}

Tender For Construction Of Automated Testing Station/Inspection And Certification Centre At Lamlai, Imphal East (Central Components And State Components), Imphal West-Manipur

Tender Notice

52543308
Tender For Construction Of Automated Testing Station/Inspection And Certification Centre At Lamlai, Imphal East (Central Components And State Components)
Tender
Indian
Manipur
Imphal West
15-12-2025

Tender Details

Construction Of Automated Testing Station/Inspection And Certification Centre At Lamlai, Imphal East (Central Components And State Components)-STATE COMPONENT 2 I) Sh: Construction ofCompound Fencing, Retaining wall & 2 Nos. Gate) 3 A - Construction of gates - 2 Nos: 4 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 5 2.8.1 All kinds of soil. 6 2.24 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 7 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 8 4.1.61:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 9 4.2 Providing and laying cement concrete in retaining walls, return walls (any thickness) including attached pilasters, columns, piers, abutmets, pillars, posts, struts.buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc upto floor five level, excluding the cost of centering, shuttering and finishing: 10 4.1.21 :2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 11 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 12 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 13 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 14 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 15 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 16 5.20.2Thermo-Mechanically Treated bars 17 5.20 ASteel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 18 5.20 A.2Thermo-Mechanically Treated bars 19 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 20 5.9.1Foundations, footings, bases of columns etc. and mass concrete. 21 5.9.6Columns, Pillars, Piers, Abutments, Posts and Struts. 22 5.9.14 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills.string courses, bands, copings, bed plates, anchor blocks and the like. 23 6.9Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in . 24 6.9.1Cement mortar 1:3 (1 cement : 3 coarse sand) 25 10.24Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 26 10.24.2In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works . 27 Providing and fixing cast iron Arrow Head. 28 13.112mm cement plaster of mix :- 29 13.1.11:4 ( 1 cement : 4 fine sand) 30 13.58Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 31 13.33Finishing walls with textured exterior paint of required shade : 32 13.33.1New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 33 13.36.3Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.80 litr/10 sqm of approved brand and manufacture. 34 B-CONSTRUCTION OFRETAINING WALL: 35 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 36 2.8.1 All kinds of soil. 37 2.24 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 38 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 39 4.1.7 1:5:10 ( 1 Cement: 5 coarse sand: 10 graded stone aggregate cum 40 mm nominal size) 40 7.1 Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1 :6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with 41 7.1.1 : Cement mortar 1 :6(1 cement: 6 coarse sand) 42 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 43 5.9.2Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 44 Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment,wing wall/retum wall with 100 mm dia pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face.Complete as per drawing and Technical specifications 45 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and retum wall to the full height compacted to a firm condition complete as per drawing and technical specification. 46 C) Construction of G.I. Netting Wire Fencing 47 2.8 Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan) including getting out the excavated soil and disposal of surplus excavated soil as directed, withn a lead of 50m. 48 2.8.1 All kinds of soil. 49 2.24 Filling available excavated earth (excluding rock) in trenches ,plinth sides of foundation etc. in layers not exceeding 20cm in depth, consolidating each depositing layer cum by raming and watering, lead upto 50m and lift upto 1.5m 50 4.1 Providing and Laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level: 51 4.1.7 1:5:10 ( 1 Cement: 5 coarse sand: 10 graded stone aggregate cum 40 mm nominal size) 52 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering ,shuttering,finishing and reinforcement - All work upto plinth level: 53 5.1.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 54 5.20 Reinforcement for R.C.C Work including straihtening, cutting, bending, placing in position and binding all complete upto plinth level. 55 5.20.2Thermo-Mechanically Treated bars 56 5.9 Centering and shuttering including strutting, propping etc.and removal of form for: 57 5.9.1Foundations, footings, bases of columns etc. and mass concrete. 58 10.24Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 59 10.24.2In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works . 60 13.36.3. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied@ 0.80 ltr/10 sqm of approved brand and manufacture. 61 S/F galvanised steel barbed wire, weighing 9.38kg/100m straining and fixing to any type of standard rails straining bolts i/c securing with and provision of galvanised mild steel wire, staple or steel pins etc as directed (Posts and struts of wood, concrete, steel and straining bolts shall be paid seperately). 62 Supplying & fixing 4mm galvanised iron wire netting 100x100mm mesh made up into mattresses or cages, lapped wired and laid in position i/c closing after filling. 63 II) Sh: Construction of Security Block. 64 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 65 2.8.1 All kinds of soil. 66 2.24 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 67 2.26Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete. 68 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 69 4.1.7 1:5:10 ( 1 Cement: 5 coarse sand: 10 graded stone aggregate cum 40 mm nominal size) 70 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 71 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 72 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 73 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 74 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). 75 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 76 5.20.2Thermo-Mechanically Treated bars 77 5.20 ASteel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 78 5.20 A.2Thermo-Mechanically Treated bars 79 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 80 (a)5.9.1Foundations, footings, bases of columns etc. and mass concrete. 81 (b)5.9.6Columns, Pillars, Piers, Abutments, Posts and Struts. 82 (c)5.9.15Edges of slab and breaks in floors and walls. 83 5.9.15.1Under 20 cm wide. 84 (d)5.9.19Suspended floors, roofs landings, balconies and access platform, with water proof ply 12 mm thick. 85 (e)5.9.20Lintels, Chajjas, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick. 86 6.1Brick work with 1st class common burnt clay F.P.S. (non modular) bricks of class in foundation and plinth in : 87 6.1.1Cement mortar 1:4 (1 cement : 4 coarse sand) 88 6.9Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in . 89 6.9.1Cement mortar 1:3 (1 cement : 3 coarse sand) 90 9.1Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 91 9.1.1Local best quality Teak wood. 92 9.6 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. 93 9.6.1Local best quality Teak wood. 94 9.6.1.135 mm thick shutters 95 9.22P/F MS grills of required pattern in frames of windows etc. with MS flat, square or round bars etc. including priming coat with approved steel primer all complete. 96 9.22.2Fixed to openings/wooden frames with rawl plugs screws etc. 97 9.26 Providing 40x5 mm. flat iron hold fast 40 cm. i/c fixing to frames with 10 mm. dia. Nuts & wooden plugs and embedding to cement concrete block 30x10x15 cm.1:3:6 (1 cement : 3 course sand : 6 stone agrt. 20 mm. nominal gauge) 98 9.62 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 99 9.62.1300 x 16 mm. 100 9.63 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 101 9.63.2250 x 10 mm. 102 9.63.4150 x 10 mm. 103 9.65 Providing and fixing aluminium handles,ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 104 9.65.1125 mm. 105 9.65.2100 mm. 106 11.2 Cement concrete flooring 1 :2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. 107 11.33Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut wlth the zero chipping diamond cutter only. Laying of tiles will be done with the notch towel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily. 108 11.33.1Double charge vitrified tile polished finish of size 109 11.33.1.1Size of Tile 600x600 mm 110 11.36 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer),with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry@ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 111 11 .36.2. Size of Tile 600x600 mm 112 13.412mm cement plaster of mix :- 113 13.4.11:4 ( 1 cement : 4 coarse sand) 114 13.10 15mm cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall. 115 13.58Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 116 13.