| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR No 4.1.8 |
| 3 | Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) DSR 6.1.2 |
| 4 | Reinforced cement concrete work in beams,suspended floors,roofshaving slope up to 15°landings,balconies,shelves,chajjas,lintels,bands,plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources :3 graded stone aggregate 20 mm nominal size derived from natural sources). 5.3 |
| 5 | Steel reinforcement for R.C.C.work including straightening,cutting,bending,placing in position and binding all complete upto plinth level.Thermo- Mechanically Treated bars of grade Fe-500D or more. DSR No 5.22.6 |
| 6 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides offoundation etc. complete for all lift. DSR No 2.25(a) |
| 7 | Brick Work with common burnt clay ( non modular) bricks of class- 150 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 ( 1 cement : 6 coarse sand) DSR 6.4.2 |
| 8 | 12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand) DSR No 13.4.2 |
| 9 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor) 11.3.1 |
| 10 | Providing and laying Vitrified tiles in skirting in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting,riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement:3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 11.46.2 |
| 11 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR 8.31 |
| 12 | Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.80 |
| 13 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR No 13.46.1 |
| 14 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L- Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) DSR 10.15.1 |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butthinges with necessary screws |
| 16 | 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an an ever shade: two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 |
| 17 | Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests water closet squatting pan ...making good the walls and floors wherever required. D.S.R.-17.1.1 |
| 18 | Providing and fixing white vitreous china flat black or wall corner type lipped front urinal basin of 430O260O350 mm and 340O410O350 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P brass preaders with brass unions and G.I clamps complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : DSR No. 17:4.1 one urinal basin with 5 litre white P.V.C automatic flushing cistern |
| 19 | Providing and fixing wash basin C.I, brackets, 15mm C.P brass pillar taps. 32mm C.P, brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: DSR No. 17.7:1 White Vitreous China Wash basin size 630O450 mm with a pair of 15mm C.P. brass pillar taps |
| 20 | Providing and fixing 600O450mm brevelled edge mirrior of superior glass (of approved quality) Complete with 6 mm thick hard board ground fixed to wodden cleats with C.P. brass screws and washers complete DSR 17.31 |
| 21 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. concealed work, including cutting chases and making good the walls etc. 20 mm dia. nominal bore. DSR-18.8.2 |
| 22 | 25 mm dia. nominal bore. DSR-18.8.3 |
| 23 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore. DSR-18.15.1 |
| 24 | 20 mm nominal bore. DSR-18.15.2 |
| 25 | Providing and placing on terrace (at all floor levels) polyethylene water….pipes but without fittings and the base support for tank.DSR 18.48 |
| 26 | Providing and fixing 15 mm dia. Nominal size C.P. brass bib cock of approved quality conforming to IS:8931.DSR-18.49.1 |
| 27 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. DSR-18.53.1 |
| 28 | 110 MM PVC PIPE for rain water |
| 29 | Wiring for light point/ fan point/ exhaust fan point/ call bell point/plug point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 30 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required for inverter Wiring:- 1x1.5 mm |
| 31 | S/F of LED tube light batten Fitting suitable for upto 1X22watt LED tube light on surface.complete in all respect. |
| 32 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular swifch, connections etc. as required. |
| 33 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required for AC/Power |
| 34 | 2+4 way, SPN, single door, MCB DB |
| 35 | 2+10 way, SPN, single door, MCB DB |
| 36 | 4 way (4+12), TPN, MCB DB, double door, horizontal type |
| 37 | 6 A, to 32 A, ratings , SP MCB, \"C\" curve, 10 KA breaking capacity |
| 38 | S/F of MCB blanking Plate for DB |
| 39 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 40 | S/L of 10 sqmm 3.5 core Al conductor pvc insulated armoured served sheathed cable 1100 V grade. Complete in all respect. |
| 41 | 63 A, TPN, switch disconnector fuse unit (Panel mounted type) with ISI marked HRC fuses |
| 42 | S/F of electronic fan regulator 120-280 V ISI marked |
| 43 | S/F of LED Bulb 15 watt |
| 44 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 45 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 46 | Supply and Installation of Exhaust Fan |
| 47 | G.S.T Please Enable Macros to View BoQ information |