrolled by oneswitch complete with PVC insulated and unsheathed flame retardant Low Smoke(FRL-SH)cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and includingPVC casing caping, withMS terminal boxes (not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dollywith3mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed |
| 25 | All as per Srl item No.24 above but one fan / Exhaust fan point controlled by one switch . |
| 26 | All as per Srl item No.24 above but one 3 pin10 Amp socket outlet point controlled by oneswitch on independent board. |
| 27 | All as per Srl item No.24 above but one 3pin10 Amp socket outlet point controlled by oneswitch on same board. |
| 28 | All as per Srl item No.24 above but one bell / buzzer point controlled by onebell switch |
| 29 | Description all as per item No 24 above but for power point using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke(FRL-SH)cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with PVC Casing Caping and including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. |
| 30 | M&L for point wiring one light point controlled by one switch with PVC insulated and unsheathed, flame retardant Low Smoke(FRL-SH) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with stranded copper conductor single core in and including rigid PVC surface conduit not less than 20 mm dia, clip, with suitable MS terminal boxes( not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved colours including 1.50 sqmm green stranded copper conductor as continuous earth wire with all accessories including lugs required, complete all as specified and as directed |
| 31 | All as per Srl item No 30 above but one fan / Exhaust fan point controlled by one switch & regulator. |
| 32 | All as per Srl item No.30 above but one 3 pin 10 Amp socket outlet point controlled by one switch on independent board . |
| 33 | All asper Srl item no 30 above but one 3 pin 10 Amp socket outlet point controlled by one switch on same board . |
| 34 | All as per Srl item No 30 above but one light point controlled by two 2-way switch . |
| 35 | All as per Srl item No.30 above but one bell / buzzer point controlled by onebell switch |
| 36 | Description all as per item No 30 above but for power point using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke(FRL-SH) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. |
| 37 | M&L for Modular PVC surface conduitpoint wiring one lightcontrolled by one modular switch with PVC insulated and unsheathed, flame retardant Low Smoke(FRL-SH) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with stranded copper conductor single core in and including rigid PVC surface conduit not less than 20 mm dia, clip, with suitable MS terminal boxes( not less than 1.6 mm thick)including earth dolly with modular frame plates with matching cover platesincluding 1.50 sqmm green stranded copper conductor as continuous earth wire with all accessories including lugs required, complete all as specified and as directed . Note : Modular matching cover frame pates of defferent sizes areshall be measured separately. |
| 38 | All as per Srl item No.37 above but one fan / Exhaust fan point controlled by one modular switch &modular regulator . |
| 39 | All as per Srl item No.37 above but one 3 pin10 Amp socket outlet point controlled by one modular switch on independent board . |
| 40 | All as per Srl item No.37 above but one 3 pin10 Amp socket outlet point controlled by one modular switch on same board . |
| 41 | All as per Srl item No.37 above but one bell / buzzer point controlled by one modularbell switch |
| 42 | Description all as per item No 37 above but for power point using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke(FRL-SH) cable for 3/6 pin 15 Amp socket outlet controlled by one modular switch on independent board with and including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. |
| 43 | S & F modular switch one way 10 Amp,1 module complete all as specified and asdirected . |
| 44 | S&F modular socket 10 Amp,2/3 pin combined 2 modulecomplete all as specified and asdirected. |
| 45 | S & F modular switch one way 20 Amp,1 module complete all as specified and asdirected. |
| 46 | S & F modular socket 10 Amp,/20 Amp,2/3 pin combined 2 modulecomplete all as specified and asdirected. |
| 47 | S & Fmodular Fan Regulator fan socket type regulator,2 module complete all as specified as directed. |
| 48 | S & Fmodular Fan Regulator fan switch type regulator,2 module complete all as specified as directed. |
| 49 | S&F modular bell push 10 Amp ,1 module complete all as specified and asdirected. |
| 50 | S&F Modular matching cover frame plates for 1/2 modules complete all as specified and as directed. |
| 51 | S&F Modular matching cover frame plates for 3 modules complete all as specified and as directed. |
| 52 | S&F Modularmatching cover frame plates for 4 modulescomplete all as specified and as directed. |
| 53 | S&F Modularmatching cover frame plates for 6 modules complete all as specified and as directed. |
| 54 | S&F Modularmatching cover frame plates for 8 modules complete all as specified and as directed. |
| 55 | S&F Modular matching cover frame plates for 12 modulescomplete all as specified and as directed. |
| 56 | S&F Modular matching blanker complete all as specified and as directed. |
| 57 | S&F control switch piano ( PC )flush button type 10 Amp single pole one waycomplete all as specified and asdirected. |
| 58 | S&F control socket outlet3 pin, 10 Amp (PC )flush type complete all as specified and asdirected. |
| 59 | S&F control switch piano (PC ) flush button type 20 Amp single pole one way complete all as specified and asdirected. |
| 60 | S&F control socket outlet2in1, 3 pin, 5 Amp and 20 Amp(PC ) flush type complete all as specified and asdirected. |
| 61 | S&F control switch piano (PC ) flush button type 6 Amp single pole 2 way complete all as specified and asdirected. |
| 62 | S&F control bell switch piano (PC ) flush button type 6 Amp single pole complete all as specified and asdirected. |
| 63 | S & F delux Fan Regulator electronic rotary, socket type 240 Volt50 Hz complete all as specified as directed. |
| 64 | S & F delux Fan Regulator electronic rotary, switch type 240 Volt50 Hz complete all as specified as directed. |
| 65 | S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittingscomplete all as specified as directed. |
| 66 | S & F 9W LED lamp B22,CDL,Lumen output 850 Im, 3 Star rating 6500 K, 56 mm dia complete all as specified as directed. |
| 67 | S & F 9W LED lamp E27,CDL(warm white),Lumen output 850 Im, 3 Star rating 3000 K, 56 mm dia complete all as specified as directed. |
| 68 | S&F ceiling rose,surface bakelite 65 x50mm three terminals completeall as specified and asdirected. |
| 69 | S&F MCB DB, sheet metal enclosures double door SPN 4 way with 100 Amp rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed. |
| 70 | S&F MCB DB, sheet metal enclosures double door SPN 8 way with 100 Amp rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed. |
| 71 | S&F MCB DB, sheet metal enclosures double door SPN 12 way with 100 Amp rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed. |
| 72 | S & F sheet metal enclosure single door concealed suitable for distribution boards for MCB single pole and neutral240V 2 way without bus bar complete all as specified and as directed. |
| 73 | S&F MCB DP 32 Amp 240 V ,10KA ,\"C\" series,complete all as specified and as directed with copper lugs complete all as specified and directed . |
| 74 | S&F MCB DP 40-63 Amp 240 V ,10KA ,\"C\" series,complete all as specified and as directed with copper lugs complete all as specified and directed . |
| 75 | S&F, MCB SPN 40-63 Amps, 240 volts \"C\" series 10 KA ,including connection with suitable size copper lugs complete all as specified and directed. |
| 76 | S&F MCB single pole 6 to 32Amps 240 V,10KA, \"C\" series,complete all as specified and as directed with copper lugs complete all as specified and directed. |
| 77 | S&F VTPN DB-DPX Box 4 way double door with provision for DPX MCCBs as out going no MCB\"s 8+12 complete all as specified and as directed. |
| 78 | S&F MCCB 100 Amps,4 pole,415volts,3 phase,50HZ, having 16 KA rupturing capacity, 415 volts with electronic trip arrangment and setting screw upto 70- 100% including making connection with excisting cable with connection and materials like copper strips,lugs,nut & bolts etc. complete all as specified and as directed. |
| 79 | S & F in replacement/new decorative wall light fixture( FLORET ) type made of polycarbonate , including LED Bulb 10 Watts complete all as specified as directed . |
| 80 | S&FLED lights fitting 22 Watt, 220V, decorative ultra slim LED tube light polycarbonate body connecting up to from existing/ new ceiling rose complete all as specified and directed |
| 81 | S&F 36 W2 feet X 2 feet LED Ultra mordern recess mounting luminaire suitable for armstrong/ grid ceiling in MS housing with high brightness LEDs incl wiring upto and terminating into existing / new ceiling rose complete all as specified and directed . |
| 82 | Supply and fix in replacement/new, 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection, one twin core cable flat or circular of size 16 Sq mm to be connected to existingMCB box / Main switches complete all as specified as dircted. |
| 83 | S & F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection, one twin core cable flat or circular of size 10 Sq mm to be connected to existingMCB box / Main switches complete all as specified as dircted. |
| 84 | S & F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection, one twin core cable flat or circular of size 6 Sq mm to be connected to existingMCB box / Main switches complete all as specified as dircted. |
| 85 | S & F 15 Watt LED lamp ( warm white)E27,CDL,Lumen output, 3 Star rating, 1425 Im, 3000 K, complete all as specified as directed. |
| 86 | S&F 10 W LED Polymer Bulkhead luminaire energy efficient suitable for wall , ennvironmental friendly,ulta modern ,energy saving, surface mounted LED luminaire complete all as specified and as directed. |
| 87 | S&F 50 W LED 6000K exclusive innovative designed, long life versatile pressure dia-cast aluminiumflood light luminaire with high power LED as light source. incl wiring upto and terminating into existing ceiling rose complete all as specified and as directed. |
| 88 | S&F 100 W LED 6000K exclusive innovative designed, long life versatile pressure dia-cast aluminiumflood light luminaire with high power LED as light source. incl wiring upto and terminating into existing ceiling rose complete all as specified and as directed. |
| 89 | Taking out exiting unserviciable under ground cables carefully of any size and type and in any position in trenches / floors / on poles complete all as specified and directed. |
| 90 | S&F laying, fixing in trenches/ on pole wall or passing through pipe,PVC under ground cable,LT 1100 voltsgrade heavy duty cable aluminium conductor armouredwith galvanised steel wire or tape and ovrhall PVC sheathed of size 16 sqmm 4 corecomplete all as directed. |
| 91 | S&F laying, fixing in trenches/ on pole wall or passing through pipe,PVC under ground cable,LT 1100 voltsgrade heavy duty cable aluminium conductor armouredwith galvanised steel wire or tape and ovrhall PVC sheathed of size 35 sqmm 3.5 corecomplete all as directed. |
| 92 | S&F laying, fixing in trenches/ on pole wall or passing through pipe,PVC under ground cable,LT 1100 voltsgrade heavy duty cable aluminium conductor armouredwith galvanised steel wire or tape and ovrhall PVC sheathed of size 10 sqmm 2 corecomplete all as directed. |
| 93 | Excavationin trenches in any type of soil not exe 1.5 mtrs wideand not exe 1.5 mtr in depth for laying of pipe/cables etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed . |
| 94 | Returning filling in incl spreading, leveling, watering and well ramming in layers not exe 25 cms in hard densesoil , soft disintegrated rock complete all as specified and directed. |
| 95 | Removing surplus excavatedsoil to a distance not exe 50 mtr and depositing where directed ata level not exe 1.5 mtr above the starting pointcomplete all as specified and directed . |
| 96 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. |
| 97 | Supplying and laying GI pipe 40/32 mm bore light grade laid under plinth , ground or fixed along walls for protection of cables complete including necessary fixing arrangements such as MS clamps / hooks, nuts, bolts,washers completeall as specified and directed |
| 98 | S&F in replacement/new LED building security/ street light fitting 1 X45 W LED energy saving & environmental freindly long life versatile pressure die castaluminiumroadway luminaire with high power LEDs as light source and electronic driver suitable for wall/ pole including connection with 1.5 sqmm two single core PVC insulated and PVC sheathed cable stranded Copper conductor upto ceiling rose and fixing on walls/pole complete as specifiedand as directed. |
| 99 | S&F LED tube light fitting 1x20 Watt,6500 K 220V, decorative ultra slimLED tube light polycarbonate body connecting up to existing/new celing rose of suitable size from ceiling rose complete all as specified and directed |
| 100 | S & F decorative wall light fixture( FLORET ) type made of polycarbonate , including LED Bulb 10 Watts complete all as specified as directed . |
| 101 | S & F Miniature circuit breaker C Curve Three pole Neautral link 63 Amp complete all as specified as directed . |
| 102 | S&F LED building security/ street light fitting 1 X 36 W LED energy saving & environmental freindly long life versatile pressure die castaluminium I roadway luminaire with high power LEDs as light source and electronic driver suitable for pole , 32 mm dia light grade tube bracket, bend to shape 1.80 mtr length with two nos clamp of size 32mm x 3 mm with nut, bolts, washers etc including connection with 1.5 sqmm two single core PVC insulated and PVC sheathed cable stranded Copper conductor upto ceiling rose and fixing on walls/pole complete as specifiedand as directed. |
| 103 | S&F 42 W2 feet X 2 feetPLUTO NEO PANEL LED Ultra mordern recess mounting luminaire suitable for armstrong/ grid ceiling in MS housing with high brightness LEDs incl wiring upto and terminating into existing / new ceiling rose complete all as specified and directed . |
| 104 | S&F 36 W2 feet X 2 feetwarm white pannel Ultra mordern recess mounting luminaire suitable for armstrong/ grid ceiling in MS housing with high brightness LEDs incl wiring upto and terminating into existing / new ceiling rose complete all as specified and directed . |
| 105 | S&F Warm White LED tube light fitting 1x20 Watt,220V, 3000 K decorative ultra slimLED tube light polycarbonate body connecting up to existing/new celing rose of suitable size from ceiling rose complete all as specified and directed |
| 106 | S&FLED tube light fitting 1x24 Watt,220V, decorative ultra slimLED tube light polycarbonate body connecting up to existing/new celing rose of suitable size from ceiling rose complete all as specified and directed |
| 107 | S&F in repair/ replacement of LED curve stone light as per existing sample or user requirement complete all specified and directed. |
| 108 | S&F MCB protected power unit include MCB SP 16A to 25 A ,220V,50 Hz Complete all as specified and directed. |
| 109 | S&F MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 32A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. |
| 110 | S&F in repair for sub main wiring with PVC insulated, unsheathed 2 single core cable 1100 volts grade withcopperconductor of size 10 sq mm (Nominal area) multi stranded drawn into newconduit dia 20mm with and including 10 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately. |
| 111 | S&F in repair for sub main wiring with PVC insulated, unsheathed 2 single core cable 1100 volts grade withcopperconductor of size 6 sq mm (Nominal area) multi stranded drawn into new conduitdia 20mm with and including 6 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately. |
| 112 | S&F in repair for sub main wiring with PVC insulated, unsheathed 2 single core cable 1100 volts grade withcopperconductor of size 4 sq mm (Nominal area) multi stranded drawn into new conduit dia 20mm with and including 4 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately. |
| 113 | S&F in repair/replacement sub main wiring with taking down old U/S submain wiring PVC insulated, unsheathed 2 single core cable FRLS-H,1100 volts grade with copper conductor of size 2.5 sq mm (Nominal area) multi stranded drawn into conduit not less than 20 mm diawith and including 2.5 sqmm green multistranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured and paid separately. |
| 114 | S & FAC Static Digital single phase Multi function KWH meter with meter cover box current rating 5 to 30 Amps, 2 wire 240 Volts, 50 Hz, , 240 Volt , Current rating 5 - 30 Amps complete all as specified and as directed by Eng-in-Charge.Make HPL/L&T |
| 115 | S & FElectronic energy DLMS meter 3 phase,4 wire static watthourwith meter cover box current rating 10 to 60 Amps, 3 X 240Vcomplete all as specified and as directed by Eng-in-Charge.Make HPL/L&T |
| 116 | S&F decorative gate light 200 mm dia MOON (OPAL) made up of high grade unbreakable polycarbonate material suitable for retrofit bulb upto 15 W LED lamp complete all as specified and as directed. |
| 117 | S&F decorative gate light 250 mm dia MOON (OPAL) made up of high grade unbreakable polycarbonate material suitable for retrofit bulb upto 20 W LED lamp complete all as specified and as directed. |
| 118 | S&F in replacement/newLED lights fitting 22 Watt, 220V, decorative ultra slim LED tube light polycarbonate body connecting up to from existing/ new ceiling rose complete all as specified and directed |
| 119 | S& F 15 WattTrim NXT LED Pannel square 6500 K cool day light ( 14 X 14) cmrecessed mounted LED completeall as specified and as directed. |
| 120 | S& F 15 WattLED Pannel light RD round warm white 3000 K 220-240 V,50 Hz recessed mounted LED completeall as specified and as directed. |
| 121 | S&F LED post top lantern new generation energy saving,enviromental friendly,long life aesthetically desighned with symmentrical light distribution,spun alumnium landscape luminiare gate light 25 W (OPAL) made in die-cast alumnium housing with decorative clear opal acrylic diffuser complete all as specified and as directed. |
| 122 | S & F LED BOLLARD with excellent light 10 Woutput through its PMMA window ensuring maximum illumnition aspect in sournding diffuser at the upper portion adds functional value into environmentalcomplete all as specified and as directed. |
| 123 | S&Fofintegrated LED batten 10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fittingcomplete all as specified and directed. |
| 124 | S&Fofintegrated LED batten 10 watt (Warm White), 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fittingcomplete all as specified and directed. |
| 125 | S& F 9 Watt decorative wall light STYLO with LED lamp mounting type champange gold finish fixture with plastic bodycompleteall as specified and as directed. |
| 126 | S & F 14/15 Watt LED GLAZE Wall mounted fixture in durable plastic body & designer mesh in gold finish with LED Bulb complete as specified and as directed. |
| 127 | M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 3.0 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1,with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs) completeall as specified &testing on completion. NOTE:-(I)item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra costof additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate. |
| 128 | M&L forservicing, cleaning andtestingof DG sets of make Kirloskar/Cumins /Greaves /Mahindra /Sudhirof capacity 300 KVA bycompany technician /mechanic visiting the installations ofDG sets of following capacitiesat various locations of Babina Cantt. Checking and testing complete DG setson load(Including engine, alternator, AMF panel, Body & chases complete)for its proper functioning and making a list of repairs/ replacements required to be carried out in different parts of the DG sets. Carrying out general servicing and minor repairs and/or replacements, all as directed, including following jobs and the worksas directed :-(i)Checking and cleaning of diesel filters & oil filters and replacing of defective filters (ii) Checking of engine oil level and topping up , if any. (iii) Checking, cleaning and servicing including oiling & greasing of moving parts of engine and making list of repairs / replacements required, if any. (iv) Checking, cleaning, watering & general servicing ofbattery, battery charging system including tightening of nuts, bolts, lugs .(v) Checking the earthing connections of neutral and body of DG set, tightening of connections and making a list of repairs /replacements required, if any. (vi) Checking of self starter and intimating Engr in charge if required to be repaired / specially serviced in workshop.(vii) Checking, cleaning and general servicing of AMF panel including replacement / tightening of nuts, bolts, lugs and other such minor parts, oiling & greasing and making list of repairs / replacements required, if any (viii) Checking, cleaning & general servicing of instrument panel and making a list of repairs/replacements required, if any(ix) Checking, cleaning and general servicing of various parts of DG set such as timer, contactors, meters, etc. and making list of repairs / replacements required, if any. |
| 129 | (x) Tightening / replacement of nut/water /oilleakage from any point and rectify if can be rectified by minor repairs / replacements. (xii) Checking, cleaning and adjusting fan belt tension and making a list of replacements requirted, if any.(xiii) Checking, cleaning & general servicing of exhaust / silencer including checking for leakage of smoke & rectify, if can be rectified by minor repairs / replacements. else make a list of repairs / replacements required, if any. (xiv) Checking, cleaning and tightenening of electrical connections including replacement of minor parts. Checking AMF panels , connections, contactors , relays cable connections etc for proper function(xv) Checking & cleaning of AVM pads, tightening / replacement of nuts, bolts, & washers and making a list of replacements required, if any. (xvi) Checking, cleaning & tightening of exhaust pipe, flange and lagging, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any. (xvii) Checking output of alternator and adjusting the same to specified values, in case of brush type(b) cleaning & servicing of the alternator, minor repairs & replacements (xviii) Checking, cleaning & tightening of all hose pipes, tightening / replacement of nuts, bolts, washers .(xix) Checking, cleaning & servicing of air filter elements :- |
| 130 | Note - Rates quoted by the tenderer aredeemed to include the cost of S&F in replacement of minors parts like nuts, bolts, washers, gaskets, wirings ,lugs, etc., supply and applying oil & greasing and minor repairs to DG set. Other spares like Engine oil, filters etc shall be paid under seprate items(i)Spares like Fuel filter ,Engine Oil and Coolent shall be measurd & paid separately under relevent items of Sch \"A\".(ii) All servicing /repairs works will be carried out by respective company rep/technicianof different DG setcompany makes and provide necessary documentary evidence of the sameContractor has to arrange all visit and other expenses of company technicianand costis deemed to be included in the unit rate and nothing will be paid extra on this account . |
| 131 | All as per item No 128 but DG Set of 160KVA to 200 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 132 | All as per item No 128 but DG Set of 50KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 133 | All as per item No 128 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 134 | All as per item No 128 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 135 | Taking out existing defective Fuel filter element primary and secondary with ring and washer for DG set of 300KVA Make:- Cummins and material and labour for new Fuel filter in existing position and satisfactory testing complete all as specified and directed by Eng-in-Charge. |
| 136 | All as per item No 133 but DG Set of 160KVA to 200 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 137 | All as per item No 133 but DG Set of 50KVA to 100 KVA Make :- Mahindra, Cummins, Kirloskar, Ashokleyland |
| 138 | All as per item No 133 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 139 | All as per item No 133 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 140 | Taking out existing defective oil filter element with ring and washer of DG set of300KVA Make:- Cummins and material and labour for new Oil filter in existing position and satisfactory testing complete all as specified and directed by Eng-in-Charge. |
| 141 | All as per item No 138but DG Set of 160KVA to 200 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 142 | All as per item No 138 but DG Set of 50KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 143 | All as per item No 138 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 144 | All as per item No 138 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 145 | Taking out existing defective Air cleaner elementwith ring and washer ofDG set 0f 300KVA Make:- Cumminsand material and labour for new Air cleaner element in existing position and satisfactory testing complete all as specified and directed by Eng-in-Charge. |
| 146 | All as per item No 143 but DG Set of 160KVA to 200 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 147 | All as per item No 143 but DG Set of 50KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 148 | All as per item No 143 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 149 | All as per item No 143 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 150 | S & F in replacement \"V\" belt for Radiator fan of any size suitable to DG set 10KVA to 300 KVA capacities, |
| 151 | S & F in replacementrubber hose pipe set with clamps suitable for DG set of 300KVA capacitiesMake:- Cumminss |
| 152 | All as per item No 149 but DG Set of 160KVA to 200 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 153 | All as per item No 149 but DG Set of 50KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 154 | All as per item No 149 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 155 | All as per item No 149 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 156 | Taking outof FIP along with its accessoriesfrom DG Set 300 KVAMake :-CUMMINS/MAHINDRA/KRILOSKAR including transportation to authorised service center for Overhauling repair/recalibration and refixing of DG Set including replacement of necessary parts such as nozzel/injection delivery valve holder benjo bolt copper washer roater bearing etc including testing complete all as specified and directed |
| 157 | All as per item 154but DG set capacity 160 KVA to 200 KVA. |
| 158 | All as per item154but DG set capacity 50 KVA to 100 KVA. |
| 159 | All as per item154but DG set capacity 10 KVA to 40 KVA. |
| 160 | M&L for servicing, repairing, maintenance of alternator assembly of DG set of300/200/160KVA Make:- Cummins,Mahindra by decoupling alternator from DG set and strip opening of the alternator replacement of carbon bush holder, with carbon bush, mospeds,capacitor rectifiers,Terminal plateSilicon Rectifier assemblywith metallic plate as existing covered with thin layer of selnium and insulted nut boltcontrol wiring soldering,Flexible rubber coupling,Carbon brushes set of four, Slip ringsand refixing the same in original position with satisfactory testing complete all as specified and directed by engineer-in-charge. |
| 161 | All as per item No 158 above but DG set of 62.5/50/100 KVA Make:-CUMMINS/ MAHINDRA/ KRILOSKAR |
| 162 | All as per item No 158 above but DG set of 10/15/30/35/40/KVA Make:-CUMMINS/ MAHINDRA/ KRILOSKAR |
| 163 | Taking out burnt armature winding wire and rewinding of armature with super enamelead copper winding wire of existing gaugeof 160 KVA to 300 KVA DG Set insulation of armature of class \"B\"insulation and varnishing of armature and drying upto desired temperature and Re-assembling of rotor and stator after rewinding and refixing of alternator with engine by assembling flexible coupling with alternator mouting with nut bolts including making cable connection complete including testing and commissioning at desired load of DG Sets complete all as specified and directed by engineer-in-charge |
| 164 | All as per item161 but DG set capacity 50 KVA to 100 KVA. |
| 165 | All as per item 161 but DG set capacity 10 KVA to 40 KVA. |
| 166 | Taking out burnt field coil and rewinding of field coil with super enameled copper winding of existing gauge of 160 KVA to 300 KVA DG Set insulation of armature of class \"B\"insulation and varnishing of field coil and drying upto desired temperature and Re-assembling of rotor and stator after rewinding and refixing of alternator with engine by assembling flexible coupling with alternator mouting with nut bolts including making cable connection complete including testing and commissioning at desired load of DG Setscomplete all as specified and directed by engineer-in-charge. |
| 167 | All as per item 164 but DG set capacity 50 KVA to 100 KVA. |
| 168 | All as per item164 but DG set capacity 10 KVA to 40 KVA. |
| 169 | M & L for taking out radiator and connecting parts of DG set 160KVA to 300 KVA for repair,welding,brazing,leak testing, descaling & refixing to DG set to its original position and testing on loadfor DG Sets of MakeKirloskar/Cumins/Greaves/ Mahindra /Sudhir complete all as directed. |
| 170 | All as per item167 but DG set capacity 50 KVA to 100 KVA. |
| 171 | All as per item167 but DG set capacity 10 KVA to 40 KVA. |
| 172 | S & F in replacementsolonid Switch for 160 to 300 KVADG set and testing complete for proper functioning for DG sets of Make Kirloskar/Cumins/Greaves/ Mahindra/ Sudhir complete and testing all as directed.. |
| 173 | S & F in replacementsolonid Switch for 50 to 100 KVADG set and testing complete for proper functioning for DG sets of Make Kirloskar/Cumins/Greaves/ Mahindra/ Sudhir complete and testing all as directed.. |
| 174 | S & F in replacementsolonid Switch for 10 to 40 KVADG set and testing complete for proper functioning for DG sets of Make Kirloskar/Cumins/Greaves/ Mahindra/ Sudhir complete and testing all as directed.. |
| 175 | M & L for servicing, repairing, maintenance of self starter assembly of DG set 0f 160KVA to 300KVA capacity complete with switch magnet, carbon set, field coil, solenoid switches and refixing the same in original position complete all as specified and directed. |
| 176 | All as per item No 173 but DG Set of 50KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 177 | All as per item No 173 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 178 | All as per item No 173 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 179 | Descaling of water jacket of engine by using chemical descaling solution with pressure circulation pump,leak testing, soldering, brazing, checking for leakages and recirculating with clear water complete all as directed for DG set of capacity 160 KVAto 300 KVA Make\;-Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.:- |
| 180 | All as per item No 177 but DG Set of 50KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 181 | All as per item No 177 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 182 | All as per item No 177 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 183 | S & F in repairs Anti vibration pad suitable for 10KVA to300 KVA DGsetMake Dunlop or as approved by GEall as directed . |
| 184 | S&F in replacement of Ignition Switch of DG Sets for any DG sets of Make:-Mahindra, Cummins, Kirloskar, Ashokleyland complete and testing all as directed. |
| 185 | S&F in replacement of AVR suitable for DG Set of 160KVA to 300 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 186 | All as per item No 183 butDG set of 50 KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 187 | All as per item No 183 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 188 | All as per item No 183 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 189 | S&F PVCinsulated copper conductor cable 25 Sqmm multistandard single core, of 2 mtr length, solderedwith 2 nos brassmetal battery terminals suitable for 60-180 Ah 12v/24 volt DC battery complete all as specified and directed. |
| 190 | Supply and fix in repair replacement Self starter, 12 Volts, suitable for fixing at100/ 62.5/40/35/30/15 KVA DG Set fixed in repairs complete all as specified. |
| 191 | Supply and fix in repair replacement Self starter, 24 Volts, suitable for fixing at 300/200/160 KVA DG Set fixed in repairs complete all as specified. |
| 192 | Overhauling of water pump assembly complete including material and labour for impeller, shaft seal bearing, gaskets washers and rubber hose complete forDG set of 300/200/160KVA Make:- Cummins, Mahindra |
| 193 | All as per item No 190 but DG Set of 50KVA to 100 KVA Make:- Mahindra, Cummins, Kirloskar, Ashokleyland |
| 194 | All as per item No 190 butDG set of 30 KVA to 40 KVA Make:- Mahindra, Cummins, Kirloskar, Ashokleyland |
| 195 | All as per item No 190 but DG set of 10 KVA to 15 KVA Make:-- Mahindra, Cummins, Kirloskar, Ashokleyland |
| 196 | S&F in replacement control wiring as per existing specifications and sizeof DG Set 160 to 300 KVA for DG sets ofMake:-Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed. |
| 197 | All as per item 194 above but for DG Set 50 to 100 KVAofMake:- Mahindra, Cummins, Kirloskar, Ashokleyland complete and testing all as directed. |
| 198 | All as per item 194 above but for DG Set 10 to 40 KVAofMake:- Mahindra, Cummins, Kirloskar, Ashokleyland complete and testing all as directed. |
| 199 | Disconnection and taking out the unservisable turbo charger assembly for DG set of 300/200/160KVA Make:- Cummins,Mahindraand taking to workshop, strip opening of turbo charger and replacement of repair kit reassembling and fixing back to engine and testing complete all as specified and directed. |
| 200 | All as per item No 197 but DG Set of 50KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 201 | All as per item No 197 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 202 | All as per item No 197 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 203 | Supply and fixing in replacement battery of capacity 12V 180 AHMake:- Exide/Amaron |
| 204 | Supply and fixing in replacement battery of capacity 12V 150 AHMake:- Exide/Amaron |
| 205 | Supply and fixing in replacement battery of capacity 12V 100 AHMake:- Exide/Amaron |
| 206 | M&L for repairing decarburizing, Engine ,cleaning ,washing manifolds exhaust system for DG set 0f 300/200/160KVA Make:- Cummins,Mahindra and connected items including replacement of necessary nuts bolts washers bolts washer etc with necessary masonry work reqd for above complete all as specified and directed |
| 207 | All as per item No 204 but DG Set of 50KVA to 100 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 208 | All as per item No 204 butDG set of 30 KVA to 40 KVA Make:-Mahindra, Cummins, Kirloskar, Ashokleyland |
| 209 | All as per item No 204 but DG set of 10 KVA to 15 KVA Make:--Mahindra, Cummins, Kirloskar, Ashokleyland |
| 210 | S & F in replacement DG Set power controller unit set complete for generator set monitoring, metering and control system to control voltage ,speed governing ,start and stop control for capacity up to 300/200/160KVA DG Set for DG sets of Make Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed. |
| 211 | All as per item 208 above butpower controller for50KVA to 100 KVA DG Set . |
| 212 | All as per item 208 above butpower controller for 30 KVA to 40 KVA DG Set . |
| 213 | Supply and fix in replacement auto logistic Relay for AMF panel for capacity 30 KVA to160 KVA DG sets of Make Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed. |
| 214 | Supply and fix in replacement auto logistic Relay for AMF panel for capacity 200 KVA to 300KVA DG sets of Make Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed. |
| 215 | Supply & Fix 3 pole power Contractor ML-6,110/125 A,415 V of Make L&T or equvalent in ABB/ Siemens/ Crompton |
| 216 | Supply & Fix 3 pole power Contractor ML-10/ML12 ,200/250 A,415 V of Make L&T or equvalent in ABB/ Siemens/ Crompton |
| 217 | S&F inreplacement of contactor AC rating 325 Amp 2 pole, MCX 41 type (2\"no\" +2\"nc\") suitable for 200 KVA DG set complete as specified and directed. |
| 218 | S&F inreplacement of contactor AC rating 250 Amp 2 pole, MNX 185 type (2\"no\" +2\"nc\") suitable for 100 KVA DG set complete as specified and directed. |
| 219 | S & F in replacementoff Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 63 Amp in SS enclosure with side handleMakeHavells /INDO ASIAN/L&T |
| 220 | S & F in replacementoff Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 100 Amp in SS enclosure with side handleMakeHavells /INDO ASIAN/L&T |
| 221 | S & F in replacementoff Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 315Amp in SS enclosure with side handleMakeHavells /INDO ASIAN/L&T |
| 222 | S & F in replacementon Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 200 Amp in SS enclosure with side handleMakeHavells /INDO ASIAN/L&T |
| 223 | S & F in replacementoff Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 400 Amp in SS enclosure with side handleMakeHavells /INDO ASIAN/L&T |
| 224 | S & F in replacementoff Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 630 Amp in SS enclosure with side handleMakeHavells /INDO ASIAN/L&T |
| 225 | S & F in replacementoff Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 1000 Amp in SS enclosure with side handleMakeHavells /INDO ASIAN/L&T |
| 226 | S & F in replacement MCCB\"s,415 Volts, 3 pole ,fixedthermal & fixed magnetic settings,having 500 Amps 50 KA 3 Polecapacities complete all as specified and as directed.MakeHavells /INDO ASIAN/L&T / C&S . |
| 227 | S & F in replacement MCCB\"s,415 Volts, 3 pole ,fixedthermal & fixed magnetic settings,having 630 Amps 36 KA 4 Polecapacities complete all as specified and as directed. MakeHavells /INDO ASIAN/L&T / C&S |
| 228 | S & F in replacement MCCB\"s,415 Volts, 3 pole ,fixedthermal & fixed magnetic settings,having 100 Amps 36 KA 3 Polecapacities complete all as specified and as directed. |
| 229 | S & F in replacement MCCB\"s,415 Volts, 3 pole ,fixedthermal & fixed magnetic settings,having 160 Amps 25 KA 3 Polecapacities complete all as specified and as directed. MakeHavells /INDO ASIAN/L&T / C&S |
| 230 | S & F in replacement MCCB\"s,415 Volts, 4 pole ,fixedthermal & fixed magnetic settings,having 63 Amps 16 KA 3 Polecapacities complete all as specified and as directed. MakeHavells /INDO ASIAN/L&T /C&S |
| 231 | Supply and fill/top up the distilled water for the battery complete all as specified and directed . |
| 232 | Supply onlyfor toping up of pre mix Coolant for DG Set complete all as specified and directed . Make- nextron , servo , velvo line. |
| 233 | Supply and filling in replacement for toping up Engine oil 15 W 40 in 200 ltr steel drum (Barrel) factory sealed non returnable drum complete all as specified and directed. Make- nextron, servo , velvo line. |
| 234 | Taking out of PT Pump along with its accessories form DG set 100 to 300 KVA Make:-Cummins/ Mahindra/ Kirloskar including transportation of authorised service center for repair/recalibration and refixing of DG set including testing complete all as specified and directed. |
| 235 | Taking out of PT Pump along with its accessories form DG set 62.5/40/30 KVA Make:-Cummins/ Mahindra/ Kirloskar including transportation of authorised service center for repair/recalibration and refixing of DG set including testing complete all as specified and directed. |
| 236 | Dismantling the fly wheel coupling between engine and alternator and Supply and replace complete set of bullet rubber bushes, coupling nuts & bolts including proper alignment of engine & alternator for smooth running for DG set of capacity100 to 300 KVA complete all as specified and directed by Engineer-in-Charge of he following capacity. |
| 237 | All as per item No 234 above but DG set of 62.5/50 KVA Make:-Kirloskar, Ashokleyland |
| 238 | All as per item No 234 above but DG set of 15/30/35/40 KVA Make:-Kirloskar, Mahindra |
| 239 | M&L for repairing, PCB assy complete with display and update software including wiring work suitable for DG Set of capacity 50 to 63 KVA |
| 240 | M&L for repairing, PCB assy complete with display and update software including wiring work suitable for DG Set of capacity 100 to 300 KVA |
| 241 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts Indoor type Feeder pillar box \"Pedastal type\" Confirming to IP 65, CPRI approved,factory fabricated &factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penalmade out of suitable size angle iron, channel and fabricated from 3.15 mm thick(minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & includingbusbars made of pure copperduly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitableearth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. ( For \"C\" Zone):- |
| 242 | Incoming (a) Alluminium bus bar - 600 amps rating - 03 Nos. for phases and400 amp rating - 01 No. for neutral |
| 243 | (b) MCCB 4 pole 400 amp, 36 KA, 415 volt, 100% Icu, adjustable thermal magnetic protection(O/L & S/C protection) - 01 No |
| 244 | (c)3 phase Voltmeter (0-500 V) digital type with selector switch-01 No |
| 245 | (d)3 phase Ammeter (0-600 Amps) digital type with CT\"s of suitable ratio andselector switch - 01 No. |
| 246 | (e) RYBLED type indication lamp- Set of 03 |
| 247 | Out going:-(a) MCCB 3 pole 250amp, 25 KA, 415 volt, 100% Icu - 02 Nos |
| 248 | (b) MCCB 3 pole 160 amp, 25 KA, 415 volt, 100% Icu - 02 Nos |
| 249 | M&L for earthing complete with galvanised steel earth plate electrode of size 600X600X6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below the ground level connected to galvanised iron strip of 32x6 mm as earth lead by means ofbolts nuts check nuts & washers of galvanised iron or steel ,surrounded by charcoal of coke and salt, protected by GI pipe 40 mm bore (light grade), water pipe 20mm bore GI medium grade with funnel and wire mesh,and making chamber of PCC (1:4:8) type D-2 using 40 mm graded stone aggregate and coping shall be in PCC(1:3:6) type C-1 using 20 mm graded stoneaggregate, 50 mm thick cover of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia TMTbars @ 80 mm c/c boath ways including excavation and earth work and removal of surplus soil todistance n exc 50 m complete all shown in electrical plate No 3of SSR part- 2010 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete all as specified and directed.Note :-(i) The cost ofGI earth lead & G Ipipe of 7.50 mtr length for protection of GI wire and excavation work for pit shalldeemed to be included in this item. (ii)Earthing test will be carried out and if desired result not achieved and the earthing will be redone to achieve desired result without any extra payment.(iii)Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate. |
| 250 | S&F 1100 Volts grade heavy duty cable PVC insulated stranded Copper conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of size one 3 core cable flat or circular of size 16 sqmm etc complete all as specified and directed. |