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. 117 13.29.1 New work (two or more coats) over and i/c priming coat with cement primer. 118 13.31 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. 119 13.31.1 Water thinnable cement primer 120 13.34Finishing walls with Acrylic Smooth exterior paint of required shade : 121 13.34.1New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm. 122 13.37 Applying priming coat: 123 13.37.1With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 124 13.36.2Painting wood work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.75 litr/10 sqm of approved brand and manufacture. 125 13.36.3Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.80 litr/10 sqm of approved brand and manufacture. 126 Making plinth protection 50 mm. in c.c. 1:3:6 (1 cement : 3 course sand : 6 graded stone aggrt. 20 mm. nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finished the top smooth. 127 IEI for security block 128 Wiring for light point/fan point/call bell point with 1.5 sq. mm., FRLS PVC insulated copper conductor single core cable in surface/recessedmedium class PVC conduit with modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 129 (ii). Group B 130 (iii). Group C 131 Wiring for light plug/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mmFRLSPVCinsulatedcopperconductorsingle core cable for loop earthing as required. 132 Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor,single core cable in surface/recessed medium class PVC conduit as required. 133 (ii). 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 134 (iv). 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 135 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin , 5/6 Amps modular socket outlet and 5/6 Amps modular switch , connection etc . as required . 136 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin , 15/16 Amps modular socket outlet and 15/16 Amps modular switch , connection etc . as required . 137 Supply and fixingfollowing way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( But withoy MCB/ RCCB/ Isolator).- 6 way, double door. 138 Supplying and fixing following rating, double pole 240V isolator in the existing MCB DB complete with connection testing and commissioning etc. as reqd. 139 Supplying and fixing 5 amp. to 32 amp. rating 240V/415V, 10KAC curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection, testing and commissioning etc. as reqd. - Single pole. 140 P/F 32A TP & N dis-connector fuse switch unit inside the existing cubicle panel board with ISI marks H.R.C. fuses including drilling holes in thecubicle panel board, makingconnection as reqd. 141 Supplying of high efficient 9WZiva surface LED down light. (Make Havells -ZIVASURRDDLR9WLED840S). 142 Supplying of 10W LED Hexa IP66 bulkhead. (Make - Havells - Ziva surface down light. ( Make Havells -HEXAFT10WLED857SSYMBOPC). 143 Earthing with Copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. 144 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required. 145 III) Sh: Land Development. 146 2.2Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clodes watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m. 147 2.2.1 All kinds of soil. 148 IV) SH:Construction of Culvert and one sided wall Internal Drain near Retaining wall. 149 A - CONSTRUCTION OF DRAINS: 150 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 151 2.8.1 All kinds of soil. 152 2.23 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 153 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level : 154 4.1.7 1:5:10 ( 1 Cement: 5 coarse sand: 10 graded stone aggregate cum 40 mm nominal size) 155 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 156 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 157 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 158 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 159 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 160 5.20.2Thermo-Mechanically Treated bars 161 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 162 5.9.1Foundations, footings, bases of columns etc. and mass concrete. 163 5.9.2 Walls (any thickness ) including attached pilasters, buttresses, plinth and the string courses etc. 164 B - CONSTRUCTION OF CULVERTS: 165 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 166 2.8.1 All kinds of soil. 167 2.23 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 168 Providing, laying and compacting granular base / sub-base according to lines, grades and cross sections by using naturally occurred sand gravel/conforming to IRC-Grd-II of MOST specification flee from organic or other deleterous constituent spread with motor grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding l50mm (spread thickness) i/c rolling of the road surface to proper level and grades 30 cm width edging on both side etc. complete as directed by Engineer-incharge. 169 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 170 4.1.7 1:5:10 ( 1 Cement: 5 coarse sand: 10 graded stone aggregate cum 40 mm nominal size) 171 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 172 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 173 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 174 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 175 5.3Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). 176 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 177 5.20.2Thermo-Mechanically Treated bars 178 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 179 (a)5.9.1Foundations, footings, bases of columns etc. and mass concrete. 180 (b)5.9.2 Walls (any thickness ) including attached pilasters, buttresses, plinth and the string courses etc. 181 (c)5.9.3 Suspended floors, roofs, landings, balconies and access platform. 182 V) Sh: Construction of Electrical Sub-Station. 183 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 184 2.8.1 All kinds of soil. 185 2.23 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 186 2.25Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete. 187 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 188 4.1.7 1:5:10 ( 1 Cement: 5 coarse sand: 10 graded stone aggregate cum 40 mm nominal size) 189 4.8 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). 190 4.11 Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1. 7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 191 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 192 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 193 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 194 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 195 5.3Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). 196 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 197 5.20.2Thermo-Mechanically Treated bars 198 5.20 ASteel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 199 5.20 A.2Thermo-Mechanically Treated bars 200 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 201 (a)5.9.1Foundations, footings, bases of columns etc. and mass concrete. 202 (b)5.9.6Columns, Pillars, Piers, Abutments, Posts and Struts. 203 (c)5.9.15Edges of slab and breaks in floors and walls. 204 5.9.15.1Under 20 cm wide. 205 (d)5.9.19Suspended floors, roofs landings, balconies and access platform, with water proof ply 12 mm thick. 206 (e)5.9.20Lintels, Chajjas, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick. 207 6.1Brick work with common burnt clay F.P.S. (non modular) bricks of class in foundation and plinth in : 208 6.1.1Cement mortar 1:4 (1 cement : 4 coarse sand) 209 6.9Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in . 210 6.9.1Cement mortar 1:3 (1 cement : 3 coarse sand) 211 18.1 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cteatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-incharge.(Glazing and panelling to be paid for separately): 212 18.1.1 For fixed portion. 213 18.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 214 18.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item 215 18.3.1 With float glass panes of 5.50 mm thickness 216 9.22P/F MS grills of required pattern in frames of windows etc. with MS flat, square or round bars etc. including priming coat with approved steel primer all complete. 217 9.22.2Fixed to openings/wooden frames with rawl plugs screws etc. 218 9.26 Providing 40x5 mm. flat iron hold fast 40 cm. i/c fixing to frames with 10 mm. dia. Nuts & wooden plugs and embedding to cement concrete block 30x10x15 cm.1:3:6 (1 cement : 3 course sand : 6 stone agrt. 20 mm. nominal gauge) 219 9.62 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 220 9.62.1300 x 16 mm. 221 9.63 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 222 9.63.2250 x 10 mm. 223 9.63.3150 x 10 mm. 224 9.65 Providing and fixing aluminium handles,ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 225 9.65.1125 mm. 226 9.65.2100 mm. 227 10.6 Supplying and fixing rolling shutters of approved make, made of required size tvi.