|
| 1 | M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including one coat of aluminium paint over a coat of red oxide zinc chrome primer and providing 03 Nos band/strap with black/yellow colour paint 300mm apart from the plinth block, numbering of pole painting embedded portion of pole with one coat of black bitumenous paint and including dismantling of unserviceable LT steel tubular pole,complete all as specified and directed. (Note : Excavation and Earth work shall be measured and paid separately) |
| 2 | M & L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed. |
| 3 | M & L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 100 mm height 65 mm dia suitable for 1100 volts grade complete all as specified and directed. |
| 4 | M & L for shackle type porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and dia of bolt 14 mm suitable for 1100 volts complete all as specified and directed. |
| 5 | M & L for Stay assembly complete with all accessories as shown in electrical plate No 1 of MES Schedule Part I dia of stay rod 20mm with and including 7 / 3.15 mm galvanised stay strand and including dismantling of old unserviceable stay assembly, complete all as specified and directed.(Note : Loop insulator, excavation & earthwork and cement concrete measured and paid separately under relevant items of this Schedule.) |
| 6 | Materials and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT, 20 x 15 cm size including dismantling of old one complete all as specified and directed. |
| 7 | M & L for galvanised steel earth wire 4 mm dia as continuous earth wire, guards and cradles (hexagonal/rectangular) and including GI binding wire 1.6mm dia and including dismantling of old unserviceael ones, suitable for LT/HT over head line complete all as specified and directed. |
| 8 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing includingtaking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 9 | All as per Serial item No. 8 above but for 16 Sqmm 4 core cable complete ditto |
| 10 | All as per Serial item No. 8 above but for 10 Sqmm 2 core cable complete ditto |
| 11 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose type soil complete all as specified and as directed. |
| 12 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed. |
| 13 | Excavating in trenches not exc. 1.5 metre wide and exc. 1.5 metre & not exc. 3 metre depth (beyond the first 1.5 metre) for foundation of poles etc and getting out in hard/dense soil complete all as specified and directed. |
| 14 | M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) |
| 15 | Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 17 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed. |
| 18 | S & F in repair 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 19 | S & F in repair 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 20 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 21 | M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 22 | M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed. |
| 23 | M & L for Preparation of old painted surface above the planting depth/PCC coping of steel tubular LT pole upto 8.50/9.00 metre long including MS clamps, cable protection pipe, bracket fitted with steet light fittings etc by scraping with steel wire brush and applying one coat of aluminium paint to external surface of poles, MS cross arms, MS clamp, cable protection pipe etc to give even shade including 5 Nos strips painting of 300mm high each around the pole with two different colour (black/yellow) of synthetic enamel paint and numbering of poles complete all as specified and as directed by the Engr-in-Charge. |
| 24 | Supply and fix in replacement synthetic insulating mat recommended for safety of worker, black or blue colour Class A of size 2m x 1m x 12 mm thick, ISI marked complete all as specified and directed |
| 25 | Re-straining and tightening of existing serviceable ACSR conductor of any size without taking down including all arangement and including bindingwire 2 mm dia and colour sleeve Jumpers complete all as specified and directed. |
| 26 | Trimming of tree branches around the overhead conductor, poles & stays (not less than 3 metre) to clear the approach of overhead lines including removing of nest, wild grass creepers, unwanted vegetation, etc from pole/stay including cleaning of creepers climbed on poles and angles, channels and disposed off from site beyond 50m and upto a total distance of 250m complete all as specified and directed by the Engr-in-Charge. |
| 27 | S & F in repairMCCB 63 Amps 3 pole, 16 KA with thermal magnetic, 415 Volts, 50 Hz including outgoing and incoming cable connection and fixing to existing panel board, complete all as specified and as directed. |
| 28 | S & F PVC/fibre separator for LT over head line 1100 volts conductor 2/3/4 wire system for horizontal spacing of conductor complete with nuts and bolts minimum 2 Nos to prevent the line touching each other on heavy wind including taking down old separator complete all as specified and as directed . |
| 29 | S&F in repairs LED ammeter, 0-50 Amps of dial size 96x96mm flush mounting with accuracy class 1.0 single phase, complete all as specified and directed. |
| 30 | S&F in repairs LED voltmeter, 0-500 Volts of dial size 96x96mm flush mounting with accuracy class 1.0 single phase, complete all as specified and directed. |
