| 1 | M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in copping and filling in back of chowkatthe like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 2 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. (Pidiproof of Dr.fixit or equivalent) |
| 3 | S&F 35mm thick 2nd class hard wood glazed and skeleton factory made shutter open rebated and prepared to receive glass, gause etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers edges of framing plain chamferred or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR part-I, Sec-08, Clause 8.20(a), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 4 | S&F 35mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 5 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc. 1.5sqm each, including cutting holes for removing the hold fast,making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 6 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, including cutting holes for removing the hold fast, making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 7 | Taking down old unserviceable shutters of any description exc 1.00 but n.exe 2.00 Sqm each complete all as specified and directed. |
| 8 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heatm moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain/decorative colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement in the frame at site as per specification & drawing. etc complete all as specified and directed. |
| 9 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawingcomplete all as specified Make : Rajshree/Sintex/H2O solution.Note:-The door frame to be fixed to wall using 8 x 100 mm long anchor fasteners. |
| 10 | S&F 200mm aluminium anodised barrel tower bolts of extruded sectioncomplete all as specified and directed. |
| 11 | S&F 300 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) andfixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and direcetd. |
| 12 | S&F 100mm Butt hinges, extruded alu minium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed. |
| 13 | S&F 150mm size aluminium handle cast typecomplete all as specified and directed. |
| 14 | M&L for 1.25mm thickpressed steel door frame of size 165mm x 60mm with one or more rebates including necessary , hinges, lock strike plate, fixing lugsetc complete as specified. |
| 15 | M&Lfor 1.25mm thickpressed steel door frame of size 105mm x 60mm with one or more rebates including necessaryfixing lugs , hinges, lock strike plate etc complete all as specified and directed. |
| 16 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 17 | M&Lfor preparation of untreated new wood/wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 18 | M&L for one coats of synthetic enamel painton oldtreated steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 19 | M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 20 | S&F in repair 110mm PVC (SWR)pipes single socketed in any length with rubber ring joints fixed to wallscomplete all as specified and directed. |
| 21 | S&F110mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 22 | M&L for preparing plastered or unplastered old surface of walls including brooming down or scrapping down with steel wire brushes, smoke soot, moulds, moss efflorescent salts and trading oil and greasy spots and applying one coat of white (Lime) wash on wall complete all as specified and directed. |
| 23 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 24 | M&L forrendering 15 mm thick in two layers 10mm +5mm in cement mortar 1:4 on external surfaces of brick work or concrete surfaces with using WPC finishing the surfaces even and smooth without using extra cement complete all as specified and directed.Note:- WPC will be measured and paid separately under respective item of this schedule. |
| 25 | M&L for 5mm thick rendering in cement mortar1:3 over/soffit of chajja/ceiling, finished surface even and smooth without using extra cement complete all as specified and directed. |
| 26 | M&L for 01mm thick wall care putty on wall including preparation of surface with sand paper etc. to obtain smooth surface complete all as specified and directed. |
| 27 | M&L for complete removal of old plastered surface of walls and applying two coat of oil bond distemper white or any tint over a coat of primer etc complete as specified and directed. |
| 28 | M&L for applying two coat of white washing (Lime wash white) including prepration of old decorated plastered/ unplastered surface of walls by brooming down, scraping, cleaning and removing smoke soot, moulds, moss and efflorescence complete all as specified and directed |
