| 1 | Supply and fixing on wall, installation, testing & commissioning in replacement of hi wall split units BEE 5 star rated indoor /outdoor (evaporator and condenser shall be of copper), inverter type copper tubing of required size for proper installation and outdoor unit including wall / floor mounted stand complete with cordless remote control unit and with capacity 1.5 TR 230 volt AC supply complete all as specified and as directed by engr in charge. |
| 2 | M&L for sub main wiring with two single core FRLSH PVC insulated flexiblemulti stranded copper conductor cable of size 4 sqmm 1100 volt grade (ISI marked ) drawn through in and including PVC heavy duty 25mm bore conduitwith necessary accessorieslike bend, unction box etc. Two run of 4 sqmm single core multi standardcopper conductor alongwith one run of single core single core 2.5 sqmm for continuous as earth wire in green colour.. |
| 3 | M&L for sub main wiring with two single core FRLSH PVC insulated flexiblemulti stranded copper conductor cable of size 6 sqmm 1100 volt grade (ISI marked ) drawn through in and including PVC heavy duty 25mm bore conduitwith necessary accessorieslike bend, junction box etc. Two run of 6 sqmm single core multi standardcopper conductor alongwith one run of single core single core 4 sqmm for continuous as earth wire in green colour.. |
| 4 | Supply and fixing of MS Stand as per OEM Recommendation and Placing of indoor and Outdoor Unit on MS Stand of C Channel. |
| 5 | supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, wall mounted type, digital type designed for input variation 160 volt to 270 volt with output voltage stabilized 230 v of capacity 4.00 kVA complete all as specified and directed. |
| 6 | Supplyand fix sheet metal enclosure SPN with a two pin and earth plug socket complete including with 20Amps MCB\"C\" curve single pole 240 Volt Ac complete all as specified and as directed. |
| 7 | S & Ffor sheet metal enclosures distribution board where MCB to be used with 200 Amps rated bus bar CL-IP-43 240 V, 12 way triple pole & neutral link |
| 8 | M&L for MCB single pole & neutral 6-32 Amps, 240 V . |
| 9 | M&L for MCB single pole & neutral 40 to 63 Amps, 240 V . |
| 10 | M&L for MCB triple pole & neutral 63 Amps, 240 V |
| 11 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) of four pole and current carrying capacity 40 to 100 ampere in the DB complete with connection testing and commissioning. |
| 12 | Supply and fixing for sheet metal enclosure distribution board where MCB to be used with 200 amps rated bus bar CL-IP-43 240 volt ,8 way single pole neutral link. |
| 13 | Supply and fixing in replacement for sheet metal enclosure distribution board where MCB to be used with 200 amps rated bus bar CL-IP-43 240 volt ,8 way single pole neutral link. |
| 14 | Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 5000 Cum per hour or nearest size with Steel body complete all as specified and directed by eng - in-charge. |
| 15 | Supply and fix AIR Curtain ABS body with inbuilt sensor and remote control for single phase supply , Max air of velocity at nozzle 21M/S and noise level 50-55DB , size 4 ft and dimension 1200x230x220mm complete all as specified and directed. |
| 16 | Supply install & testing and commissioning of suitable sensor kit for automatic air curtain complete all as specified and directed. |
| 17 | Supply and fix bottled water dispenser, having option of dispensing hot and cold and ambient feature ofwater with cooling capacity 3 ltrs/hr and tank capacity of 3.4trs, heating capacity 6 ltrs/hr and tank capacity 1.6 ltrs, working in R - 134 a refrigerant with inbuilt freezer and proper indicating lights on body complete all as specified and directed. |
| 18 | Supply and fix desert cooler electric driven (three phase phase), having nominal air delivery (m3/hr) 8500, capacity 135 lit and size 1000 sqft with dimension 865x650x1480 mmcomplete all as specified and directed |
| 19 | supply fixing testing and commissioning of electrical chimney 120 CM with feature of filter less & auto clean technology oil collector tray, inbuilt light ,digital display noise level 46 DB 350 wattmotor capacity with copper winding extra installation kit , air suction capacity 1400 cum/hr input voltage range 220-240 v 50 hz and fitting in wall as concealed orcomplete duct assembly required as per the site requirement complete all as specified and directed by Eng - in – charge. ( MAKE- BOSCH/HINDWARE/SUNFLAME) |
| 20 | M&L in sub main wiring with two single core FRLSH PVC insulated multi stranded copper conductor FRLSH cable of size 6 sqmm 1100 volt grade (ISI marked ) drawn through in and including PVC heavy duty 25mm bore conduit concealed in wall & conduitaccessories thickness should not be less than 1.8 mm fixing in wall with clamps with 6 sqmmmain phase -neutral supply cable alongwith one run of single core 4 sqmm for continues earth wire in green colour |
| 21 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, including steel iron angle iron channel of height 5 ft height and size 35x35x5 mm with impact and corrosion resistant, including complete welding work, saddle work etc., complete with driver and lamp complete all as specified by Engr-in-Charge. |
| 22 | S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 23 | Taking down carefully copper/aluminium point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc,. |
| 24 | M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multi-stranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly, drawn in concealed conduit heavy duty with accessories (like bend, junction boxes etc.,)GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : -Note : Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators as required at site. |
| 25 | One light point controlled by one switch one way. |
| 26 | One fan point controlled by one switch one way. |
| 27 | One 3 pin socket outlet 5 Amp on same board with other switches. |
| 28 | One 3 pin socket outlet 5 Amp on Independent board with other switches. |
| 29 | All same as per item ser No 24.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, FRLSH, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multi-stranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independent board. |
| 30 | S&F switch modular one way 6 Amps 230 volt, 1 module. |
| 31 | S&F switch modular one way 16 Amps 230 volt 1 module. |
| 32 | S&F Socket modular 6 Amp 2/3 pin combined two module. |
| 33 | S&F Socket modular 6&16 Amp 2/3 pin combined two modules. |
| 34 | S&F Modular stepped type fan regulator, 2 modules. |
| 35 | S&F Ceiling rose surface bakelite 65x50mm three terminal. |
| 36 | Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, co-related colour should be minimum 6000 degree kelvin complete all as specified and directed. |
| 37 | Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 10 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, co-related colour should be minimum 6000 degree kelvin complete all as specified and directed. |
| 38 | S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED,complete pre-wired, including suitable bracket for fixing light on wall or any indicated location all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL25W or equivalent model approved makes. |
| 39 | M&L for celling light fittings of Skylux LED efficient 2x2 (600x600 mm ) Luminaire and glare free soft illumination of capacity 36 watt LED white colour complete suitable for roof ceiling including connecting uptowith driver 3 core flexible conductor copper cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 40 | M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multi-stranded copper conductor, FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, junction boxes etc.,) including taking down old unsv sub main wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green colour. |
| 41 | S & F in replacement of flexible PVC insulated FRLS 4 Sqmm 2 core wire. |
| 42 | Supply and replace sheet metal enclosures distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion complete including taking out old unserviceable sheet metal enclosures complete all as specified and directed. |
| 43 | M&L in repairfor MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 44 | S&F in repair for MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 45 | M&L in repair for MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 46 | M&L MCB triple pole & neutral 40 to 100Amps, 240 V |
| 47 | S & F in replacement of sheet metal enclosures double door distribution board where MCB to be used with 200 Amps rated bus bar CL-IP-43 415 V, 12way Triple pole & neutral link |
| 48 | Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate)complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.(ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |