| 1 | Sch \"A\" |
| 2 | M&L for cleaningthe RCC/ PVC water storage tankof capacity not exceeding 500 Ltr of any description and in any position drain out the water by using exit valve or high capacity dewatering system, cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69laboratory tested branded chemical of the company and scrubbing the walls of the tanks,fresh water cleaning by high speed jet pump,cleaning the floor of water tank by industrial vaccum cleaner complete all as specified and directed. |
| 3 | All as per ser item No. 1 above but for of inside the RCC/ PVC water storage tankof capacity not exceeding 1000 Ltrcomplete all as specified and directed. |
| 4 | All as per ser item No 1 above but for ofinside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumpsof capacity UG sump reservoir 50000 gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY complete all as specified and directed. |
| 5 | Supply & fixing 20mm bore ball brass valves,high pressure,with polythylene float and flynut complete,screwed for iron pipe or brass ferrule complete all as specified & directed. |
| 6 | Supply & fixing 20mm automatic water level control float valve inside type for water tank with stainless steel exterior finish, BSP thread, nylon material complete all as specified & directed. |
| 7 | S&F in repairs small GI fittings 15mm bore such as socket, tee, elbow reducer 20 x 15 reducer 20 x 15 tee of unequal size, GI union 15mm, GI union 20mm etc as required at site complete all as specified & directed. |
| 8 | Excavation in trenches n.exc 1.5 metre wide for taking out/ laying pipe line etc. and not exceeding 1.5 metre deep and getting out in soft/ loose soil complete all as specified & directed. |
| 9 | Returning, filling in including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete all as specified & directed. |
| 10 | Removal of excavated surplus spoil to a distance n.exc. 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified & directed. |
| 11 | Supply & fixing in replacement gun metal globe or gate valve 20mm bore with iron wheel head screwed both ends for iron pipes including taking down complete all as specified & directed. |
| 12 | Supply & fixing in replacement gun metal globe or gate valve 25mm bore with iron wheel head screwed both ends for iron pipes including taking down complete all as specified & directed. |
| 13 | Supply & fixing Rotational moulded polythylene water storage tanks Cap 500 litres (cylindrical vertical with closed top) triple layer hoisted and fixed in position complete all as specified & directed. |
| 14 | Supply & fixing Rotational moulded polythylene water storage tanks Cap 1000 litres (cylindrical vertical with closed top) triple layer hoisted and fixed in position complete all as specified & directed. |
| 15 | Supply & fixing chromium plated bib taps size 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified & directed. |
| 16 | M & L for MS plate /sheet plain or chequered, 2.00 mm thick cut to pieces as required and fixed to MS frame work by means of Electric arc/gas welding complete all as specified & directed. |
| 17 | Supply & fixing galvanised irontubes of size 150mm bore (medium grade)with all fittings and laid in trenches, under floor or road including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing 150mm bore with all fittings complete all as specified & directed. |
| 18 | Supply & fixing galvanised irontubes of size 100mm bore (medium grade)with all fittings and laid in trenches, under floor or road including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing 100mm bore with all fittings complete all as specified & directed. |
| 19 | Supply & fixing galvanised irontubes of size 80mm bore (medium grade)with all fittings and laid in trenches, under floor or road including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing 80mm bore with all fittings complete all as specified & directed.. |
| 20 | Supply & fixing galvanised irontubes of size 50mm bore (medium grade)with all fittings and laid in trenches, under floor or road including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing 50mm bore with all fittings complete all as specified & directed. |
| 21 | Supply & fixing galvanised irontubes of size 40mm bore (medium grade)with all fittings and laid in trenches, under floor or road including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing 40mm bore with all fittings complete all as specified & directed. |
| 22 | Supply & fixing galvanised irontubes of size 25mm bore (medium grade)with all fittings and laid in trenches, under floor or road including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing 25mm bore with all fittings complete all as specified & directed. |
| 23 | Supply & fixing galvanised irontubes of size 20mm bore (medium grade)with all fittings and laid in trenches, under floor or road including fittings such as socket, bend, elbow, union,flanges including taking out existing GI tubing 20mm bore with all fittings complete all as specified & directed.Note for item No. 16 to 22 :- Excavation & earth work shall be measured and paid for separately under appropriate item of this Schedule). |
| 24 | Repairs to leakage run lead joint in position of size 150mm CI pipes by burning out existing joints,recovering lead, cleaning internal surfaces of socket and providing new joints with using recovered lead and additional new lead, making joint leak proof complete all as specified & directed. |
| 25 | All as per item No 23above but Size of CI pipe 100mmcomplete all as specified & directed.- |
| 26 | All as per item No 23 above but Size of CI pipe 80mm complete all as specified & directed.Note for item No. 23 to 25 :- Excavation of Earth work shall be measured and paid seperately) |
| 27 | Repairs to leakage run rubber gasket joint for 150mm bore flanged pipes and fittings including necessary fittings such as bolts, nuts, washers,white lead or mineral oil complete all as specified & directed. |
| 28 | All as per item No 26 above but Size of GI/CI pipe 100mmcomplete all as specified & directed. |
| 29 | All as per item No 26 above but Size of GI/CI pipe 80mm complete all as specified & directed.Note for item No. 23 to 28:- Excavation of Earth work shall be measured and paid seperately. |
| 30 | Supply, fabricate and fixing in repairs MS framedgrills,gratings, framed guard bars,ladder,framework of Valve pit cover, water tanks etc, or similar work as ordered and fabricated from MS rolled section of any size and shape as directed and fixed at position with all fixing accessories complete all as specified & directed. |
| 31 | Supply & fixing cast iron fitting upto 150mm bore such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces, single branch, \"Y\" junction, double branch, cross collar, caps and plugsetc. suitable for spigot and socketed pipes including taking out the defective one form the trenches or groundcomplete all as specified & directed. |
| 32 | Supply and fixing in replacement cast iron sluice valve suitable for 150mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steelspindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc including taking down complete all as specified & directed. |
| 33 | Supply and fixing in replacement cast iron sluice valve suitable for 100mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steelspindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etccomplete all as specified and directed by Engineer-in-charge. |
| 34 | Supply and fixing in replacement cast iron sluice valve suitable for 80mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steelspindle spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc including taking downcomplete all as specified & directed. |
| 35 | Supply & fixing in replacement gun metal globe or gate valve 20mm bore with iron wheel head screwed both ends for iron pipes including taking down complete all as specified & directed. |
| 36 | Supply & fixing in replacement gun metal globe or gate valve 25mm bore with iron wheel head screwed both ends for iron pipes including taking down complete all as specified & directed. |
| 37 | Supply & fixing in replacement gun metal globe or gate valve 40mm bore with iron wheel head screwed both ends for iron pipes including taking down complete all as specified & directed. |
| 38 | Supply & fixing in replacement gun metal globe or gate valve 50mm bore with iron wheel head screwed both ends for iron pipes including taking down complete all as specified & directed. |
| 39 | S&F in replacement Over load relay 30 to 50 Amps 415 V complete all as specified & directed. |
| 40 | S&F in replacement Contractor having AC 1, 85 amp and AC 3, 50 amp complete all as specified & directed. |
| 41 | S&F in replacement Front mounting add on aux contact block MNX A2 complete all as specified & directed. |
| 42 | S&F in replacement Single phase preventor, 240V AC, relay range 2-5.5A with earth fault protection complete all as specified & directed. |
| 43 | S&F in replacement Star delta timer ETR complete all as specified & directed. |
| 44 | S&F in replacement MPCB 63 Amp 3 Phase complete all as specified & directed. |
| 45 | S&F in replacement multifunction meter WL 4400 series RS485 complete all as specified & directed. |
| 46 | S&F in replacement of push button assembly with harness and indicating lamp complete all as specified & directed. |
| 47 | M&L Rewinding of submersible motor of any make & capacity 25/30 HP by using existing size and gauge of PVC insulated single core copper conductor submersible winding wire including all insulated material complete all as specified & directed. Note :- Rates are including lifting of column pipe and submersible motor,transportation all allied accessories required for repair/rewinding and reassembling the submersible motor at existing sites lowering, connecting, testing,commissioning of repaired pump set with existing size column pipes all as specified and directed by Engr- In- Charge |
| 48 | Supply only calcium hypochlorite having 60% to 70% available chlorine must contain appropriate quantities of dispersants/corroson inhibitor to prevent encrustation/scaling in distribution system note contractor supplier must submit govt lab test report of calcium hypochlorite alonbgwith each delivery packed in 45 KG plastic drum complete all as specified & directed. |
| 49 | Supply and fix in replacement of 1100 volts grade heavy duty PVC insulated flat submersible cable 10 sqmm, 3 core with copper conductor complete all as specified & directed. |
| 50 | Supply and fixing in replacement 3 metre long column pipe 100mm dia made out of medium grade GI pipe with two number flanges welded at both ends having drilled hole and cut for submersible cable complete all as specified & directed. |
| 51 | Supply & replacement of name board with in built LED lights of r/o Pump houses (size 4 feet x 3 feet) with fitted required height of angle iron complete all as specified & directed. |
| 52 | M&L repairs of valve pit chambers of size 1200mmX900mmX900mm complete all as specified & directed. |
| 53 | M&L repairs of valve pit chambers of size 900mmX600mmX900mm complete all as specified & directed. Note for item No. 51 & 52 :- The rate quoted shall be deemed to include the cost of PCC, Bricks works, Plasters, angle iron, hinges, handle, MS plate cover, white wash, painting and nuts and bolts etc. |
| 54 | Supply only chlorination test kit complete all as specified & directed. |
| 55 | M&L for preparation new painted metal surfaces of any description, over 10cm in width or girth and appling two coat of synthatic enamel paint and priming with red oxide, zinc chrome of approved tint complete all as specified & directed. |
| 56 | M&L for preparation old painted metal surfaces of any description over 10cm in width or girth and applying one coat of synthatic enamel paint of approved tint complete all as specified & directed. |
| 57 | Testing potability of water by chemical analysis as per IS- 10500 such as PH value, dissolved solids, hardness as CaCO3, calcium, magnesium, chlorides, sulphates, nitrate, alkalinity, iron, turbidity NTU, mineral oil, colour hazen units, taste, odour, residual free chlorine, total coliform per 100ml (microbiological test) & E coli per 100ml (microbiological test) as well as bacteriological portability from any Govt. Laboratory or any NABL accrediatedLab complete all as specified & directed. |
| 58 | Supply and Fix in replacement for MCCB 63 Amp, 415 V, 25 KA, 4 pole with adjustable thermal magnetic release complete all as specified & directed. |
| 59 | Supply and Fix in replacement for MCCB 100 Amp, 415 V, 25 KA, 4 pole with adjustable thermal magnetic release complete all as specified & directed. |
| 60 | Supply and Fix in replacement for MCCB 125 Amp, 415 V, 36 KA, 4 pole with adjustable thermal magnetic release complete all as specified & directed. |
| 61 | Supply and Fix in replacement for MCCB 250 Amp, 415 V, 36 KA, 4 pole with adjustable thermal magnetic release complete all as specified & directed. |
| 62 | Supply and Fix for onload Changeover Switch 63 A, 4P 415 Vwith enclosure complete all as specified and as directed by engr in-charge. |
| 63 | Supply and fixing in replacement automatic star-delta starter in sheet metal enclosures, 415 volts, 3 phase, 50 Hz type ML-3 with overload relay range 14-23 Amp suitable upto 30 HP electric motor complete all as specified & directed. |
| 64 | Developement of stabilizing/desiliting of the existing borewell size 300/200 mm dia by using suitable capacity of air compressor/ special tools/ accessories and arrangement required for Job etc.after compressor devolopment ofthe borewell by using higher size submersible pump minimum 4 to 6 hrs time or upto crystel clear water discharge complete all as specified & directed.Note:- The rates shall be inclusive of hiring of air compressor/ fuel required, special tools/ accessories, transportation of the same, disposal of discharged water including labour charges for specialy trained man poower for the work of disiliting of borewell. |
| 65 | M&L Cleaning,painting of Overhead tank out and in side,Painting to raising/deleivery/wash out/over flow CI/GI pipe line 150 mm dia Over Head reservoir (RCC) as per existing colour (Apex) code including preparation of old surface of painting with one coat of synthetic enamel paint from ground level to bottom of the dome of the tank complete removing all scale & dirt from bottom & walls and from mouthof circulation pipes of overhead tank of capacity 50,000 gallons at staging height exceeding 15 metre and not exceeding 21.5 metre and disinfecting chemical the same using disinfecting chemical (chlorine)complete all as specified & directed.Note :- The rate quoted shall be deemed to include the cost of neccessary scaffolding,supports,all type of cleaning material etc.Appx paint for RCC tank & structure and inlet & outlet pipe syenthic enamel paint. |
| 66 | Supply, Installing,Testing and Commissioning of Ultrasonic Level Transmitter at overhead tank for measurement of level with following specification:-Range : 0-8 metersAccuracy : 0.2 % minimumSupply Voltage : 10 - 30V DCOutput : 4-20 mA , 0-10V DCOperating Temprature : -20 to 70°CUltrasonic Frequency : 75 kHzResponse Time : Minimum 100 msNote: -1). The Ultrasonic Sensor need to be covered in a polycarbonate box of size 130X130X75 mm before installation on OHT.2). The Programming of Ultrasonic Sensor, e.g. Changes in range of sensor, changes in operational features etc. shall be carried out by authorized system integrator of the provided makes. The programmer shall submit a letter from the OEM as proof of his being an authorized system integrator of the OEM. The programmer shall also submit a signed report on original letterhead of the OEM that testing & commissioning has been carried out by him. |
| 67 | Supply, Installation, Testing & Commissioning of Outdoor type having Canopy and Double Door for weather protection, PLC ( Programmable Logic Controller) based Automation, Protection Panel suitable for control and monitoring of 01 Nos. Ultrasonic Sensor. The panel should be of minimum size 600(H) X 600(W) X 250(D) mm fabricated from 3.15 mm CRCA Sheet.The Panel should comprise the following functions & items:-(a) Water Level Sensing & Display(ii) 01 No. PLC with follwing specifications:- (a). 1 Nos. Ethernet communication port.(b). Suitable No. of digital / analog input and outputs.(c). Programming Software based on IEC to facilitate building of custom build function blocks.(d). Industrial Grade Processor, Web Server, SMTP E-mail service.(e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module.(iii) 01 no. HMI - 7\" Graphical Touch screen display (a). Should have 01 No. RS 485 and 01 No. USB programming port.(b). Should have USB downloading port.(c). Support external data storage on a USB memory stick for storing production data and backing up applications.(iv) 01 No. SMPS of 1.5A rating as suitable according to panel design. (vii) MCB rating 6-10A. (viii) Indicator lamp :- As per requirementNote: - The Programming, Testing, Commissioning & Integration of PLC Panel shall be carried out by authorized system integrator of the provided makes. The programmer shall submit a letter from the OEM as proof of his being an authorized system integrator of the OEM. The programmer shall also submit a signed report on original letterhead of the OEM that Programming, Testing, Commissioning & Integration has been carried out by him. |
| 68 | Supply, Installation, Testing and Commissioning of 2 Core 1.5 sq. mm PVC insulated copper armoured cable complete all as specified & directed. |
| 69 | Supply, Installation, Testing and Commissioning of 4 Core 1 Sqmm copper armoured conductor Shielded cable for Communication complete all as specified & directed. |
| 70 | M & L for retreatement of earthing by removing old earth pit and refilling Charcol & Salt cristals of 50 Kg Each including taking out old expired chemical/Charcol/Salt and refilling of soil, watering & well ramming and constrction of new earth Chamber with fixing of funnel complete with colour code such as green for body earthing/blue etc complete all as specified & directed. |
| 71 | Supply, Installation, Testing & Commissioning of water level indicator of Outdoor type having Canopy and Double Door for weather protection, PLC ( Programmable Logic Controller) based Automation, Protection Panel suitable for control and monitoring of 01 Nos. Ultrasonic Sensor. The panel should be of minimum size 600(H) X 600(W) X 250(D) mm fabricated from 3.15 mm CRCA Sheet.The Panel should comprise the following functions & items:-(a) Water Level Sensing & Display(ii) 01 No. PLC with follwing specifications:-.(a) 1 Nos. Ethernet communication port.(b). Suitable No. of digital / analog input and outputs.(c). Programming Software based on IEC to facilitate building of custom build function blocks.(d). Industrial Grade Processor, Web Server, SMTP E-mail service.(e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module.(iii) 01 no. HMI - 7\" Graphical Touch screen display (a). Should have 01 No. RS 485 and 01 No. USB programming port.(b). Should have USB downloading port.(c). Support external data storage on a USB memory stick for storing production data and backing up applications.(iv) 01 No. SMPS of 1.5A rating as suitable according to panel design.(vii) MCB rating 6-10A. (viii) Indicator lamp :- As per requirement .Note: - The Programming, Testing, Commissioning & Integration of PLC Panel shall be carried out by authorized system integrator of the provided makes. The programmer shall submit a letter from the OEM as proof of his being an authorized system integrator of the OEM. The programmer shall also submit a signed report on original letterhead of the OEM that Programming, Testing, Commissioning & Integration has been carried out by him. |
| 72 | S&Fin replacement of Off load Changeover Switch 100 A, 4P 415 V with enclosure complete all as specified and as directed. |
| 73 | S&Fin replacement of ONload Changeover Switch 100 A, 4P 415 V with enclosure complete all as specified and as directed. |
| 74 | M&L for Dismantling the water mains from the delivery lines, lifting up GI Column pipes 100/80 mm,pumping sets including submersible cable (Appx depth of well is 400 Feet) disconnecting pumping sets of capacity 20 to 35HP from cable and column pipe for carried out repair maint work andafter repairLoweringof submersible pump Sets, submersible cable, column pipes, reonnecting main delivery mains as existing and testing for satisfactory running and continuous flow of water etc complete all as directed by Engineer-in-charge at bore wells at various location in Dhora, Phillaur and CG camp mil camp. Note :-1. Repair to Motor & Pumping sets shall be measured and paid seperately. Column pipes as required for replacement shall be measured under relevant item of schedule 2. Rate quoted by the contractor shall deemed to beinclude,transportation to workshop and back at site including minor consumable/repair items like nut bolts , rubber packing 3 mm etc and taking out &loweringof submersibnle motor is included inquoted rates. |
| 75 | M&L for submersible pump repair of any make & capacity upto25/30 HP including replacementof spares parts and refixing , testing after repair complete all as specified and directed.Note:- The rates of new spares shall be included in the quoted rates. |
| 76 | M & L in replacement of Earthing complete for LT Panels/ Feeder Pillars with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres belownormalgroundlevel,connected with and including GI strip 32mm x 6mm andincluding GI pipe 50mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around includingtop and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified and directed.Note : If result is not satisfactory then contractor will do the on other location without any extra cost. |
| 77 | Supply and fixing in repair/replacement ofself priming centrifugaltype dosing pump automatic sensor basedincluding LCD screen on/off discharge capacity of 10 litre /hour withIP-65 protection antiacid plastic casing, control panel protection weather proof and resisting UV rays, standrad power supply 230V AC 50 HZ single phase with sensor, complete with agitators all as specified anddirected. |
| 78 | S & Fin replacement ofFRP container of capacity 100 ltr with PVC fittings for chlorine mixing as pump house complete all as specified and directed. |
| 79 | S & Fin replacement ofFRP containerrectangular shape of capacity 500 ltr with PVC fittings for chlorine/chemicalmixing complete all as specified and directed. |
| 80 | Supply onlyresidual chlorine and ph test kit upto 5 PPM with 500 ml bottle of Todaline reagent solution complete all as specified and directed. |
| 81 | Supply and fixing in replacement cast iron non returnvalve with GM sheet and flap of size 150 mm boreflanged ISI marked including bolts nuts, washer and rubber gasket etc including removing the existing one complete all as specified and directed . |
| 82 | Supply and fixing in replacement 3 metre long column pipe 80mm dia made out of medium grade GI pipe with two number flanges welded at both ends having drilled hole and cut for submersible cable complete all as specified and directed. |
| 83 | M & L to Repairs ofleakage any type through rubber gasket joints or flanged jointsat vertical fitted pipes with over head reservoirs located at pump houses at Doraha,Phillaur and CG area mil camp area size upto 150mm CI or DI including necessary jointing or welding work complete all as specified as directed.Note:- (i) NecessaryT&P and safety equipment and transportation for civil market if any , shall be provided by contractor without any extra cost. Any type of earth work and cement work (PCC)shall be included in quoted rates. (ii) Demolistion of base of tank or any other portion shall me made as per original by the contractor without any extra cost. rates of consumable items like nut bolt wahser rubber sheets are included in qauoted rates.(iii) Any portion of pipe line or fitting spare shall measured separately and paid under relevant item of this scheudle. |
| 84 | Supply and fixing gland packing rope style 310/350 for sluice valve size 80/100/150 mm complete all as specified and directed. |
| 85 | Supply and fixing nylon rope of size 20mm / 25mm dia multi stranded super flexible type complete all as specified and directed. |
| 86 | Supply only Copper sulphate of superior quality complete all as specified and directed. |
| 87 | Supply only of calcium based high strength chlorinator for water disinfectant as granular in factory sealed HDPE container (45 to 50 kg each) having chlorine concentration level not less than 65% complete all as specified and directed. |
| 88 | Supply and fixing PVC insulated copper cable with cross sectional area6 sqmm, 3 core complete all as specified and directed. |
| 89 | S & F PVC insulated copper cable with cross sectional area2.5 sqmm, 3 core complete all as specified and directed. |
| 90 | M & L for MS plate /sheet plain or chequered Fe- 290(Gde E-165), 3.00 mm thick cut to pieces as required and fixed to MS frame work by means of Electric arc/gas welding complete all as specified and directed. |
| 91 | S&F in repair/replacement of soft starter suitable for submersible pump upto 30 HP, 42Amp, 415Volt ,3 phase, Model No.- AST22 Schneider (415 Volt) with IP-20 protection enclosure complete all as specified and directed. |
| 92 | M&L for taking out of monobloc pumpset of 5.5 HP thereafter opening the motor at workshop,cutting removing old burnt winding coils ,cleaning filling the starter slots necessary mechanical works for shaft/bearing housing/mechnaical seal/volute/ volute base, greasing/oiling all moving parts , rewinding with suitable gauge of super enamelledcopper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing/replacement ofpumpincluding replacement of spares , cable gland, protection tube, cable seal, terminal board, cable bracket, brearing cover, double mechanical seal,tie for stand,support bracket, guide shoe, moisture sensor, potting cup, Gland iron box,ball bearings, thermal over load protector, hose nipple, shaft bleaching, suitable mainsconnections from coil to terminal box,preparing and inserting coil running/starting windinginterconnecting, fixing,soldering, jointing, heating, drying up coils, connect to main supply andtesting at site and satisfactorily running all as specified and directed .Note :- (a) Lifting/taking out ofthe moter & rrefixingafter reapir shall be arranged by the contractor without any extra cost.(b) Transportaion form site to workshop and back to site shall be included in quoted rates. |
| 93 | M&L for carrying out camera inspection of borewell upto 600 feetusing high-resolution borehole inspection camera to assess and record the internal condition of the bore casing, joints, screen, and overall structural integrity; identify issues such as encrustation, corrosion, blockage, or collapse if any; and accurately determine the static water level. The work includes mobilization and demobilization of camera equipment, skilled technician deployment, capturing of continuous video footage, depth marking, and still images as required, complete all as specified and directed by engineer-in-charge. Notes:- (i) Detail report on inspection in video or images shall be submitted to department in duplicate without any extra cost.(ii) Rate of T&P shall be included in quoted rates. |