| 29 | M&L for preparing old plastered surface of wall and applying one coat of cement base paintby brooming down, scraping, cleaning and removing smoke soot, moulds, moss and efflorescence complete removal of existing treatment complete all as specified and directed. |
| 30 | M&L for applying one coat of oil emulsion distemoer (oil bound distemper) of any tint including preparation of surfaces of walls on old decorated plastered/unplastered surfaces by washing/rubbing down and scrapping old loosematerial,smoke,soot,moulds,moss and efflorence etc including filling and stopping the rough surface/nail holes with white cement/POP/wall putty complete all as specified and directed. |
| 31 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkai registant primer complete all as specified and directed. |
| 32 | M&L for preparing of old existing surfaces and stopping of distempered and painted surfaces and applying two coat of cement based paint (any tint) over a coat of alkali resisiting primer paint on walls complete all as specified and directed. |
| 33 | M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distember over a coat of primer white or any tint over 1mm thick wall care putty complete all as specified and directed. |
| 34 | M&L for preparation of new undecorated surface of walls and applying two coats of white wash complete all as specified and directed. |
| 35 | M&L for preparation of new undecorated surface of ceiling and applying two coats of white wash complete all as specified and directed. |
| 36 | M&L forapplying one coat of white washing (Lime wash white) on ceiling surfaces including preparation of old decorated plastered /unplastered surface of ceiling by brooming down,scrapping cleaning & removing down smoke soot, moulds, moss and efflorescence etc complete all as specified and directed. |
| 37 | M&L for preparing of old existing treament and stopping of distempered and painted surfacesand applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over prepared surfaces complete all as specified and directed. |
| 38 | Comprehensive repair/maintenance of storage type electric water heater (Geyser ) vertical or horizontal type of capacity 50 Ltrs comprising of the following :-(a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank.(b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the washers/gasket nut etc.(c) Checking and rectify earth continuity of the Electrical circuits of the Geysers and power point.(d) Checking thermostat and re-adjust. (e) De-scaling the immersion type heating element. (f) Checking of indicator lamp for it serviceability .(g) Re-assembling the Geyser, re-install and testing complete.Note : Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under respective item of this scheduleas supply only and labour charges required for replacement are deemed to be included in the quoted rate. |
| 39 | Comprehensive repair/maintenance of storage type electric water heater (Geyser ) vertical or horizontal type of capacity 25 Ltrs comprising of the following :-(a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank.(b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the washers/gasket nut etc.(c) Checking and rectify earth continuity of the Electrical circuits of the Geysers and power point.(d) Checking thermostat and re-adjust. (e) De-scaling the immersion type heating element. (f) Checking of indicator lamp for it serviceability .(g) Re-assembling the Geyser, re-install and testing complete.Note : Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under respective item of this scheduleas supply only and labour charges required for replacement are deemed to be included in the quoted rate. |
| 40 | Supply only thermostat of Type EST 11 inch, 20A, 240 volts, AC of approved makecomplete all as specified and directed. |
| 41 | Supply only thermostat of Type EST7 inch, 15A, 240volt, AC of approved makecomplete all as specified and directed. |
| 42 | Supply only heating elements of capacity 2 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/ triangular/ circular base or ceramic cartige type), complete all as specified and directed. |
| 43 | Supply only PVC insulated PVC sheathed flexible round stranded copper wire 2.5 sqmm, 3 core complete all as specified and directed. |
| 44 | Supply only safety valve suitable for 25 Ltr/50 Ltr geyser complete all as specified and directed. |
| 45 | Supply only stainless steel apparatus plate suitable for 50 ltrs capacity geyser as per existing size and nos of hole complete all as specified and directed. |
| 46 | Supply only stainless steel apparatus plate suitable for 25 ltrs capacity geysers as per existing size and nos of hole complete all as specified and directed. |
| 47 | Supply and fixing in repair heating elements of capacity 2 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/ triangular/ circular base or ceramic cartige type) on site without taking down water heater on day to day complaint complete all as specified and as directed. |
| 48 | Supply and fixing in repair thermostat of Type EST 11 inch, 20A, 240 volts, AC of approved make on site without taking down water heater on day to day complaint complete all as specified and as directed. |
| 49 | Supply and fixing in repair thermostat of Type EST7 inch, 15A, 240volt, AC of approved make on site without taking down water heater on day to day complaint complete all as specified and as directed. |
| 50 | Supply and fixing in repair safety valve suitable for 25 Ltr/50 Ltr geyser complete all as specified and directed. |
| 51 | Supply and fixing in repair stainless steel apparatus plate suitable for 50 ltrs capacity geyser as per existing size and nos of hole complete all as specified and as directed. |
| 52 | Supply and fixing in repair stainless steel apparatus plate suitable for 25 ltrs capacity geysers as per existing size and nos of hole complete all as specified and as directed. |
| 53 | Supply and fixing in replacement switch socket combinationmultipurpose 3 pin 15 amp flush typeall as specified and as directed. |
| 54 | Supply and fixing in repair plug top 3 pin, 16 amps complete all as specified and directed. |
| 55 | Supply and fixing in repair plug top for earth plug socket C-Curve complete all as specified and directed. |
| 56 | Supply and fixing in repair metal earth plug socket enclosure with top and MCB SPN 32 Amps 10 KA, C curve includingtaking down old unserviceable one complete all as specified and directed. |
| 57 | Supply and fixing in repair indicating lamp LEDNeon type, 240 volt AC suitable for 25/50 ltrs capacity Geyser complete all as specified and directed. |
| 58 | Supply and fixing in repair chromium plated connecting pipe for hot water/cold water of length upto 60cm long, including two connecting nut with gasket and connecting up complete all as specified and directed. |
| 59 | Supply and fixing in repair PVC connecting pipes with brass adapter 450mm long complete all as specified and directed. |
| 60 | Supply and fixing in repair non return valve 25mm dia size as per site requirement complete all as specified and directed. |
| 61 | Supply and fixing in repair anchor bolt of size 10mm dia and 100mm long bolt including, nut, washer for mounting the geyser complete all as specified and directed. |
| 62 | M&L for Servicing, repair and maintenance of Solar water heater plant of Cap 100/150/200/300 ltrs installed at single/duoble/triple story bldgs for carrying out minor leakage, cleaning of flat plate collector glass, de-scaling of copper tube through approved chemical (Scalgun saf Liquid cleaning) incl necessary tool and equipments for pumping arrangenmentlike pump etc. cleaning of water tank and make up tank including dismantling inlet and out let connections and refixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified and directed. |
| 63 | Supply and fixingin replacement flat plate collector size approx 1860 mm x 1240mm x 90 mm ISI markedas per site requirement assembly suitable for solar water system of existing size and capacity with copper tube black coat/radiation reflector film , toughed glass, complete all as specified and directed.Make:-Supreme /venus/inter solar/umang/sunzone. Note :All the T & P arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and the cost is inclusive in qouted rate. |
| 64 | Supply and fixingin replacementsolar toughened glass plate suitable for collector plate of size approx 1860 mm x 1240mm x 90 mmas per availlability at site complete all as specified and directed. Note:All the T & P arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and the cost is inclusive in qouted rate. |
| 65 | Supply and fixing in repair nytryl rubber suitable for Solar water heater plant of Cap 100/200/300 ltrs for Solar water heater plant complete all as specified and as directed. |
| 66 | Supply and fixing in replacement Solar water heating element for geysers 2 KW, 230 volts AC any type ISI marked complete with rubber gasket including replacing the bolts/screw if any broken during changing the heating elements complete all as specified anddirected. |
| 67 | Supply and fixing in replacement Solar water heating element for geysers 3 KW, 230 volts AC any type ISI marked complete with rubber gasket including replacing the bolts/screw if any broken during changing the heating elements, complete all as specified anddirected. |
| 68 | Supply and fixing in replacement temperature gauge steam type range 25 to 90 degree and above in centigrade as per existing size, complete all as specified and directed. |
| 69 | Supply and fixing for replacement of insulated water tank made out of 1.25 mm thick MS sheet with provision of 15 mm dia inlet/outlet arrangement for solar water heater capacity 200 ltrscomplete all as specified and directed.Make:-Supreme /Venus/Inter solar/Umang/Sunzone.Note:All the T & P arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and thecost is inclusive in qouted rate. |
| 70 | Supply and fixing in replacement of insulated water tank made out of 1.25 mm thick MS sheet with provision of 15/20 mm dia inlet/outlet as per ground arrangement for solar water heater capacity 300 ltrs complete all as specified and directed. Make:-Supreme /Venus/Inter solar/Umang/Sunzone.Note:All the T & P arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and thecost is inclusive in qouted rate. |
| 71 | M&L for replacement of rubber hose pipe 22 to 25 mm dia between hot water tank & collector as per ground requirement complete all as specified and directed |
| 72 | Supply and fixing in replacement top cover suitable for HDPE tankcap 100 to 500 ltrscomplete all as specified and directed. |
| 73 | Supply and fixing in replacement of 500 ltrs ISI marked, rotational moulded polyethlene cylindrical vertical water storage tanks conforming to specification of IS:12701-1996 with amendment No 1 covered by fig 1) hoisted and fixed in position, including disconnecting old tank, complete all as specified.Make : Sintex/Polycon/Fusion. Note:All the T & P arrangement required for carrying/Displacing material from ground to triple storage building shall be arranged by contractor at his own cost and the cost is inclusive in qouted rate. |
| 74 | Supply and fixingcross arms, bracings supports, clamps and back plates fabricated from structural steel sections including nuts bolts, washers, welding bending cold or hot,drilling holes for bolts in any shape or size as indicated or directed and inclusive two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed |
| 75 | Supply and fixing in replacement CPVC pipes SDR11 with plain CPVC SDR 11 fittings and fixed to walls & ceilling or laid in floors, bore of pipe 20 mm complete all as specified and directed. |
| 76 | Supply and fixing in replacement GI tubing medium grade with all fitting and fixed to walls & ceilling or laid in floors, bore of pipe 15 mm complete all as specified anddirected. |
| 77 | Supply and fixing in replacement GI tubing medium grade with all fitting and fixed to walls & ceilling or laid in floors, bore of pipe 20 mm complete all as specified anddirected. |
| 78 | Supply and fixing in replacement GI tubing medium grade with all fitting and fixed to walls & ceilling or laid in floors, bore of pipe 25 mm complete all as specified anddirected. |
| 79 | Supply and fixing in replacement 15 mm bore gun metal gate/stop valve (ISI Mark) with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 80 | Supply and fixing in replacement 20 mm bore gun metal gate/stop valve (ISI Mark) with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 81 | Supply and fixing in replacement 25 mm bore gun metal gate/stop valve (ISI Mark) with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 82 | Supply and fixing in replacement PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) of size 6.0 Sqmm 3 Core (Nominal Area) complete all as specified and directed. |
| 83 | Supply and fixing in replacement GI union 25 mmfor pipe connection any type as per ground for solar water heater. |
| 84 | Supply and fixing in replacement GI Elbow 25 mmfor pipe connection any type as per ground for solar water heatercomplete all as specified and directed. |
| 85 | Supply and fixing in replacement GI Tee 25 mmfor pipe connection any type as per ground for solar water heatercomplete all as specified and directed. |
| 86 | Supply and fixing in replacement CPVC Elbow 20mmfor pipe connection any type as per ground for solar water heatercomplete all as specified and directed. |
| 87 | Supply and fixing in replacement socket fitting as per ground for connection of pipe and solar plate of suitable sizecomplete all as specified and directed. |
| 88 | Supply and fixing in replacement Float ball valve 25 mm size high pressure ,polythene float an flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 89 | Supply and fixing in replacement MCB \"C\" series single pole 6 to 32 Amps, breaking capacity 10KAcomplete all as specified and directed. |
| 90 | Supply and fixing in replacement MCB \"C\" series single pole and neutral 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. |
| 91 | (Note : The Scope of Work contained in \"Sch of Credit\" amounting to Rs. 52,616.00 (refer Tender Srl Page No 28). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’ |