Tender For Misc B/R Repair Of External Services Under Age (I) (U) B/R Delhi Cantt-10 - Taking down rolling shutters complete pull/push or gear operated/ manually type including servicing, repairing all moving mounted parts / components (including locking arrangements) necessary welding easing, adjustment , replacing damaged parts such as (slates, bottom lock plate, helical spring, head gear box, hood cover, pullies, pipes) wherever required, greasing,refixing in the same location and painting with synthetic enamel paint to complete all as specified anddirected by Engineer-in-Charge.Note:- Spare parts will be measured & paid separately. 2 Supply only mild steel 1.25mm thick black sheet as in top cover for rolling shutter fixed to wall in proper size , shape & position suitable for rolling shutter including removing damaged portion and applying one shop coat of primer before fixing complete all as specified anddirected by Engineer-in-Charge. 3 Supply only MS Spring for rolling shutter, size of spring 450mm long inner dia not less than 65mm and MS wire 8mm dia complete all as specified anddirected by Engineer-in-Charge. 4 Supply only MS pipes heavy duty of 40mm dia as in shaft of rolling shutter complete all as specified anddirected by Engineer-in-Charge. 5 Supply only cast iron geared pullies of standard size and shape as per existing and suitable for operation of rolling shutters as required complete all as specified anddirected by Engineer-in-Charge. 6 Supply only head gear box of standard size and shape with key as per existing & suitable for operation of rolling shutter as approved complete all as specified anddirected by Engineer-in-Charge. 7 Dismantling old MS/steel rolling shutter of any size and position including cutting hole for taking down existing hold fast complete all as specified anddirected by Engineer-in-Charge. 8 S&F of steel rolling shutters, thickness of lath is 1.25mm with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified anddirected by Engineer-in-Charge. 9 S&F of steel rolling shutters, thickness of lath is 1.25mm with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated but gear operated type with bevel gear box and crank handle complete all as specified anddirected by Engineer-in-Charge. 10 M&L for preparation of new steel / iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified anddirected by Engineer-in-Charge. 11 S&F for safety lever locks mild steelwith 4 levers for rolling shutters complete all as specified anddirected by Engineer-in-Charge. 12 S&F for ball bearing for rolling complete all as specified anddirected by Engineer-in-Charge. 13 M&L for PCC 1:2:4 type B0 (using 12.5/10 mm graded stone aggregate )as in hold fast complete all as specified anddirected by Engineer-in-Charge. 14 Hacking out old broken glass any thickness size and quality from wooden/steel frames including punching and drillingout old glazing pin and provide new complete all as specified anddirected by Engineer-in-Charge. 15 S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane etc complete all as specified anddirected by Engineer-in-Charge. 16 Taking down door / window frame with shutter (without taking of shutter from the frame ) area not exc 1.5 sqm complete all as specified anddirected by Engineer-in-Charge. 17 Taking down door / window frame with shutter (without taking of shutter from the frame ) areaexc 1.5 but n exc 4sqm complete all as specified anddirected by Engineer-in-Charge. 18 Taking down shutters but area exc 1.00 sqm but not exc 2.00 sqm including iron mongry and fittings etc complete all as specified anddirected by Engineer-in-Charge. 19 M&L for flush shutter 30mm thickness, solid core construction, with block board core and plywood face panel, commercial type on both sides complete all as specified anddirected by Engineer-in-Charge. 20 M&L for 2nd class hard wood 35mm glazed and skelton shuttersopen rebated and prepare to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24(a) supplied and fitted to chowkats complete all as specified anddirected by Engineer-in-Charge. 21 S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified anddirected by Engineer-in-Charge. 22 S&F of factory made solid PVC panelled door shutter 30mm thick (Style)consiting of frame made out of MS tubes for top & bottom rails ,MS frame shall be covered with heat moulded wood grain printed coloured PVCC channel having PVC sheet strip of 20 mm width struck inside with solvent cement for styles andcolour PVC sheet for Toprail, panelling of plain colour PVC sheet to be fitted in the MS framewelded/sealed to the style and rail with suitable PVC sheet beading and jointed toghether with solvent cement etc fixed with frame at site complete all as specified anddirected by Engineer-in-Charge. 23 M&L for preparation of new Wooden surfaces of any description , nototherwised described over 10 cm width or girth and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified anddirected by Engineer-in-Charge. 24 S&F of 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed. 25 S&F of 150 mm long aluminium anodised handle cast typeand fixed. 26 S&F of butt hinges , medium weight , cold rolled , mild steel or stainless steel, 100 mm longfixing with screws or welded to frame as required at site complete all as specified anddirected by Engineer-in-Charge. 27 S&F of 250 mm aluminium anodised sliding door bolts with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing boltand sliding bolts of extruded section or cast alumnium alloy and fixed complete all as specified anddirected by Engineer-in-Charge. 28 S&F in repairs stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified anddirected by Engineer-in-Charge. 29 S&F of stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified anddirected by Engineer-in-Charge. 30 S&F of steel window with side hung shutters including projecting or box stype hinges with steel handle peg stay and divided into square with glazing bars dovetailed or welded, to receive glazing, or gauzing including one coat of red oxide primer including fixing of hold fast of size 25 x 5 mm flat iron etc complete all as specified anddirected by Engineer-in-Charge. 31 M&L for framed work such as grills, gratings, etc .. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work including one coat of red oxide primer & confiring to Fe.290.Gde-E-165 complete all as specified anddirected by Engineer-in-Charge. 32 Dismantlingfloor,hearth or wall tilingincluding cement mortar bedding ( includingbacking) removing from siteand rubbish off premises complete all as specified anddirected by Engineer-in-Charge. 33 M&L forNon-skid Ceramic colour tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc over and including 15 mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade / colour / matrix of the tiles complete all as specified anddirected by Engineer-in-Charge. 34 M&L for glazed ceramic coloured tiles in vertical surface such as skirting / dado etc,of size 350 x 250 x 7mm thick or 450 x 350 x7 mm thick over and including 10 mm thick bedding layer in CM 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade / colour / matrix of the tiles complete all as specified anddirected by Engineer-in-Charge. 35 M&L for vitrified ceramic light coloured tiles 10 mm thick (square/rectangular) area of each tile n.exceeding 0.36 Sqm in floors etc set and joined in neat cement slurry and pointed in white or colour cement to match colour tiles including 20 mm thick screed bed in cement mortar (1:6)complete all as specified anddirected by Engineer-in-Charge. 36 S&F of vitrifiedceramic tile 8 to10 mm thick lightshade (square / rectangular) polished, area of each tile not exceeding 0.36 sqmover 10 mm thick plaster in Cement Mortar 1:4 as in vertical surface like skirting dadoetc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified anddirected by Engineer-in-Charge. 37 Demolition of cement concrete (unreinforced) in ground floors and paving n. Exc 15 cm thickness (below or above ground level)complete all as specified anddirected by Engineer-in-Charge. 38 M&L for 75 mm thickcement concrete type D-21:4:8 (40mm graded aggregate) as in sub base complete all as specified anddirected by Engineer-in-Charge. 39 M&L for 18 -20 mm thick polished kota stone, machine cut kota stone slab flooringover 20mm cement screed bed in cement mortar(1:6), andjointed in neat cement slurry mixed with pigment to match the shade of slabcomplete all as specified anddirected by Engineer-in-Charge. 40 Demolition of brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified anddirected by Engineer-in-Charge. 41 M&L forbrick work with sub class B bricks (old size) straight or curved on plan exc 6 m mean radius, built in cement mortar (1:4)complete all as specified anddirected by Engineer-in-Charge. 42 Taking down cement plaster, any description from brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, including taking down roots of trees complete etc. complete all as specified anddirected by Engineer-in-Charge. 43 M&L for rendering 10 mm thick on brick or concrete surfaces in CM 1:6, finished even & smooth without using extra cement complete all as specified anddirected by Engineer-in-Charge. 44 M&L for preparation of newly untreated plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer with alkali resistant priming paintcomplete all as specified anddirected by Engineer-in-Charge. 45 M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra complete all as specified anddirected by Engineer-in-Charge. 46 M&L forapplying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/Litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company Depot Tined) with silicon additives @ 1.43 Ltr/10 sqm over and including primer coats of exterior primer applied @ 0.90 Ltr/10sqm over new surfaceover a coat of primer (chalk whiting ) complete all as specified anddirected by Engineer-in-Charge. 47 M&L for rendering 5 mm thick in cement mortar (1:3) on ceilling finish even and smooth w / o using extra cement complete all as specified anddirected by Engineer-in-Charge. 48 M&L for preparation of newly plastered surfaces on ceiling and applying three coats white wash complete all as specified anddirected by Engineer-in-Charge. 49 Taking down aluminium door /window shutter and partition wall of any description iron mongry and fittings complete all as specified anddirected by Engineer-in-Charge. 50 M&L for Anodised aluminium frame for doors, windows, ventilators and partion wall with one or more rebates including joining cleat for fixing etc. complete all as specified anddirected by Engineer-in-Charge. 51 M&L for anodised aluminium powder coatingdoor shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified anddirected by Engineer-in-Charge. 52 S&F of 4.8 mm thick sheet glass ordinary quality pin headed typein squaresnot exc 0.5sqm in each pane complete all as specified anddirected by Engineer-in-Charge. 53 M&L for 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, for aluminium door / partition complete all as specified anddirected by Engineer-in-Charge. 54 S&F in repairsfor door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified anddirected by Engineer-in-Charge. 55 S&F in repairsdouble action floor spring hydraulically regulated made up of mininum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty complete all as specified anddirected by Engineer-in-Charge. 56 Dismantling of cast iron/PVC pipes 75/100mm dia complete all as specified anddirected by Engineer-in-Charge. 57 S&F of PVC (SWR) pipe 110 mm dia single socketed with rubber ring joints laid in trenches or in floor including necessary excavation complete all as specified anddirected by Engineer-in-Charge. 58 S&F of PVC (SWR) pipe 110 mm dia single socketed with rubber ring joints fixed to wall complete all as specified anddirected by Engineer-in-Charge. 59 S&F of PVC (SWR) pipe 110 mm dia bends complete all as specified anddirected by Engineer-in-Charge. 60 S&F of PVC (SWR) pipe 75 mm dia single socketed with rubber ring joints laid in trenches or in floor complete all as specified anddirected by Engineer-in-Charge. 61 S&F of PVC (SWR) pipe 75mm dia single socketed with rubber ring joints fixed to wall complete all as specified anddirected by Engineer-in-Charge. 62 S&F of PVC (SWR) pipe 75 mm dia bends complete all as specified anddirected by Engineer-in-Charge. 63 Dismantling Plain or corrugated steel sheeting/AC/ Fibre reinforced, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified anddirected by Engineer-in-Charge. 64 S&Fof pre-painted galvalume aluminium sheet zinc coatin GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified anddirected by Engineer-in-Charge. 65 S&F ofpre-painted galvalume aluminium sheet zinc coatin GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified anddirected by Engineer-in-Charge. 66 M&L for preparation of existing roof surface by scraping, cleaning and making rough to receive the roof treatment complete all as specified anddirected by Engineer-in-Charge. 67 M&L for PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) finishing cement concrete surface even and smooth without using extra cement in roof padding of any position of any height complete all as specified anddirected by Engineer-in-Charge. 68 M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sq.m including cleaning base surfaces complete all as specified anddirected by Engineer-in-Charge. 69 M&L for 3mm thick APP based polymeric membrance weighing not less than 3Kg/Sqm, reinforced with polyester non wove fabric (Wt not less than 150 gms/sqm) laid on primed surface by forced application using gas torch with an overlapping 100mm on each side complete all as specified anddirected by Engineer-in-Charge.Note: No extra charges shall be paid for gas & other arrangements. 70 M&L for preparation of new surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of aluminium paint complete all as specified anddirected by Engineer-in-Charge. 71 M&L for PCC 1:2:4 type B-1 (using 20 mm graded agg) in kerbs , rounded or chamfered on edges including necessary form work complete all as specified anddirected by Engineer-in-Charge. 72 Disconnecting existing tanks of 500 litre capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified anddirected by Engineer-in-Charge. 73 Disconnecting existing tanks of 1000 litre capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified anddirected by Engineer-in-Charge. 74 Demolition of mud in roof/PCC any thickness including plastering, leeping(whether full thickness removed or only a part thereof) , and mud removing to out side of defence land etc, complete all as specified anddirected by Engineer-in-Charge.(Note: Mud stacking shall not be allowed at site.) 75 M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection or mass concrete complete all as specified anddirected by Engineer-in-Charge.