| 1 | Supply, installation and testing Air cooled Inverter based split AC 1.5 TR unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C± 3 in cooling mode) Air conditioner will have following conditons :-(a) Refrigerant - R-410 a/R-32(b) EER-5 Star Rating(c) Tonnage - 1.5 TR(d) Indoor Noise level - Not more than 40 Db(e) Filter - As recommended by OEM(f) Remote As recommended by OEM including 02 Nos remote bty(g) Temp display, turbo mode and auto swing facilityAll specification will be as per IS-1391 (Part 2) and latest amendments |
| 2 | Supply, installation and testing Air cooled Inverter based split AC 2.0 TR unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C± 3 in cooling mode) Air conditoner will have following conditons :-(a) Refrigerant - R-410 a/R-32(b) EER-5 Star Rating(c) Tonnage - 2.0 TR(d) Indoor Noise level - Not more than 40 Db(e) Filter - As recommended by OEM(f) Remote As recommended by OEM including 02 Nos remote bty(g) Temp display, turbo mode and auto swing facilityAll specification will be as per IS-1391 (Part 2) and latest amendments |
| 3 | Note for Item No 1 and 2: The cost of following items deemded to be included in quoted rate.(a) Copper pipe duly insulated between indoor/outdoor unit upto length 10mtr for each unit(b) MS Bracket for outdoor unit duly power coated with fixing arrangement.(c) Making of hole in walls including civil work, sleeves and making good to the disturbed surface/wall as per existing sarface.(d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge(e) PVC round sheathed copper cable of suitable size for connecting Indoor and outdoor unit upto supply point as per site requirement(f) Contractor will submit manufacturer\"s warranty certificate to the GE. |
| 4 | Supply, installation, commissioning of Water cooler partially stainless steel, electric driven single phase having approx storage capacity 80 Ltrs and nominal cooling capacity 40 Ltrs complete with all accessories complete all as specified and directed.Note: Contractor will submit manufacturer\"s warranty certificate to the GE. |
| 5 | Supply, installation, commissioning of Glass Top Deep Freezer double door storage capacity 320 Ltrs, single phase 240 volt, 50 Hz complete with all accessories complete all as specified and directed.Note: Contractor will submit manufacturer\"s warranty certificate to the GE. |
| 6 | Supply, installation, testing and commisioning of refrigerator double door storage capacity 270 Ltrs 5 star rated, single phase, 240 Volt, complete all as specified and directed. Note: Contractor will submit manufacturer\"s warranty certificate to the GE. |
| 7 | Taking down complete AC of capacity 1.5/2.0 TR including disconnecting all electrical connection, copper piping and deposit to MES store yard complete all as specified and directed. |
| 8 | Supply and installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180V to 250V with voltage stabilzer at 230V with Digital display, accuracy of (+) 2.5% and capacity 4 KVA complete all as specified and directed. |
| 9 | Taking down old unsv sub main wiring and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC conduit of size19/20 mm (ISI marked) including PVC accessories (conduit on wall complete includingmaking good to disturbed surface etc)completeetc including one run of 6.00 Sqmm single core copper conductormulti-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Two run of 6.00 Sqmm cable and one run of 6.00Sqmm earth wire & 20 mm PVC conduit shall be measured as one unit length complete all as specified and directed. |
| 10 | Supply and fixing sheet metal enclosure with socket and plug top single pole and neutral enclosure with two pin and earth plug and socket complete with one MCB 20-25 Amp \"C\" series single pole complete with connection complete all as specified and directed. |
| 11 | Supply & fixPrewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link complete all as specified and directed. |
| 12 | Supply and fix MCB single pole and neutral (SP&N) 40 to 63 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified and directed. |
| 13 | S&F MCB single pole (SP) 20 to 25 Amp 240 Volts 10 KA \"B\" series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed. |
| 14 | Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 25 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands complete all as specified and directed. Note: Excavation and earthwork will be measured and paid separately under respective items herein |
| 15 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M indepth for pipe line, etcgetting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified and directed. |
| 16 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete all as specified and directed. |
| 17 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 18 | Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioningas in trenches 8 cm depth below cable and 15cm above cable andpunned to 10cm depthcomplete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose. |
| 19 | M&L brick, sub class \"B\" bricks laid dry, flat, length equal to width of brick over sand cushioning in trenches for cable protection complete all as specified and directed. |