| 1 | Supply and fixing of following ways surface / recess mounting, vertical type, 415 V , TPN, 12 way MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar and mounting 5 A to 32A single pole MCB and 4P 63A Isolator as directed by engineer in charge including all labour material tools and tackles.Make: L & T / Schneider / GE / ABB |
| 2 | Supply, and laying/clamping/drawing of 3.5C X 50 Sqmm 1.1 KV grade LT Cable XLPE insulated & PVC sheathed, armored, PVC overall sheathed multi stranded aluminum conductor Cable conforming to IS 7098 /Part-I as applicable complete, in the existing trench / to pole with existing clamps / through existing HDPE pipe complete as directed by Engineer-in-chargeincluding all labour, and tools.Brands: Finolex/Universal/Gloster / RPG / Havell’s /Polycab |
| 3 | Supply and Wiring for circuit / sub main wiring along with earth wire with the following sizes FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Complete with all labour, material, tools & tackles as directed by engineer in charge. ( 1 RMT = 3runs of 1mtr. length) 2 X 4 sq. mm + 1 X 4 sq. mm earth wireCable Brands : Finolex / Finecab / Havells / PolycabPVC Pipe Brands : SUDHAKAR / PLAZA / MERCURY / RADIANT / AVON PLAST/ MODI |
| 4 | Supply of 2.0 TR 3 star rated Split AC unit with high wall mounted indoor unit and outdoor copper condensing unit, hermetically sealed scroll/ rotary compressor suitable for operating on 230V AC 50Hz. Single phase AC supply on refrigerant R-32 /R-410A and performing cooling ,dehumidify, air circulating, and filteringwith 3 mtrs. of copper piping, insulation kit and 4 mtrs. of 3 core copper flexible cable including cordless remote control etc. as directed by Engr. I/c complete with all material , labourtools & tackles.Make: Bluestar/ Daikin/ Hitachi/ O General |
| 5 | Installation / Removal ofSpilt / Window AC unit including core cutting, as directed by Engr. I/c complete with all labour tools and tackles. |
| 6 | Supply fixing testing of push button type motor starter for AC units along with suitable base complete with all materials tools and tackles as directed by Engr.I/cMake: Anchor / Cona / Millon /MK |
| 7 | Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recesses, including providing and fixing 6 pin 5/6 & 15/16 A modular socket and 15/16 A modular switch connections etc., colour silver grey as directed by engineer in charge including all labour tools and tackles.Brands: ABB / Wipro Artisa /L&T / Siemens / Legrand |
| 8 | Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recesses, including providing and fixing 5/6 A modular socket and 5/6 A modular switch connections etc., colour silver grey as directed by engineer in charge including all labour tools and tackles.Brands: ABB / Wipro Artisa/L&T / Siemens / Legrand |
| 9 | Supply and fixing of Modular blankplate colour silver grey to existing modular switch board as directed by engineer in chargeBrands: ABB / Wipro Artisa/L&T / Siemens / Legrand |
| 10 | Supply, fixing connecting and commissioning of LT, 3 phase and neutral, floor mounted, In door type, thickness of 3 mmwith hinged door of following switch gears of approved brands with necessary 600 amps alluminium bus bar arrangement with IP55 Protection including 10 tank powder coating complete as directed by engineer in charge including all labour tools and material. 1.incomer: 3 pole, 415 V,400 A, 36/35 KA breaking capacity MCCB --- 1no . 2.out goings:4 pole,415 V,250A, 36/35 KA breaking capacity MCCB - 3 nos3. CT operated 0-500 Amps digital ammeter meter for incoming -1No4. Digital voltmeter 0-500V meter for incoming.- 1No5. LED Indications – 15Nos6. Energy meter (Cl.I) – 1 No. at incomer MCCB’s : ABB/ Schnider/ C&S/ L&T /BCH |
| 11 | Supply, fixing connecting and commissioning of LT, 3 phase and neutral, floor mounted, In door type, thickness of 3 mmwith hinged door of following switch gears of approved brands with necessary 600 amps alluminium bus bar arrangement with IP55 Protection including 10 tank powder coating complete as directed by engineer in charge including all labour tools and material.1.incomer: 3 pole, 415 V,400 A, 36/35 KA breaking capacity MCCB --- 1no . 2.out goings:4 pole,415 V,250A, 36/35 KA breaking capacity MCCB - 5 nos3. CT operated 0-500 Amps digital ammeter meter for incoming -1No4. Digital voltmeter 0-500V meter for incoming.- 1No5. LED Indications – 15Nos6. Energy meter (Cl.I) – 1 No. at incomer MCCB’s: ABB/ Schnider/ C&S/ L&T /BCH |
| 12 | Supply, and laying/clamping/drawing of 3.5C X 240 Sqmm 1.1 KV grade LT Cable XLPE insulated & PVC sheathed, armored, PVC overall sheathed multi stranded aluminum conductor Cable conforming to IS 7098 /Part-I as applicable complete, in the existing trench / to pole with existing clamps / through existing HDPE pipe complete as directed by Engineer-in-chargeincluding all labour, and tools.Brands: Finolex/ Universal/ Gloster / RPG / Havell’s / Polycab |
| 13 | Supply and providing of P.C.C. 1:3:6 with 20 mm graded granite as coarse aggregate and river sand as fine aggregate including mixing, depositing in position, tamping, finishing and curing for base/pole concreting, road cutting etc. as directed by Engineer in charge including all labour and tools. |
| 14 | Cutting and removing WBM surface / road / PCC including soiling metal etc., and removing the debris within a lead of 50m complete with all labour tools and tackle as directed by engineer in charge. |
| 15 | Excavation of pit / trenchin Soft /Loose soilof required width and depth for erection of B.G. rail poles / spun poles / struts or for laying HT / LT underground cables, G.I. pipes etc., and refilling the pit / trench and made good to match with the surroundings including cleaning the debris as directed complete alllabourand material. |
| 16 | Supply and Providing, earth station using 3 meters long, 80 mm medium grade G.I. pipe. In a masonry enclosure of duly filling with alternate layers of coal and charcoal complete with GI funnel and covering with PCC cover and conforming to IS 3043 as directed by engineer in charge including all labour and material. |
| 17 | Supply and laying 50 mm X 6 mm G.I strip as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as directed by engineer in charge |
| 18 | Supply and Wiring for light point / fan point / exhaust fan point / calling bell point with2 runs of 1.5 sq.mm+ 1 Run 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit / casing & capping, with Modularswitch. Modular plate colour Silver gray suitable GI .box and earthing the point etc as required. Complete with all labour, including supply of material, tools & tackles as directed by engineer in charge.1) CABLE BRANDS: POLYCAB / FINOLEX / HAVELLS / KEI2) PVC PIPE BRANDS: SUDHAKAR / PLAZA / MERCURY/RADIANT / AVON PLAST/ MODI3) SWITCHES, SOCKETS BRANDS (Premium Quality) : ABB /Wipro Artisa /L&T / Siemens / Legrand/ Schenider |
| 19 | Supply and Wiring for circuit / sub main wiring along with earth wire with the following sizes FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Complete with all labour, material, tools & tackles as directed by engineer in charge. ( 1 RMT = 3runs of 1mtr. length) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireCABLE BRANDS: POLYCAB / FINOLEX / HAVELLS / KEI PVC PIPE BRANDS: SUDHAKAR / PLAZA / MERCURY / RADIANT / AVON PLAST/ MODI |
| 20 | Supply and making end termination with brass compression gland and alluminium lugs for following size of PVC insulated and PVC sheathed / XLPE alluminium conductor cable of 1.1 KV grade as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.3.5C x50 SqmmBrand: Reychem / M-Seal / 3 M |
| 21 | Supply and making end termination with brass compression gland and alluminium lugs for following size of PVC insulated and PVC sheathed / XLPE alluminium conductor cable of 1.1 KV grade as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.3.5 C x 240 SqmmBrand: Reychem / M-Seal / 3 M |
| 22 | Supply and providing of Heat shrinkable Outdoor End termination kit suitable to 3.5 Core 240 Sq.mm 1.1KV grade armoured Aluminium conductor cable as directed by Engr. I/c complete with all materials labour tools and tackles.Brand: Reychem/ M-Seal/ 3 M |
| 23 | Removing the 320 KVA Generator with AMF panel from AOB with out damage to the materialand same as shifting to DLB and install on existing foundation including testing and commissioning, duly connecting the incoming and out going cables. as directed by Engr. I/c complete with all labour tools and tackles. |
| 24 | Remove of LT panel from DLB including disconnecting the incoming and out going cables with out damage to the material and handover to E/m or G/ stores as directed by Engr. I/c complete with all labour tools and tackles. |
| 25 | Removal of old wiring, fans, tube lights and old switch boards, switch gearsetc from DLB building (Ground floor, 1st Floor, 3rd Floor, 4th & 5th Floors) & MMTC Building (Ground & 2nd floor) and handing over old materials to E/M stores. |
| 26 | Supply, laying / Clamping of 50mmPE-100 grade, 10KG/Sq.cm HDPE pipe on wall/ trench as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.MAKES: TULASI/KSP/ SUDHAKAR/ NANDI |
| 27 | Supply and providing of R.C.C. M 30 mixing (cement per M3 of finished concrete) in roof slabs, landing slabs, making pits etc., with 20 mm graded granite metal of approved quality as coarse aggregate and river sand as fine aggregate including mixing, depositing in position, vibrating,finishing and curing, cost of super plasticizer etc., including necessary shuttering as required complete. as directed by Engineer in charge including all labour and tools. |
| 28 | Supply, transportation and fixing of 32-36Watt Recessed / Surface mounting approx.. 600x600mm LED luminaire made of CRCA sheet housing/ Aluminum as per IS: 15885 (Part 2/ Sec 13) : 2012 , with operating voltage range of 150 to 265 Volts AC, P.F > 0.9, Surge protection: 2KV, THD < 10%, efficacy > 120 lumens / watt, CCT: 5700K - 6500K, minimum CRI>70, .etc., (similar to PHILIPS make RC380B LED 42S) complete with earth connection and not less than two years warranty as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.Make: Phillips / Crompton / Wipro /Havells / Jaquar |