| 31 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 32 | M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts,check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 33 | Supply, laying, connection and testing 20mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etcand including taking up or down of old unserviceable pipes, complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 34 | Supply, laying, connection and testing 25mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etcand including taking up or down of old unserviceable pipes, complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 35 | Supply, laying, connection and testing 32mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etcand including taking up or down of old unserviceable pipes, complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 36 | Supply, laying, connection and testing 40mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etcand including taking up or down of old unserviceable pipes, complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 37 | Supply, laying, connection and testing 50mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etcand including taking up or down of old unserviceable pipes, complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 38 | Supply, laying, connection and testing 80mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etcand including taking up or down of old unserviceable pipes, complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 39 | Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches and including taking up or down of old unserviceable pipes, complete all as specified and directed.Notes: (a) Excavation and earth work work shall be measured and paid seperately.(b) Cost of T&P and any type of PP-R fittings required at site for branch connections/fixing of water pipe line deemed to be included in the quoted rates by the contractor. |
| 40 | Supply, laying, connection and testing, 32mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches and including taking up or down of old unserviceable pipes, complete all as specified and directed.Notes: (a) Excavation and earth work work shall be measured and paid seperately.(b) Cost of T&P and any type of PP-R fittings required at site for branch connections/fixing of water pipe line deemed to be included in the quoted rates by the contractor. |
| 41 | Supply, laying, connection and testing, 40mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches and including taking up or down of old unserviceable pipes, complete all as specified and directed.Notes: (a) Excavation and earth work work shall be measured and paid seperately.(b) Cost of T&P and any type of PP-R fittings required at site for branch connections/fixing of water pipe line deemed to be included in the quoted rates by the contractor. |
| 42 | Supply, laying, connection and testing, 50mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches and including taking up or down of old unserviceable pipes, complete all as specified and directed.Notes: (a) Excavation and earth work work shall be measured and paid seperately.(b) Cost of T&P and any type of PP-R fittings required at site for branch connections/fixing of water pipe line deemed to be included in the quoted rates by the contractor. |
| 43 | Supply, laying, connection and testing, 63mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches and including taking up or down of old unserviceable pipes, complete all as specified and directed.Notes: (a) Excavation and earth work work shall be measured and paid seperately.(b) Cost of T&P and any type of PP-R fittings required at site for branch connections/fixing of water pipe line deemed to be included in the quoted rates by the contractor. |
| 44 | M & L for Making connection of PP-R distribution branch with PP-R main ofsizes 50 to 75 mm outer dia of pipe by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
| 45 | S & F 65mm bore, cast iron sluice valve, non-rising stem type, both end flanged, class PN 1.6 conforming to IS -14846-2000 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket and including taking out/down unserviceable ones, complete all as specified and directed. |
| 46 | S & F 80mm bore, cast iron sluice valve, non-rising stem type, both end flanged, class PN 1.6 conforming to IS -14846-2000 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket and including taking out/down unserviceable ones, complete all as specified and directed. |
| 47 | S & F 100mm bore, cast iron sluice valve, non-rising stem type, both end flanged, class PN 1.6 conforming to IS -14846-2000 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket and including taking out/down unserviceable ones, complete all as specified and directed. |
| 48 | S & F in repairs 20 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 49 | S & F in repairs 25 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 50 | S & F in repairs 40 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 51 | S & F in repairs 50 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 52 | S & F in repairs 25 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed. |
| 53 | S & F in repairs 32 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed. |
| 54 | S & F in repairs 40 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed. |
| 55 | S & F in repairs 50 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed. |
| 56 | S & F in repairs 63 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed. |
| 57 | Supply only High strength calcium Hypo Chloride, 65-70% chlorine content, Calcium based granular disinfectant for water treatment chemical complete all as specified and directed. (Note: Make shall be as per approved makes of E-in-C. Testing certifcate of chemical shall be submitted by the contractor before supply). |
| 58 | Supply only Lime for water treatment chemical complete all as specified and directed. |
| 59 | Supply only Alum Crystal for water treatment chemical complete all as specified and directed. |
| 60 | M & L for Dewatering Water from Pressed Steel Storage Water Tank 40000 Litre Capacity, having 15.00 Metre High Steel Stagging, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls & Floor of Water Tank, Removal of Dirty Water with Sludges and disposed off from the Site as diredted, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters \"TANK CLEANED ON : DD.MM.YYYY\" (i.e. Date of Cleaning), exc. 100mm but not exc. 200mm in height and 15mm in wide with White Paint on Black Back ground on the Front/ Road Side/Face of the Tank, complete all as specified and as directed.(NOTE :-(a) Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Steel Storage Water Tank will be arranged by the Contractor at his Own Arrangement & Cost and the same will be included in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.) |
| 61 | Supply only Chlorine Test Kit with colour ample complete with all testing fitments and OT solution in rexene finish box complete all as specified and as directed. |
| 62 | Supply only OT solutionfor chlorine test (500ml) complete all as specified and as directed. |
