}

Tender For Construction Of An Amusement Park At Verinag. Advertised Cost=?29.10 Lacs ( Inclusive Of All Applicable Taxes With 18% Gst), verinag-Jammu And Kashmir

Tender Notice

52633721
Tender For Construction Of An Amusement Park At Verinag. Advertised Cost=?29.10 Lacs ( Inclusive Of All Applicable Taxes With 18% Gst)
Tender
Indian
Jammu And Kashmir
Verinag
08-12-2025

Tender Details

Tender For Construction Of An Amusement Park At Verinag. Advertised Cost=?29.10 Lacs ( Inclusive Of All Applicable Taxes With 18% Gst)-12-Seater Pendulum RideMaterial: 1:Main Structure: Heavy-Duty MS Steel ASTM A36.2: Seats: FRP (Fiber-Reinforced Plastic) with Foam and PU Cushions3:Pendulum Arm: Heavy Steel with Balanced Counterweights and sufficient cushioning of PU and foam Finish: Automotive Paint Finish for corrosion resistanceSeating Capacity 12 Persons,Ride Height 20ft,Pendulum Length 12–12 ft,Motor Power 5 HP & 2 HP,Swing Angle 120°–130°,Speed Control VFD (Variable),Power Supply 3-Phase, 380–440V, 50Hz,Ride Cycle Duration 2–3 min per cycleTotal Weight not less than 5 Tons (approx.)Ride Motion1 Pendulum Swing: Forward & Backward Arc Movement2 Rotation: Central hub rotation synchronized with swing motion3 Speed Control: Variable Frequency Drive (VFD) for smooth acceleration & decelerationMechanical & Electrical System1 Drive Motor: 5 HP and 2 hp Electric Motor2 Swing Angle: Up to 120°–180° (adjustable)3 Rotational Speed: 10–15 RPM (variable)4 Power Supply: 3-Phase, 380–440V, 50HzSafety Features1 Restraint System: Over-the-Shoulder Safety Harness + Secondary Safety Belt2 Fencing: MS Steel Fencing with Gates Around Ride Platform3 Emergency Stop: E-Stop Buttons at Control Panel and Operator Position4 Safety Compliance: Meets ASTM Safety Standards (ASTM F2291, ASTM F770,ASTM F2137)5 Earthing:Suitable number of chemical earthings ensuring the safety of the Riders.PENDULUM RIDE 1 Operator Control Cabin2 Fencing & Platform Deck3 LED Decorative Lightning System 4 Music System Integration 5 Electrical Panel with VFD & PLC Controls. 2 BULL MECHANICAL AMUSEMENT RIDE:Dimensions & Structure1: Platform Size: 16 ft × 16 ft (standard), with inflatable safety surround 2: Ride Base Material: Heavy-duty Mild Steel (ASTM A36)3: Inflatable Material: SRF 560 GSM PVC Coated Fabric (Waterproof & Fire Retardant)4: Bull Body Material: Molded soft foam with real leather.5: Inflatable Wall Height: 2 ft (for safety)6: Total Height: Approx. 4–5 ft including bull and platformMechanical System1: Motor Type: Industrial-grade servo motor / Single-phase motor / DC motor of reputed make( BHEL,Kirloskar,Crompton)2: Motor Power: 2 HP (Variable Speed Control)3: Rotation Speed: 0–40 RPM (adjustable)4: Control System: Digital Control Box / automatic programs5: Power Requirement: 220V–240V, 50 Hz Single Phase6: Inflatable Size:16 ft × 16 ft × 3 ft7: Load Capacity:100–120 kg8: Weight (Total): 250–300 kg (Approx.)9: Control System: Digital10: Operating Temperature 0°C to 50°CSafety Features1: Emergency Stop Button: Yes, for immediate shutdown2: Automatic Stop: On fall detection or preset duration3: Inflatable Cushion: Soft landing area with 360° safety surround4: Safety Certification: CE / ISOEarthing:Suitable number of chemical earthings ensuring the safety of the Riders.Operation & Controls1:Ride Modes: Manual, Automatic, Competion Mode2: Speed Levels: 5–10 adjustable levels3: Display: Digital Timer & Speed Indicator 3 Monkey Ride Size : Height: 12 ft × Width: 12 ft × Length: 12 ftCapacity: 10 Seater (Kids & Adults)Material: Material for main column & arms: structural steel grade S355Main shaft: 42CrMo (quenched & tempered)Power Supply: Electric Operated (3 Phase)Drive & power:Motor: 3-phase electric motor, 2 HP.Starter & control: VFD (Variable Frequency Drive) for soft start/stop and speed control; ensures smooth acceleration and deceleration.Control Panel: 16 A fully automatic panel with PLC, emergency stop (E-stop), door interlocks, key switches and lockable source isolation.Gearbox & drive train:Gearbox type: 2 HP Industrial Gearbox Include torque limiter (mechanical), safety couplings, flexible coupling to shaft, and overspeed protection.Lubrication: forced or splash lubrication; gearbox drains & sight glass for oil change intervals. : Control Panel: 16 AMP Fully Automatic Control PanelDrive System: Center Shaft with Rotating ArmOperation: Manual / AutomaticRide Theme: Monkey Jungle Theme (Decorative FRP Characters)Paint: Corrosion protection with Hot-dip galvanize on structural steel with 2K PU topcoat (automotive-grade).Bearings & shaft:Main shaft bearings: spherical roller bearings to accommodate misalignment and heavy radial/axial loads; carriage with housing & grease nipples.Thrust capability: select bearing pair to handle vertical loads + dynamic loads with safety factor 2.Safety & redundancy:Restraints: individual safety bars + seat belts (dual redundant). Secondary mechanical latch that can engage if primary fails.Braking: Primary service brake (electrically controlled) + fail-safe mechanical brake (spring-applied, electrically released) to hold load on power loss.Limit switches (mechanical + electronic), overspeed detection, emergency stop mushroom buttons (at operator station and entry points).Enclosed wiring in cable trays, IP65 junction boxes, emergency manual override (hand crank with mechanical locking).Load sensor/strain gauge on main support to detect overloads.Anti-rollback and lock pin for maintenance.Earthing:Suitable number of chemical earthings ensuring the safety of the Riders. Safety Compliance: Meets ASTM Safety Standards (ASTM F2291, ASTM F770,ASTM F2137) 4 Providing and fixing Automatic motor control centres fabricated from 16 gauge M.S. sheet with Powder Coated finish. The control panels should be compatible with H.P. of the motor as under and as per spcifications with automatic star delta starters. (One separate panel to be located in the plant room).Ingress Protection: IP67 or higher for dust and moisture protectionMounting: Wall-mounted or floor-standing.a. Rotary type Auto/Manual/ ON/OFF Changeover switches.of Min. 100 Amps. rating.b.Fully taped aluminium bus bar of required capacity in a separate bus bar chamber.Single phasing preventors of suitable rating one for each motor.c.Ammeter and Voltmetersd.Colour coded internal wiring from incoming main to bus bar, switch gear, starters, meters indicating lamp etc., complete in all respects. Complete item.The Outgoing shall included 1.Outgoing Feeder for cummilative 5 Hp for for Pendlum ride with suitable starter or as per OEM recomendations.1a.Outgoing Feeder for cummilative 2 Hp for Pendlum ride with suitable starter as per OEM recomendations.2.Outgoing Feeder for cummilative 2 Hp for Bull ride with suitable starter or as per OEM recomendations.3.Outgoing Feeder for cummilative 2 Hp for Monkey Ride with suitable starter or as per OEM recomendations.4.Auxillary Feeder for Lighting and other accessories.Any other electrical items necessary for the commissioning Cabling (via Cable trays) from control panel to the individual equipments including complete earthing of all equipmentsThe Scope also Includes complete design, fabrication, supply, installation, interconnection, testing, and commissioning of the MCC at site, complete in all respects.Also,the panel shall have suitable number of chemical earthings ensuring the safety of the panel and operators 5 P/F of electrical cables to Main Control Panel3.5 Core x 35 Sq mm Al Cable 6 Supply, installation, testing & commissioning of 3 Phase-20 KVA servo-stabilizers including all allied electrical acessoriesThe stabiliser should have following specifications:a) Capacity:20 KVA, 3-phase unbalanced typeb) Input: (100-265) V AC P-N; (170 - 460) V AC P-Pc) Output: 415 V ± 1% - phase to phase d) Supply: 3 phase, 4 wires, 50Hze) Operation: Automaticf) Duty cycle: Continuousg) Transformer windings: Copper wound on CRGO laminations as per IS specificationsh) Cooling: Oil cooledi) Efficiency: Better than 98% at full loadj) Overload capacity: 15% for continuous 4 hoursk) Waveform distortions: Nill) High speed voltage correction: up to 8V to 20V per secondm) Protections: Under voltage, Over voltage and Overload with time delayn) Other features: LED indicators, Digital AC ammeter, AC voltmeter, Frequency meters, Phase Sequence meters, Single phase preventer, Stabilizer by-pass arrangement.The Job also includes complete installation with laying of foundation block as per CPWD norms. 7 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1.5:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 min nominal size) including carriage 8 Steel reinforcement for R.C.C work including straitening,cutting, bending,placing in position and binding all complete upto plinth level TMT bars of grade Fe-500D or more 9 Structural steel work in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of approved steel primer all complete ( welded)description: 10 Earth work in excuation by mechnical means ( hydraulic excuavator) in trenches for foundation, abutments, including dress ing of sides and ramming of bottoms lift upto 1.5 m , including getting out excuavted earth, diposal of surplus earth as directed , within a lead of 50m , all kinds of soils. 11 P/L of stone soling hand packed including carriage of same from approved source upto the site of work complete job 12 Centering and shuteering including strutting, propping etc and removal of formwork from the site for all works from foundation to dirt wall level Please Enable Macros to View BoQ information

Key Value

Document Fees
INR 1100 /-
Tender Value
INR 29.10 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail