| 1 | Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender documents & all corrigendum/amendments and general condition of contracts before entry/quoting the rates.Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading ofincorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender. |
| 2 | Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole / stay, or cable trenches and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25 cm in soft loose soil complete all as specified and directed. |
| 4 | Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 5 | M&L for sand cushioning for protection of underground cable, consolidatedandcompacted with clean dry sand complete all as specified and directed. |
| 6 | S&F Unreinforced Pre-cast Concrete Cable Cover, Class HV type 2 flat of size 450x180x40mm with minimum average breaking load 350 Kg, as per IS-5820:1970, complete all as specified and directed. |
| 7 | M&L fortaking up and relaying HT UG Cable uptosize 240 sqmm x 3 core complete all as specified and directed.Note:- Necessary earth work, PCC cover, sand cushning etc will be measured and paid seperately under respective schedule items. |
| 8 | Relaying of serviceable UG cables of any cross sectional area and connections including Bricks, GI Pipes, etc of any descriptions, laid in trenches and/or fixing with walls/poles complete all as specified and directed.Note:- Earthworks, Sand Cushioning, Brick/slab, GI Pipe, etc. will be measured and paid under appropriate Items. |
| 9 | Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and directed.Note:- Earthworks, Sand Cushioning, Brick/slab, GI Pipe, etc. will be measured and paid under appropriate Items. |
| 10 | M&L for Cable End Jointing KitIndoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and directed. |
| 11 | M&L for Cable End Jointing KitIndoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 120 Sqmm complete all as specified and directed. |
| 12 | M&L for Cable End Jointing KitIndoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 240 Sqmm complete all as specified and directed. |
| 13 | M&L for Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and directed. |
| 14 | M&L for Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 120 Sqmm complete all as specified and directed. |
| 15 | M&L for Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 240 Sqmm complete all as specified and directed. |
| 16 | M&L for Cable Jointing Kit Straight Through Termination Heat Shrink-able type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and directed. |
| 17 | M&L for Cable Jointing Kit Straight Through Termination Heat Shrink-able type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size120 Sqmm complete all as specified and directed. |
| 18 | M&L for Cable Jointing Kit Straight Through Termination Heat Shrink-able type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size120 Sqmm complete all as specified and directed. |
| 19 | S&F Galvanised Iron Pipe light grade of size80 mm dia as in protection of UG Cable laid in trenches of following sizes complete all as specified and as directed.Note:- Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemed to be included in the Quoted Unit Rate. |
| 20 | S&F Galvanised Iron Pipe light grade of size100 mm dia as in protection of UG Cable laid in trenches of following sizes complete all as specified and directed.Note:- Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemed to be included in the Quoted Unit Rate. |
| 21 | M&L for boaring holes horizontally under Road without damaging the surface of road ( minimum 1.0 Mtr below the road surface with the help of GI tubing of any dia not exceeding 100 mm bore for passing of UG cable complete all as specified and directed.Note:- GI pipe laid shall be measured seperately. |
| 22 | S&F Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11 kilo volt complete all as specified and directed. |
| 23 | S&F Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 33 kilo volt complete all as specified and directed. |
| 24 | S&F Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, forHT, 25x20cm size complete all as specified and directed. |
| 25 | S&F Pre-cast Reinforced Cement Concrete (1:2:4) (20mm graded aggregate) TypeB-1 of size (0.5M X 0.05MX1.0M) Cable Route Indicator including embossing \"DANGER/11KV CABLE/MES\" on both sides andpainted Letters with approved Colour, burried in ground for a depth of 45 Cm including necessary Earth Work, complete all as specified and directed. |
| 26 | M&L for shifting/ raising up height of existing HT Bus Barbox outdoor type by carefully digging of HT cable loop and dismantling of PCC foundation of HT bus bar panel including groutting of HT panel with PCCfoundation of min size ( 0.9L x 0.45W x 0.9H mtr) from ground level alongwith scaping of old paint and rust of HT panel surface by applying two coats of synthetic enamel paint (first quality) over a red oxide/zinc chrome primerexternaly and danger marking of 11000 volt complete of size 1.0X1.5X1.0 metre including all cable jointing nuts bolts made of brass/ HS steel of sutable sizecomplete all as specified and directed.Note:- Dismantling, shifting and refixing including proper PCC foundation required as per site condition and necessary earth work shall be deemed to be uncluded inunit Rate. |
| 27 | M&L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular four Pole structure (above the Planting Depth and PCC Copings of 11.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of Red Oxide Zinc Chrome Primer, alternate Yellow & Black or approved colour shade Strips Painting (4 No. Each Strip 200 mm wide) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint,complete all as specified and directed. |
| 28 | M&L for sub class ‘B’ old size bricks, laid flat, dry in trenches for cable protection complete all as specified and directed. |
| 29 | M&L fortaking up and relaying LT UG Cable uptosize 400 sqmm x 3.5 core complete all as specified and directed.Note:- Necessary earth work , PCC cover/ bricks, sand cushning etc will be measured and paid seperately under respective schedule items. |
| 30 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectional area 16 sqmm 4 core complete all as specified and directed.Note:- Excavation and earth work will be measured and paid separately under respective items. |
| 31 | All as per item No 29.00 above butsectional area 50 Sq mm 3.5 core. |
| 32 | All as per item No 29.00 above butsectional area 95 Sqmm 3.5 core. |
| 33 | All as per item No 29.00 above butsectional area 120 Sqmm 3.5 core. |
| 34 | All as per item No 29.00 above butsectional area 150 Sqmm 3.5 core. |
| 35 | All as per item No 29.00 above but sectional area 240 Sqmm 3.5 core |
| 36 | All as per item No 29.00 above but sectional area 300 Sqmm 3.5 core |
| 37 | Supply and laying double walled corrugated (DWC) HDPE cable duct pipe medium duty of 40 mmdia conformingto IS, approved colour complete with fittings for cable protection complete all as specified and directed. |
| 38 | Supply and laying double walled corrugated (DWC) HDPE cable duct pipe medium duty of 50 mmdia conformingto IS, approved colour complete with fittings for cable protection complete all as specified and directed. |
| 39 | S&F cable jointing kit for 1.1 KV grade cable for straight through jointcomplete with Jointing material heat Shrinktype and accessories suitable for 3 ½ / 4core XLPE, armoured, Al conductor cableof size 25 to 50 sq mm,Indoor/Outdoor type complete all as specified and directed. |
| 40 | S&F cable jointing kit for 1.1 KV grade cable for straight through jointcomplete with Jointing material heat Shrinktype and accessories suitable for 3 ½core XLPE, armoured, Al conductor cableof size 70 to 150 sq mm,Indoor/Outdoor type complete all as specified and directed. |
| 41 | S&F cable jointing kit for 1.1 KV grade cable for straight through jointcomplete with Jointing material heat Shrinktype and accessories suitable for 3 ½core XLPE, armoured, Al conductor cableof size 185 to 240 sq mm,Indoor/Outdoor type complete all as specified and directed. |
| 42 | S&F cable jointing kit for 1.1 KV grade cable for straight through jointcomplete with Jointing material heat Shrinktype and accessories suitable for 3 ½core XLPE, armoured, Al conductor cableof size 300 to 400 sq mm,Indoor/Outdoor type complete all as specified and directed. |