| 1 | Taking down carefully aluminium/copper point wiring (light, bell, fan, socket) complete including fixture and fittings such as switches, ceiling roses, regulators, sockets, holder, fittings and terminal box sheets complete, stacking material at site and making good the disturbed surface of walls/ floors to match with existing surface complete all as specified. |
| 2 | M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated, unsheathed, FRLS type, 1100 volts grade,1.5 sqmm copper conductor cableunsheathed as earth continuity cable including concealed pressed steel GI terminal boxes of suitable way with 3 mm thicklaminated sheet (Hylum sheet) cover for mounting of switches, socket, fan regulators, connected to common earth dolly complete all as specified for the following:- (a)One light /fan/bell point controlled by one nos, one way 5/6 Amps switch. |
| 3 | (b)One 3/5 pin socket outlet, 5/6 Amp on the same board controlled by one nos, one way switch. |
| 4 | (c)One 3/5 pin socket outlet, 5/6 Amp, independent controlled by one nos, one way switch. |
| 5 | All as per srl item No 2.00 here-in-before but using cable of size 2.5 sqmm (for phase & neutral) and 1.5 sqmm as continuous earth cable for 15/16 Amps socket outlet, independent controlled by one nos, one way switch complete all as specified. |
| 6 | S&F in replacement of piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC complete all as specified. |
| 7 | S&F in replacement of piano type socket outlet flush type, 5 pin, 5/6 Amps, 230 volts AC multipurpose type complete all as specified. |
| 8 | S&F in replacement of piano type switch socket combination flush type, 3 pin 5/6 Amps, 230 volts AC multipurpose type complete all as specified. |
| 9 | S&F in replacement of piano type switch socket combination flush type , 6 pin, 5/15 Amps, 230 volts AC multipurpose type complete all as specified. |
| 10 | S&F in replacement of ceiling rose 3 terminals, PVC/ polycarbonate /Bakelite, isolated body 230 volts AC, 50 Hz complete all as specified. |
| 11 | S&F in replacement of 25x16 mm medium grade casing caping alongwith its fixing accessories & making good to the disturbed surface to match with the existing surface complete all as specified. |
| 12 | S&F in replacementLED tube light fitting 20/22 watts, 220 volts AC, 1200 mm, with aluminium housing & integrated electronic driver complete with driver with polycarbonate diffuser & thd< 10% including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Make- Havells/Philips/Crompton |
| 13 | S&F in replacement of LED bulk head light fittings of capacity 10W weather proof, anti corrosion wall/ceiling mounted opel colour decorative, round shape with PC cover including 3 core conductor cable for connection complete with all accessories all as specified.. make: Bajaj/Philips/Crompton/Wipro |
| 14 | S&F in replacement of LED tube light fitting 10 watts, box type 230 volts AC suitable for mirror type with high output diffuser 2 feet, decorative type including connecting up with three core flexible copper conductor cable of suitable size complete all as specified. Make: Phillips/Bajaj/Crompton |
| 15 | Supply and fixing of street light with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics for building outside application with system wattage of 60W 230V AC outdoor type with a nominal efficiency 100 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. IP 65/66 with an IK rating of 07. 4 KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance complete all as specified and as directed. Make: Bajaj/Havells/Phillips |
| 16 | Supply and fixing GI Bracket bent to shape fabricated with GI Pipe 40mm dia light grade 1.5m long including mounting clamps nut bolts complete all as specified and directed. |
| 17 | S&F in replacement inverter LED batten 4 feetas per IS 16102 (Part-I &2) with backup time upto 4 hrs hours (battery back up with Li Ion battery ) base cap B22 D, with electronic driver, lumen maintenance for 50000 hours @ 70 insulated cu wire internal wiring and operating voltage from 140 v to 270 V, PF>0.9 system lumen efficacy ≥100 lumen/watt 6500 K, THD < 30% complete all as specified and directed by Engr-in-Charge |
| 18 | S&F LED building security light fitting 35/40 watts 230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistance complete with Integrated solar street light with Lithium Ferro Phosphate battery, solar panel and charger built into the luminaire with pole mounting bracket. Microwave based motion sensor for optimizing battery autonomy all as specified and as directed Make: Philips/Bajaj/havells |
| 19 | Supply only rechargeable torch with a built-in side light with long range , 3000 Mah Li-ion Battery and high brightness including charger for recharging the battery complete all as specified and as directed |
| 20 | Supply and fix exhaust fan made of sturdy engineering plastic 300 mm sweep,complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding including cutting of wall or window to the size of exhaust fan, fixing of fan and make good surface after installation of the exhaust fan complete all as specified and as directed. |
| 21 | Supply and fix exhaust fan made of steel body heavy duty 450 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding including cutting of wall or window to the size of exhaust fan, fixing of fan and make good surface after installation of the exhaust fancomplete all as specified and as directed. |
| 22 | S&F in replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FR type, 1100 volts grade 2 x 4 sqmm complete drawn in existing conduit along with 1x 4.0 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. |
| 23 | S&F in replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FR type, 1100 volts grade 2 x 6 sqmm complete drawn in existing conduit along with 1x 6.0 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. |
| 24 | S&F in replacement of sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing complete all as specified.Make: Havells/L&T/Legrand |
| 25 | S&F in replacement of MCBs, SP, 6-32 Amps, 230 volts,10 kA rupturing capacity, B curve type complete all as specified. Make : L&T/Havells/ABB |
| 26 | S&F in replacement of MCBs, SPN, 32 Amps, 230 volts, 10 kA rupturing capacity, C curve type complete all as specified. Make : L&T/Havells/ABB |
| 27 | S&F in replacement of MCBs, SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, C curve type complete all as specified. Make : L&T/Havells/ABB |
| 28 | S&F for 4 KG ABC fire extinguisher (MAP 90 based portable stored pressure) unique gauge testing system (UGTS) mechanism of IS 15683:2006 standard , brass chrome plated valve with large loop stainless pull pin including wall bracket for hanging complete all as specified and as directed. |
| 29 | Supply and installation of automatic fired based 5 KG ABC fire extinguisher (MAP 90 based portable stored pressure) unique gauge testing system (UGTS) mechanism of IS 15683:2006 standard , brass chrome plated valve with large loop stainless pull pin including wall bracket for hanging complete all as specified and as directed. |
| 30 | Supply only custom vinyl flex banner (with lamination for outdoor use) of size 4\"\" x 3\"\" / 3\"\"x3\"\"/4\"\"x4\"\"with metal frame for support with hanging/mounting provisions with text writtenin a specified font, size, and color as per sample complete all as specified and as directed by engr in charge. |
| 31 | Supply & fixing glow sign board made up of steel sheet of size5feet x 3feet designed for outdoor use with text writtenin a specified font, size, and color. The box must include 4 Nos ofLED lights of capacity 10W each to illuminate the design at night, with a power source provision. It should be durable, weather-resistant , rust and corrosion proof and should have hanging or mounting provisions complete all as specified and as directed by Engr-in-charge. |
| 32 | Demolition of cement concrete (Un reinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 33 | M&L for fabrication , design & laying as directed MS plate with thickness not less than 3 mm including necessary welding/joining work on MS angle complete all as specified and as directed work includes arrangement of gas cutter for cutting of sheets in desirable shapes |
| 34 | M&L for fabrication , design & laying as directed iron angle of size 25x25x4 mm including necessary welding/joining work complete all as specified and as directed work includes arrangement of gas cutter for cutting of iron angle in desirable shape |
| 35 | M&L for 25mm thick PCC Type B-0 1:2:4 using 12.5mm graded crushed stone aggregate finished fair to receive top layer of flooring/trench including maintaining slopes to avoid water accumulation in installation all as specified. |
| 36 | S&F galvanized iron strip 25x4mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints complete all as specified. |
| 37 | S & F earth continuity conductorfixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as GI wire of size 4 mm dia |
| 38 | M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified. |
| 39 | M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing complete all as specified. |
| 40 | Note :- An amount of Rs. 12,620.00on account of credit schedule for Sch \"A\" Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. |