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. 228 (a) 80x1.25nmm M.S. laths with 1.25 mm thick top cover 229 10.7 P/F ball bearing for rolling shutters 230 11.2 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand : 4 graded stone stone aggregate) finished with a floating coat of neat cement slurry, but excluding the cost of noising of steps etc. complete. 231 11.2.1 40mm thick with 20mm nominal size stone aggregate. 232 11.32 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorptions less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. 233 11.36 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer),with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry@ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 234 11.36.1 Size of Tile 500x500 mm 235 13.412mm cement plaster of mix :- 236 13.4.11:4 ( 1 cement : 4 coarse sand) 237 13.10 15mm cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall. 238 13.58Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 239 13.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. 240 13.29.1 New work (two or more coats) over and i/c priming coat with cement primer. 241 13.31 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. 242 13.31.1 Water thinnable cement primer 243 13.34Finishing walls with Acrylic Smooth exterior paint of required shade : 244 13.34.1New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm. 245 13.46 Painting with aluminium paint of approved brand and manufacture to give an even shade: 246 13.46.1. Two or more coats on new work 247 13.36.3Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.80 litr/10 sqm of approved brand and manufacture. 248 4.15 Making plinth protection 50 mm. in c.c. 1:3:6 (1 cement : 3 course sand : 6 graded stone aggrt. 20 mm. nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finished the top smooth. 249 B - Construction of fencing: 250 2.8 Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan) including getting out the excavated soil and disposal of surplus excavated soil as directed, withn a lead of 50m. 251 2.8.1 All kinds of soil. 252 2.24 Filling available excavated earth (excluding rock) in trenches ,plinth sides of foundation etc. in layers not exceeding 20cm in depth, consolidating each depositing layer cum by raming and watering, lead upto 50m and lift upto 1.5m. 253 2.25Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete. 254 4.1 Providing and Laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level: 255 4.1.61:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 256 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering ,shuttering,finishing and reinforcement - All work upto plinth level: 257 5.1.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 258 5.20 Reinforcement for R.C.C Work including straihtening, cutting, bending, placing in position and binding all complete upto plinth level. 259 5.20.2Thermo-Mechanically Treated bars 260 5.9 Centering and shuttering including strutting, propping etc.and removal of form for: 261 5.9.20Lintels, Chajjas, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick. 262 10.24Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 263 10.24.2In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works . 264 11.2 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand : 4 graded stone stone aggregate) finished with a floating coat of neat cement slurry, but excluding the cost of noising of steps etc. complete. 265 11.2.1. 40mm thick with 20mm nominal size stone aggregate. 266 13.36.3. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied@ 0.80 ltr/10 sqm of approved brand and manufacture. 267 Supplying & fixing 4mm galvanised iron wire netting 100x100mm mesh made up into mattresses or cages, lapped wired and laid in position i/c closing after filling. 268 IEI for electrical sub statione. 269 Wiring for light point/fan point/call bell point with 1.5 sq. mm., FRLS PVC insulated copper conductor single core cable in surface/recessedmedium class PVC conduit with modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 270 (i). Group A 271 (ii). Group B 272 (iii). Group C 273 Wiring for light plug/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mmFRLSPVCinsulatedcopperconductorsingle core cable for loop earthing as required. 274 Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor,single core cable in surface/recessed medium class PVC conduit as required. 275 (ii). 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 276 (iv). 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 277 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin , 5/6 Amps modular socket outlet and 5/6 Amps modular switch , connection etc . as required . 278 Supply and fixingfollowing way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( But withoy MCB/ RCCB/ Isolator).- 6 way, double door. 279 Supplying and fixing following rating, double pole 240V isolator in the existing MCB DB complete with connection testing and commissioning etc. as reqd. 280 Supplying and fixing 5 amp. to 32 amp. rating 240V/415V, 10KAC curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection, testing and commissioning etc. as reqd. - Single pole. 281 P/F 32A TP & N dis-connector fuse switch unit inside the existing cubicle panel board with ISI marks H.R.C. fuses including drilling holes in thecubicle panel board, makingconnection as reqd. 282 Supplying of 300 mm (900/1200) RPM T. Force 1Pexhaust fan ( Make - Havells-FA06). 283 Installation exhaust fan in the existing opening including making good the damage, connection, testing, commissioning etc. as required. - Upto 450 mm sweep. 284 Supplying of high efficient 9WZiva surface LED down light. (Make Havells -ZIVASURRDDLR9WLED840S). 285 Supplying of 10W LED Hexa IP66 bulkhead. (Make - Havells - Ziva surface down light. ( Make Havells -HEXAFT10WLED857SSYMBOPC). 286 Earthing with Copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. 287 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required. 288 VI) Sh: Construction of Internal Road. 289 2.6Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth1.5 m in width as well as 10 sqm on plan) includinggetting out and disposal of excavated earth,lead upto 50 m and lift upto 1.5m, as directed by the Engineer in charge. 290 2.8.1 All kinds of soil. 291 Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications A Stone/Boulder 292 Providing, laying and compacting Granular Base/Sub-base with naturally occurring Sand Gravel Material free from organic ore other deleterious constituent spreading with Motor Grader and compacted by rolling with power roller of 8 to 10 tonne capacity in layers not exceeding 150mm (spread thickness). 293 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level : 294 4.1.5 1:3:6 ( 1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) 295 11.37Providing and laying factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Enginneer-in-charge. 296 11.37.2 80mm thick 297 7.1 (vol ii) Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408). Using Concrete Batching and Mixing Plant 298 (ii) PCC M-20 for Kerb Cast-in- situ 299 3.23 (vol ii)Sub Surface Drains with Perforated Pipe (Construction of subsurface drain with perforated pipe of 100 mm intemal diameter ofmetay asbestos cement/ cement concrete/PvC, closely jointed, perforations ranging from 3 mm to 6 mm depending upon size of material surrornding the pipe, with 150 mm bedding below the pipe and 300 mm cushion above the pipe, cross section of excavation 450 x 550 mm. Excavated materiol to be utilised in roadway ar site ) 300 VII) Sh: Construction of Toilet Block & U/G water tank 301 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 302 2.8.1 All kinds of soil. 303 2.23 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 304 2.25Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete. 305 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 306 4.1.21:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 307 4.1.7 1:5:10 ( 1 Cement: 5 coarse sand: 10 graded stone aggregate cum 40 mm nominal size) 308 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 309 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 310 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 311 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 312 5.3Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). 313 (a) 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 314 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 315 5.20.2Thermo-Mechanically Treated bars 316 5.20 ASteel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 317 5.20 A.2Thermo-Mechanically Treated bars 318 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 319 (a)5.9.1Foundations, footings, bases of columns etc. and mass concrete. 320 (b)5.9.2 Walls (any thickness ) including attached pilasters, buttresses, plinth and the string courses etc. 321 (c)5.9.6Columns, Pillars, Piers, Abutments, Posts and Struts. 322 (d)5.9.15Edges of slab and breaks in floors and walls. 323 5.9.15.1Under 20 cm wide. 324 (e)5.9.19Suspended floors, roofs landings, balconies and access platform, with water proof ply 12 mm thick. 