| 29 | Supply transportation and fixing of 22-25Watt Recessed / Surface mounting approx.. 220x220mm LED luminaire made of CRCA sheet housing / Aluminum as per IS: 15885 (Part 2/ Sec 13) : 2012 , with operating voltage range of 150 to 265 Volts AC CCT: 5700K – 6500K, minimum CRI>70, .etc., (similar to PHILIPS make RC360B LED 25S) complete with earth connection and not less than two years warranty as directed by Engineer-in-Charge complete with all labour tools, tackles and materials. |
| 30 | Supply and drawing of UTP 4 Pair CAT 6 LAN cable in the existing surface or In PVC conduit as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.Makes: Systimax /Panduit/ Siemond/ Legrand |
| 31 | Supply installation testing and commissioning of 2nos of Cat6 Unshielded RJ45 Keystones Jack Punchdown Type with Collapsable Door Exceed ANSI/ TIA-568-C.2 and ISO/IEC 11801 standards with 2module face plate for Category 6 component performance & Compatible to T568A,T568B wiring pattern and UL-940V0 Rated Plastic &RoHS Compliant as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.Makes: D-Link/ Digisol/ Msys connect/Finolex |
| 32 | Supply and fixing of modular type bell push colour silver grey on existing modular plate as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.BRANDS (Premium Quality) : ABB / Wipro Artisa /L&T / Siemens / Legrand/ Schenider |
| 33 | Supply and fixing of modular type Telephone socket colour silver grey on existing modular plate as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.BRANDS (Premium Quality) : ABB / Wipro Artisa /L&T / Siemens / Legrand/ Schenider |
| 34 | Supply and fixing of calling bell / Buzzer operating voltage 220volts as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.BRANDS (Premium Quality) : ABB / Wipro Artisa /L&T / Siemens / Legrand/ Schenider |
| 35 | Supply & Fixing of 56\" (1400mm) Sweep 5 star rated BLDC (Brush less Direct Current) Ceiling Fan with double ball bearings, input voltage 230V AC converted to 24 V DC, power input not more than 32W, with remote, as directed by engineer in charge.Makes: Atomberg(GV2 )/ Halonix(Plasma) /Havells(Efficiencia Neo) |
| 36 | Supply and fixing of modular type 3A USB Type C charger on existing modular plate as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.BRANDS: ABB / Wipro Artisa /L&T / Siemens / Legrand |
| 37 | Supply and fixing of 20mm medium grade PVC pipe on surface or in recessed including cutting the wall and making good the same with cement plastering in case of recessed conduit as required as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.BRANDS: SUDHAKAR / PLAZA / MERCURY / RADIANT / AVON PLAST/ MODI |
| 38 | Supply Erection ,Testing & Commissioning of 630KVA 11/.433 KV 3 Phase50Hz DYN 11 ONAN typeISI marked copper wound Transformer, with standard accessories, winding temp. rise 45°C/40°Cfirst oil fil, having permissible total loss values not exceeding to 75% of the maximum total loss values for 11 KV as per Energy Efficiency Level-2 at basic insulation level confirming to IS 2026 (Part-I to Part-II)with latest Amdt.and IS 1180 Part-I : 2014with cable box. Off load Tap changer +10% to -10%, etc., complete as per the continuous rating.Make: Schneider/ Kirloskar/ Voltamp/ Esennar/ Toshiba/ KPEL/ Powertech |
| 39 | Erection testing and commissioning of 630 KVA Transformer on existing foundation including connecting the HT supply and LT supply cables etc., as directed by Engineer-in-Charge complete with all labour tools and tackles.(Note: Transformer will be supplied by VPT at free of cost) |
| 40 | Remove the 400 KVA Transformer from DLB with out damage to the materialand same as shifting to MMTC and install on existing foundation including testing and commissioning, duly connecting the incoming HT and out going LT cables. As directed by Engr. I/c complete with all labour tools and tackles. |
| 41 | Supply and Transportation of 3CX95 Sq,mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab /KEI /Polycab / Gloster / RPG |
| 42 | Laying / Drawing / Clamping of 3C x 95 Sqmm HT Cable in existing trench / through pipe / to pole / wall as directed by Engr. I/c complete with all labour tools and tackles.Cable will be supplied by VPT at free of cost. |
| 43 | Supply and fabrication of steel by using suitable flats, angles, channels of required sizes to provide required cross arms, back clamps, support clamps, frames,clamping of cable to existing wall cutting, bolting, riveting, drilling, welding etc. as directed by Engineer in charge. |
| 44 | SITC of 5.0 KVA Stabilizers to work on 170-240VAC with time delay relay and over load protection as directed by Engr.I/cMake: Unistab /V-guard/Real guard/ITL |