Tender For Provision Of Certain Minor And Revenue Works At Khanpur, Anuj Vihar And Vikram Vihar Under Age B/R-I And Age E/M Of Ge South Delhi Cantt-1- 1 M&L for Cutting holes into or through brick wall bult in cement mortar or cement lime mortar and stone walls not exceeding 150 sqcm including making good to the original surface complete all as specified and as directed. 2 M&L for Cutting chases, pining in making good to facing where required and pinting in cement to, cutting not exc 10cm girth in brick walls including making good to the original surface complete all as specified and as directed. 3 S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and as directed. 4 S&F Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw/ L-type or J-type cranked hook complete all as specified and as directed. 5 M&L for Rolled mild steel work in roof, purlins, crane gantries, framed brackets of angles or other section gusset plates, Flat Iron rails braces etc, drilled for fixing, and other coveringetc to be prepared for hanging and sliding with and including either hooks and hingesand other covering running railsand guides and hanging also fastening and fixing complete. Fe- 410 Grade E-250 quality -B, complete all as specified and as directed. 6 M&L for preparation of new or untreated steel surfaces of any description over 10 cm in width or grith, not otherwise described including applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. 7 M&L forcement Concrete type B-1 1:2:4 ( 20 mm graded crushed stone aggregate) as in roof Kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. 8 Excavating in post holes in any type of soil (or similar holes) each not exceeding 0.5 cum, getting out , returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed. 9 Supply only chain link MS galavnised fencing 50mm square mesh with 10 gauge complete all as specified and as directed. 10 Fixing only chain link fencing incl line wires any mesh size & type to any type of standards rails straining bolts etc. incl provision of binding wire complete all as specified and as directed. 11 M&L for old size brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. 12 M&L for old size brick work with sub class B old size burnt bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specifie and directed 13 M&L for renderning 15 mm thick in cement mortar 1:4 mixed including WPC on any faces of brick/concrete surfaces finished even and fairwith out using extra cement complete all as specified and as directed. 14 M&L for preparation of newly plastered surface and applying two coat of cement base paint, complete all as specified and as directed. 15 Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and as directed. 16 M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. 17 M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base offlooring complete all as specified and as directed. 18 M & L for 80 mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. 19 M & L for 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. 20 Removing excavated soils exceeding 500 m and depositing where directed at a level notexceeding 1.5 m above the starting point complete all as specified and as directed. 21 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the primess complete all as specified and as directed. 22 M&L for 25 mm thick cement concrete typeB-0, 1:2:4 (using 12.50 mm graded crushed stone aggregate) as in flooring complete all as specified and as directed. 23 M&L for Vitrified Ceramic tiles light shade 9-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, infloors etc. set and jointed in neatcement slurry and pointed inwhite or coloured cement to match over and including 15mm thick screed bed in cm 1:6 for laying floor finish complete all as specified and as directed. 24 M&L for non skid coloured ceramic tiles jointless 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.2 sqm but not exceeding 0.38 sqm,in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 for laying floor finish complete all as specified and as directed. 25 M&L for coloured glazed ceramictiles 350x250x7mm / 450 x 350 x 8mmthick in dado/ skirting ,set and jointed in neat cement slurry & pointed in coloured cement includind 10 mm thick backing coat in cement mortore 1:4 complete all as specified and as directed. 26 Taking down shutter of any description exc 1.00 sqm but not exceeding 2.00 sqm each and refixing the same opening including easing and adjustingthe same complete all as specified and as directed. 27 Taking down cement plaster on brick/concrete surface including racking out joints hacking for key scrubbing down with water etc. complete all as specified and as directed. 28 M&L for 15 mm thick cement mortar plaster on brick or concrete surfaces in cement mortar 1:6finished even and smooth surface wihtout using extra cement on internal wall of up to four stories bldgs complete all as specified and as directed. 29 M & L for preparing new plastered surfaces of wall and applying two coats of distemper oil emulsion, over a coat white or tinted over & including a coat of wall careputty complete all as specified and as directed. 30 M&L for complete removal of existing treatment, wahsing down and stopping of distempered and painted surfaces andpreparation of oldplastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty complete all as specified and as directed. 31 S&F in repairs 15 mm bore brass CP Wall mixer for mixing Hot and cold water screwed down for iron pipe complete all as specified and as directed. 32 S&F in repairs vitreous china wash hand basin, white round shape size 520x450x200 mm (excluding taps, waste, pipe chain and plug) but including porcelain stopper and a pair of MS bracket etc complete all as specified and as directed. 33 S&F in repairs chromium plated brass angle valve suitable for 15mm bore pipe, complete all as specified and as directed. 34 S&F in repairs PVC connection 450 mm long with 2 Nos brass check nuts suitable for 15mm bore of pipe with washer complete all as specified and as directed. 35 S&F in repairs soap dish chromium plated brass fixed with brass nuts and screws complete all as specified and as directed. 36 S&F in repair toilet paper holder brass chromium plated complete all as specified and as directed. 37 S&F in repairs Brass chromium plated fancy type shower rose of 125mm size with or without swivel joints, complete all as specified. 38 S&F of Vitreous China wash down water closet (Pedestal pattern), white with‘P’ or ‘S’ trap, fixing with screws of suitable size, plastic seat cover, white closed pattern with flat bottom and cover, complete all as specified, making connections to trap and to flush pipe etc. and making good to floors, complete all as specified. 39 S&F in repair 15mm bore GItubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors or concealed including taking down existing tubing, complete all as specified and as directed. 40 S&F of Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30mm, complete all as specified. 41 S&F of Solid PVC Wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed. 42 S&F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed. 43 Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and getting out in any type soil complete all as specified and as directed. 44 M&L for Cement concrete 1:4:8 type D-2, (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and as directed. 45 M&L for cement concrete 1:2:4 type B-2,(using 40 mm graded crushed stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases), complete all as specified and as directed. 46 M&L forMild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. 47 S&F Mild steel screw bolts (machine made), diameter of neck in 5 -10 mm, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long complete all as specified and as directed. 48 M&L forMild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete (Fe 410-W (Gde-E- 250) quality-A) complete all as specified and as directed. 49 M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. 50 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. 51 M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) over and including 15mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. 52 S & F of 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and as directed. 53 M & L for preparation of new steel Surfaces of any description, n.exc10cm in width or girth when unconnected with other painting or when painted in a different tint and applying 2 coat of synthetic enamel paint (ordinary tint) over a coat of red oxide primer oncomplete all as specified and as directed. 54 Removing excavated material hard/dense soil exceeding 50 m but not exceeding 250 m deposited where directed at a level not exceeding 1.5 m above the starting point for soil, complete all as specified and as directed. 55 M&L for reinforced cement concrete 1:2:4 (Nominal Mix) B-0 using 12.50mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. 56 M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete, complete all as specified and as directed. 57 M&L for mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including muld seel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. 58 All as per item no 57.00 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, complete all as specified and as directed. 59 Supplying and fixing of 20 mm outer dia CPVC pipes SDR 13.50 & PlainCPVC SDR 13.50 including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing fixed on walls/ceiling or laying in floors complete all as specified and as directed. 60 Supplying and fixing of 25 mm outer dia CPVC pipes SDR 13.50 & PlainCPVC SDR 13.50 including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing fixed on walls/ceiling or laying in floors complete all as specified and as directed. 61 S&F rotational moulded polyethylene water storage tank of 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position and making necessary holes for inlet, outlet and overflow pipes but with fittings such as tank connection and ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe of size 20mm dia etc, complete all as specified and as directed. 62 S&F 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and as directed. 63 S&F of Brass chromium plated bottle traps for wash basins with inletand outlet screwed for pipe or connections including necessary packing, union and cap, bore of trap 32mm, complete all as specifed & directed. 64 S&F of PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. 65 M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed. 66 S&F of 75mmPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. 67 S&F of 110mmPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. 68 Supply & fixing false ceiling at all heights with GRG (Glass Fibre with Reinforced Gypsum) false ceiling with semi perforated 12 mm thick micro tegular edged tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistanceof 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick(galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 tiles fully mm center to center and 40mm long dry wall wood screws complete all as specified and as directed. 69 S&F Gl frame work for seamlessceiling comprising of Glperimeter channnel 0.55 mm thick with two unequal flangesof 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including 6mm thick Nonasbestos fibre cement buildingboards fixed or laid/ inserted totimber/GI/Aluminium framework with screws complete all as specified and as directed. 70 S&F of white vitreous china flat back half stall urinal of size 580x380x350 mm with white 5 litre PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, floor trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required complete all as specified and as directed. 71 S&F Vitreous china urinal partition white of size 310x700 mm complete all as specified and as directed. 72 S&F of Vitreous China, wash hand basin, table top, coloured of suitable size as directedincluding pillar tap sensor based,brass CP waste coupling 32mm dia with long screwed shank and fly nuts, GI medium grade, 32mm dia waste pipe, complete all as specified. 73 M&L for 100mm thick cement concrte 1:4:8 type D2 , using 40mm graded stone aggregate, complete all as specified and directed. 74 S&F 15 mm angle valve/ stop valves, cast copper alloy, chromium palted, fancy type screwed down high pressure with crutch and butter fly handles, screwedwithiron pipes or for union, complete all as specified and as directed. 75 Returning, filling in, inluding spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25cm thick each in trenches, after the pipes have been laid and tested, complete all as specified and directed. 76 S&F of Grease Trap unit fabricated from 8 mm thick high-density polymer sheet, having three compartments of internal size 1.5 m (L) × 0.75 m (W) × 0.75 m (D), complete with the following:i) Removable top cover of the same material for inspection and cleaning.ii) Removable perforated sludge basket in first compartment for solid sludge removal.iii) 25 mm dia oil outlet valve for manual removal of floating oil and grease.iv)100 mm dia effluent outlet connection with all necessary pipes, fittings, and accessories up to the nearest inspection chamber.v) Internal baffle plates for separation of solids, grease, and effluent.vi) All necessary excavation, PCC foundation, levelling, placement, connection, and backfilling.Note: The rate quoted by the tenderer shall be deemed to include the cost of all materials, fittings, accessories, labour, tools, plants, and incidental works required for the complete installation of the grease trap unit as specified and directed by the Engineer-in-Charge. 77 Taking down copper/aluminium point wiring (light, fan, socket or pwer) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets etc making good disturbed surfaces of walls, floors etc. complete all as specified and as directed. 78 M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including new PVC conduit on surface medium gradeand sunk in new pressed steel terminal boxes of required sizefactory made and factory painted with stove enameled black paint with top cover modular front & back plate of approved colour/model of suitable size for housing the modular switches, sockets and fan regulators with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified for following :-Note 01:- New conduit with connected accessories will be laid if there is damage in existing conduit and the rates are inclusive of quoted rates. Note 02:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete. 79 All as per item No 78.00 here-in-before but One light /fan point controlled by one way switch 80 All as per item No 78.00 here-in-before but one 3 pin socket outlet, 5/6 Amps, independent, with cable 1.5 Sqmm complete all as specified and as directed. 81 All as per item No.78.00 here-in-before but for one socket outlet 15 Amps on independent board with cable 2.5 Sqmm complete all as specified and as directed. 82 All as per item No.78.00 here-in-before but for one socket outlet 15 Amps on independent board with cable 4.00 Sqmmcomplete all as specified and as directed. 83 S&F switch 6 Amps modular type,1M with red indication single pole one way, ISI marked complete all as specified and as direected. 84 S&F modular type 2/3 pin combined shutered type 6 A socket, complete all as specified and as directed. 85 S&F switch modular type 15/16 Amps SP one way complete all as specified and as directed. 86 S&F modular type 2/3 pin combined shuttered type 16 A socket complete all as specified and as directed. 87 S&F modular AC box with MCB 20 Amp complete all as specified and as directed. 88 S&F recessed/surface mounting 36 watt 2 x 2 flat LED panel with occupancy sensor fitting with soft/warm light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed. 89 S&F recessed/surface mounting 36 watt 1 x 4 flat LED panel with occupancy sensor fitting with soft/warm light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed. 90 S & F LED track light black finish 10 W 230 V 50 Hz warm white complete with all fittings and fixtures all as specified and as directed. 91 Supply and Fixing of Wall-Mounted Fan, made of sturdy engineering plastic, with 400 mm sweep, fitted with copper-wound motor, suitable for operation on 230 V, 50 Hz, single-phase AC supply, complete with oscillation mechanism, speed regulator/control switch, mounting brackets, and all necessary accessories for proper installation, testing, and commissioning, all as specified and directed. 92 S&Fexhaust fan, metal body, copper wound 300 mm sweep with metal louver including and connecting up with flexible cable of size 1.5 sqmm from ceiling connection to fan, complete all as specified and directed. 93 Supply & Fixing in replacement sheet metal enclousure double door for DBs where MCBs to be used Single pole and Neutral 12 way ,240 volts,double door bus bar neutral link, earth bar and din rail, complete all as specified and directed. 94 Supply & Fixing in replacement MCB SPN 63 Amps C curve240 volts, complete all as specified and directed. 95 Supply & Fixing in replacement MCB SPN 40 to 63 Amps C curve240 volts, complete all as specified and directed. 96 Supply & Fixing in replacement MCB SP 6 to 32 Amps,B curve240 volts, complete all as specified and directed. 97 M & L for sub main wiring using single core PVC FRLS grade insulated unsheathed, multisrand copper conductor cable 2 runs of 10 Sqmm for Phase and neutral and 1 run of 10 Sqmm for earth wire drawn through existing PVC/MS conduit and including replacement of unsv pressed steel terminal boxes of in wall as per suitable/existing dia with fittings like tees, bends junction/terminal boxes etc as per site requirement and complete all as specified and as directed. Notes : (a) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (b) Three runs of main cable and one run of earth cable all together shall be considered as one length.(c) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.