| 1 | SCHEDULE \"A\" PART -IA DESIGN AND SUPPLY OF STPS (TO BE QUOTED BY THE TENDERER) |
| 2 | Design, Engineering, Supply, Installation and Commissioning of 100% FRP based modular and package type sewage treatment plant, specially designed for underground applications with tertiary treatment as per the details given as under:-(a) The STPs should be capable to treat waste water by using the appropriate design to achieve the treated water parameters as per CPHEEO/NGT standards and as per details given herein.(b) The main treatment plant should be completely underground with certain outdoor parts like Exhaust vents, Blowers, Air Pipes and Manholes, also the Stilling Chambers, Bar Screen Chambers, Oil and Grease Traps (Wherever and whichever feasible with flexibility to keep some of it underground) all such components are required to be available to approach from ground level. |
| 3 | (c) The STPs shall have tertiary capability based on MBBR technology made of Isopthelic Unsaturated Polyester Rasin and certified as Green Product from both CII and IGBC (Indian Green Building Council). The system consist of all Components/ Chambers such as Bar Screen, Solid Separation zone, Sludge Collection and Removal Zone etc in a modular and series concept and sourced from established reputated OEMs of the underground package type STP plant manufacturer (Maintainance services should reach in 4 hours of time period and to be available everyday 24 x 7) as per their design and drawings. Modular composite FRP containerised treatment plants in series and parallel combination are required in accordance with total plant capacity. (d) An outdoor, semi underground collection sump (Minimum 30 KL capacity for 0.3 MLD and 50 KL for 0.5 MLD STP plant) in accordance with the invert level Manhole of suitable capacity to be constructed in RCC just before the under ground package type treatment plant to cater for peak flow in terms of guidelines of CPHEEO manual (The collection sump is to be measured and paid separately under this tender). The liftwell pumps of suitable design and totally automatic to be installed in the collection sump to operate automatically in accordance with water level sensors to handle the average flow rate as well as peak flow of the influent. |
| 4 | (e) Treated water will be reused for arboriculture and for flushing purpose, however in rainy season the provision should be made dispose off the excess water in sewage line of municipal coorporation. The scheme to include tertiary treatment system like, Chemical Dozing, Multigrade Pressure Filters and Activated Carbon Filters in 100% FRP construction to achieve the desired parameters. An outdoor semi-underground, covered sump of RCC construction to collect the clear treated water is included in the scope of work which will be one 75 KL sump for 0.5 MLD Plant and one 50KL for 0.3 MLD Plant in intermediate and final stage configuration and will be part of this schedule only. The filter feed to tank / sump of RCC construction. Submersible pumps of appropriate capacity and design to be provided in both the treated water sumps, for pumping the treated water to arboriculture areas, for two-three hours in each shifts (Once in the morning and once in evening). Necessary electric works, controls, switch gears and cables etc to be catered for.(f) The scope of work includes complete design (As per the availability of site which is 25 x 20 mtrs for 0.3 MLD and 55 x 15 mtrs for 0.5 MLD STP plants including working space), drawings, excavation, removal of surplus soil out of the Ministry of Defence Land not than 1.5 Kms distance, backfilling, compacting, manholes, exhausts, treatment, reactor technology and all required Civil, Mechanical and Electrical Works Components, Disinfection System, Pipes, Cables, Controls, Monitors, Switchgears, Excavation, Manhole Chambers Foundations, Motors, Blowers, MCCBs, Sensors, Starters, Automation Components complete in all respect and all as required to cater to clean setup and an efficient system to treat the waste water and achieve the requisite parameters and re-use as enumerated here and elsewhere. Any minor items, components, sub-systems not specificaly mentioned but essentially required is considered included in the quoted rates and nothing extra shall be payable to contractor on this account. |
| 5 | (g) The STP shall be designed to treat the influent sewage water and achieve the outlet water parametres as per following details and in accordance with NGT latest norms:- S No Parameter InletOutletUnit1 pH 6.06.5-8.52 BOD250<10mg/l3 COD425<50mg/l4 Oil & grease 15.0 <10mg/l5 Nitrate Nitrogen (Total)Upto 50 <10 mg/l6 TSS Upto 200 <20 mg/l7 Faecal Coliform per 100mlNil(h) The system shall have SCADA based capabilities to acquire data and to automate and monitor the opcration of the plant. (j) Online continuous effluent parameter monitoring system to measure and display the BOD, PH, COD, TSS and residual chlorine employed in the system along with data logging capability of upto 10 days data should be shown at operator room on computer screen at an interval of upto one hour. Flow meter of appropriate type and size with digital display and data logging duly connected to central control panel shall be installed in clear water pipe line to measure the outflow.(k) The entire design, scheme, schematic including OEMs drawings and design shall be got approved from CWE office before procurement and commencement of the treatment plant. Any changes, modification, clarification sought by CWE office in fulfillment of the contract conditions shall be met by the contractor without delay and without any financial liability. A period of sixty days shall be accounted for final approval of the design of the system design drgs and components.(l) Contractor should provide testing of treated water every month by NABL lab.(m) Capacity of STP plant to be installed and commissioned is as under:- |
| 6 | (i) 500 KLD (Site availability is 55x15 mtrs including working space) as mentioned above in items 1.00 to 1.04 |
| 7 | (ii) 300KLD (Site availability is 25x20 mtrs including working space) as mentioned above in items 1.00 to 1.04 |
| 8 | SCHEDULE \"A\" PART -IB BUILDINGS (TO BE QUOTED BY THE TENDERER) |
| 9 | Construction of LAB CUM CHEMICAL STORE, OPERATOR ROOM &MOTOR CONTROL CENTER BLDG with RCC Framed Structure with permanent specifications all as shown on drawings and as specified and directed. (For 500KLD - 1 No, 300KLD - 1 No) |
| 10 | Construction of AIR BLOWER ROOM with RCC Framed Structure with permanent specifications all as shown on drawings and as specified and directed. (For 500KLD - 1 No, 300KLD - 1 No) |
| 11 | SCHEDULE \"A\" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK)Total of Sch-\"A\" Part-II B/F |
| 12 | SCHEDULE \"A\" PART-III (INTERNAL ELECTRIFICATION)Total of Sch-\"A\" Part-III B/F |
| 13 | SCHEDULE \"A\" PART-IV (INTERNAL WATER SUPPLY) Total of Sch-\"A\" Part-IV B/F |
| 14 | SCHEDULE \"A\" PART-V (EXTERNAL ELECTRIFICATION)Total of Sch-\"A\" Part-V B/F |
| 15 | SCHEDULE \"A\" PART-VI (TREATEDWATER SUPPLY) Total of Sch-\"A\" Part-VI B/F |
| 16 | SCHEDULE \"A\" PART-VII ( MANHOLES AND DRAINS )Total of Sch-\"A\" Part-VII B/F |
| 17 | SCHEDULE \"A\" PART- VIII (ROADS & PATH)Total of Sch-\"A\" Part-VIII B/F |
| 18 | SCHEDULE \"A\" PART- IX (AREA DRAINAGE)Total of Sch-\"A\" Part-IX B/F |
| 19 | SCHEDULE \"A\" PART-X ( COMPOUND WALLS/GATES)Total of Sch-\"A\" Part-X B/F |
| 20 | SCHEDULE \"A\" PART -XI (MISCELLANEOUS ITEMS) |
| 21 | SITE CLEARANCE & EARTHWORK |
| 22 | Removing excavated material (any type) and depositing it outside Ministry of Defence Land.Note (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account.(ii) This item shall be considered as per the requirement at site.(iii) All excavation earthwork covered under Sch\"A\" Part III to Part XI shall be measured and paid under this item. (S/C -234, Road -162, AD-55, EWS-33.6, TWS 500KLD-19, TWS 300KLD-15,EES - 41.3, EES 300 KLD- 8, EES 300 KLD- 12, compound wall - 28.48, MH & Drains sch - 1068.65, MH & Drains Est - 1090.92+82.05) |
| 23 | INTERNAL ELECTRIFICATION |
| 24 | M&L for Earthing with 600x600x6.0mm galvanized steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 M deep below normal ground level) with top is of the plate at depth of not less than 1.5M below ground level, connected to and including galvanized earth wire 4mm by means of bolts, nuts and check nuts and washers of galvanized steel with and including 20mm dia GI medium grade pipe for protection of GI strip to the extent of 7.5m as earthing lead including charcoal, dust and salt packed all around the earth plate in the earth pit all as per electrical plate number 3 of SSR part 1 (2009) including PCC foundation/ chamber in mix 1:2:4 type B1 with MS angle iron frame, CI cover with provision of locking arrangements and 20mm dia medium grade GI pipe from top is of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earth work in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site. complete all as specified and directed.(Note: earth protection pipe and earthing strip upto and including 7.5m length is deemed included in unit rate quoted by the contractor) |
| 25 | INTERNAL WATER SUPPLY |
| 26 | S&F health faucet with 8 mmdia ,1.2 m long flexible tube & wall hook with N.R.Vconfirming to CAT No.ALD 577 of \" Jaquar\" or of techno commericial equivalent of any other brand in the list of makes |
| 27 | DG SET |
| 28 | Supply, Installation, Testing and Commissioning of silent Diesel Engine driven generating set of capacity not less than 82.5 KVA Power Output Delivering 415 volts,50 Hz frequency operating at 0.8 p.f Lagging 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 part-2 1992 complete with foundation (as per OEM design), having in build AMF control panel with necessary meter and sound proof canopy as per latest CPCB IV Norms complete, all as specified and as directed by Engineer-in-Charge: -Make : KOEL/Powerica/Greaves cotton/Mahindra/Sudhir/Jackson/Cater PillarThe DG set Shall also Having Following Accessories:- |
| 29 | (a) Diesel Engine shall be compact vertical 3 or 4cylinder in-line, four stroke, water cooled, conforming to ISO-3046/BS-5514 and equivalent BS as amended up to date, developing suitable BHP at 1500 RPM, inclusive of the following accessories :-(i) Radiator and Radiator fan (ii) Spyder coupling guard (iii) Fly wheel (iv) Fly wheel housing complete with starter gear ring and coupling as per manufacturer design (v) Air cleaner dry type (vi) Fuel and lubricant oil filter (vii) By-pass filter (viii) Coolant inhibitor (ix) Fuel pump DRT type/in line mono block fuel injecting pump (x) Water pump (x) Lub oil pump and inclusive of first filling of lubricant oil and coolant (xi) Electric starter as manufacturer\"s design (xii) Battery charging generator (DC alternator) (xiv) Residential silencer (xiii) Lubricant oil cooler(xiv) Flexible pipe of silencer (xv) DC Volt meter (xvi) Water temperatures gauge lub oil pressure gauge. (xix) Speedo meter and Engine running hours meter |
| 30 | (xvii) Display for fault (xviii) Suitable size of turbo charger. (xix) Mehanical Governor (xx) Maintenance free batteries fully charged, as per manufacturer design.(xxi) Engine shall be TCAC(b) Alternator of 82.5 KVA shall be designed for an output at 0.8 PF @ 1500 RPM, 415 Volts, 50 Hz, 3 phase system, brushless type screen protected revolving filled, self excited, self regulated and shall be capable for handle at least 25% unbalanced loads across phases.The alternator shall have digital AVR.Notes :-(i). Voltage regulation from No load to full load in 2 Phase sensing +/- 1%.(ii). Alternator shall be flex disc closed coupled.(iii) Voltage regulator shall be solid state.(iv). Insulation shall be close H.(v). The Generator shall be having suitable capacity for one 100% one step load acceptance. |
| 31 | (c)AMF Panel shall be inbuilt of the above 82.5 KVA DG setcubical type front openable, fabricated from CRCA sheet 2mm thick complete as per manufacturer specification of Diesel Engine suitable for DG Set of capacity 82.5 KVA withcontroller.(d) Control Panel(i). Shall be RAL-9003, power coated(ii). Made out of CRCA sheet 1.6/20.mm thick.(iii). MCCBof suitble rating with SC protection.(iv) Controller which display V, I, KW, PF, KWH.(v) Indicator for load ON and set runing.(vi) CT\"s of suitable rating.(vii) Copper cables of suitble ratings for I/C and O/G termination.(viii) Control fuse duly wired and ferulled.(e) Acoustic Enclosure- Engine alternator assembly mounted on AVM with silencers and SS exhaust bellow suitable optimised to meet latest sound and emission norms as per latest CPCB IV norms. |
| 32 | Metering & Protection System :(i) Contractor ML of suitable capacity (ii) Copper bus bar of suitable capacity as per manufacturers recommendation (iii) Sensitivity relay set with suitable CTs (iv) Electronic latch circuit with tripping indication(v) Instantaneous tripping device for complete panel over current 0.5 Amp (vi) Reset facilities for complete protection of AMF Panel (vii) 3 Phase digital AVR Relay unit complete (vii) Self sequential starting relay unit 12 volts DC complete with alarm contactor (viii) Electronic timer for 220 volts for main contactor with 1 No NC auxiliary contacts (ix) Electronic timer for 220 volts but for fuel cut operation with 1 No NC auxiliary contacts (x) Battery charging unit 12 volts 10Amp complete with digital voltmeter & Amp metre (xi) Digital Multifunction meter measuring V,I,F,p.f,Energy.(xii) MCCB 100 Amps 4 pole 25 KA breaking capacity with adjustable over and adjustable short circuit - 2 Nos (xiii) Base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti-vibration pads to ensure minimum vibration as per manufacturer recommendation |
| 33 | Notes :(i) The DG set duly assembled shall be procured by the contractor directly from OEM of Engine only.(ii) The drawings and specifications of the DG set and its components shall be got approved by the contractor from the GE before procurement.(iii)Blank.(iv)The DG set after installation shall be tested for 12 hrs by the rep nominated by Accepting officer and records of the testing shall be signed by Testing officer, E-in-Charge , GE and contractor.(v) All the arrangements, necessary FOL and testing equipments etc, for testing as per note (iii) & (iv) above shall be provided by the contractor and cost of the same shall be deemed to be included in the contractor\"s quoted rates.(vi) The DG set shall be installed all as per manufacturer\"s instructions manual subject to final approval of GE. (vii) Cost for provision of PCC foundation, platform, 1:2:4type B-2 foundation of suitable size other civil works, excavation and earth work, sand cushioning, grouting bolts etc as per manufacturer\"s instructions and as directed by Engr-in-Charge shall also be deemed to be included in the quoted rate of this item. |
| 34 | Supply, Installation, Testing and Commissioning of silent Diesel Engine driven generating set of capacity not less than 62.5 KVA Power Output Delivering 415 volts,50 Hz frequency operating at 0.8 p.f Lagging 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 part-2 1992 complete with foundation (as per OEM design), having in build AMF control panel with necessary meter and sound proof canopyas per latest CPCB IV norms complete, all as specified and as directed by Engineer-in-Charge: -Make : KOEL/Powerica/Greaves cotton/Mahindra/Sudhir/Jackson/Cater PillarThe DG set shall also Having Following Accessories. |
| 35 | (a) Diesel Engine shall be compact vertical four cylinder in-line, four stroke, water cooled, conforming to IS-3046/BS-5514 and equivalent BS as amended up to date, developing suitable BHP at 1500 RPM, inclusive of the following accessories :-(i) Radiator and Radiator fan (ii) Spyder coupling guard (iii) Fly wheel (iv) Fly wheel housing complete with starter gear ring and coupling as per manufacturer design (v) Air cleaner dry type (vi) Fuel and lubricant oil filter (vi) By-pass filter (vii) Coolant inhibitor (viii) Fuel pump DRT type/in line mono block fuel injecting pump (ix) Water pump (x) Lub oil pump and inclusive of first filling of lubricant oil and coolant (xi) Electric starter as manufacturer\"s design(xii) Battery charging generator (DC alternator) (xiii) Residential silencer (xiv) Lubricant oil cooler (xv) Flexible pipe of silencer (xvi) DC Volt meter (xvii) Water temperatures gauge lub oil pressure gauge. (xix) Speedo meter and Engine running hours meter (xviii) Display for fault (xix) Suitable size of turbo charger.(xx) Mechancial governor.(xxi) Maintenace of free batteries fully charged as per manufacturer design.(xxii) Engine shall be TCAC. |
| 36 | (xix) Suitable size of turbo charger. (xx) Mechnical Governor (xxi) Maintenance free batteries fully charged, as per manufacturer design.(b) Alternator of 62.5 KVA shall be designed for an output at 0.8 PF @ 1500 RPM, 415 Volts, 50 Hz, 3 phase system, brushless type screen protected revolving filled, self excited, self regulated and shall be capable for handle at least 25% unbalanced loads across phases.The alternator shall have digital AVR.Notes :-(i). Voltage regulation from No load to full load in 2 Phase sensing +/- 1%.(ii). Alternator shall be flex disc closed coupled.(iii) Voltage regulator shall be solid state.(iv). Insulation shall be close H.(v). The Generator shall be having suitable capacity for one 100% one step load acceptance.(c)AMF Panel shall be inbuilt of the above 62.5 KVA DG setcubical type front openable, fabricated from CRCA sheet 2mm thick complete as per manufacturer specification of Diesel Engine suitable for DG Set of capacity 62.5 KVAwith suitable controller (d) Control Panel(i) Shall be RAL-9003, power coated(ii) Made out of CRCA sheet 2.0mm thick.(iii) MCCBof suitble rating with SC protection.(iv) Controller which display V, I, KW, PF, KWH.(v) Indicator for load ON and set runing.(vi) CT\"s of suitable rating.(vii) Copper cables of suitble ratings for I/C and O/G termination.(viii) Control fuse duly wired and ferulled.(e) Acoustic Enclosure- Engine alternator assembly mounted on AVM with silencers and SS exhust bellow suitable optimised to meet latest sound and emission norms as per latest CPCB IV norms. |
| 37 | Metering & Protection System :(i) Contractor ML of suitable capacity (ii) Copper bus bar of suitable capacity as per manufacturers recommendation (iii) Sensitivity relay set with suitable CTs (iv) Electronic latch circuit with tripping indication (v) Instantaneous tripping device for complete panel over current 0.5 Amp (vi) Reset facilities for complete protection of AMF Panel (vii) 3 Phase digital AVR Relay unit complete (viii) Self sequential starting relay unit 12 volts DC complete with alarm contactor (ix) Electronic timer for 220 volts for main contactor with 1 No NC auxiliary contacts (x) Electronic timer for 220 volts but for fuel cut operation with 1 No NC auxiliary contacts (xi) Battery charging unit 12 volts 10Amp complete with digital voltmeter & Amp metre (xii) Digital Multifunction meter measuring V,I,F,p.f,Energy.(xiii) MCCB 100 Amps 4 pole 25 KA breaking capacity with adjustable over and adjustable short circuit - 2 Nos (xiv) Base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti-vibration pads to ensure minimum vibration as per manufacturer recommendation |
| 38 | Notes :-(i) The DG set duly assembled shall be procured by the contractor directly from OEM of Engine only.(ii) The drawings and specifications of the DG set and its components shall be got approved by the contractor from the GE before procurement.(iii)Blank.(iv)The DG set after installation shall be tested for 12 hrs by the rep nominated by Accepting officer and records of the testing shall be signed by Testing officer, E-in-Charge , GE and contractor.(v) All the arrangements, necessary FOL and testing equipments etc, for testing as per note (iii) & (iv) above shall be provided by the contractor and cost of the same shall be deemed to be included in the contractor\"s quoted rates.(vi) The DG set shall be installed all as per manufacturer\"s instructions manual subject to final approval of GE. (vii) Cost for provision of PCC foundation, platform, 1:2:4type B-2 foundation of suitable size other civil works, excavation and earth work, sand cushioning, grouting bolts etc as per manufacturer\"s instructions and as directed by Engr-in-Charge shall also be deemed to be included in the quoted rate of this item. |
| 39 | Supply and laying DWC (Double wall corrugated) HDPE pipes of size 80 mm laid in trenches complete, all as specified and directed by Engineer-in-Charge.Make: Astral/ Dutron/ Prince/ Finolex/ Supreme/ Birla Aerocon |
| 40 | Supply and laying DWC (Double wall corrugated) HDPE pipes of size 50 mm laid in trenches complete, all as specified and directed by Engineer-in-Charge.Make: Astral/ Dutron/ Prince/ Finolex/ Supreme/ Birla Aerocon |
| 41 | M&L Earthing with 600x600x6.0mm galvanized steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 M deep below normal ground level) with top is of the plate at depth of not less than 1.5M below ground level, connected to and including galvanized earth strip 32 x 6 mm by means of bolts, nuts and check nuts and washers of galvanized steel with and including 20mm dia GI medium grade pipe for protection of GI strip to the extent of 7.5m as earthing lead including charcoal, dust and salt packed all around the earth plate in the earth pit all as per electrical plate number 5 of SSR part 1 (2009) including PCC foundation/ chamber in mix 1:2:4 type B1 with MS angle iron frame, CI cover with provision of locking arrangements and 20mm dia medium grade GI pipe from top is of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earth work in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site. complete all as specified and directed (Note: earth protection pipe and earthing strip upto and including 7.5m length is deemed included in unit rate quoted by the contractor) Location : 02 for DG set body and 02 for Neutral. (DG Set - 4+4, Ext Electrification - 7, Treated Water Supply - 2+2) |
| 42 | EXTERNAL ELECTRIFICATION |
| 43 | S&F in replacement of Cable route indicator made of CI 100mm dia welded and fitted with MS angle Iron 40 x 40x 6 mm,45 Cm long.The angle shall be grouted in PCC block 1:3:6 type C-1 (20 mmGraded aggregate) of size 150 x 150 x 150mm.The CI round shall be embossed with the work “MES HT Cables” complete all as specified and as directed.The cable path indicator shall be painded by Brown Colour. |
| 44 | Taking Down Existing LT UG armoured Cable by Manual Excavation without make and physical damage to Cable while excavation including taking Out LT cable covers and HDPE Protection Pipe for Rerouting The old cable all as directed by the Engineer-in-Charge for the following size of Cables.Note :The rate for Excavation, Extra LT UG Cables, Extra Cable covers and Extra HDPE pipes will paid and measured Seperately if required while old cable laying in Rerouting including all as specified and directed by the Engineer-in-Charge. |
| 45 | 16/25/35Sqmm of 4/3.5 Core LT UG Cable |
| 46 | 50/70 Sqmm of 3.5 Core LT UG Cable |
| 47 | 3.5C x 120 Sqmm LT UG Cable |
| 48 | Material and labour for straight through joint at the cable in ground or End termination Joint at panel Connection with heat shrinkable type for underground LT cable 1100 volt complete all as specified and directed by Engineer in charge for the following sizes: |
| 49 | 16sqmm 4 core |
| 50 | 25/35/50 sqmm 3.5 core |
| 51 | 70/120 sqmm 3.5 core |
| 52 | 150/185 sqmm 3.5 core |
| 53 | 400 sqmm 3.5 core |
| 54 | Supply and laying DWC (Double wall corrugated) HDPE pipes of size internal dia 32mm laid in trenches complete, all as specified and directed by Engineer-in-Charge. |
| 55 | Material and labour for RCC Foundation type B-1 M20 graded aggregate of size 0.5m x 0.5m x 1.7m out of which 1500mm shall be below F.G.L(Finished Ground Level) using 04 Nos 10 mm dia steel reinforcementand rings using 8mm dia steel reinforcement alongwith supply and installation of 02 Nos 63mm dia PVC pipe for cable entry and cable exit. 04 Nos \"J\" Type foundation bolts shall be anchored in the foundation in such a way that 125mm length of bolt is projected above foundation including curing as required and soil excavation and backfilling all as directed and specified (10 for 300KLD and 10 for 500KLD) |
| 56 | Supply, Erection & Commissioning of 7M Hot Dip Galvanized Octagonal Single armed Pole in with top A/F 70mm bottom A/F 130mm made out of 3mm thick HT sheet along with base plate of size 220x220x12mm including 1500mm long aingle arm bracket made out of 48mm GI pipe M20 in PCD 205mm,700mm long and projected 125mm \"J\" type EN8 grade set of 04 Nos foundation bolts along with templates including provision of the following :- (a) MCB SO 6 A \"B\" Series 10KA Mounted on and including 3mm thick plastic laminated sheet-01 No (b) 04 way connector with GI nut bolts with locking arrangement weather and water proof control space. (c) The concrete for foundation,Reinforced and form work will measured and paid seperately (d) The excavation and earth work for foundation of pole shall be measured and paid seperately. Make : Bajaj model BOP-7030 or equivalent of Cromton/Philips/Wipro as approved by the GE.(10 for 300KLD and 10 for 500KLD) |
| 57 | Supply, Installation, Testing and Commissioning of LT Motor control panel indoor type totally enclosed with front and rear opening hinged doors with canopysloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 2 mm thick stainless steel sheet with gauge SS316, factory made as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 300Amps capacity RYBN insulated with sleeved insulation,indicating lampRYB, complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes,PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., all as specified and directed for suitable to accomodate the following items including supply and fix following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete with LT panel made by CPRI approved manufacturer. (For 300KLD Main STP). |
| 58 | (A) INCOMING --a) MCCB of Capacity - 200 Amps, 4 pole, 415V, 50 c/s 25 KA - 01 No.b) BUSBAR - 4 Nos. (Three for phase and one for neutral) made of copper mounted on FRP molded epoxy insulators with inter connection using copper cable of capacity 400 Amps. |
| 59 | (B) OUTGOING –a) MCCB 63 Amp 16 kA, TP - 06 Nos.(up to 12 hp motors)b) MCB 16 Amp 10 kA, TP – 05 Nos.(for 5 HP motors)c) MCB 10 Amp 10 KA, DP – 03 Nos.(for 2 hp motors) d) Star Delta Starter suitable15hp-08 Noe) Star Delta Starter for 5hp Motor- 05 Nosf)Star Delta Starter for 2hp Motor- 03 Nosg) Single phase preventor – 16 Nos.h) Thermal Over load relays for motor protection -16 NoS |
| 60 | (C) METERING –a) Voltmeter(0-500 V) digital type with selector switch - 1 Nob) Ammeter (0-100 amps) digital with CTs and selector switch - 1 No. c) Ammeter digital type with CTs and selector switch - 14 Nos.d) Indicator lamp LED based with lamp holder sets - 18 Nos. e) Multifunction Meter-01 Nos. |
| 61 | Supply, installing, testing and commissioning factory made and tested Motor Control Centre(MCC) LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system, hall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick Stainless Steel Sheet SS316 & suitable frame work/ support made out of 50 x 50 x 6 mm MS angle frame, front and Rear opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC Insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete, all as specified and as directed by Engineer-in-Charge(Location:- Pump Room Panel)Note The contractor shall subenit the Manufacturer\"s Design and drawings of LT panels. The panel manufacturer should have Govt. Approved CPRI CertificationThe scope of work also comprising of the following-(For 500 KLD Main STP). |
| 62 | (A) INCOMING --a) MCCB of Capacity - 250 Amps thermal magnetic release type, 4 pole, 415V, 50 c/s 36 KA-01 No. b) BUSBAR-4 Nos. (Three for phase and one for neutral) made of Aluminium mounted on FRP moulde epoxy insulators with inter connection using copper cable of capacity 400 Amps |
| 63 | (B) OUTGOING –(a) MCCB 63 Amp 16 kA, TP-05 Nos. (for 15 hp engine)b) MCB 63 Amp 10 kA, TP-02 Nos. (for 7.5 HP motors)c) MCB 20 Amp 10 kA, DP-03 Nos. (for 02 hp motors)e) Star Delta Starter suitable 15 HP -05 Nof) Star Delta Starter suitable 7.5 HP -02 Nog) Star Delta Starter for 2hp Motor - 03 Nosi) Push Button ON/OFF set-10 Nos.j) MCB SPN 32 A-02 Nos. (for SPN DB)k) MCB TP-25A-01 Nos (For Street Light Control)Note: Each Star/Delta starter shall have Single Phase Preventors-1 Nos, Thermal Over Load Relay-01 Nos, Protection MCB SP-01 Nos, Timer switch-01 Nos TP Contactors 20 A-06 Nos and 1 Pair of I NO +1 NC Auxiliary Contactor. |
| 64 | (C) METERING –a) Ammeter digital type with CTs and selector switch - 6Nos.b) Indicator lamp LED based with lamp holder sets - 10 Nos.c) Multifunction Meter-01 Nos.d) CT 2005 A -03 Nos |
| 65 | TREATED WATER SUPPLY |
| 66 | Material and labour for construction of valve chambers of size 1100x1100x1200 mm suitable up to 100 mm Dia pipe (internal dimension built in brick masonary on 15cm thick PCC foundation(1:4:8) type D-2 using 40 mm graded stone aggregate over 100 mm thick hard cor with brick work masionary in cement mortar 1:4 using \"B\" class bricks and rendering in cement mortar 1:4, 10 mm thick internally included exposed surface of external surfaces, MS cover made out of 3 mm thick MS sheet on iron angle framework made out of MS flat iron 25 x 6 mmx 300 mm long and 40 mm thick PCC coping 40 mm thick 1:2:4 type B-0 using 12.5 mm garded stone aggregate with handle hinges with locking arrangement & applying two coats of synthetic enamle paint over a coat of red oxide primer to all exposed steel surfaces complete all as specified and directed by the Engr-in-Charge. |
| 67 | Material and labour for construction of valve chamber of size 900 x 900 x 900 mm (internal dimensions built in brick masonary on 15 cm thick PCCfoundation (1 : 4 : 8) type D-2 using 40 mm graded stone aggregate over 100 mm thick hard cor with brick work masonary in cement mortar 1:4 using \"B\"class bricks and rendering in cement mortar 1: 4, 10 mm thick internally including exposed surfaces of external surfaces, MS cover made out of 3 mm thick MS sheet on angle iron framework made out of 40 x 40 x 3 mm duly embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with hold fast made out of MS flat iron 25 x 6 mm x 300 mm long and 40 mm thick PCC coping 40 mm thick 1:2:4 type B-0 using 12.5 mm graded stone aggregate with handle hinges with locking arrangement& applying two coats of synthetic enamel paint over a coat of red oxide primer to all exposed steel surfaces complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply and Fix Ductile iron mechanical (Collar type) Joint by Cutting The existing cast iron pipes and reducing to required length for insertion of new Mechanical joint for the Pipe size dia 250 mm complete all as specified and directed.Note : The rate for excavation of earth work will paid and measered seperately. |
| 69 | Supply and Fix Ductile iron mechanical (Collar type) Joint by Cutting The existing cast iron pipes and reducing to required length for insertion of new Mechanical joint for the Pipe size dia 150 mm complete all as specified and directed.Note : The rate for excavation of earth work will paid and measered seperately. |
| 70 | Supply and Fix Ductile iron mechanical (Collar type) Joint by Cutting The existing cast iron pipes and reducing to required length for insertion of new Mechanical joint for the Pipe size dia 100 mm complete all as specified and directed.Note : The rate for excavation of earth work will paid and measered seperately. |
| 71 | Supply, installing, testing and commissioning of centrifugal pumping set mounted on common base plate foundation with discharge of pumping set 1180 LPM at 20 mtr head directly coupled with electric motor of suitable capacity for above pumping set complete with all accessories: - (7.5 HP, 3 Phase) complete all as specified and as directed. Make shall be Kirloskar/Beacon/Crompton (i)Rain guard protection for pumps with aluminium of non corrosive sheet.(ii)PCC platform in Cement Concrete 1:2:4 Type B-1 using 20mm graded stone aggregate 30cm above ground level including necessary eye bolts etc. as per manufacturer recommendation.(iii)Including foot valve and non return valve and butter fly valve on suction and delivery.(iv) Necessary power cable and control cable connections(v) Electromagnetic Flow meter -1 No for both pump (running+standby) in common header.Make shall be \"Flowtech or its equivalent with provision of connectivity to CPCB and UPPCB server to communicate the real data and its record shall be maintained.(vi) Foot valve 80mm dia -01 No, Make Shall be : Kirloskar/Leader or its equivalent. (vii)Non return valve 80 mm dia-01 No. Make Shall be : Kirloskar/Leader or its equivalent. (viii)Butter fly valve 80 mm dia - 01 No.Make Shall be : Kirlokar/Leader or its equivalent |
| 72 | Supplying, laying, connecting and testing of UPVC pipes 32mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified. |
| 73 | Supply and fix32mm size ball valves suitable forUPVC pipe 40 Sch complete. |
| 74 | Supply & fixing Air release valve double( isolated type) with flanged ends suitable for 80 mm bore tube ISI (IS 14846) marked complete all as specified. |
| 75 | M&L forboring of holes under roads / pavements / hard standing by trench less technology using ultra sound technuique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure (50 RM for 300KLD and 50 for 500KLD) |
| 76 | Supply & fixing Air release valve double( isolated type) with flanged ends suitable for 50 mm bore tube ISI (IS 14846) marked complete all as specified. |
| 77 | Supply, Installation, Testing and Commissioning of LT panel boardwith suitable angle iron stand for mounting made out of 2 mm thick CRCA sheet , front openable CPRI approved duly powder coated after minimum 7 tank process of cleaning, complete prewired and consist of the following(for 500 KLD plant -1, 300 KLD - 1)Incomer: 32 Amps MCB TPN, 415V, 50 Hz, 10 KA - 01 NoBus bar-200 amps Aluminium -04 nosIndicator lamp-RYB-01 setDigital Multifunction meter-01 NoOutgoingsi) MCB TP-20 Amps , 415V, 50 Hz, 10 KA-02 Noii)Star delta starter suitable for 10 HP pump set complete with Timer , SPP, OL protection etc complete -02 nosiii) Inicator Lamp for ON/OFF indication set of two -02 nosiv) Digital Ammeter 0-50 amps with sith suitable CT\"s-02 nov) Digital Voltmeter 0-500 Volts-01 No. |
| 78 | Material and labour for Construction of valve chamber of internal size 750 x 750 x 750mm suitable for 80mm dia sluice valve including necessary earth work excavation PCC 1:4:8 in foundation type D2 using 40mm graded stone aggregate, brick wall in CM 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in CM 1:4 including provision of MS sheet cover 3.0mm thick with MS angle frame 25 x 25 x 3mm all round and at diagonals of size 40 x 40 x 6mm and also MS plate welded to MS angle as shown in drawing, embedded in concrete with suitable hinges and locking arrangements, including two coats of synthetic enamel paint over a coat of red oxide primer necessary excavation earth work etc, all as specified and as directed. (3 for 500KLD and 3 for 300KLD) |
| 79 | Supply, installing, testing and commissioning of monoblock centrifugal pumping set mounted on common base plate foundation with discharge of pumping set 710 LPM at 20 mtr head directly coupled with electric motor of suitable capacity for above pumping set complete with all accessories: - (5 HP, 3 Phase) complete all as specified and as directed. Make shall be Kirloskar/Beacon/Crompton (i)Rain guard protection for pumps with aluminium of non corrosive sheet.(ii)PCC platform in Cement Concrete 1:2:4 Type B-1 using 20mm graded stone aggregate 30cm above ground level including necessary eye bolts etc. as per manufacturer recommendation.(iii)Including foot valve and non return valve and butter fly valve on suction and delivery.(iv)Necessary power cable and control cable connections(v) Electromagnetic Flow meter -1 No for both pump (running+standby) in common header.Make shall be \"Flowtech or its equivalent with provision of connectivity to CPCB and UPPCB server to communicate the real data and its record shall be maintained.(vi)Foot valve 80mm dia -01 No, Make Shall be : Kirloskar/Leader or its equivalent. (vi)Non return valve 80 mm dia-01 No. Make Shall be : Kirloskar/Leader or its equivalent. (vii)Butter fly valve 80 mm dia - 01 No.Make Shall be : Kirlokar/Leader or its equivalent. |
| 80 | ROAD |
| 81 | M&L for providing and laying of hot applied thermo plastic compound 2.5 mm thick including reflectorising glassbeads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes. |
| 82 | MANNING & OPERATION OF 02 Nos STP OF CAPACITY EACH 0.3 MLD and 0.5 MLD |
| 83 | Manning and operation of STP plant 300 KLD capacity consisting of two shifts including Sundays and holidays including all connected electrical & Sewage Pumps items such as main switch, starter, change over switch, MCCB, voltmeter, ammeter, panel board, etc., Sewage water pump, valve system, controlling system, daily checking, leakage, checking noise, cleaning of plant and its sorrounding area etc, by one FGM(skilled) per shift for 02 shifts in a day all as specified and directed by Engr-in-charge.Shift DetailsTRADEMAN: 01 FGM x 02 shift per day =02 FGM per day Note:- (i) Comprehensive maintenance of plant including replacement of any defective/wornout parts are covered under defect liability period of two years. (ii)This item shall be taken as 20% of total amount quoted for the job i.e in item 2.00 for payment purpose. Yearly breakdown payment against this item shall be made as per following schedule during the period of Ten years. (a)After 1st year - 2% (b)After 2nd year- 2% (c)After 3rd year - 2% (d)After 4th year - 2% (e)After 5th year - 2% (f) After 6th year - 2% (g)After 7th year - 2% (h)After 8th year - 2% (j) After 9th year- 2% (k)After 10th year - 2% NOTE:- Yearly amount as above shall be paid in equal installments every month. |
| 84 | Manning and operation of STP plant 500 KLD capacity consisting of two shifts including Sundays and holidays including all connected electrical & Sewage Pumps items such as main switch, starter, change over switch, MCCB, voltmeter, ammeter, panel board, etc., Sewage water pump, valve system, controlling system, daily checking, leakage, checking noise, cleaning of plant and its sorrounding area etc, by one FGM(skilled) per shift for 02 shifts in a day all as specified and directed by Engr-in-charge.Shift DetailsTRADEMAN: 01 FGM x 02 shift per day =02 FGM per day Note:- (i) Comprehensive maintenance of plant including replacement of any defective/wornout parts are covered under defect liability period of two years. (ii) This item shall be taken as 20% of total amount quoted for the job i.e in item 3.00 for payment purpose. Yearly breakdown payment against this item shall be made as per following schedule during the period of Ten years. (a)After 1st year - 2% (b)After 2nd year- 2% (c)After 3rd year - 2% (d)After 4th year - 2% (e)After 5th year - 2% (f) After 6th year - 2% (g)After 7th year - 2% (h)After 8th year - 2% (j) After 9th year- 2% (k)After 10th year - 2% NOTE:- Yearly amount as above shall be paid in equal installments every month. |
| 85 | Notes for item 24.01 and 24.02:- (a) The contractor shall be responsible for comprehensive maintenance of STP including renewal/ replacement of parts, fittings/ fixtures required for smooth functioning of the plant during first two years of defect liability period.(b) The Contractor shall employ FGM having minium ITI qualification from Govt. Recognised institute with adequate knowledge & minimum 2 years experience in maint/operation of AC plants. The operator must competent to carry out the minor maint all as directed. (Tota number of operators required per day are 02 nos.) (c) Contractor shall pay the wages to the employees through e-payment i.e Adhaar linked bank accounts (credit to their bank account) Engineer-in-charge shall ensure that e-payment made to employees and their wages shall be not less than minimum wages fixed by state Govt. or Central Govt. whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engr-in-charge and the same shall be kept in record duly verified.(d) It is the responsibility of the contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevailing scales as laid down by Ministry of labour for all operator/helper (as applicable and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record. The quoted rates shall be deemed to include all of above provisions. In case contractor fails to produce the proof of EPF, the same shall be recovered from his dues as per the prevailing sacle plus 15 percent. (e) The contractor shall maintain all registers under various rules, and shall be produced to the Engineer-in Charge as well as officers detailed by central labour department. (f) The unit rate quoted shall be deemed to be included for cost of labour for daily routine maintenance for trouble free functioning of installation. (g) In case of any abnormal noise/ complaint the plant should be put off and same should be brought to the notice of Engr-in-charge. (h) The operator employed by the contractor shall be capable of carrying out minor repair/ maintenace should have experience in operation of STP as applicable.(j) The quoted rate shall be deemed to be inclusive of cotton waste, cleaning material etc & Contractor will ensure general area cleanliness and upkeep of the installation on daily basis. (k) The quoted rate is deemed to be inclusive of tools & testing instruments required for operation & maintenance of STP plants. (l) The rate quoted shall deemed to be inclusive of safety gear & recquired tools for minor maintenance. In case of failiure to provide tools kit & safety kit (spanner sets, hand gloves), a penalty of 3000/- will be recovered and levied. (m) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved. In case failure, a penalty of Rs 2000/- per uniform will be levied and recovered from their dues. (n) In case of failiure due to absence of operative staff, the contractor shall be liable to pay compensation at twice the cost of a day\"s Manning & Operation derived from pro rate of Sch \"A\" quoted rates.(o) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsover maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly. (p) The contractor shall provide board at proper location near each installations duly writing the name of operators and Mobile Numbers shift wise. (q) In case of non funtion of STP Plant panel recovery @ 3000 per day shall be effected 24 hrs after the defect is noticed or notified. |
| 86 | COMPREHENSIVE MAINTENANCE OF 02 NOs STP OF CAPACITY EACH 0.3 MLD and 0.5MLD |
| 87 | Annual comprehensive maintenance of STP OF CAPACITY 0.3 MLD complete by deploying qualified manpower and material as reqd. |
| 88 | 1 year after expiry of defects liability period |
| 89 | 1 year after completion of BOQ item No. 26.101 here-in-before |
| 90 | 1 year after completion of BOQ item No. 26.102 here-in-before |
| 91 | 1 year after completion of BOQ item No. 26.103 here-in-before |
| 92 | 1 year after completion of BOQ item No. 26.104 here-in-before |
| 93 | 1 year after completion of BOQ item No. 26.105 here-in-before |
| 94 | 1 year after completion of BOQ item No. 26.106 here-in-before |
| 95 | 1 year after completion of BOQ item No. 26.107 here-in-before |
| 96 | Annual comprehensive maintenance of STP OF CAPACITY 0.5 MLD complete by deploying qualified manpower and material as reqd. |
| 97 | 1 year after expiry of defects liability period |
| 98 | 1 year after completion of BOQ item No. 26.201 here-in-before |
| 99 | 1 year after completion of BOQ item No. 26.202 here-in-before |
| 100 | 1 year after completion of BOQ item No. 26.203 here-in-before |
| 101 | 1 year after completion of BOQ item No. 26.204 here-in-before |
| 102 | 1 year after completion of BOQ item No. 26.205 here-in-before |
| 103 | 1 year after completion of BOQ item No. 26.206 here-in-before |
| 104 | 1 year after completion of BOQ item No. 26.207 here-in-before |
| 105 | Notes (for item no 25.000 to 25.208)(i) Regular oiling of all machinery and moving parts(ii) Regular greasing of all machinery and moving parts(iii) Carrying out regular preventive maintenance of all electrical panels and their parts and repairs /replacement of electrical worn out parts if needed(iv) Topping up of filter media as and when required or as per manufacturers recommendations(v) Topping up / changing of activated carbon as and when reqd or as per manufacturers recommendations(vi) Changing of ultra filtration membrane as and when required or as per manufacturers recommendations(vii) Carrying out daily, weekly, monthly, quarterly, half yearly and yearly maintenance as per manufacturers recommendations(viii) Defective material produced after repairs/ replacement of worn out or defective parts will be departments property and shall be deposited to E/M store yardNote-(i) Non functioning of STP due to any problem / due to non functioning of machinery or defect in plant will invite penalty at Rs 15000/- per day.(ii) Cost of replacement of filter media, activated carbon and ultra filtration membrane as and when required or as per manufacturers recommendations is inclusive of rate quoted for AMC.(iii) The dry sludge sewage cakes shall be removed from site by contractor.(iv) Defective material produced after repairs/ replacement of item if any will be departments property and same will be deposited to E/M store yard |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail