| 1 | Dismantling and taking down unserviceable UG cable of any size all as specified and directed. |
| 2 | Dismantling and taking Out existing unserviceable/demaged LT Feeder piller box complete all as specified and directed. |
| 3 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable/foundation of pole and stay etc and getting out in Soft/loose soil complete all as specified and as directed. |
| 4 | M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 95sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testingincluding disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:-Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately. |
| 5 | All as per item No. 4 here-in-before but cross-sectional area 50 sqmm, 3.5 core complete. |
| 6 | All as per item No. 4 here-in-before but cross-sectional area 25 sqmm, 3.5 core complete. |
| 7 | All as per item No. 4 here-in-before but cross-sectional area 16 sqmm, 4 core complete. |
| 8 | All as per item No. 4 here-in-before but cross-sectional area 16 sqmm, 2 core complete. |
| 9 | Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand all as specified and as directed (Compacted thickness shall only be measured and paid) |
| 10 | Material and labour for well burnt bricks,Sub class \"B\" bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed |
| 11 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed |
| 12 | Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed. |
| 13 | M&L for GI pipe 80 mm dia \"light grade\" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed . |
| 14 | All as per Srl item No 15 here-in-before but 50mm dia |
| 15 | All as per Srl item No 15 here-in-before but 40mm dia |
| 16 | Supply, installation, testing and commissioning weather proof outdoor type LT electrical feeder piller box, factory fabricated and CPRI approved, made out of not less than 3mm thick CRCA sheet, vermin/ dust / weather proof with rain protection canopy on top, aesthetically designed, having at least IP-54 protection with front and rear side openings overall size900 x 600 x 300mm including busbar chamber, contineous earth busbar,Aluminium strip600 mm long of size 200 A rating mounted on 1100 V epoxyinsulators and including MS angle iron base frame of size 50x50 x6 mm 30 cm grouted in ground & 60 cm above GL with necessaryexcavation, PCC 1:2:4, type B2 foundation, complete with locking arrangement, powder coated inpostmen red color shade chemical for rust protection completewith electrical wiring, Note: 1100V Danger notice board on front of the panel with PVC insulated sheathed stranded aluminium conductor cable of adequate size with suitable lugs, bolts, washers and duly cross marked with paint on front side and with proper locking arrangement complete connecting incoming & outgoing connectionsthe panel shall be complete with instrumentation such as metering & indicationand CT\"s, comprising of the following:-(a) MCCB 4 Pole, 400 Amp, 36 KA 01 No (Incoming)(b) Multifunctional meter (Voltmeter and Ampere Meter sutaible size or capacity) - 01 No (c) CT\"S 4000/5 - 01 Set(d) Indicator lamp RYB - 01 Set |
| 17 | M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth lead wire4 mm dia by means of bolts, nuts,check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dia and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and alsoremoval of excavated soil not less than 50 mtr from the earthing place all as specified and directed and tested on completion. including testingall as specified and directed by E-in-Charge. |
| 18 | Material and labour for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in cement mortar 1:4 for coping incl necessary formwork complete all as specified and directed. |
| 19 | S&F Air termination single pointed ,copper rod 12mm dia and 300mm long including necessary fixing arrangement using MS clamps ,nuts & bolts complete all as directed and specified. |
| 20 | M&L for Earthing complete with copper plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20x3mm up to 7.5 mtr by means of nuts, bolts, check nuts, washers of tinned brass,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering,including charcoal or coke and salt in alternate layers and filling earth pit with fresh vegetable soil below copper plate and above upto ground level as required andnecessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed.(Note:i)Charges for earth resistivity test deemed to be included in the quoted rate.ii)Earth resistance value shall be less than 1.0 Ohm) |
| 21 | S&F copperstrip 20x3.15 mm fixed on suitable size porcelain insulator and srews/nuts/washers forextension ofroof conductor or down conductor above ground on wallcomplete all as specified and directed. |
| 22 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in copingas in repair of existing damaged PCC Block.complete all as specified and directed. |
| 23 | Fixing of old GI/Aluminium /Copper earthing strip for roof conductor or down conductor of any size with saddles and screws complete all as specified and directed. |
| 24 | S&F GI pipe ,medium grade 32 mm dia bore for installation of air termination rod all as required and directed. |
| 25 | Supply & Fix Test point terminal block made of gun metal or phosphorus bronze size 75X75X25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. Head screw. |
| 26 | M&L for Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 4.0 Sqmmdrawn into and including PVC concealed conduit\"ISI marked\" of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steelsunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite \"hylam\" laminated sheet cover complete with all accessoriesincluding single core FRLS PVCinsulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dollyfor one 3/5pin socket outlet 15 Amps independent using proper colour coding, complete all as specified & directed. |
| 27 | Supply, installationand testing of water heater storage type (Geyser), single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 50 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, inner tank coating of ferro glass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protectionconsist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners - 04 Nos, hot & cold water metallic flexiblepipes 15 mm bore of adequate length as provided by OEM or required at site - 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safeplug with all protection features as per OEM design and standard, completeall as spcified & directed. |
| 28 | Supply and fixing switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal, complete all as specified & directed. |
| 29 | Supply and fixing factory made epoxy powder coated distribution board, SPN, 2 ways (SPN MCB DB) with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable forONE SPN MCB DBincomer andMCB outgoing, including taking down old unserviceable distribution board,complete all as specified & directed . |
| 30 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of SPNand current carrying capacity 5 to 32 AMP, in the MCB DB Complete with two nos blanking plate with connection testing andcommissioning complete all as specified & directed. |
| 31 | M&L for cutting & screwing of existing water supply line of 15mm bore for alterations or additions (or lengthening screw on pipe to form connector) including fittings,testing after completion, complete all as specified & directed. |
| 32 | Supply and fixing galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, completeall as specified and directed. |
| 33 | Supply and fixing Galvanized iron water tubing, medium grade, 25mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, completeall as specified and directed. |
| 34 | Material and labour for point wiring concealed type for one light controlled by modular switch with 1.5 Sqmm FRLS PVC insulated unsheathed single core multi-stranded copper conductor cable 1100 Volts grade confirming to IS 694 drawn through and including concealed in wall rigid non-metallic ISI marked PVC conduit(medium grade) ofsize 20mm diaconfirming to IS 9537(Part-3) and ISI marked along with 1.5 sqmm continuous FRLS PVC insulated unsheathed single core multi-stranded copper conductor cable for earth continuity wire confirming to IS 694, drawn in same conceled conduit, connected to earth dolly and to be terminated in modular MS steel boxes for mounting switches, sockets, bell push,fan regulators etc including testing on completion complete making good disturbed surface all as specified and as directed by the Engineer in charge |
| 35 | Supply and fix ofSwitch piano flush type single pole, one way 5 Amp , all as specified. |
| 36 | Supply and fix of Ceiling rose surface bakelite three terminals 240 volts complete, all as specified. |
| 37 | Exhaust Fan metallic body, 300mm(12\") sweep, single phase, 230 volts 50 Hz AC,1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including making holes in wall,plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed. |