| 63 | M & L for Taking out existing Monoblock Pump set, 7.5 HP capacity after disconnecting all electrical connections, Opening strip of pump set and removing Mono block Pump set to AGE E/M Store yard, opening and checking, cleaning of pump set as required, transportation of defective Pump set to nearest workshop to carry out reparing/rewinding, dismantling pump set, taking out burnt copper windings, cleaning of slots of the motor, re-winding the same with supper enamlled copper insulated wire of suitable gauge and weight as per the existing one including necessary insulation materials, varnishing, heating, replacement of minor spares/ parts such as nuts, bolts, washer, gasket etc and repalcement of ball bearings etc with new one as per the existing one, greasing etc re-assembling the same and testing for smooth functioning after re-winding, transporting back to worksite after repair, re-installation and providing all connection, testing in presence of Engr-in-Chargecomplete all as specified and diretced. (Note: Ball bearing etc as required shall be measured and paid seperately as supply only under relevant item) |
| 64 | Supply only Ball bearing suitable for Monoblock Pump set, 7.5 HP capacity complete all as directed (Make : TATA/SKF/NBC/HCH). |
| 65 | Supply only Cast Iron impeller CI KDS-3 suitable for 7.5 HP capacity motor as existing specifications complete all as directed |
| 66 | M & L for lifting of Submersible Pump and Motor assembly 10 HP capacity alongwith complete Column pipes. Submersible cable, safety rope etc from the existing Borewell by emplying chain pulley block etc, dismantling column pipes by opeining nuts, bolts, pump & motor etc, seggregating & stacking of serviceable column pipes & other materials and keep in safe custody for re-use complete all as specified and diretced. |
| 67 | M & L for removing submersible pump and motor assembly 10 HP capapcity to AGE E/M Store yard, Opening/dismantling and checking in presence of a Board of Officers to ascertain the quantum of defects and repair works involves, cleaning of cover and parts as required, transportation of defective submersible pump and motor assembly to nearest workshop for repairs, repairing and replacement of unserviceable parts and re-assembling submersible pump and motor assembly after repair and servicing and transporting repaired submersible pump motor assembly back to work site complete all as specified and diretced.(Note: (a) Spare Parts required to be replace will be measured and paid as \"Supply only\"under relevent items and the cost of labour element involved for replacement of parts shall demmed to be included in the unit quoted rate.(b) Any Minor repairs involved to make the submersible pump and motor assembly functional, even if not notified by the BOO, the same shall be carry out by the contractor without any extra cost to the Department.(c) The cost of minor spares parts/ items viz, nuts, bolts, washer, gasket etc shall deemed to be included in the unit quoted rate.(d) Rewinding of submersible motor, herever involves will be measured and paid seperately under relevent item(e) BOO shall be detailed by GE) |
| 68 | M & L for dismantling of Submersible Motor 10 HP capacity, taking out burnt windings, cleaning of slots of the motor and Rewinding the same with water proof super enamelled copper insulated wire of suitable guage and weight as per the existing one including necessary insulation materials, varnishing, heating, reassembling the same and testing for smooth functioning after rewinding complete all as specified and directed by the Engr-in-Charge. |
| 69 | M & L for Lowering down of Submersible Pump and Motor assembly 7.5 HP capacity alongwith complete Column pipes. Submersible cable, safety rope etc from the existing Borewell by emplying chain pulley block etc,and T & P, testing on completion complete all as specified and diretced. (Note: Serviceable pump repaired under serial item No. 84 to 86 above shall be reused) |
| 70 | Supply only PVC insulated, sheathed, flat stranded copper conductor of 10 Sqmm, 3 core, 1100 Volts Grade conforming to IS:694 water proof submersible cable cable complete all as specified and directed. |
| 71 | S & F in repair Direct Online starter in sheet steel enclosure, 10 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed. |
| 72 | M & L for construction of brick masonry valve pit of size 75 cm x 75 cm x 90 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3.15mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document.However, the same can be seen in GE/AGE E/M office during working hours) |
| 73 | Taking up or down Steel Tubing/PP-R pipe 20mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use/credit, complete all as specified and as directed. |
| 74 | Taking up or down 25 or 32 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 75 | Taking up or down 40 or 50mm bore, Steel tubing/PP-R pipe and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 76 | Taking up or down 80/63mm bore, Steel tubing/PP-R pipe and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 77 | M&L for dismantling / demolition unserviceablePrestressed Cement Concrete (if required on ground) / LT Steel Tubular Pole of any description and any size after taking proper electric shut down from the concerened JE(E/M) / Engr-in-Charge. On demolition / taking out of old electric pole will be kept aside in safe custody to issue under schedule of credit. The job includs made good to the disturbed ground surface area, complete all as specified and as directed.NOTE : Unserviceable pole will be dismantled at ground level and disturbed ground will made good as directed for which earthwork, demolition Cement Concrete, etc. will not be measured and paid separately. |
| 78 | M&L for taking down unserviceable/rusted GI Earth Wire, Cradles Guards of any size and shape at any Position from LT Electric Poles of any size and capacity, complete all as specified and as directed. |
| 79 | M&L for dismantling LT stay assembly complete of any description, complete all as specified and as directed.NOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which. Earth Works, demolition of Cement Concrete etc. will not be Measured & Paid separately. |