325 (f)5.9.20Lintels, Chajjas, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick. 326 6.1Brick work with common burnt clay F.P.S. (non modular) bricks of class in foundation and plinth in : 327 6.1.1Cement mortar 1:4 (1 cement : 4 coarse sand) 328 6.9Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in . 329 6.9.1Cement mortar 1:3 (1 cement : 3 coarse sand) 330 9.1Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 331 9.1.1Local best quality Teak wood. 332 9.4Providing & fixing panelled or panelled and glazed shutters for doors, windows, clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. 333 9.4.1Local best quality Teak wood. 334 9.4.1.135 mm thick shutters 335 9.27 Providing 40x5 mm. flat iron hold fast 40 cm. i/c fixing to frames with 10 mm. dia. Nuts & wooden plugs and embedding to cement concrete block 30x10x15 cm.1:3:6 (1 cement : 3 course sand : 6 stone agrt. 20 mm. nominal gauge) 336 9.63 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 337 9.63.1300 x 16 mm. 338 9.64 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 339 9.64.2250 x 10 mm. 340 9.64.3150 x 10 mm. 341 9.66 Providing and fixing aluminium handles,ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 342 9.66.1125 mm. 343 9.66.2100 mm. 344 11.27Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 345 11.28Providing and fixing ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. 346 13.412mm cement plaster of mix :- : 347 13.4.11:4 ( 1 cement : 4 coarse sand) 348 13.10 15mm cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall. 349 13.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. 350 13.29.1 New work (two or more coats) over and i/c priming coat with cement primer. 351 13.31 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. 352 13.31.1 Water thinnable cement primer 353 13.33Finishing walls with textured exterior paint of required shade : 354 13.33.1New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 355 13.37 Applying priming coat: 356 13.37.1With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 357 13.36.2Painting wood work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.75 litr/10 sqm of approved brand and manufacture. 358 16.2 Providing and fixing white vitreous china pedestral type watercloset (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 359 16.2.1 W.C. pan with ISI marked white solid plastic seat and lid. 360 16.7 P/F wash basin C.I. brackets, 15mm C.P. brass pillar tape, 32mm C.P. brass waste of standard pattern including painting of fittings and brackets, cutting and making good the walls wherever required. 361 16.7.1 White Viterous China Wash basin size 630x450 mm with a single 15 mm C.P. 362 16.4 P/F white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 363 16.4.4 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern. 364 P/F 110mm P/F UPVC soil, waste, rain water and vent pipes i/c all requisite fittings, joiting of pipes and fittings with solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in charge. 365 (i) 110 mm dia 366 (ii) 75 mm dia 367 P/F PVC traps with 100 mm inlet and 100 mm outlet of self cleaning design with screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors. 368 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 369 17.2.1 1216 (15 mm OD) pipe 370 17.2.2 1620 (25 mm OD) pipe 371 17.29 P/F C.P. brass bib cock of approved quality conforming to IS:8931 : 372 17.29.1 15 mm nominal bore 373 17.32 P/F C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 374 17.32.1 15 mm nominal bore 375 17.28 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, I.S. : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 376 IEI for toilet bloc 377 Wiring for light point/fan point/call bell point with 1.5 sq. mm., FRLS PVC insulated copper conductor single core cable in surface/recessedmedium class PVC conduit with modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 378 (i). Group A 379 (ii). Group B 380 (iii). Group C 381 Wiring for light plug/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mmFRLSPVCinsulatedcopperconductorsingle core cable for loop earthing as required. 382 Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor,single core cable in surface/recessed medium class PVC conduit as required. 383 (ii). 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 384 (iv). 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 385 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin , 5/6 Amps modular socket outlet and 5/6 Amps modular switch , connection etc . as required . 386 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin , 15/16 Amps modular socket outlet and 15/16 Amps modular switch , connection etc . as required . 387 Supply and fixingfollowing way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( But withoy MCB/ RCCB/ Isolator).- 6 way, double door. 388 Supplying and fixing following rating, double pole 240V isolator in the existing MCB DB complete with connection testing and commissioning etc. as reqd. 389 Supplying and fixing 5 amp. to 32 amp. rating 240V/415V, 10KAC curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection, testing and commissioning etc. as reqd. - Single pole. 390 P/F 32A TP & N dis-connector fuse switch unit inside the existing cubicle panel board with ISI marks H.R.C. fuses including drilling holes in thecubicle panel board, makingconnection as reqd. 391 Supplying of 300 mm (900/1200) RPM T. Force 1Pexhaust fan ( Make - Havells-FA06). 392 Installation exhaust fan in the existing opening including making good the damage, connection, testing, commissioning etc. as required. - Upto 450 mm sweep. 393 Supplying of high efficient 9WZiva surface LED down light. (Make Havells -ZIVASURRDDLR9WLED840S). 394 Earthing with Copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. 395 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required. 396 VIII) Sh: Construction of Pump House. 397 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 398 4.1.7 1:5:10 ( 1 Cement: 5 coarse sand: 10 graded stone aggregate cum 40 mm nominal size) 399 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 400 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 401 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). 402 (a) 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 403 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 404 5.20.2Thermo-Mechanically Treated bars 405 5.20 ASteel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 406 5.20 A.2Thermo-Mechanically Treated bars 407 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 408 5.9.6Columns, Pillars, Piers, Abutments, Posts and Struts. 409 5.9.20Lintels, Chajjas, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick. 410 6.1Brick work with common burnt clay F.P.S. (non modular) bricks of class in foundation and plinth in : 411 6.1.1Cement mortar 1:4 (1 cement : 4 coarse sand) 412 6.8 Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: 413 6.8.1. Cement mortar 1 : 3 {1 cement : 3 coarse sand) 414 6.9Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in . 415 6.9.1Cement mortar 1:3 (1 cement : 3 coarse sand) 416 9.1Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 417 9.1.3. Local best quality Tolhao wood. 418 9.6 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. 419 9.6.2. Local best quality Tolhao wood. 420 9.6.2.2. 30 mm thick 421 9.27 Providing 40x5 mm. flat iron hold fast 40 cm. i/c fixing to frames with 10 mm. dia. Nuts & wooden plugs and embedding to cement concrete block 30x10x15 cm.1:3:6 (1 cement : 3 course sand : 6 stone agrt. 20 mm. nominal gauge) 422 9.64 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 423 9.64.3150 x 10 mm. 424 9.66 Providing and fixing aluminium handles,ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 425 9.66.2100 mm. 426 13.412mm cement plaster of mix :- 427 13.4.11:4 ( 1 cement : 4 coarse sand) 428 13.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. 429 13.29.1 New work (two or more coats) over and i/c priming coat with cement primer. 430 13.37 Applying priming coat: 431 13.37.1With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 432 13.36.2Painting wood work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.75 litr/10 sqm of approved brand and manufacture. 433 11.4 62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1 :2(1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed@ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry.but excluding the cost of nosing of steps etc. complete. 434 10.16 Steel work in built up tubular (round, square or recta ngular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. 435 10.16.3. Electric resistance or induction butt welded tubes. 436 10.6 Suppling and fixing rolling shutters of approved make ofrequired size M.S. laths interlocket together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guidesand arrangements for inside and ouside locking with push and pull operation completeincluding the cost of providing and fixing necessary 27.5 cm long wire springs grade No. 2 and M.S. top cover of required thickness for rolling shutter. 437 10.6.1. 80x1.25mm M.S. laths with 1.25 mm thick top cover 438 10.7 Providing and fixing ball bearing for rolling shutters 439 12.46 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with 440 12.46.1. Precoated galvanised iron profile sheets 0.35 mm thick 441 12.47 Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : 442 12.47 .1.1 . Precoated galvanised iron profile sheets 0.35 mm thick 443 13.36.3Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.80 litr/10 sqm of approved brand and manufacture. 444 IEI for pump house 445 Wiring for light point/fan point/call bell point with 1.5 sq. mm., FRLS PVC insulated copper conductor single core cable in surface/recessedmedium class PVC conduit with modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 446 (ii). Group B 447 (iii). Group C 448 Wiring for light plug/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mmFRLSPVCinsulatedcopperconductorsingle core cable for loop earthing as required. 449 Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor,single core cable in surface/recessed medium class PVC conduit as required. 450 (ii). 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 451 (iv). 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 452 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin , 5/6 Amps modular socket outlet and 5/6 Amps modular switch , connection etc . as required . 453 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin , 15/16 Amps modular socket outlet and 15/16 Amps modular switch , connection etc . as required . 454 Supply and fixingfollowing way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( But withoy MCB/ RCCB/ Isolator).- 6 way, double door. 455 Supplying and fixing following rating, double pole 240V isolator in the existing MCB DB complete with connection testing and commissioning etc. as reqd. 456 Supplying and fixing 5 amp. to 32 amp. rating 240V/415V, 10KAC curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection, testing and commissioning etc. as reqd. - Single pole. 457 P/F 32A TP & N dis-connector fuse switch unit inside the existing cubicle panel board with ISI marks H.R.C. fuses including drilling holes in thecubicle panel board, makingconnection as reqd. 458 Supplying of 300 mm (900/1200) RPM T. Force 1Pexhaust fan ( Make - Havells-FA06). 459 Installation exhaust fan in the existing opening including making good the damage, connection, testing, commissioning etc. as required. - Upto 450 mm sweep. 460 Supplying of high efficient 9WZiva surface LED down light. (Make Havells -ZIVASURRDDLR9WLED840S). 461 Supplying of 10W LED Hexa IP66 bulkhead. (Make - Havells - Ziva surface down light. ( Make Havells -HEXAFT10WLED857SSYMBOPC). 462 Earthing with Copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. 463 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required. 464 IX)Electrical Works 465 SITC of 250 KVA, 11/0.433 KV, 3Phase, 50 Hz, Dyn-11, Oil cooled, copper wound outdoor type Distribution Transformer with LV Site cable box and first filling of oil along with standard fittings conforming to IS:1180 2014 (Part-I):, Level-I (Amendment - 4). 466 Supplying & Fixing of LT cubical panel board made from 2.0 mm thick CRCA MS sheet of not less than 1000 mm deep duly dust and vermin proof totally enclosed free floor standing i/c P/F 400 ampere aluminium busbar for distribution system 3 phase, 4 wire 415 volt,50 c/s A.C. Supply i/c earth strips complete in all respects i/c painting with synthetic enamelled paint connection, interconnection so as to make the panel complete etc as reqd. i/c P/F of following electrical switch gears in the existing cubical panel board with suitable size of thimbles, ferrules etc. as reqd. 467 Incomer. 468 a)50 KA, 400 A, Four Pole ACB EDO Type with O/L, S/C& G/F protection – 2 Nos. 469 b) Multifunction Meter with selector switch & protection MCB’s – 04 Nos. 470 c) LEDIndicatinglightforincomerACB’s 471 d) 6 A, SPMCB – 5 No. 472 Outgoing 473 a) 35/36KA, 200 A, TPN MCCB (thermo magnatec)– 1No. 474 b) 25 KA,160 A, TPN MCCB (thermo magnatec) – 2 No. 475 c)25 KA, 100 A, TPN MCCB (thermo magnatec) – 1No 476 d)25 KA, 63 A, TPN MCCB (thermo magnatec) – 2 No. 477 Supplying, Installation, Testing and Commissioning of Contactor switching auto manual power factor correction panel of 90 KVAR capacity, 8 stages on auto having self -healing APP type capacitors ISI marked three phase mounted in individual feeders. In the incoming feeder, the panel will have 8 step microprocessor-based power factor relay with digital PF display and auto manual switching facility. The panel will be provided with a main incomer TP MCCB of 250 Ampere (microprocessor based) 35 KA, ON & OFF indication lamp be provided in each feeder for ON & OFF indication of capacitors. Forced cooling should be provided for individual Thyristor module. Thyristors should be rated 415V. Digital ammeter & voltmeter with inbuilt selector switch & protection should be provided. CT’s & copper bus bar of suitable rating should be designed & incorporated i/c providing the accessories complete as required. (As per detail & specification enclosed). 478 Supply of following sizeXLPE insulated, cores laid up. PVC inner sheathed Aluminium armoured cable 1.1KV grade. - 3.5 x 185 sqmm Al. amoured cable. 479 Supply of following sizeXLPE insulated, cores laid up. PVC inner sheathed Aluminium armoured cable 1.1KV grade. - 3C x 120 sqmm 480 Supply of following sizeXLPE insulated, cores laid up. PVC inner sheathed Aluminium armoured cable 1.1KV grade. - 4 C x 16 sqmm 481 Supply of following sizeXLPE insulated, cores laid up. PVC inner sheathed Aluminium armoured cable 1.1KV grade. - 2C x 10 sqmm 482 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required (i). 100 mm dia 483 Providing 46-50mm dia. DWC HDPE pipe for cable laying between pole to pole/pole to Distribution box/Distribution box to source. 484 Layingof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (i). Above 95sqmm to upto 185 sq.mm 485 Layingof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (i). Upto 35 sq.mm 486 Supplying and fixing 16 sqmm thimble. 487 Supplying and fixing 10 sqmm thimble. 488 Supplying and making outdoor cable end termination with heat shrinkable joining kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminiumconductor cable of 11 kV grads as required. 489 (i).120 sq. mm 490 Supplying and making straight through joint with cast resin compound including ferrulesand other joining materials for following size of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 kV grads as required. 491 (i).3.5 x 185 sq. mm 492 P/L (0.45x0.45x0.90)+(0.90x0.90x0.90)cum type muffing for errection of upto 9 mtr. Long pole embaded in 1:3:6 ( 1 cement :3 c/sand : 6 stone aggt. of 40mm nominal gause i/c centering & shuttering the earth work etc. as reqd. 493 Providing & errection of 1m single arm bracket, 6M HDG octagonal pole with 70x130 top & bottom dia, 3mm thick sheet with foundation bolt (set of 4) i/c foundation etc. as reqd 494 Supply and fixing of 100W LED street light made up of pressure die-cast aluminium housing with high efficiency LED as lighting i/c connection ecte. as required. (ENDURA SUNDOW NSL 100W LED 765PASYBOPV- Havells). 495 Supply & drawing 2 x2.5 mm of FR PVC insulated copper single core cable in existing surface / recessed steel / PVC conduit as reqd. 496 P/F 5 amp. to 32 amp. rating 230V B series MCB for lighting and other load of single pole in the existing MCB DB complete with connection testing and commissioning etc. as reqd. 497 Providing & fixing of earthing for each street light pole shall be provided with double coil earthing using 8 SWG G.I wire wound to 50mm diameter earth electrode and shall be connected to Earthing stud of pole. The earth electrode shall be buried upto a depth of 1 M below the ground level. 498 Fabrication, Supplying, Installation, Testing & Commissioning of floor mounted front openable outdoor cubical panel board made from 2.0 mm thick CRCA sheet of 300 mm deep, duly dust and vermin proof totally enclosed free standing / floor including providing & fixing of 125 ampere aluminum busbar for distribution system 3 phase, 4 wire 415 volt, 50Hz, A.C. Supply, i/c earth connections complete in all respects i/cpainting with synthetic enamelled paint etc as required withthe following accessories with inter connectionsetc completeas reqd. (Size 1.0 Sq. Mtr. Approximately) (a) 125 Amps. 16 KA TP MCCB – 01 No. (b) TPN MCB 63 Amps.- 3 Nos. (c) DP MCB – 12 Nos. (d) ML-2 Contactor – 1 No.{Make: L&T } (e) Electronic Timer-2 Nos. {Make: L&T } (f) Digital volt meter (0-500 V) with selector switch- 1 set (g) LED indication lamps with 2 Amps. SP MCB– 03Nos. (h) Digital Amp. Meter (0-500A) with selector switch and CTs set – 1 set 499 Earthing with Copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. 500 Providing and fixing25mm X 5mm copper strip on surface or in recess for connections etc. as required. 501 X) Sh : Construction of Inspection Shed and Administrative block 502 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 503 2.8.1 All kinds of soil. 504 2.24 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 505 2.26Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete. 506 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level : 507 4.1.61:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 508 4.15 Making plinth protection 50 mm. in c.c. 1:3:6 (1 cement : 3 course sand : 6 graded stone aggrt. 20 mm. nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finished the top smooth. 509 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 510 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 511 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 512 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 513 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). 514 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 515 5.20.2Thermo-Mechanically Treated bars 516 5.20 ASteel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 517 5.20 A.2Thermo-Mechanically Treated bars 518 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 519 (a) 5.9.1Foundations, footings, bases of columns etc. and mass concrete. 520 (b) 5.9.6Columns, Pillars, Piers, Abutments, Posts and Struts. 521 (c) 5.9.7Stairs, (excluding landings) except spiral-staircases. 522 (d) 5.9.15Edges of slab and breaks in floors and walls.Under 20 cm wide. 523 (e) 5.9.18. Weather shade, Chajjas, corbels etc., including edges. 524 (f) 5.9.19Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick. 525 (g) 5.9.20Lintels, Chajjas, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick. 526 5.33 Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used. 527 5.33.1. 450 mm dia. Piles 528 6.1Brick work with common burnt clay F.P.S. (non modular) bricks of class in foundation and plinth in : 529 6.1.1Cement mortar 1:4 (1 cement : 4 coarse sand) 530 6.9Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in . 531 6.9.1Cement mortar 1:3 (1 cement : 3 coarse sand) 532 9.26 Providing 40x5 mm. flat iron hold fast 40 cm. i/c fixing to frames with 10 mm. dia. Nuts & wooden plugs and embedding to cement concrete block 30x10x15 cm.1:3:6 (1 cement : 3 course sand : 6 stone agrt. 20 mm. nominal gauge) 533 9.62 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 534 9.62.1300 x 16 mm. 535 9.63 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 536 (a) 9.63.2250 x 10 mm. 537 (b) 9.63.3150 x 10 mm. 538 9.65 Providing and fixing aluminium handles,ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 539 (a) 9.65.1125 mm. 540 (b) 9.66.2100 mm. 541 10.6 Suppling and fixing rolling shutters of approved make ofrequired size M.S. laths interlocket together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guidesand arrangements for inside and ouside locking with push and pull operation completeincluding the cost of providing and fixing necessary 27.5 cm long wire springs grade No. 2 and M.S. top cover of required thickness for rolling shutter. 542 10.6.1. 80x1.25mm M.S. laths with 1.25 mm thick top cover 543 10.7 Providing and fixing ball bearing for rolling shutters 544 10.8 Extra for providing mechanical device chain and crank operation for operating rolling shutters. 545 10.8.2 Exceeding 16.80 sqm in area. 546 10.16 Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc complete. 547 10.16.3. Electric resistance or induction butt welded tubes. 548 10.19 Providing and fixing bolts including nuts and washers complete. 549 11.27Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 550 11.28Providing and fixing ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.. 551 11.33Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut wlth the zero chipping diamond cutter only. Laying of tiles will be done with the notch towel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily. 552 11.33.1Double charge vitrified tile polished finish of size 553 11.33.1.1Size of Tile 600x600 mm 554 11.36 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer),with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry@ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 555 11.36.2 Size of Tile 600x600 mm 556 12.37 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i)Single socketed pipeste. 557 12.37.1. 75 mm diameter 558 12.46 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with . 559 12.46.3. Precoated galvanised iron profile sheets 0.50 mm thick 560 12.47 Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : 561 12.47.1. Ridges plain (500 - 600mm). 562 12.47.6. Gutter (600 mm over all girth). 563 13.1 12mm cement plaster of mix :- 564 13.1.11:4 ( 1 cement : 4 coarse sand) 565 13.320 mm cement plaster of mix :- 566 13.3.11:4 ( 1 cement : 4 coarse sand) 567 13.9 Cement plaster 1:3 (1 cement: 3 coarse sand} finished with a floating coat of neat cement. 568 13.9.2. 20 mm cement plaster. 569 13.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. 570 13.29.1 New work (two or more coats) over and i/c priming coat with cement primer. 571 13.31 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. 572 13.31.1 Water thinnable cement primer 573 13.33Finishing walls with textured exterior paint of required shade : 574 13.33.1New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 575 13.36.3Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.80 litr/10 sqm of approved brand and manufacture. 576 13.37 Applying priming coat: 577 13.37.2. With ready mixed aluminium primer of approved brand and manufacture or resinous wood and plywood. 578 13.46 Painting with aluminium paint of approved brand and manufacture to give an even shade: 579 13.46.1. Two or more coats on new work 580 13.58Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 581 15.2 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 582 18.1 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cteatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-incharge.(Glazing and panelling to be paid for separately): 583 18.1.1 For fixed portion. 584 18.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 585 18.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): 586 18.3.1 With float glass panes of 5.50 mm thickness 587 Water Supply & Sanitary Installation : 588 16.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.1. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 589 16.3.1 W.C. pan with ISI marked white solid plastic seat and lid. 590 16.4 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x41 0x265 mm sizes respectively with utomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 591 16.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern 592 16.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 593 16.5.1 Single half stall urinal with 5 litre P. V.C. automatic flushing cistern 594 16.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G. I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : 595 16.6.1 Single half stall urinal with 5 litre P. V.C. automatic flushing cistern 596 16.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 597 16.7A.1 (a) White Viterous China Wash basin size 550x400 mm with a15 mm C.P brass. 598 16.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 599 16.13 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 600 16.19 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 601 16.26 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 602 16.26.1.2 40 mm dia 603 16.28 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing 604 16.28.2 Rectangular shape 453x357 mm 605 16.29 Providing and fixing toilet paper holder: 606 16.29.2. Vitreous china 607 16.31 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 608 16.31.1 Waste coupling 31 mm dia of 79 mm length and 62mm breadth each weighing not less than 45 gms 609 16.32 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 610 16.33 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 611 16.35 Providing and fixing PTMT urinal cock of approved quality and colour. 612 16.35.1 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms. 613 17.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 614 17.1.5 40 mm nominal outer dia Pipes 615 17.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall etc. 616 17.2.2 20 mm nominal outer dia Pipes 617 17.2.3 25 mm nominal outer dia Pipes 618 17.2.4 32 mm nominal outer dia Pipes 619 17.13 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 620 17.13.2. 150 mm diameter 621 17.23 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking litre arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 622 17.24 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 623 17.24.1. 15 mm nominal bore 624 17.27 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 625 17.27.1. 15 mm nominal bore 626 17.28 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 627 17.28.1. 15 mm nominal bore 628 17.29 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 629 17.37 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms 630 17.43 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 631 17.43.2 15 mm nominal bore with 45 cm length 632 17.46 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 633 Providing and fixing 75 mm UPVC soil, rain water and vent pipe i/c requisite filling, jointing of pipes & fitting with solvent cement, trenching, refilling & testing of jointscomplete as per direction of Engineer in charge. 634 Waste pipe 75mm dia 635 Providing and fixing 110 mm UPVC soil, rain water and vent pipe i/c requisite filling, jointing of pipes & fitting with solvent cement, trenching, refilling & testing of jointscomplete as per direction of Engineer in charge.e. 636 110mm dia for Toilet 637 Providing and fixing SWR Nahani traps with 100 mm inlet and 75 mm out of self cleaning design with screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors. 638 External SWR connection : 639 2.10 Excavating trenches of required width for pipes, cables, etc including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 640 2.10.1 All kinds of soil. 641 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - -All work upto plinth level: 642 4.1.6 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 643 17.17 Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1 :4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1 :2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1 :5:1 0 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 :3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 644 17.17.1 With 1st class common burnt clay F.P.S. (non-modular) bricks 645 17.41 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 646 17.41.5. 300 mm dia Ductile Iron Class K-7 pipes 647 Septic tank : 648 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 649 2.8.1 All kinds of soil. 650 2.23 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 651 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - -All work upto plinth level: 652 4.1.6 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 653 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 654 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 655 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 656 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 657 5.3Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). 658 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 659 5.20.2Thermo-Mechanically Treated bars 660 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 661 (a) 5.9.1Foundations, footings, bases of columns etc. and mass concrete. 662 (b) 5.9.2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 663 (c) 5.9.19Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick. 664 (d) 5.9.15Edges of slab and breaks in floors and walls.Under 20 cm wide. 665 13.9 Cement plaster 1:3 (1 cement: 3 coarse sand} finished with a floating coat of neat cement. 666 13.9.2. 20 mm cement plaster. 667 19.32Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 668 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 669 XI) Sh: Construction of Storm Water Drain. 670 A - CONSTRUCTION OF DRAINS: 671 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 672 2.8.1 All kinds of soil. 673 2.23 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 674 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 675 4.1.61:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 676 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 677 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 678 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 679 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 680 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 681 5.20.2Thermo-Mechanically Treated bars 682 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : l 683 (a)5.9.1Foundations, footings, bases of columns etc. and mass concrete. 684 (b)5.9.2 Walls (any thickness ) including attached pilasters, buttresses, plinth and the string courses etc. 685 XII) Sh: Construction of Parking. 686 2.6Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth1.5 m in width as well as 10 sqm on plan) includinggetting out and disposal of excavated earth,lead upto 50 m and lift upto 1.5m, as directed by the Engineer in charge. 687 2.8.1 All kinds of soil. 688 Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications A Stone/Boulder 689 Providing, laying and compacting Granular Base/Sub-base with naturally occurring Sand Gravel Material free from organic ore other deleterious constituent spreading with Motor Grader and compacted by rolling with power roller of 8 to 10 tonne capacity in layers not exceeding 150mm (spread thickness). 690 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level : 691 4.1.21:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 692 11.37Providing and laying factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Enginneer-in-charge. 693 11.37.2 80mm thick 694 XII) Sh: Construction of underground sump. 695 2.8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 696 2.8.1 All kinds of soil. 697 2.23 Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m 698 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 699 (a)4.1.61:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 700 (b)4.1.21:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 701 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 702 5.1.1 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 703 5.2Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: 704 5.2.11:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 705 5.3Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). 706 5.20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelt: 707 5.20.2Thermo-Mechanically Treated bars 708 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 709 (a)5.9.1Foundations, footings, bases of columns etc. and mass concrete. 710 (b)5.9.2 Walls (any thickness ) including attached pilasters, buttresses, plinth and the string courses etc. 711 (c)5.9.3 Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick 712 13.10 15mm cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall. 713 XIII) Sh : Construction of viewing platform. 714 10.16 Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. 715 10.16.3. Electric resistance or induction butt welded tubes. 716 10.19 Providing and fixing bolts including nuts and washers complete. 717 10.24 Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. 718 10.24.1. In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete. 719 13.36.3Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litr/10 sqm over an under coat of primer @ 0.80 litr/10 sqm of approved brand and manufacture. 720 XIV)Sh: Horticulture works. 721 2.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be levelledand neatly dressed: 722 2.1.1 All kinds of soil 723 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measureed in stacks will be reduced by 20% for payment) 724 10.11 (vol ii)Supply at Site Well Decayed Farm Yard Manure (Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking) 725 10.12 (vol ii)Supplying Sludge (Supply at site of work/store-deoiled neem cake duly packed in used gunny bags) 726 Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer in charge 727 10.1 (vol ii )Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately). 728 10.2.2 (vol ii) Grassing with Doobs Grass (Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed) 729 (a) In rows 15 cm apart in either direction 730 10.14 (vol ii)Edging with 2nd class Bricks, laid dry lengthwise (Edging with 2nd class bricks, laid dry lengthwise, including excavation, refilling, consolidation, with a hand packing and spreading nearly surplus earth within a lead of 50 meters) 731 10.9 (vol ii)Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfitling the trench, watering, fixing the tree guard and maintaining the plants for one year) 732 Planting Flowering Plants and Shrubs in Central Verge 733 XV) Sh: Internal Electrical Works. 734 Wiring for light point/fan point/call bell point with 1.5 sq. mm., FRLS PVC insulated copper conductor single core cable in surface/recessedmedium class PVC conduit with modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 735 (i). Group A 736 (ii). Group B 737 (iii). Group C 738 Wiring for light plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mmFRLSPVCinsulatedcopperconductorsingle core cable for loop earthing as required. 739 Wiring for power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mmFRLSPVCinsulatedcopperconductorsingle core cable for loop earthing as required. 740 Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor,single core cable in surface/recessed medium class PVC conduit as required. 741 (i). 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 742 (ii). 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 743 (iii). 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 744 (iv). 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 745 (v). 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 746 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin , 5/6 Amps modular socket outlet and 5/6 Amps modular switch , connection etc . as required . 747 Supply and fixing suitable sizeGI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin , 15/16 Amps modular socket outlet and 15/16 Amps modular switch , connection etc . as required . 748 Supplying and fixing 30 A, 415V, TPN industrial type socket outlet with 4 pole and earth, metal enclosured plug top alongwith 30 A C curve, TPMCB, in sheet steel enclosure, on surface or recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as reqd. 749 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box i/c connections but excluding modular plate etc. as required. 750 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 751 Supplying of 300 mm (900/1200) RPM T. Force 1Pexhaust fan ( Make - Havells-FA06). 752 Installation exhaust fan in the existing opening including making good the damage, connection, testing, commissioning etc. as required. - Upto 450 mm sweep. 753 Supplying and fixing brass batten/ angle holder including connection etc. as required. 754 Supplying and fixing 9W LED Bulb. 755 Supplying of high efficient 9WZiva surface LED down light. (Make Havells -ZIVASURRDDLR9WLED840S). 756 Supplying of 10W LED Hexa IP66 bulkhead. (Make - Havells - Ziva surface down light. ( Make Havells -HEXAFT10WLED857SSYMBOPC). 757 Supplying and Fixing of 80W LED robust highbay with PDC housing suitable for ceiling (Surface/Suspendended) mounting with sustem efficacy upto 150lm/W i/c connection etc as reqd. (Havells-SAUCERGENXHBP80WLED757P90DBOLTG) 758 SITC of floor mounted Double Door Outdoor Type Conforming to IP 55 protection, 3 phase, 400 Amps, 440 Volts, 50 Hz, to withstandrough usage and weather, fabrication with 16 SWG CRCA sheet with hinged type doors, detachable gland plates at top for cable chamber, earthing studs, bottom cable entry provision, including supplying and fixing the following switchgear, interlocking between incomer and bus coupler, interconnections with bus bar, internal control wiring, earthing etc. complete as required and as per technical specifications. 759 a)INCOMING: 760 (i)250A, 4 pole 36KA, MCCB with Thermal and Magnetic release with spreader link and rotary handle - 2 nos for 2 incomers. 761 (ii)Bus Bar - TPN Aluminium Main Horizontal Bus Bar of 400 Amps for each phase and neutral. 762 (iii)Interlocking arrangement for 2 incomers and 1 bus coupler. 763 (iv)Multifunction Meter - 2 nos 2 incomers. 764 (v)C.T. Resin cast, 250/5 Amps, 15 VA, Class 1 765 (vi)LED type indicating lamps (Red Yellow Blue) with control MCB = 2 set. 766 (vii)LED type indicating lamps (ON & OFF) with control MCB = 2 set. 767 b)BUS COUPLER: 768 (i)250A, 4 pole 36KA, MCCBwith Thermal and Magnetic release with spreader link and rotary handle - 1 No. 769 (ii)LED type indicating lamps (ON & OFF) with control MCB = 1 Set. 770 c)OUTGOING 771 (i)63A, 4 pole 30KA, MCCB with Thermal and Magnetic Release with spreader link and rotary handle - 6 nos. 772 (ii)LED type indicating lamps (ON & OFF) with control MCB = 06 set. 773 (iii)32A TP MCB (C Curve) - 8 nos. 774 (iv)Interconnetion with Aluminium BusBar. 775 Supply of following sizeXLPE insulated, cores laid up. PVC inner sheathed Aluminium armoured cable 1.1KV grade. 776 (i). 4 C x 95qmm 777 Layingof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 778 (ii). Above 95 sqmm and upto185 sqmm 779 Supplying and making indoor end termination with brass compression gland and Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 780 (iii). 3.5 C x 95 Sqmm 781 Earthing with GI earth pipe 4.5 metre long , 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke & salt as required. 782 Providing and fixing25mm X 5mm GI strip on surface or in recess for connections etc. as required. 783 Earthing with Copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. 784 Providing and fixing25mm X 5mm copper strip on surface or in recess for connections etc. as required. 785 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. 786 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required. 787 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For horizontal run) 788 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) 789 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required 790 (i). 150 mm dia 791 Supplying and fixing cable route marker with 10 cm X 10 cm X 5mm thick G.I. plate with LT inscription there on, bolted /welded to 35mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. 792 XVI) Sh: Fire Fighting Works. 793 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 794 e) 80 mm dia 795 g) 150 mm dia 796 h) 200 mm dia 797 Supplying and fixing single headed external Yard hydrant valve with1 No. 63 mm dia instantaneous FM Gunmetal coupling and cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal cap and chain as required. - Single headed Stailless steel. 798 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :GUN Metal 799 Supply and fixing standard short suzeBranch pipe withnozzle 16mm dia (SS). Outlet with standard instantaneous type 63mm dia coupling. (ISI) 800 Supply and fixing Hose cabinet 450 (W) x 450 (D). 250(H)( SINGLE DOOR) as per sample approval by theconsultant. The construction of the cabinet be in Sheet with red colour powder coating. 801 Supply and fixing Hose cabinet 900 (W) x 750 (D) 250(H)( DOUBLE DOOR) as per sample approval by theconsultant The construction of the cabinet be in sheet with red colour powder coating. 802 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 803 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 804 20 mm nominal internal dia gun metal globe valve & nozzle. 805 Drum and brackets for fixing the equipmets on wall. 806 Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 807 30 M 808 Supply and fixingball valve (full boro type ) plastic coated lever and screwed female ends tested to 20 kg/cm2 of approved quality as specified. 809 a) 25mm dia 810 b) 15mm dia 811 Supply and fixing gunmetal single acting Air Release valve with screwed inlet 25mm dia. 812 Supply and fixing of fire bridge connection of connection of cast iron body with gun metal male instantaneous inlet couplings complete with capand chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required. - 2 way- 100mm dia M.S pipe. 813 Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydant station. a)Dial Diameter 100mm calibration 0-15 kg/sq.cm 814 Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydant station. 815 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as reqd. 816 a) 150 mm dia 817 b) 100 mm dia 818 c) 80 mm dia 819 Supplying, fixing, testing and commissioning of butterfly valveof PN 1.6 rating with bronze/gunmetal seat dulyISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 820 b) 65 mm dia 821 c) 80 mm dia 822 d) 100 mm dia 823 e) 150 mm dia 824 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. - 150mm dia. 825 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : 826 Horizontal type, multistage, centrifugal, split casing pump of cast iron body& bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. 827 Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. 828 M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. 829 Suitable cement concrete foundation duly plastered with anti vibration pads. 830 2280 lpm at 70 m Head 831 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump). 832 Horizontal type, multistage, centrifugal pump of cast iron bodyand bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. 833 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. 834 M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 835 180 lpm at 70 m Head 836 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 837 Incoming 838 250A, 50kA4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of CopperBus Bar 300A 839 Outgoing 840 ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) 841 Main Fire Pump 842 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 843 Jockey Pump 844 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 845 Diesel Engine Control 846 Control for diesel engine comprising Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode 847 Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication 848 Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 020 A DC Ammeter 849 All standard relays and accessories for automatic operation of diesel engine 850 System Controller 851 Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification. 852 Supply ofCO2 type 4.5kg capacity Portable Fire Extinguishers assembled from brand new explosives approved cylinders, complete with screw-down type valve, internal discharge tube, one meter high pressure rayon braided hose, discharge horn and bearing ISI mark IS:3224. CO2 gas as per IS: 15222, Internal discharge tube IS: 738, Discharge duration 10-18 secs. Filled weight of extinguisher shall be 17 Kgs and tested to 250 kgf /sq.cm. 853 Supply of ABC type stored pressure Fire extinguisher, fabricated from MS tubes, fitted with brass forged squeeze grip valve assembly incorporated with pressure gauge, bearing IS: 1384 with initial charge of following capacity. ABC powder (MAP 50%) and pressurized with nitrogen gas. M.S. Body as per IS : 513 forged brass valve as per IS : 6912, Tested to 30Kgf/sq.cm. - 4kg Capacity

Key Value

Document Fees
INR 5000 /-
EMD
INR 2810700.0 /-
Tender Value
INR 14.05 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail