Tender For Various Works In Iti Bathinda Distt. Bathinda; 2 Paint & renovation 3 Scraping Of Colour Wash and White Wash 4 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 5 Wall paintingwith plastic emulsion paint of approvedbrandandmanufacturer togivean even shade (two or more coats 6 Painting two or more coats with syntheticenamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. 7 Scraping of cement plaster 8 Cement plaster 12.5 mm thick 1:4 9 Removing Doors and Windows (Steel or wood)with chowkhats by making recesses in wallswhen the wall is not to be dismantled 10 Crdit Of Old doors 11 Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standarddesign latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notchprovision for receiving tower bolts and finished,fixed in position including the cost of cementconcrete 1:3:6 for filling in the frame and cementconcrete 1:2:4 for lugs complete to thesatisfaction of Engineer-in-charge.(B)Door and window frame of size 113mmx60mmxwith 35mm wide single rebate 12 Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standarddesign latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cementconcrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. (c)Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter 13 Factory manufactured solid flush doorfixed in position iron hinges, etc(excluding the cost of any fittings otherthan specified above but includinglabour for fixing the same in positionCode: IS 2202-1 (1999):35 mm thick 14 Wire gauge Hollock wood door shutterwithout springs housed in chowkhat. (A)35 mm thick 15 Renewing glass panes with wooden filletswherever necessary (b) Glass panes weighing 10.75 Kg/sqm 16 Preparation of plywood surface for paintingincluding sand papering the surface andapplying filling with approved quality fillersconsisting of white lead, linseed oil, Varnish,and Chalk Mitti including finishing the surfaceto required finish complete. 17 Applying pink primer or aluminum primingcoat on wood work including preparation ofsurface knotting and stopping etc. 18 Painting two or more coats excluding primingcoat with synthetic enamel paint in all shadeson wood work, metallic or plastered, concretesurface to give an even shade. 19 Providing and fixing aluminum sliding doorbolts ISI marked anodized (anodic coatingnot less than grade AC 10 as per IS :1868) transparent or dyed to requiredcolour or shade with nuts and screws etc.complete 300mm x 16mm 20 Providing and fixing hydraulic door closerISI mark with necessary screw etc.complete I.S.I Designation No. III (size ofdoor 851mm to 1000mm) 21 Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppersandscrewetc. for these fittings (Excluding sliding bolt) 22 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : 23 For fixed portion and chawkhats 24 For Opnablle work 25 Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. 26 Providing and fixing 12mm thickprelaminated particle board flat pressedthree layer or graded wood particle boardconforming to IS: 12823 Grade l Type ll, inpaneling fixed in aluminum doors,windows shutters and partition frames withC.P. brass / stainless steel screws etc.complete as per architectural drawingsand directions of Engineer-In-Charge. Prelaminatedparticle board with decorativelamination on Both side 27 Providingand fixingglazing inaluminum door, window, ventilator shutters and partitions etc. withPVCPlug/ neoprene gasket etc. complete as per the architectural drawingsand thedirections ofengineer-in-charge. (Costofaluminum snap beading shall be paid in basic item) 28 Dismantling cement conglomerate floors 25mmto 50mm thick including concrete base. 29 Base course of floor consisting of 100mm thickcement concrete 1:8:16 and 100mm sand fillingusing mechanical mixer for mixing of material 30 Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) 31 Grouting the joints of flooring tiles having joints of3 mm width, using 2mm to 3 mm gap usingspacers and later this gap to be filled withcement based grout ) with Cement base groutand matching pigments etc., complete, includingfilling / grouting and finishing complete as perdirection of Engineer-in-charge.a Size 600x600 mm. 32 Deduct for not using 20mm thick cement mortar1:4 (1 cement : 4 fine sand ) bedding in laying offloor tiles. 33 Fixing glazed/ Ceramic/ Vitrified floor tiles withcement based high polymer modified quick-settile adhesive (Water based) conforming to IS:15477, in average 3mm thickness. 34 Regrading terracing of mud plastercovered with tiles or bricks in cement bydismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacingunserviceable tiles, or bricks with newover and disposal of unserviceablematerial to the dumping ground within 50m lead (The cost of new tiles or bricksexcluded) 35 Washing concrete surface scrubbing withbrushes including preparing and laying slurry Labour Rate Only 36 Nicking cement concrete surface (over 28days old including preparation and layingslurry 37 Providing and laying four courses of water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown type bitumen grade 85/25 applied hot at 1.20 Kg. Per sqm of area for each course second course on roofing felt type 3grade-1 (Hession base self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or peasizes grit spread at 0.006cum per Sqm including preparation of surface complete. 38 Cost Of New Tiles 39 Stripping and stacking slate or tiles of a roof. 40 Dismantling brick work tile, masonry or tilelining 41 Credit Of Tiles 42 Credit Of Bricks 43 Credit Of Brick Bats 44 Credit Of Tiles Bats 45 Loading +Unloading + Carriage Of Disposable Material upto 1km 46 Dismantling concrete Reinforced cement concrete 47 Credit of old steel 48 First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. 49 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 50 Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels 51 Reinforced cement concrete M-25mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. 52 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate ofRCC including bending and binding placing in position complete 53 Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing 54 Cement concrete 1:2:4 gola 10cm x 10cmconcave quadrant along junction of roofs withparapet wall finished smooth, where speciallyspecified. 55 Providing and fixing on wall face unplasticisedRigid PVC rain water pipes single socketed(working pressure 4 kgf / cm²) conforming to IS :4985, including fixing with MS clamps. U-PVC pipes (working pressure 4 kgf. / sqcm)pipe 110 mm dia. 56 Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm 57 Bottom khurra on ground 1.2m 0.6m consisting ofbricks on edge laid in cement mortar 1:3 over 7.5cm cement concret 1:8:16 including 12.5mm thickcement plaster 1:3 58 Top Khurra 0.6mx0.6m for rain water pipe in25mm thick cement concrete 1:2:4 over 50.00thick cement concrete 1:8:16 59 Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. 60 Providingand fixing1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approvedmake in all colours, shadesexcept burgundy, bottlegreen, blackof size450x310mmasapprovedbyEngineer-in Chargeinskirting, risersofstepsanddadosover 12mmthickbedofcementMortar1:4(1cement: 4 finesand)andjointingwithgreycementslurry @3.3kg per sqm including pointing in white cementmixedwithpigment ofmatchingshade complete. 61 Providing and fixing mineral fibre false ceiling tiles at allheight upto 4 mtr.of size 595X595mm of approved texture, designand pattern. The tiles should have Humidity Resistance(RH) of 99%, Light Reflection > 85%, ThermalConductivity k = 0.052 - 0.057 w/m K, Fire Performanceas per (BS 476 pt - 6 &7)in true horizontal levelsuspended on interlocking T-Grid of hot dipped all roundgalvanized iron section of 0.33 mm thick (galvanized@120 gsm) comprising of main T runners of 15x32 mmof length 3000 mm, cross T of size 15x32mm of length1200 mm and secondary intermediate cross T of size15x32 mm of length 600 mm to form grid module of size600x600 mm suspended from ceiling using galvanizedmild steel item (galvanised@80gsm) 50 mm long 8mmouter diameter M-6 dash fasteners, 6 mm diameter fullythreaded hanger rod up to 1000 mm length and L-shapelevel adjuster of size 85x25x2 mm, spaced at 1200 mmcentre to centre along main ‘T’. The system should reston periphery walls /partitions with the help of GIperimeter wall angle of size24x24X3000 mm made of0.40 mm thick sheet, to be fixed to the wall with help ofplastic rawl plug at 450 mm centre to centre & 40 mmlong dry wall S.S. screws. The exposed bottom portionof all T-sections used in false ceiling support systemshall be pre-painted with polyester baked paint, for allheights. The work shall be carried out as perspecifications, drawings and as per directions of theengineer-in-charge (i)With 16 mm thick beveled tegular mineralfibre false ceiling tile (NRC 0.55 to 0.6)size 595x595 mm 62 Work shop sheds 63 Stripping and stacking iron sheets of a roofincluding ridging, flashing, eaves boards guttersand down pipes. 64 Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25%-40%. should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 65 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 66 Providing and fixing thermal insulation ofceiling (under deck insulation) with ResinBonded Rockloyd Rockwool (NonCombustible Grade) conforming to IS: 8183and density 48 kg/ m3, wrapped in 200 GVirgin Polythene bags fixed to ceiling withmetallic cleats (50x50x3 mm) @ 60 cm andwire mesh of 12.5mm x 24gauge wire mesh,for top most ceiling of building and allcomplete as per engineer in charge (B)50 mm thick Resin bonded Rock wool 67 Providing and fixing Gutter 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge. 68 Dismantling cement conglomerate floors 25mmto 50mm thick without concrete base 69 Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type 70 Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 71 Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing 72 Credit Of Sheets 73 Boundary Wall 74 Excavation in Soil (any type) using HydraulicExcavator CK 90 with hydraulic excavator of 0.9cum bucket capacity including cutting, trimmingbottom and side slopes, in accordance withrequirements of lines, grades and cross sections,including all lifts and combined lead upto 30m 75 Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type 76 Reinforced cement cocrete M-25 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steel reinforcement, centering and shuttering in foundation and plinth. 77 Reinforced cement cocrete M-25 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steel reinforcement, centering and shuttering in Superstructure. 78 Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering 79 Centering and shuttering for faces of walls, partitions, retainingwallsand the like (vertical or battering including attached pilasters buttresses etc 80 Cold twisted deformed (ribbed/ tor steel) Bars Fe 550 grade as per IS 1786-2008 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete. 81 First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. 82 12.5mm thick Cement Plaster in CM 1:4 83 20mm thick Cement Plaster in CM 1:4 84 Shed work 85 Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25%-40%. should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 86 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 87 Providing and fixing Gutter 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge. 88 Providingandfixing 110mmdia.U.P.V.CRain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing duringmasonary complete as perspecificationsandtotheentiresatisfactionof Engineer-in-charge 89 Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type 90 Providingand laying 80mm thick factory made cement concrete interlocking Paving blocks of M 40 grade manufactured by block making machine equipped with steel mouldclampedtoa strongvibratorytablewithhydraulicpressure for compactionofconcreteasper IRCSP63-2014 andof approvedsizeanddesign/ shape laid in Ordinary Grey Colour and pattern over andincluding40mmthickcompactedbedof coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in Charge 91 New construction of washroom 92 Stripping and stacking slate or tiles of a roof. 93 Dismantling concrete Reinforced cement concrete 94 Credit Of Old Steel 95 Dismantling brick work tile, masonry or tile lining 96 Credit Of Tiles 97 Credit Of Bricks 98 Credit Of Brick Bats 99 Credit Of Tiles Bats 100 Loading +Unloading + Carriage Of Disposable Material 101 Dismantling cement conglomerate floors 25mmto 50mm thick including concrete base. 102 Excavation in Soil (any type) using HydraulicExcavator CK 90 with hydraulic excavator of 0.9cum bucket capacity including cutting, trimmingbottom and side slopes, in accordance withrequirements of lines, grades and cross sections,including all lifts and combined lead upto 30m 103 Cement concrete 1:6:12 with stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type 104 First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth 105 First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. 106 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in1:4 cement mortar in superstructure 107 Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. 108 Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) 109 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 110 Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth 111 Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. 112 Cold twisted detormed (Ribbed/Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works,where not including in the complete rate of RCC including bending and binding placing in position complete 113 Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at1.65 Kg per sqm laid hot and sanded 114 12.5 mm thick cement plaster 1:5 115 20mm thick cement plaster 1:5 in two coat work 116 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 117 Applyingprimingcoatwithcement primer in all shade on newly plastered or concrete exterior surface 118 Wall paintingwith plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) 119 Finishingwallswith acrylic smooth exterior paint of required shade with twoo rmore coats applied @ 1.67 litre/10Sqm over and including base coato fwaterproofingCementPaint applied @ 2.20 Kg/10 Sqm 120 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 121 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In Charge. (Glazing and paneling to be paid for separately) :For fixed portion and chaukhats 122 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In Charge. (Glazing and paneling to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required 123 Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. (i) 6mm thick ACP Sheet 124 ProvidingPolyester Powder coating 50micron any coloured specified to alumnumsection of varioussizes includingcarriageofmaterial from market to workshop & workshop to site of work. 125 Providing and fixing hydraulic door closer ISI mark with necessary screw etc.complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm) 126 Providing an fixing MS of Double action spring hinges with necessary screws etc.complete (b) 125mm 127 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm 128 Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm 129 Applying priming coat with metal primer on new steel or iron work including preparation of surface. 130 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. 131 Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect 132 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated leadupto 1000 metres 133 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated leadupto 1000 metres Labour Rate Only 134 Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm sand filling using mechanical mixer for mixing of material 135 Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material 136 Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 137 Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 138 Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. 139 Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. 140 Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. 141 Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing 142 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge . IS Code: 15658 (2006) 143 Dismantling brick edging as per CSR 8.5 (i) 144 Road Work 145 Earth work in excavation in foundation Comp. as per CSR 24.6 c 146 Providing and laying brick on end edging as per CSR 24.14 147 Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications 148 Providing, laying, spreading and compacting stone aggregates of Grading I to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical specifications (without screening for low volume Roads/undersigned) 149 Providing, laying, spreading and compacting stone aggregates of Grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical specifications (without screening for low volume Roads/undersigned) 150 Making 50 mm x 50 mm furrows 45 degree to the center line of the road and at one metre interval in the existing bituminous wearing coarse including sweeping and disposal of excavated material within 1000 metres lead complete as per technical (Full surface area will be measured for payment) CSR 24.10 151 Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1kg per sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 509 of MORT&H specifications 152 Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical specifications 153 Providing, laying and compaction of open - grade surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a Continuous type hot mix plant with bituminous binder VG-10 @ 1.46kg per sqm, laid with Paver Finisher Mechanical and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 510 of MORT&H specifications 154 Providing and laying of premix sand seal coat premixed in Continuous type hot mix plant using specified fine aggregates and penetration grade bitumen VG-10 @ 0.68kg per sqm, laid to the specified levels, grade and cross fall complete as per technical clause 511 of MORT&H specifications 155 Kassi work undressed involving an average horizontal throw up to 2.0metres and an average vertical lift up to 0.5 metres including breaking of clods. 156 ROAD SAFETY MEASURES 157 Place Identification sign board 900x600mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 including 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012 as per CSR 24.47 b 158 Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications as per CSR 24.57 159 Credit of materials Brick Bats 160 Credit of materials Bricks 161 ELECTRICAL SERVICES 162 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: 163 Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½ deep for walls and CI 3 deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 164 Wiring fan point (Without fan box) 165 Wiring light point 166 Wiring 6Amp. wall socket point 167 Wiring 6Amp. Plug control comprising wall socket point 168 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 169 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 170 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 171 Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) 172 Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- 173 PVC Flexible Pipe 25mm dia. 174 PVC INSULATED FR COPPER CONDUCTOR CABLES: 175 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 176 Overall size 1.5sq.mm (Un-sheathed 177 Overall size 2.5sq.mm (Un-sheathed) 178 Overall size 4sq.mm (Un-sheathed) 179 Overall size 16sq.mm (Un-sheathed) 180 COPPER EARTHING: 8 SWG COPPER EARTHING 181 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia.125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 182 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 183 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 184 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 185 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCBs/ RCBOs/ RCCBs: 186 Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBOs/ RCCBs in the distribution board (For SP&N distribution board with provision DP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: 187 TP&N Horizontal Double Door Distribution Board 6 way each 188 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCBs as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 189 TP&N Double Door Vertical DBs 4 way each (With provision of FP MCCB 125amp) 190 MINIATURE CIRCUIT BREAKERS: 191 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 192 MCB Single Pole 6-32amp. (10kA, Curve-C) 193 MCB Double Pole 40amp. (10kA, Curve-C) 194 MCB Four Pole 50, 63amp. (10kA, Curve-C) 195 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 196 MCCBs (MOULDED CASE CIRCUIT BREAKER): 197 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 198 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 199 XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): 200 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 201 Overall size 10sq.mm (2Core) Un-armoured (On-Surface) 202 Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- 203 Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. 204 Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCBs) complete in all respect as approved and desired by the Engineer In-Charge at site:- 205 SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement 206 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 207 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 208 Overall size 16sq.mm (4Core) Un-armoured (Loose) 209 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 210 Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.) 211 Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary 212 Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48) suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturers guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site 213 Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with Louver shutter of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. 214 Supply and erection of High Bay luminaire 80 Watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Honble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB. 215 Supply and erection of LED Flood Light 100 watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Honble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB. 216 Special Repairs,Renovation & upgradation to Existing E.I in Workshop-02 Special attached to ITI, Bathinda 217 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: 218 Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½ deep for walls and CI 3 deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 219 Wiring fan point (Without fan box) 220 Wiring light point 221 Wiring 6Amp. wall socket point 222 Wiring 6Amp. Plug control comprising wall socket point 223 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 224 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 225 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 226 Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) 227 Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- 228 PVC Flexible Pipe 25mm dia. 229 PVC INSULATED FR COPPER CONDUCTOR CABLES: 230 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 231 Overall size 1.5sq.mm (Un-sheathed 232 Overall size 2.5sq.mm (Un-sheathed) 233 Overall size 4sq.mm (Un-sheathed) 234 Overall size 16sq.mm (Un-sheathed) 235 COPPER EARTHING: 8 SWG COPPER EARTHING 236 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia.125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 237 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 238 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 239 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 240 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCBs/ RCBOs/ RCCBs: 241 Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBOs/ RCCBs in the distribution board (For SP&N distribution board with provision DP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: 242 TP&N Horizontal Double Door Distribution Board 6 way each 243 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCBs as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 244 TP&N Double Door Vertical DBs 4 way each (With provision of FP MCCB 125amp) 245 MINIATURE CIRCUIT BREAKERS: 246 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 247 MCB Single Pole 6-32amp. (10kA, Curve-C) 248 MCB Double Pole 40amp. (10kA, Curve-C) 249 MCB Four Pole 50, 63amp. (10kA, Curve-C) 250 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 251 MCCBs (MOULDED CASE CIRCUIT BREAKER): 252 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 253 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 254 XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): 255 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 256 Overall size 10sq.mm (2Core) Un-armoured (On-Surface) 257 Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- 258 Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. 259 Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCBs) complete in all respect as approved and desired by the Engineer In-Charge at site:- 260 SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement 261 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 262 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 263 Overall size 16sq.mm (4Core) Un-armoured (Loose) 264 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 265 Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.) 266 Supply and erection of High Bay luminaire 80 Watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Honble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB. 267 Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48) suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturers guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site 268 Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with Louver shutter of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. 269 Supply and erection of LED Flood Light 100 watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Honble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB. 270 Special Repairs,Renovation & upgradation to Existing E.I in Theory room attached to ITI, Bathinda 271 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: 272 Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½ deep for walls and CI 3 deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 273 Wiring fan point (Without fan box) 274 Wiring light point 275 Wiring call-bell point 276 Wiring 6Amp. Plug control comprising wall socket point 277 Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 278 Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. 279 Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 280 Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). 281 Wiring TV socket, Telephone socket and Networking socket points on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:- 282 Wiring Networking socket point RJ45 (one module) 283 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 284 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 285 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 286 Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) 287 Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- 288 PVC Flexible Pipe 25mm dia. 289 PVC INSULATED FR COPPER CONDUCTOR CABLES: 290 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 291 Overall size 1.5sq.mm (Un-sheathed 292 Overall size 2.5sq.mm (Un-sheathed) 293 Overall size 4sq.mm (Un-sheathed) 294 Overall size 16sq.mm (Un-sheathed) 295 COPPER EARTHING: 8 SWG COPPER EARTHING 296 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia.125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 297 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 298 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 299 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 300 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCBs/ RCBOs/ RCCBs: 301 Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBOs/ RCCBs in the distribution board (For SP&N distribution board with provision DP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: 302 TP&N Horizontal Double Door Distribution Board 6 way each 303 MINIATURE CIRCUIT BREAKERS: 304 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 305 MCB Single Pole 6-32amp. (10kA, Curve-C) 306 MCB Double Pole 40amp. (10kA, Curve-C) 307 MCB Four Pole 50, 63amp. (10kA, Curve-C) 308 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 309 MCCBs (MOULDED CASE CIRCUIT BREAKER): 310 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 311 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 312 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCBs as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 313 TP&N Double Door Vertical DBs 4 way each (With provision of FP MCCB upto 125amp) 314 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 315 Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) 316 Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- 317 Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. 318 XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): 319 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 320 Overall size 10sq.mm (2Core) Un-armoured (On-Surface) 321 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 322 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 323 Overall size 25sq.mm (3½ Core) Un-armoured (Loose) 324 Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCBs) complete in all respect as approved and desired by the Engineer In-Charge at site:- 325 SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement 326 Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 327 Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 328 Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48) suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturers guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site 329 Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with aluminium louver shutter double ball bearing, longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. 330 Supply and erection of LED Flood Light 100 watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Honble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB. 331 Special Repairs,Renovation & upgradation to Existing E.I in Admin Block attached to ITI, Bathinda 332 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: 333 Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½ deep for walls and CI 3 deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 334 Wiring fan point (Without fan box) 335 Wiring light point 336 Wiring call-bell point 337 Wiring 6Amp. wall socket point 338 Wiring 6Amp. Plug control comprising wall socket point 339 Wiring 16/20Amp. power plug control point 340 Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 341 Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. 342 Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 343 Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). 344 Wiring TV socket, Telephone socket and Networking socket points on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:- 345 Wiring Networking socket point RJ45 (one module) 346 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 347 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 348 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 349 Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) 350 Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- 351 PVC Flexible Pipe 25mm dia. 352 PVC INSULATED FR COPPER CONDUCTOR CABLES: 353 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 354 Overall size 1.5sq.mm (Un-sheathed 355 Overall size 2.5sq.mm (Un-sheathed) 356 Overall size 4sq.mm (Un-sheathed) 357 Overall size 16sq.mm (Un-sheathed) 358 COPPER EARTHING: 8 SWG COPPER EARTHING 359 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia.125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 360 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 361 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 362 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 363 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCBs/ RCBOs/ RCCBs: 364 Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBOs/ RCCBs in the distribution board (For SP&N distribution board with provision DP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: 365 TP&N Horizontal Double Door Distribution Board 6 way each 366 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCBs as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 367 TP&N Double Door Vertical DBs 4 way each (With provision of FP MCCB upto 125amp) 368 MINIATURE CIRCUIT BREAKERS: 369 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 370 MCB Single Pole 6-32amp. (10kA, Curve-C) 371 MCB Double Pole 40amp. (10kA, Curve-C) 372 MCB Four Pole 50, 63amp. (10kA, Curve-C) 373 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 374 MCCBs (MOULDED CASE CIRCUIT BREAKER): 375 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 376 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 377 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 378 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 379 Overall size 35sq.mm (3Core) Un-armoured (Loose) 380 XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): 381 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 382 Overall size 10sq.mm (2Core) Un-armoured (On-Surface) 383 Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- 384 Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. 385 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 386 Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) 387 Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCBs) complete in all respect as approved and desired by the Engineer In-Charge at site:- 388 SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement 389 Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary 390 Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 391 Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48) suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturers guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. 392 Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with Louver shutter of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. 393 Supply and erection of Recessed Mounted 36 Watt LED 2x2 panel (including constant LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 394 Supply and erection of Slim Recessed mounted, Round downlighter 18 watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with CRCA sheet with control gear (IP 20 protection), THD<10%, CRI minimum 70, Low power LED with wattage Less 1 Watt, Surge Protection 2.5KV and above as per IS/ IEC Standards, efficacy of LED fixture minimum 100 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Honble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. 395 Supply and erection of LED Flood Light 100 watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Honble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB. 396 Special Repairs,Renovation & upgradation to Existing E.I in IRG Block attached to ITI, Bathinda 397 REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: 398 Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) 399 Wiring fan point (Without fan box) 400 Wiring light point 401 Wiring call-bell point 402 Wiring 6Amp. wall socket point 403 Wiring 6Amp. Plug control comprising wall socket point 404 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 405 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 406 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 407 Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- 408 PVC Flexible Pipe 25mm dia. 409 PVC INSULATED FR COPPER CONDUCTOR CABLES: 410 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 411 Overall size 10sq.mm (Un-sheathed) 412 COPPER EARTHING: 8 SWG COPPER EARTHING 413 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia.125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 414 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 415 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 416 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 417 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCBs/ RCBOs/ RCCBs: 418 Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBOs/ RCCBs in the distribution board (For SP&N distribution board with provision DP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: 419 SP&N Double Door Distribution Board 8 way each 420 MINIATURE CIRCUIT BREAKERS: 421 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 422 MCB Single Pole 6-32amp. (10kA, Curve-C) 423 MCB Double Pole 40amp. (10kA, Curve-C) 424 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 425 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 426 Overall size 10sq.mm (2Core) Un-armoured (Loose) 427 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 428 Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.) 429 Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- 430 Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. 431 XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): 432 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 433 Overall size 10sq.mm (2Core) Un-armoured (On-Surface) 434 Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCBs) complete in all respect as approved and desired by the Engineer In-Charge at site:- 435 SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement 436 Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary 437 Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 438 Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48) suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturers guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. 439 Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with Louver shutter of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. 440 Supply and erection of LED Flood Light 100 watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Honble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB. 441 Special Repairs,Renovation & upgradation to Existing E.I in World Bank Block attached to ITI, Bathinda 442 REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: 443 Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) 444 Wiring fan point (Without fan box) 445 Wiring light point 446 Wiring 6Amp. wall socket point 447 Wiring 6Amp. Plug control comprising wall socket point 448 Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 449 Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). 450 Wiring TV socket, Telephone socket and Networking socket points on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:- 451 Wiring Networking socket point RJ45 (one module) 452 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 453 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 454 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 455 Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) 456 Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- 457 PVC Flexible Pipe 25mm dia. 458 PVC INSULATED FR COPPER CONDUCTOR CABLES: 459 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 460 Overall size 1.5sq.mm (Un-sheathed 461 Overall size 2.5sq.mm (Un-sheathed) 462 Overall size 4sq.mm (Un-sheathed) 463 Overall size 16sq.mm (Un-sheathed) 464 COPPER EARTHING: 8 SWG COPPER EARTHING 465 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia.125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 466 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 467 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 468 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 469 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCBs/ RCBOs/ RCCBs: 470 Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBOs/ RCCBs in the distribution board (For SP&N distribution board with provision DP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: 471 TP&N Horizontal Double Door Distribution Board 6 way each 472 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCBs as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 473 TP&N Double Door Vertical DBs 4 way each (With provision of FP MCCB upto 125amp) 474 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 475 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 476 MINIATURE CIRCUIT BREAKERS: 477 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 478 MCB Single Pole 6-32amp. (10kA, Curve-C) 479 MCB Double Pole 40amp. (10kA, Curve-C) 480 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 481 MCB Four Pole 50, 63amp. (10kA, Curve-C) 482 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 483 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 484 Overall size 25sq.mm (3½ Core) Un-armoured (Loose) 485 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 486 Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) 487 Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- 488 Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. 489 XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): 490 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 491 Overall size 10sq.mm (2Core) Un-armoured (On-Surface) 492 Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCBs) complete in all respect as approved and desired by the Engineer In-Charge at site:- 493 SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement 494 Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 495 Supply and erection of LED Flood Light 100 watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Honble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB. 496 Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 497 Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48) suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturers guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. 498 Special Repairs,Renovation & upgradation to Existing Power Wiring in workshop-01 Main attached to ITI, Bathinda 499 COPPER EARTHING: 500 Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 501 Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) 502 Earthing with 25mm x 3mm Copper Tape (upto 8Metre in Length) 503 Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- 504 Additional Length 20mm x 3mm thick Copper Tape 505 Additional Length 25mm x 3mm thick Copper Tape 506 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia.125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 507 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 508 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 509 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 510 MINIATURE CIRCUIT BREAKERS: 511 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 512 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 513 MCCBs (FOR PANELS & SHEET ENCLOSURE): 514 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 515 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 516 MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 517 MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting 518 MCCBs (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 519 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 520 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 521 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 522 Overall size 16sq.mm (2Core) Un-armoured (Loose) 523 Overall size 16sq.mm (4Core) Un-armoured (Loose) 524 Overall size 25sq.mm (3½ Core) Un-armoured (Loose) 525 Overall size 70sq.mm (3½ Core) Un-armoured (Loose) 526 Overall size 185sq.mm (3½ Core) Un-armoured (Loose) 527 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 528 Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) 529 Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) 530 Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) 531 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCBs as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 532 TP&N Double Door Vertical DBs 12 way each (With provision of FP MCCB upto125amp.) 533 Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- 534 ICDP Switch 32amp., 415volts 535 ICTPN Switch 32amp., 415volts 536 Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- 537 Cable Tray Size 150mm x 50mm x 50mm (2mm thick) 538 Cable Tray Size 300mm x 50mm x 50mm (2mm thick) 539 Cable Tray Size 450mm x 50mm x 50mm (2mm thick) 540 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 541 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 542 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 543 Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) 544 Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) 545 Heavy Gauge PVC Conduit Pipe 32mm dia.(On Surface) 546 LT PANELS: Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. 547 The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. 548 The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. 549 Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work.Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCBs. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. 550 Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CTs & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCBs to be installed in the cubical panel Enclosure (Excluding the cost of MCCBs) as per following:- 551 LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCBs 40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm) 552 LT Panel enclosure having space for 1No. Incomer MCCB 630Amp. and 6Nos. outgoing MCCBs 40amp. to 250amp. (Option: MCCB 200-250amp.= 2Nos. and MCCBs 40-100amp.= 4Nos.) according to the requirement at site (Approx. size 1475 x 1800 x 400mm) (For Main LT Panel) 553 Special Repairs,Renovation & upgradation to Existing Power Wiring in workshop-02 special attached to ITI, Bathinda 554 COPPER EARTHING: 555 Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 556 Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) 557 Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- 558 Additional Length 20mm x 3mm thick Copper Tape 559 Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia.125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 560 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 561 Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- 562 Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 563 MINIATURE CIRCUIT BREAKERS: 564 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 565 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 566 MCCBs (FOR PANELS & SHEET ENCLOSURE): 567 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 568 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 569 MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 570 MCCBs (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 571 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 572 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCBs as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 573 TP&N Double Door Vertical DBs 12 way each (With provision of FP MCCB upto 125amp.) 574 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 575 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- 576 Overall size 16sq.mm (2Core) Un-armoured (Loose) 577 Overall size 16sq.mm (4Core) Un-armoured (Loose) 578 Overall size 25sq.mm (3½ Core) Un-armoured (Loose) 579 Overall size 70sq.mm (3½ Core) Un-armoured (Loose) 580 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 581 Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) 582 Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) 583 Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) 584 Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- 585 ICDP Switch 32amp., 415volts 586 ICTPN Switch 32amp., 415volts 587 Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- 588 Cable Tray Size 150mm x 50mm x 50mm (2mm thick) 589 Cable Tray Size 300mm x 50mm x 50mm (2mm thick) 590 Cable Tray Size 450mm x 50mm x 50mm (2mm thick) 591 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 592 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 593 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 594 Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) 595 Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) 596 Heavy Gauge PVC Conduit Pipe 32mm dia.(On Surface) 597 LT PANELS:Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. 598 The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. 599 The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. 600 Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCBs. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. 601 Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CTs & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCBs to be installed in the cubical panel Enclosure (Excluding the cost of MCCBs) as per following:- 602 LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCBs 40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm) (For Sub LT Panel) 603 Providing On-gridSolar Power Generation System (ON-Grid 46 KW Solar System) 604 Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum capacity 20kw including required quantities of SPV modules (High power density Monocrytalline based single module of capacity +400 watt) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. Features :- 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 142862. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 605293. Structure 25 Years service life with AMC & certified under IS 2062 20114. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material)5. Annual Maintenance contract for the period of 5 YearsConditions:# The Plant will be installed as per MNRE and GOI guidelines and specifications. (Detail of material as per Annexure-I attached)#The work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor#The capacity of solar power plant my increase or decrees as availability of site it can also be totally removed from executive endThe Rate are inclusive of all taxes including GST 605 Public Health Services 606 Sub Work-1 607 Sub Head-1 Internal Sewerage System 608 Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B 609 110mm o/d SWR UPVC pipe lines laid complete 610 90mm o/d SWR UPVC pipe lines laid complete 611 Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. 612 For 110mm i/d pipes 613 Door Elbow 90 Degree (All side socketed) 614 Vent Cowls 615 Coupler 616 P Trap/Floor Trap 110mm x 110mm 617 With 110mm o/d outlet deep seal at Ground Floor 618 For 90mm o/d pipes 619 Door elbow 90 degree (all side socket) 620 Vent Cowls 621 Coupler 622 Single Tee 623 Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. 624 Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) 625 110mm o/d 626 90mm o/d 627 Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. 628 M.S. Holder bats clamps for 100mmi/d H.C.I. pipes 629 M.S. Holder bats clamps for 90mm o/d 630 Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 631 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm 632 Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 633 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal 634 Cement concrete 1:2:4 With stone ballast or shingle mixing by manual means (INCLUDING CARRIAGE) 635 Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. 636 Through wall 11.43 cm thick 637 Through wall 22.86 cm thick 638 Sub Head-2 Internal Water Supply System 639 CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 640 SDR 11 CPVC pipes & fittings 20mm o/d 641 CPVC SDR 11 Pipe & fitting 25mm o/d 642 Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm 643 Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. 644 Through wall 11.43 cm thick 645 Through wall 22.86 cm thick 646 Providing, fixing and jointing Cpvc Union Couplings with Upvc Pipes complete in all respect. 647 25mm i/d CPVC Union 648 Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. 649 25mm i/d CPVC Ball valves 650 Providing, fixing and jointing Cpvc Tank Nipple with Upvc Pipes complete in all respect. 651 25mm i/d CPVC tank nipple 652 Sub Head - 3 Sanitary Installation 653 Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. 654 Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. 655 Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. 656 Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect. 657 Providing and fixing jet spray with 2-6 long PVC pipe.With PTMT nut 658 Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. 659 Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tubeconnection 300 mm long complete. 660 Vitreous white Chinaware Partition 661 Large partition size 75 x 16.5 x 36.5 cm 662 Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. 663 Size 550 mm x 400 mm x 815mm 664 Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. 665 Vitreous chinaware standard white pedestal for wash hand basin. 666 Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. 667 Size 560mm x 450mm (Under counter oval) 668 Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut 669 Providing and fixing P.V.C Waste Pipe Collapsible 32mm complete in all respect. 670 Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. 671 C.P brass towel ring 672 Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. 673 Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) 674 Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. 675 C.P Brass bib cock foam flow without flange 676 Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. 677 C.P.brass 15mm Angle valve without flange 678 C.P.brass 15mm Concealed stop cock with flange 679 Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. 680 Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long 681 Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass Accessories: 682 C.P. brass toilet roll holder with flap 683 Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 6 pegs 684 Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks 685 Construction of Plateform complete as per specification & as desired by Enginer-in-charge 686 For 1000 ltr Water Tank 687 For 2000 ltr Water Tank 688 For 2500 ltr Water Tank 689 Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. 690 35mm dia 900mm (36”) long 691 35mm dia 1200mm (48”) long 692 Foldable U Type 762mm long 693 Providing and fixing in position automatic brass Ball Cock in tanks.Plastic Ball Cock with rod andPlastic Ball 694 25mm i/d 695 Providing and fixing sanitary napkin vending machine complete. 696 Sub Head-4 Flooring and Wall Tile 697 Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material 698 Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . 699 Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 700 Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. 701 Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 702 Cement concrete 1:2:4 With stone ballast or shingle mixing by manual means 703 Sub Head -5 Water Cooler & RO 704 Providing & fixing in position Water Coolerwithout Stablizer of approved make (to theapproval of Engineer-in-charge ) includingcarriage complete in all respect. 705 Water Cooler Full Steel Body 150/150 ltr without StablizerDetail as per Table-3 706 Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge) including carriage and fixing in position complete in all respect. 707 Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- 708 Automatic Voltage Stablizer 2 KVA 709 Sub Head - 1 Fire Fighting Arrangement 710 Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.4.5 Kg. Capacity 711 Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.4 Kg. Capacity 712 Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved makecomplete in all respect. 713 Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 714 110 mm o/d pipes 715 160 mm o/d pipes 716 200 mm o/d pipes 717 Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. 718 Depth not exceeding 3 m. BGL.All kinds of soil except rocky 719 Cement concrete 1:6:12 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type 720 Dismantling of metalled road with bituminous course 50 to 75mm thick with base course and making good the same to its original condition complete in all respects 721 Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. 722 Inside size 90x150 cm and 120 cm deep 723 Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 upto1.80 m increase in depth. 724 Inside size 90x150 cm 725 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 726 Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda 727 Sewer connections upto 300 mm id 728 Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. 729 Earth work upto 1.5 m. Depth All classes of soil except rocky 730 Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects..B) uPVC Pipe 10 Kgf/cm2 731 25mm i/d 732 Providing, fixing and jointing Cpvc Union Couplings with Upvc Pipes complete in all respect. 733 25mm i/d Union 734 Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. 735 25mm i/d CPVC Ball valves 736 Providing, fixing and jointing Upvc Tank Nipple with Upvc Pipes complete in all respect. 737 25mm i/d CPVC tank nipple 738 Sub Work-5 739 Sub Head-1 Roof Top Rain water Harvesting 740 Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 741 160mm o/d PVC pipe of 4 Kgf. / sqcm 742 200mm o/d PVC pipe of 4 Kgf. / sqcm 743 Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects. 744 For depths not exceeding 3.0 metre B.G.L.All kinds of soil except rocky 745 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 746 Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge 747 Haudi Inside size 90x 90 cm and90 cm deep 748 Construction of Haudi internal size 0.45mtr x 0.45mtr & 0.45mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x450 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge 749 Construction of Rain water recharge well 3.00mtr i/d dia with working depth 4.00mtr consisting of drilling bore 250mm dia 35mtr, supplying and lowering pvc medium well casing & screen pipe 200 mm dia duly plugged from top with bail plug, fixing MS clamp, MS socket, Well size 3.00 mtr internal dia, 4.00 mtr deep constructed with BB in 1:5 cement sand mortar,plastered from inside, RCC slab, filtered media in 2 Layers, 2Nos RCC Man hole cover conneted with collecting chamber size 1mtr x 1mtr x 1.20 mtr deep providing and fixing MS grating and all other relevent material required as per site complete in all respect as per drawing attached and entire satisfaction of the Engineer-in-charge . (As per Detail Attached) (Note :- Payment will be made as per CSR Based Rates Plus/Minus Quoted rates).. 750 Dismantling of wall tiles at any floor of thebuilding, laid in cement mortar including scrapingof cement plaster and disposal of malba at asuitable place within a distance of 100 Mtrs of thecomplex complete in all respect. 751 Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. 752 Dismantling Sanitary fixtures such asEurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge. 753 Eurpoean/Indian/Orissa W.C., 754 PVC / China Ware Cistern 755 Wash Hand Basin / Urinal Pot 756 CP Bib Cock/Angle Cock/Stop Cock/Shower/Bottle Trap 757 Dismantling concrete Cement Concrete Plain 1:2:4 758 Labour for carrying dismantled material Complete. Total in Figures 65881642.96 65881642.96 INR Six Crore Fifty Eight Lakh Eighty One Thousand Six Hundred & Forty Two and Paise Ninety Six Only Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information