| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc andmaking good disturbed surfaces of walls, floors etc. and matching with existing surface, complete all as specified and as directed. |
| 2 | M&L for point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade, conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable laid/fixed and including concealed in PVC rigid conduit on walls/ceiling alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC modular boards and platefor mounting switches, sockets, fan regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch, complete all as specified and as directed.NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black).2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 3 | All as peritem No. 2 here-in-before but for one 5 Amp, 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 4 | All as peritem No. 2 above but for one 3 pin socket outlet, 5 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 1.5 sq. mm size |
| 5 | All as peritem No. 2 here-in-before buton independent board. |
| 6 | All as peritem No. 2 here-in-before butfor one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 7 | All as peritem No. 2 here-in-before butfor one light point controlled by 2 way switches. |
| 8 | All as peritem No. 2here-in-before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth forone 15 Amp, 6 pin socket on independent board. |
| 9 | All as peritem No. 2 above but for one 3 pin socket outlet, 15 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 2.5 sq. mm size |
| 10 | S&F modular switch one way, 6 Amp, one module, 230V, complete all as specified and as directed. |
| 11 | S&F modular switch one way, 16 Amp, one module, 230V, complete all as specified and as directed. |
| 12 | S&F modular switch, piano type, 6 Amp, single pole, two way, one module, 230V, complete all as specified and as directed. |
| 13 | S&F modular bell push, 6 Amp, one module, 230V, complete all as specified and as directed. |
| 14 | S&F modular socket, 6A, 3 pin combined 2 module, 230V, complete all as specified and as directed. |
| 15 | S&F modular socket, 6A/16A, 3 pin combined 2 module, 230V, complete all as specified and as directed. |
| 16 | S&F electric door bell, 230 V, multi music type, ISI marked, complete all as specified and as directed. |
| 17 | S&F lamp holder insulated, PVC/polycarbonate /bakelite body, complete all as specified and as directed. |
| 18 | S&F ceiling rose surface bakelite 65x50mm three terminal, complete all as specified and as directed. |
| 19 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990,PVC insulated andunsheathed , FRLS cabledrawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmmcopper conductor cable (multistranded)PVC insulated and unsheathed FRLS cableas earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boardsfor mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch, complete all as specified and as directed.NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black).2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 20 | All as per item No. 19 above but for one 3 pin socket outlet, 5 Amps on same board with other switches complete all as specified. |
| 21 | All as per item No. 19 above but for one 3 pin socket outlet, 5 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 1.5 sq. mm size complete all as specified. |
| 22 | All as per item No. 19 above but for one lightpoint controled by two, two way switch complete all as specified. |
| 23 | All as per item No. 19 above but for one bell point controlled by one bell push complete all as specified. |
| 24 | All as per item No. 19 above but for one 3 pin socket outlet, 5 Amps on independent board with cables, 1.5 sq. mm size complete all as specified. |
| 25 | All as per item No. 19 here-in-before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth for one 15 Amp, 3 pin socket on independent board complete all as specified. |
| 26 | All as per item No. 19 above but for one 3 pin socket outlet, 15 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 2.5 sq. mm size complete all as specified. |
| 27 | S&F switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish, complete all as specified and as directed. |
| 28 | S&F socket outlet, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, complete all as specified and as directed. |
| 29 | S&F switch socket combination, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, complete all as specified and as directed. |
| 30 | S&F switch socket combination, multipurpose, flush type, 2 in 1 type (3 pin ) 6/16 Amps, 230V, AC, complete all as specified and as directed. |
| 31 | S&F lamp holder, angle/ batten type, PVC/Polycarbonate type with back plate, suitable for batten fittings, complete all as specified and as directed. |
| 32 | S&F ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish, complete all as specified and as directed. |
| 33 | S&F bell push, flush type, 6 Amp, single pole, 230 volts, white finish, complete all as specified and as directed. |
| 34 | S&Fbell,AC, 230 volts, single phase, complete all as specified and as directed. |
| 35 | S&F in repairs, MCB, SPN 40 to 63 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs, complete all as specified and as directed. |
| 36 | S&F in repairs, single pole & neutral DB, 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar, complete all as specified and as directed. |
| 37 | S&F in repairs, single pole & neutral DBs, 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar, complete all as specified and as directed. |
| 38 | S&F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way,protection class IP-43with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing, complete all as specified and as directed. |
| 39 | S&F in repairs, MCCBs 4 Pole, 63A, 415V, 16KA,thermal magnetic, complete all as specified and as directed. |
| 40 | S&F in repairs, MCCBs 4 Pole, 100A415V, 16KA,thermal magnetic, complete all as specified and as directed. |
| 41 | Supply and fixing in repairs 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and as directed. |
| 42 | Supply and fixing in repairs amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 Amps in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 43 | Supply and fixing LED round/square shape 6 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed. |
| 44 | Supply and fixing LED round/square shape 12 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed. |
| 45 | Supply and fixing LED round/square shape 15 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed. |
| 46 | S&F in repairs, 600 mm x 600 mm size, ultra slim,recess mounted LEDluminaire of capacity36watt, with driver, for soft glare free light, AC 230 voltcomplete with all acessories and connections, complete all as specified and as directed. |
| 47 | S & F LED Tube light fitting 20 Watt decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, enviromental friendly energy efficiency with LED light source 6000k with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with, complete all as specified and as directed. |
| 48 | S & F LED Tube light fitting 10 Watt decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, enviromental friendly energy efficiency with LED light source 6000k with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with, complete all as specified and as directed. |
| 49 | Surface mounted, decorative round plastic bulk head LED luminaire comprising of high brightness LED\"s, IP54 protection, 10 watt, 6000K complete fitting with LED lamp, driver and all other fixing accessories including electric connection connecting with using flexible copper wire twin core upto ceilling rose/connector including taking down old unserviceable light fitting any type, complete all as specified and as directed. |
| 50 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lampall fittings and accessories, complete all as specified and as directed. |
| 51 | Supply and fixing in repairs post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed.Make :-Crompton LPTO-40-CDL/M or equivalent in Havells/Philips or equivalent |
| 52 | S&F in repairs, security light fitting of building with single piece new generation energy savng and environmental friendly, long life, LED 30W, made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07including one bracket made of light gradeGI Pipe 25 mm dia, 1.5 mtr long, fixed to wall/ pole with two clamps made out of mild steel flat iron 40 mm x 5 mm and connect to nearest electric supply by two core 1.5 sqmm aluminium cable, complete all as specified and as directed.Make : Havells Cat No LHEXAY7PN6K030 or equivalent model of make Philips / Crompton Wipro/Surya |
| 53 | M&L in repairs for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm burieddirectly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 4mm dia GI wire upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etcRCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate)including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009, complete all as specified and as directed. |
| 54 | S&F in repairs, LED edge lit panel drivers of capacity 18 W to 36 W with universal connector for easy installations, complete all as specified and as directed. |
| 55 | S&F in repairs, LED edge lit panel drivers/post top lamp of capacity 42 W with universal connector for easy installations, complete all as specified and as directed. |
| 56 | S&F in repairs PVC casing caping 32 mm with fixing accessories such as complete, lock nuts, saddles hook etc of adequate size, fixed in replacement, complete all as specified and as directed. |
| 57 | S&F in repairs PVC casing caping 100 mm with fixing accessories such as complete, lock nuts, saddles hook etc of adequate size, fixed in replacement, complete all as specified and as directed. |
| 58 | S&F in repairs, PVC rectangular box of 100 mm x 100mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed. |
| 59 | S&F in repairs, PVC rectangular box of 175 mm x 100mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed. |
| 60 | S&F in repairs, PVC rectangular box of 200 mm x 150mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed. |
| 61 | S&F in repairs, PVC rectangular box of 250 mm x 200mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed. |
| 62 | S&F in repairs, PVC rectangular box of 350 mm x 300mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed.Note Cutting of board for mounting switch,sockets, fan regulators etc. shall be as per site requirement. |
| 63 | S&F in repairs, modular cover plate frame, 2 module, complete all as specified and as directed. |
| 64 | S&F in repairs, modular cover plate frame, 4 module, complete all as specified and as directed. |
| 65 | S&F in repairs,modular cover plate frame, 6 module, complete all as specified and as directed. |
| 66 | S&F in repairs, modular cover plate frame, 8 module, complete all as specified and as directed.Note:(i) Item shall be executed to attend day to day complaints.(ii) Burnt/damaged fitting only shall be replaced.(iii) Wiring is not included in the item. |
| 67 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size4 sqmm, two core, complete all as specified and as directed. |
| 68 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size6 sqmm, two core, complete all as specified and as directed. |
| 69 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size10 sqmm, two core, complete all as specified and as directed. |
| 70 | S&F repairs 5/6 Amp plug top 230 volts, single pole, white/ivory finish, complete all as specified and as directed. |
| 71 | S&F repairs 15/16 Amp plug top 230 volts, single pole, white/ivory finish, complete all as specified and as directed. |
| 72 | S&F in repairs, sheet metal enclosureswith plug socket, single pole and neutral with two pin and earth plug with one MCB of 20 Amps (SP), complete all as specified and as directed. |
| 73 | M & L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia PVC conduit conforming to IS-9537 / suitable size casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit, complete all as specified and as directed. |
| 74 | M & L for sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm diaPVC conduit conforming to IS-9537 / suitable size casing caping (ISI marked)with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit, complete all as specified and as directed. |
| 75 | M & L for sub main wiring with 2 runs of 10 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm diaPVC conduit conforming to IS-9537 / suitable size casing caping(ISI marked)with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit, complete all as specified and as directed. |
| 76 | M & L for sub main wiring with 4 runs of 10 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia PVC conduit conforming to IS-9537 / suitable size casing caping(ISI marked)with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit, complete all as specified and as directed. |
| 77 | Taking down of exhaust fan upto 450/300mm sweep, opening, replacement of unserviceable accessories, servicing, oiling, greasing, complete overhauling of fan and re-assembling and testing complete for efficient functioning after fixing / hanging in position from ceiling rose to fan, complete all as specified and as directed.(Note : gun metal bush, bearing will be measured and paid under relavant item here-in-after). |
| 78 | Supply only gun metal bush of sizes suitable for exhaust fan upto 450 mm sweep, complete all as specified and as directed. |
| 79 | Supply only ball bearing No 6203 suitable for fan of existing make type & sweep, complete all as specified and as directed.Make:- NBC/SKF/TATA |
| 80 | Checking of exhaust fan(of any sweep) by replacing unserviceable capacitor/ tightening the loose connections if any including testing, complete all as specified and as directed.(Note: Capacitor of required capacity will be measured & paid under relavent item here-in-after) |
| 81 | M & L for painting of exhaust fan carefully with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc, complete all as specified and as directed. |
| 82 | M&L for shifting of exhaust fan from one place to another including making hole at new place and filling of hole at old place including all necessary electric connection, brick work, plastering and 2 coat of painting of size 150, 200, 250 and 300mm dia, complete all as specified and as directed. |
| 83 | S & F INVETER LED Tube light fitting 20 Watt with square profile and polycarbonate channel. lITHIUM Ion battery with charging time 8 to 10 hrs and back up time upto 4 hrs LED light source 6500k with uniform light output,with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with, complete all as specified and as directed. |
| 84 | S&F in repairs, LED9W Bulb, 230 Volts AC supply, complete all as specified and as directed. |
| 85 | S&F in repairs, LED9WInverter Bulb, 230 Volts AC supply, complete all as specified and as directed. |
| 86 | Taking down unserviceable fitting of any type or any wattage i.e. 100/90/80/72/60/45/30/25 Watt energy efficient street light fitting, identifying the fault, repair / replacement of old unserviceable accessories with newaccessories, reassembling and make the street light fitting functional and refixing in existinglocation including three core copper PVC insulated conductorof 1 sqmm size (nominal area) of suitable length to connect the lumaniries to overhead conductor / existing lines, complete all as specified and as directed.Note : Spares part/material required for repair to street light fitting shall be measued and paid separtely under relevent items as supply only. |
| 87 | Supply only 1100 volts grade heavy duty cable PVC insulated and FR PVC rounded sheathed, copper conductor(flexible) industrial cable, conforming IS: 694 of size 1.5 sqmm 3 core laid along pole from junction box to light fitting, complete all as specified and as directed. |
| 88 | Supply only in replacement of street light driver of 25 watt to 50 watt, 230V,50Hz suitable foroperation over voltage range of 140V to 270V by emoving from existing position, complete all as specified and as directed. |
| 89 | Supply only in replacement of street light driver of 55 watt to 100 watt, 230V,50Hz suitable foroperation over voltage range of 140V to 270V by emoving from existing position, complete all as specified and as directed. |
| 90 | M & L in for DK Thermoplastic cable junction boxes IP 65 with of size 300x200x105 of metric knockouts for cable entry, weather proof for outdoor installationand including glands and with 4 terminals for terminating oneincoming and outgoingUG cable of size 10/16 sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and boltsandincl provn for fixing 01 No. of single pole MCBs 6-32 amps,10KA and MCB TP 6-32 amps, 10 KA, ‘C’ series 01 Noinside the box incl taking down old u/s junction box, complete all as specified and as directed.Make : Sintex/Hensal or equivalentapproved by GE. |
| 91 | S&F in repairs LED street light fittings, IP-66, 70 watt including bracket made out of 40 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape duly fixed with MS clamps of 3mm thick, nut, bolts etc complete fixed to steel tabular poles including electrical connection complete with 3 core 1.5 Sqmm PVC sheathed stranded copper wire ISI marked from junction box to fitting, complete all as specified and as directed.Make Havells, cat part No \"ENDURAOMNIPLUSSL70WLED757SASYTOPC\" or equivalent model of Crompton/Bajaj/Philips |
| 92 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 16 Sqmm, 4 core with XLPE insulated stranded aluminium conductorincluding cablegland, lugs, testingandcommissioning including taking out existing cable alongwith protection covers, complete all as specified and as directed. |
| 93 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 10 Sqmm, 2 core with XLPE insulated stranded aluminium conductorincluding cablegland, lugs, testingandcommissioning including taking out existing cable alongwith protection covers, complete all as specified and as directed. |
| 94 | Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n\"exc. 1.50m deep forfoundationand getting out including forming bottom surface to required level or slope, complete all as specified and as directed. |
| 95 | Returning filling including spreading leveling watering and well ramming in layers not exc 25Cmin soft/ loose soil, complete all as specified and as directed. |
| 96 | Removing excavated material in soft/ loose soil n\"exc 50M and depositing where directed at a level n\"exc1.5M above the starting point, complete all as specified and as directed. |
| 97 | Supply and lay DWC Cable duct pipe of size 40 mm dia confirming to IS : 16205 part 24 for laying of LT cables etc, complete all as specified and as directed. |
| 98 | M&L for painting ofLT structure pole of any size , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level andnumbering of size 70mmx 40mm by using stencil to the pole with black synthetic enemal paint (1st grade), complete all as specified and as directed. |
| 99 | S&F in repair GI Pipes 40mm bore lightgrade in any positionfor protection of cablefixed at pole/laid under road , nallah, crossingwalls under floors etc, complete all as specified and as directed.Make : TATA/BANSAL/JINDAL or equivalent |
| 100 | Supply and fixing of automatic controlpanel (Nature switch) designed for automatic control of night senstive electric circuits using space grade infra -red sensor which auto matically adjusts ON and OFF time as per the seasonal variation of day light independtently of altitude and latitude for Three Phase load complete with contractor MCB and timer upto 32 Amp capcity, complete all as specified and as directed.Make HEALER EnterPrices( Model-Navdeep-54-18KW3P)/ Crompton / L&T. |
| 101 | Dismantling and removing old unserviceable in repairs earthing and material and labour for earthing completewih galvanised steelearth plateelectrode 60cmx60cmx6.00 mm thick burried directly in ground vertically toa depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level connected to and including galvanized iron earth strip of size 32x6 mm by means of bolts, nuts , chucknut, and washer etc , made of GI and connecting to earth test point all as shown as electrical plate to 5 of SSR Pt -1 2009 an as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C-I earthing chamber, precast RCC slab 50 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabricated weight not less than 4 Kg/ Sqm . Funnel with GI watering pipe 20 mm bore medium grade wire mesh test point etc, complete all as specified and as directed. |
| 102 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulatedaluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section in service connections including taking down old unserviceable cable, complete all as specified and as directed. |
| 103 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulatedaluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core nominal cross section in service connections including taking down old unserviceable cable, complete all as specified and as directed. |
| 104 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulatedaluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections including taking down old unserviceable cable, complete all as specified and as directed. |
| 105 | S&F in repairs,NG Series AIO LED solar street light fitting 40 watt is made with high efficiency mono crystalline solar PV module, lithium ferro phosphate battery with in - built BMS technology, high efficacy LED, MPPT solar charge controller with dusk down sensor with aluminium extuded body & is specially programmed to automatically control the dimming and brightness of light, which will increases the backup time,including galvanised steel pole 80mm bore dia 6 m long, embedded in PCC 1:2:4, type B2 concrete, excavation and earthwork, complete all as specified and as directed. |
| 106 | Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment. |