| 251 | Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with multi stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 95 sqmm 3.5 core . |
| 252 | Description all as per item No 242 above but of size 70 Sqmm 3.5 core and ditto |
| 253 | Description all as per item No 242 above but of size 120 Sqmm 3.5 core and ditto |
| 254 | Supply in replacement Battery Charger24 Volt DC,for dg set complete all as specified and directed. |
| 255 | Repair & Maintenance of existing canopy of eco friendly DG Set of any capacity, cleaning of internal & external parts, tightening of loose parts, painting of rusted area, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations complete all as specified and directed. |
| 256 | Material and labour in replacement broken MS Hinges suitable for Canopy door for any type/capacity of DG Sets (as per sample) complete all as specified and directed. |
| 257 | M&L for preparing old painted surface of DG sets of capacity 10 KVAto 40 KVA(complete including engine, alternator, body & chases) by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primers using suitable sprayers. Applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and as directed. |
| 258 | All as per item No 248 but DG set of capacity 50 KVAto 62.5 KVA |
| 259 | M&L Dismantling Posts or struts (wood, steel or R.C.C) any section, including taking out embedded portion and making good disturbed ground. |
| 260 | M&L for structural MS frame work half round or other stock section including painting of ms surface securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bendingcold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc)all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including onecoat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed. |
| 261 | S& F pre-painted galvalume roofing sheet with deep depth trapezoidal prpfile of thickness 0.50mm(26 gauge) ,fixed with specially designed one touch fasteners and allied components of colour and and pattern as directed by the GEcomplete all as specified and directed. |
| 262 | M&L for chain link MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any size any type to any type strands rails, straining bolts etc. |
| 263 | S&F mild steel screw bolt (mechine made) with hexagonal or square, head, n.exc 5 cm but n.ecx 10 cm dia. |
| 264 | M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as directed. |
| 265 | Servicing and repairs in Automatic Main Failure ( AMF) control panel of 180 KVA at old power house by complete checking entire circuit and replacing the defective parts like contactor, logic control relays of AMF function, HRC fuses, start and stop relays, detoriated control wires and completing the panel in all respect. starting and testing and commissioning the AMF panel with DG set in both manual and auto mode function complete all as specified and directed by Engineer-in-chargeNote: The replacement parts and items shall be measured and paid seperately |
| 266 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in foundations/foot path etc complete all as specified and directed by Engr-in-Charge. |
| 267 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thicknessbelow or above ground level including removal of debris complete all as specified and directed. |
| 268 | M & L for dismantling and taking up/down DG setsof any capacity of any size from foundations after disconnecting electric connection and transportation from one location to an other location at babina cantt incl re-assembling, re-fixing in position, including connecting in original position & testing complete as directed andspecified . |
| 269 | Taking down, dismantling / unscrewing electric water heater (Geyser) for repair / servicing and refixing after repair reconnecting of electrical and water supply and testing with water pressure complete asspecified and as directed.Note : If required to deposit unserviceable water heater to AGE (E/M) yard and collection serviceable against replacement from AGE (E/M) yard is responsibility of contractor) |
| 270 | S & F in replacement heating element 2 KW , Triangle type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 271 | S & F in replacement heating element 1.5 KW, Triangle type of any type copper sheathed and nickel plated of suitable size for waterheater complete all as specified and as directedMake :- Bajaj / Airex/ / Elecon Agency Or other ISI Marked |
| 272 | S & F in replacement heating element 2 KW, cup type of any type copper sheathed and nickel plated of suitable size for waterheater complete all as specified and as directedMake :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 273 | S & F in replacement heating element 1.5 KW, cup type of any type copper sheathed and nickel plated of suitable size for waterheater complete all as specified and as directedMake :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 274 | S & F in replacement heating element 2 KW ,Square typeof any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 275 | S & F in replacement heating element 1.5 KW, square type of any type copper sheathed and nickel plated of suitable size for waterheater complete all as specified and as directedMake :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 276 | S & F in replacement heating element 2 KW watt,Porcelain type for DITZ/VENUS type water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 277 | S & F in replacement heating element for Solar water heater 2 KW, (size as per site requirement)ISI marked of any type copper sheathed and nickel plated of suitable sizecomplete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 278 | S & F in replacement heating element for Solar water heater 3 KW, (size as per site requirement)ISI marked of any type copper sheathed and nickel plated of suitable sizecomplete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 279 | S & F in replacement fusible plug having melting point 90 degreeC to 100 degree (as per sample) complete all as specified and as directed. |
| 280 | S & F in replacement safety valve dead weight type for 25 Ltr gyeser (As per sample) complete all as specified and as directed. |
| 281 | S & F in replacement safety valve dead weight type for 50 Ltr Gyser(As per sample) complete all as specified and as directed. |
| 282 | S & F in replacement glass wool for geyser complete all as specified and as directed. |
| 283 | S & F base platecomplete with rubber packing suitable for water heater (geyser) for 25 litre capacity any make complete all as specified and as directed. |
| 284 | S & F in replacement base platecomplete with rubber packing suitable for water heater (geyser)for 50 Ltr any make capacity complete all as specified and as directed |
| 285 | S&F in replacement outer cover of geyser suitable for 25 Ltr capacity of geyser, complete all as directed |
| 286 | S&F in replacement outer cover of geyser suitable for 50 Ltr capacity of geyser, complete all as directed |
| 287 | S & F in replacement thermostate switch suitable for 25 Ltr water heater(Geyser) of size 11\"/11\"/280 mm any make ranging from 5 degree centigradeto 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 288 | S & F in replacement thermostate switch suitable for 25 Ltr water heater(Geyser) of size 7\"/7\"/175 mm any make ranging from 5 degree centigradeto 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 289 | S & F in replacement thermostate switch suitable for 25 Ltr water heater(Geyser) 4 terminals 16 KA 250 Volts AC Capillary thermal Switch thermosate any make ranging fromincluding making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 290 | S & F in replacement thermostate suitable for 50 Ltr water heater(Geyser) of any make ranging from 5 degree centigradeto 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 291 | S&F in replacement storage type water heater (Geyser), 230 Volt AC, 25 Ltrs capacity 2000 W with minimum 5-star rating comprising inner tank, suitable heatng element, thermostate with adjustable temperature stting 0-90 C, indication lamps provision ofr inlet outlet and air vent connections & NRV, PVC connection 15 mm size, heavy duty with brass nuts, 450 mm long mounteted on wall surfaces including all fixing arrangement such s faster bolts, nuts washers etc complete including making gooddisturbed wall surfaces matching with the existing surfaces and finishing all as specified and as directed by Engr-in-charge Make - Havells /bajaj/orient/cg. |
| 292 | S&F storage type water heater (Geyser), 230 Volt AC, 50 Ltrs capacity with minimum 5-star rating comprising inner tank, suitable heatng element, thermostate with adjustable temperature stting 0-90 C, indication lamps provision ofr inlet outlet and air vent connections & NRV, PVC connection 15 mm size, heavy duty with brass nuts, 450 mm long mounteted on wall surfaces including all fixing arrangement such s faster bolts, nuts washers etc complete including making gooddisturbed wall surfaces matching with the existing surfaces and finishing all as specified and as directed by Engr-in-charge Make - Havells /bajaj/orient/cg. |
| 293 | S & F in replacement Geyser Assembly for 25 Ltr capacity geyser Triangle type / Square type ( As per sample ) with rubber packing ( As per Sample ) complete all as specified and as directed.Airex/ / Elcon Or other ISI Marked |
| 294 | S & F in replacement Geyser Assembly for 50 Ltr capacity geyser Triangle type / Square type ( As per sample ) with rubber washer complete all as specified and as directed.Airex/ / Elcon Or other ISI Marked |
| 295 | S & F in replacement geyser inner tank stainless steel of 25 litre capacity complete all as specified and as directed |
| 296 | S & F in replacementgeyser inner tank stainless steel of 50 litre capacity complete all as specified and as directed |
| 297 | S & F in replacement PVC connection pipe 15mm dia of 450mm long with check nuts on both end with rubber washer complete all as specified and as directed. |
| 298 | S & F in replacement PVC insulated flexible cable 3 core with standed copper conductor of size 2.5 Sqmm againstunserviceable flexible cable complete all as specified and as directed. |
| 299 | S & F in replacement PVC insulated flexible cable 3 core with standed copper conductor of size 4.00 Sqmm againstunserviceable flexible cable complete all as specified and as directed. |
| 300 | S & F in replacement plug top 3 pin 15 Amps ISI Marked as specified and as directed. |
| 301 | S& F in replacement non return valve 15 mm dia bore cast copper alloy screwed for iron pipe or brass ferrule complete all as specified and as directed. |
| 302 | S& F in replacement 15mm bore GI tubing, medium grade fixed on walls/floor/ceiling with and including necessary GI fittings such as sockets, bends, elbows, tees, short pieces etc including taking down existing GI tubing including making good disturbed surface complete all as specified and directed. |
| 303 | S& F in replacement 20 mm bore GI tubing, medium grade fixed on walls/floor/ceiling with and including necessary GI fittings such as sockets, bends, elbows, tees, short pieces etc including taking down existing GI tubing including making good disturbed surface complete all as specified and directed. |
| 304 | S & F in replacement stop valves chromium plated cast copper alloy, screwed down high pressure with crutch or butter fly handle external threaded screwed bothends for iron pipes of 15 mm dia complete all as specified as directed. |
| 305 | S & F in replacement bib taps chromium plated screwed down high pressure with crutch or butterfly handle external threaded screwed for iron pipes 15 mm dia complete all as specified. |
| 306 | S & F in replacement neon lamp indicator red / green rectangular / round type, complete all as specified and as directed. |
| 307 | Supply & fixing GI nut bolts any type any size as per site requerment all as directed |
| 308 | M & L insulation for hot water worn out insulation 15mm dia GI pipe, medium grade for solar water heater system complete all as specified and as directed. |
| 309 | M & L for brazing rod of copper / steel inner tanks of 25 ltr capacity of geyser and testing complete all as specified and as directed. |
| 310 | M & L for brazing rod of copper/ steel inner tanks of 50 ltr capacity of geyser and testing complete all as specified and as directed. |
| 311 | S & F sheet metal enclosure with two pin socket , chain plug cover with one MCB SP of 20 Amp capacity with alignment 10 KA ‘C’ seriescomplete all as specified and as directed. |
| 312 | Suppling and fixing Gun metal gate valve 15 mm bore with all GI fitting as per existing all as specified and directed |
| 313 | Suppling and fixing in replacement of Gun metal gate valve 20 mm bore with all GI fitting as per existing all as specified and directed |
| 314 | Supply and fixing in replacement of solar plate collectoras per existing complete with rubber packingwith solar panelglass ( As per sample ) complete all as directed. Note :-The rates shall be deemed to be included for all materials or manpower required which are otherwise not specifed in the discriptionbut are requred to ensure proper installation commissioning and operation of soler water heater system as directed at site |
| 315 | Supply and fixing in replacement of 500 ltr capacity of rotational moulded polyethylene water storage tank 2 layered construction ISImarked BLACK cylindrical vertical with closed top, hoisting and fixing in position including 20mm bore GI pipe medium grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacityexceeding 500 ltr complete all as directed.Make -Sintex / Rotex |
| 316 | Supply and fixingin replacement of 1000 ltr capacity of rotational moulded polyethylene water storage tank 2 layered construction ISImarked WHITE cylindrical vertical with closed top, hoisting and fixing in position including 20mm bore GI pipe medium grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacityexceeding 1000 ltr complete all as directed.Make -Sintex / Rotex |
| 317 | S&F, MCB SP 240 volts, 6to 40 Amps, \"C\" series 10 KA including connection with suitable size copper lugs.complete all as specified and directed. |
| 318 | S & F in replacement of MCB protected plug socket power units 20A/25A SP with MCB 20A/25 A SP ‘C’ series fixed in concealed or surface complete all as specified and as directed.Make Havells/Indoasian/ABB/Legrand/Benlo |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy