Tender For Provision Of Partition Wall Garbage Segregation Centre And Augmentation Of Sewage Line Under Age I Cg Mangalore; 1 Excavation in trenches, not exceeding 1.5mtr wide and not exceeding 1.5metre in depth for foundations, not exceeding 10 Sqm on plan for manholes etc and getting out in soft/disintegrated rock, complete all as specified. 2 Excavation in trenches, not exceeding 1.5mtr wide and not exceeding 1.5metre in depth for foundations or for shafts, wells, cesspits, manholes, pier holes not exceeding 10 Sqm on plan for manholes etc and getting out in Hard/ dense soil complete all as specified. 3 Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in Hard/dense soil complete all as specified 4 Returning filling in soft/disintegrated rock including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified. 5 Returning filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in hard/ dense soil complete all as specified. 6 Removing excavated soil n. exc. 50 mand depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified. 7 Removing excavated soft/disintegrated rock exc. 250 m but n exc. 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified. 8 M&L for Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates) as in foundation, mass concrete filling complete all as specified 9 M&L for formwork to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed. 10 M&L for formwork to sides of concrete foundation, footing, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for fair finished surfaces complete all as specified and as directed. 11 M&L for formwork to sides of pillar, post, struts, piers, columns and stanchios for rough finished flat surfaces complete all as specified and as directed. 12 M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. , for fair finished flat surfaces complete all as specified. 13 M&L for Reinforced Cement Concrete Design Mix M30 (20mm graded aggregates) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. 14 M&L for Reinforced Cement Concrete Design Mix M30 (20mm graded aggregates) in Columns, pillars, piers, posts and struts complete all as specified. 15 M&L for Reinforced Cement Concrete Design Mix M30 (20mm graded aggregates) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified. 16 S& F TMT steel bars 8 to 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified. 17 S& F TMT steel bars of 5mm dia and over upto and including 10mm dia in stirrups, spaces and binder securing with clips complete all as specified 18 M&L for Pre-cast cement concrete block masonry with solid blocks Type C1 1:3:6 (using 20 mm graded aggregate)exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified. 19 M&L for dressed laterite stone masonry, well bonded, bedded and solidly hearted built in CM 1:4 complete all as specified. 20 M&L for dressed laterite stone masonry, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified. 21 M & L for Firebrick work in linings to fire places, flues, etc. (other than in chimney shafts), set, jointed and pointed in fireclay complete all as specified. 22 M & L for Pargetting flues exceeding 0.20sq. m in sectional areas, with 20mm thick lime mortar (1 lime:2 sand: 1cowdung) and coring complete all as specified. 23 M&L for rendering 15mm thick in CM 1:4 on fair faces of brickwork or concrete surface and finished fair and even complete all as specified. 24 M&L for rendering 20mm thick in CM 1:4 on brickwork or concrete surfaces and finished even and smooth without using extra cement complete all as specified.Note: WPC shall measured and paid seperately under respective item. 25 M & L forpreparation of newlyplastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified. 26 S&F mild steel framed work for gates with ornamental and intricate design, confirming to Fe 290 Gde-E-165, complete all as specified 27 M&L for framed work such as grills, gratings, etc with ends of bar shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkaways, railings, framework of water tanks and similar work conforming to Fe-290 grade E-165 complete all as specified 28 S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 ,complete allasspecified 29 S&F Fe 410W (Gde E-250) quality-A for roof trusses (framed), trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified. 30 S&FFramed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified. 31 S & F Mild steel, plain, black sheet 1.25 mm thick, in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified. 32 M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description, not otherwise described over 10cm width or girth after preparation complete all as specified. 33 M&L for applying two coats of fire resisting paint on surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth complete all as specified. 34 M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified. 35 M&L for plain cement concrete type C-2, 1:3:6 (40mm graded aggregate) 100 mm thick in flooring complete all as specified. 36 M&L for plain cement concrete type D-2, 1:4:8 (40mm graded aggregate) 100 mm thick as in sub base complete all as specified. 37 M& L for machine pressed precast concrete interlocking paver block, any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade, with grey cement and pigment complete all as specified. 38 M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified. 39 S&F pre- painted Galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any color having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. 40 S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified. 41 Supply only Integral water proofing compound as specified 42 Demolition and breaking up 150 mm bore salt glazed ware, AC or reinforced concrete pipe or any other description complete all as specified and as directed. 43 Demolition and breaking up 110 mm bore salt glazed ware, AC or reinforced concrete pipe or any other description complete all as specified and as directed. 44 M & L for laying of DWCPE sewage pipes 150 mm bore,sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collars complete all as spcified and directed. 45 M&L concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C2 all as specified and directed. 46 M & L for laying of DWCPE sewage pipes 100 mmbore, sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complete all as spcified and directed. 47 M&L concrete bed to 100mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C2 all as specified and directed 48 Demolition of laterite stone or stone boulder masonary,built in cement mortar as old manhole 49 M/L for providing PCC type B1-1:2:4 (using 20mm graded aggregate) in height, coping, kneelers, apex stones, bed plates, including weathering, slightly, rounded or chamfered angles and throating as directed. 50 Dismantling of cast iron work of any description all as directed. 51 S&F Cast iron work grade FG 150, Articles n. exc 5 kgeach unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles complete all as specified. 52 S&F Cast iron work grade FG 150, Articles exc 5 kgeach unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles complete all as specified. 53 Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. 54 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for 55 M&L for precast RCC (1:2:4) type B1 using 20mm graded stone aggregate as in manhole cover slabs etc set in cement mortar (1:4) including use and waste of form work (reinforcement shall be measured and paid for underrelevant item) all as specified. 56 Cutting into existing manholes for connecting new pipes of dia 150mmmaking good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required. 57 S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified. 58 S&F PVC (SWR) bend with bore suitable for 75mm bore pipes all as directed. 59 S&F75mm bore PVC (SWR) junction Single (Sngle T) equal all as directed. 60 Demolition of cementconcrete in ground floors and paving n exc 15cm thickness (below or above ground level) including plinth protection. 61 M&L 75mm thick PCC 1:3:6, type C2 as in plinth protection and in path, surfaces to be finished without using extra cement complete all as specified and as directed. 62 M & L for 100mm thick Cement Concrete type B- 2, 1:2:4 (40mm graded aggregate) asin hardstanding etc. complete all as specified. 63 M&L in repair PVC gully traps size 125x110mm, square or round mouthed, tvpe S complete all as specified.