Tender For Special Repair To Building No Gtc-279/01 To 04 Govt Md Accommodation At Certain Unit At Mil Station Kota.; 1 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 2 Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.complete all as specified and as directed. 3 Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed. 4 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. 5 Taking down existing treatment of any description such as PCC padding, lime concrete, mud phuska etc. and any numbers of layers upto any thickness from roof including scraping and roughening old by picking, sweeping clean and washing down and removing debris outside MD land complete all as specified and as directed. 6 Material & labour for rendering 20 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction finished even and fair complete all as specified and as directed. (Note;- water proofing compound shall be measured and paid separately as supply only) 7 M & L for brushing neat cement slurry with 3.0 kg of cement per square meter complete all as specified and as directed. 8 M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73,
[email protected] Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii)The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv)In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates. (vi) One coat of aluminium reflective paint should be applied on APP after sealing the joints of APP. 9 M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate in roof kerbs or mud stops,padding, rounded or chamfered on edges complete all as specified and as directed. 10 M & L for 40 mm thick cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair including provision of contraction joint 6 mm wide X 10 mm deep at 1.2 metre interval or part thereof, both ways on top of PCC padding and including filling with mastic bitumen with 85/25 industrial grade bitumen and coarse sand mixture. 1:3 by weight complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. 11 Material and labour for plastering 15 mm thick on other than fair faces of brick wall or stone surfaces in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: Water proofing compound shall be measured and paid for separately. 12 M&L for cleaning of walls and floor of sunken portions including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm, torching overlaps with a propane or a butane gas torch with an overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold applied bituminous primer all as per manufacturer’s instructions, complete all as directed. Note: (i) The waterproofing treatment shall be got carried out through the manufacturer or their authorized applicators only. (ii) HDPE spout pipe 32mm bore of required length shall be provided and rates for same shall be included in above quoted rate. 13 Providing & applying evenly a coat of industrial bitumen 85/25 @ 1.2 kg per sqm including cleaning over primed surfaced (interval between 1st & 2nd coat shall be as directed by Engineer-in-Charge) complete all as specified and as directed. 14 Supply only liquid water proofing compound complete all as specified and directed. 15 M&L for joint free non skidceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6,complete all as specified and directed. Make :- Kajaria (Pavigers)/Johnsons (Elite Plus)/ Somany (Plain star Beige). 16 M&L for joint free non skid matt finishceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6,complete all as specified and directed. Make :- Kajaria (Matt finish)/Johnsons (Matt finish)/ Somany (Matt finish). 17 M&L for joint free non skid matte finishceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm fixed on vertical surfaces as skirting, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed. Make :- Kajaria (Matt finish)/Johnsons (Matt finish)/ Somany (Matt finish). 18 M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X300X7mm/ 300X600X7-8mm/ 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed. Make :- Kajaria (Impression)/Johnsons (Elite Plus)/ Somany (Juene Glossy). 19 M & L for 16-18 mm thick granite of black colour (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. Note- The quoted rates shall be inclusive of - (i) Moulding of front and side of slab including polishing. (ii) Granite shall be laid in single piece of any size with rounding of edge and a groove shall be provided beneath the projection portion of slab. (iii) Gas pipe hole should be provided in kitchen slab. 20 M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed. 21 Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. 22 Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and fair complete all as specified and as directed. 23 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) mixed with and including water proofing compound as per manufacturer instructions in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. 24 Dismantling loose concrete cover of RCC columns,beams,slabs,Chajjas and the like as directed ,roughening and cleaning concrete surfaces with steel wire brushes,washed with water and allowed to dry,including dusting of steel reinforcement,providing fabric mild steel wire mesh 75 mm x 75 mm of2 mm dia as reinforcement to concrete surfaces,applying adhesive/admixyure over steel mesh and providing ordinary portland cement 53 grade and 2 parts of banas sand mixed with adhesive/admixture at the rate as per manufactures instruction or 2% by wt of cement all as directed with apressure of 2 to 2.5 kgs per sqm by guniting machine including necessary padding,steel scaffolding and shuttering for working platform/formwork etc complete all as specified and directed 25 Preparation of newly plastered surfaces on ceilings and applying three coats of white wash complete all as specified and as directed. 26 M&L for preparing old surface of ceiling, plastered or unplastered by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts andtreatingoil and greasy spots & applying one coat of white wash etc complete all as specified & as directed. 27 M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the existing surfaces complete all as specified and as directed. 28 Complete removal of existing treatment of wall and M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer over putty to match the surfaces complete all as specified and as directed. 29 M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed. Note :- (i) All coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI / Manual applicationAllow 6-8 hrs to dry the surface in subsequent coats of paint (ii) Make should bedulux weather shield max/Nerolac Excel Everlast 12/Asian paint ultima protek / Berger weather coat long life 10 orTechno commercially equivalent makes specified in PS complite all as specified and directed. 30 Material and labour for complete removal of existing treatmentforpreparation of old surface of walland applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed.Note :- (i) cracks of wall plaster should befilling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm / ltr as per manufacturers instructions. (ii) All coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI / Manual applicationAllow 6-8 hrs to dry the surface in subsequent coats of paint(iii) Make should bedulux weather shield max/Nerolac Excel Everlast 12/Asian paint ultima protek / Berger weather coat long life 10 orTechno commercially equivalent makes specified in PS complite all as specified and directed. (iv) decorated treatment on wall / ceiling / chajja by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7/9 to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc 31 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed. 32 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed. 33 Taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed. 34 Taking down and refixing in same opening wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each including resecuring or easing & adjusting complete all as specified and as directed. 35 S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. 36 M&L for 30mm thick FACTORY MADE MOULDED DOOR SHUTTER-WOOD FREE consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 25mm x 25mm for stiles, top and bottom rails. M. S. frame shall have a coat of steel primers. The inner panel shall consist of 25mm thick EPS of Density 23 Kg /Cbm. bonded with 2mm thick termite proof, water proof and fire resistant moulded PVC Sheet Manufactured by an ISO-9001-2015 certified company, with 2, 4, 6 raised panel design in different plain and / or prelam colours after routing the Moulded design on one side & 2mm plain and /or prelam PVC sheet on other side of the EPS. The edge of panel to be sealed with lipping of 15mm wide PVC sheet baton ( made by sticking 2mm rigid foam PVC sheets of 5mm (±0.25) thickness using PVC solvent cement ) and stile sides 25mm (5mm x 5nos.) thick and 30mm width PVC Sheet fitted along M.S. tube for hardware provision & for lock 25mm thick( 5mmx5nos.) PVC sheet of size 150mm x 200mm fixed with inner side of EPS Panel etc. complete all as per specifications and drawings as applicable to item 08103 given in SSR Part–II. 37 Ditto~ all as per srl item here-in-before but wire gauged ie panel will be of wire gauze in lieu of wood grain printed PVC sheet panel. The wire gauze warped on additional square 8 mm M.S solid tube and this tube shall be welded to MS tube. The wire gauze shall be stretched to tighten firmlycomplete all as specified and directed.NOTE:- Wire mesh will be measured and paid separately. 38 M & L for powder coated aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. 39 M & L for powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium section (thickness of powder coating not less than 50 micron) weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150 mm long (1 no.). hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed. 40 Supply and fix Aluminium deco grill Cat No DG-104, 10 mm thick ,cut to required size/shape and fixed in position with and including stranded aluminium frame of F section of size 23.04x15.3x1.4mm thick all as per manufacturer instructions complete all as specified and as directed. 41 Supply & fix toughened (tempered) safety glass as per IS 2553 (Part-1): 2018, flat, tinted 4 mm thick in black colour, fixed with steel, aluminium, metal frame work in windows/ doors/ partitions/ ventilators including rubber beading complete all as specified and as directed. 42 S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. 43 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and as directed. 44 M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 45 Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. 46 S & F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge and as per specification & drawing as applicable to item 08100A given in SSR Part – II (2020). (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Make:-Rajshri/Sintex/Accucel/Duraplast 47 S&F for factory made 30mm thick 100% Solid WPC ( Wood polymer Composite) Laminated Flush Door Shutter of required size comprising ofvirgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, (maximum toxicity index of 12 for 100 grm ) made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm, having good screw holding capacity ( Screw Withdrawal strength of 1800 N ( Face ) & 900 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pastedon both faces of shutterand fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company :For WC/Bathroom/Toilet/Kitchen/Balcony Doors. Make:-Rajshri/Sintex/Accucel/Duraplast 48 S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 49 S & F extruded aluminium alloy handle, fabricated type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 50 S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, dia of bolt 12 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. 51 S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and as directed. 52 S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. 53 S & F in renewal of 25 mm dia decorative powder coated aluminium curtain rods with decorative ball type side brackets complete all as specified and as directed. 54 S&F in renewal of 18 mm thick HDWPC (High density wooden plastic composite) kitchen cupboard/door shutter board one side colour/white laminated and other side decorative as in modular kitchen/cabinets fixed with minifix hardware where ever required including edge band 22 mm wide .80 m thick of matching colour on exposed surface of board fixed with polymaster adhesive including trimming edges of edge band to true line of thickness of board by manual trimmer fixed to wall etc complite all as specified and directed. Make:- Pearl wood or equivalent in Rajshri plastiwood/Greenply/Century PLywood. 55 M & L for teak wood lipping, 6 mm thick for 18 to 20 mm thick, block board, veneered particle board, prelaminated particle board fixed with nails complete all as specified and as directed. 56 S & F mild steel continuous hinge, 40 mm nominal size, 1 mm thick, type IV as per IS 3818: 1992, bright finish and fixed to cupboard shutter complete all as specified and as directed. 57 S & F aluminium alloy hasps and staples, type -1, safety type, size 125 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 including fixing with screws complete all as specified and as directed. 58 S & F ball catches with 8 mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed. 59 S & F extruded aluminium alloy handle, fabricated type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 60 S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, dia of bolt 12 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. 61 S & F in repairs vitreous china squatting pan, Orissa pattern, size 580 mm X 440 mm white with ‘P’ or ‘S trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed. 62 S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed. 63 S & F in renewal PVC valveless, symphonic action type, flushing cistern, 10ltr capacity. Low level, white with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull or lever, complete as specified and as directed. Make- CERA Cat No B1010102L/ Johnson cat part No J 85821Cor techno commercially equivalent makes specified in PS. 64 S & F in renewal of shower rose 125/150 mm size brass chromium plated withswivel joints including fixing steel pipe or unions with all necessary fittings complete all as specified and as directed.Make :- CERA cat part No F7020111AB/ Hindware cat part No F 160142/ Johnson cat part No JF 803899 or techno commercially equivalent Makes as specified in PS. 65 S & F in renewal of Bib taps 15mm dia,chromium plated, long body,with CP flange all as perfixed in repairs complete all as specified and as directed. Make :- CERA cat part No G 1017152 /Jaquar cat pat no VGP-81037/ Hindware cat part No F 740011or techno commercially equivalent makes specified in PS. 66 S & F in renewal of 15mm bore two way angle valve chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed with necessary fitting complete all as specified and directed. Make :- CERA cat part No G1017211 / Hindware cat part no F 740006 / Johnson cat part no JT 1643A or techno commercially equivalent Make specified in PS 67 S & F pillar taps, 15mm dia, long body/swan neck, fancy type suitable for fixing to wash basin screwed for iron pipe and fixed with necessary fittings and including PVC connection complete all as specified and as directed. Make :- CERA Cat Part No F1003103 / Jaquar cat Part No COP -021PM/ Hindware Cat Part No F 740002 or techno commercially equivalent makes specified in PS. 68 Supply and fixing 50 mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. 69 S & F 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 70 S & F in renewal of towel rail 600mm long of CP fixed with screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed. Make :-CERA Cat No.F5013104CH/Jaquar cat part No ACN-1111 SM/ Hindware cat part No F 450024or techno commercially equivalent makes specified in PS. 71 M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. 72 S & F in repairs sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed. 73 S & F in repair Kitchen stainless steel plate rack of size 120 cm x 90 cm x 18 cm with partition for small/ large plates fabricated out of 24 gauge stainless steel sheet including necessary fixing / fittings & making good the existing surfaces complete all as specified and as directed. 74 Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed. 75 Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed. 76 Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 77 Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 78 S&F in renewal of factory made pressed steel cupboard shutters alongwith frame, frame made of 1.25 mm thick PBI sheet and shutter made of 1.00 mm thick PBI sheet with 6 Nos 3.15 mm thick and 100 mm long steel hinges per shutter, godrej pattern locking arrangement with 12 mm dia vertical rod and lock with duplicate key & chrome finish handle, duly spray painted in factory with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer, complete with fastener, hold fast etc as required at site, complete all as specified and directed. (Total width including frame shall be measured for payment purpose). 79 Refixing 20 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. 80 Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed. 81 S & F rotational moulded polyethylene tripple layer water tanks, white colour (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. 82 S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed. 83 Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) of any internal dia set in cement mortar incl all fittings complete all as specified and as directed. 84 S & F 110mm dia PVC(SWR) single socketed soil waste pipes in any length with rubber ring joints fixed to wall with necessary fixing arrangement such as clamps, nuts bolts etc and making good the disturbed surface complete all as specified and as directed. 85 S & F PVC (SWR)bends of any radius of 75 mm dia with access door complete all as specified and as directed. 86 S & F PVC (SWR)bends of any radius of 110 mm dia with access door complete all as specified and as directed. 87 S & F PVC (SWR)branch piece single (single Y) equal or unequal suitable for 75 mm dia complete all as specified and as directed. 88 S & F PVC (SWR)branch piece single (single Y) equal or unequal suitable for 110 mm dia complete all as specified and as directed. 89 S & F PVC (SWR)vent cowl of 75 mm dia complete all as specified and as directed. 90 S & F PVC (SWR)vent cowl of 110 mm dia complete all as specified and as directed. 91 Supply and fixing in renewal of PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm complete all as specified and as directed. 92 M & L in renewal of PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and as directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 93 M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. 94 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. 95 Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. 96 M & L for machine cut Kota stone slab flooring 18 to 20 mm thick over and including cement screed bed of 15 mm thick in cement mortar 1:6, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. 97 M & L for 18 to 20 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on and including backing layer of 10 mm thick in cement mortar 1:4, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and as directed. 98 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, wall light fittings , tube light fittings, surface light fitting , ceiling light fittings , any types of fittings etc. removing materials to store for keeping in safe custody or for taking on credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 99 Taking down main switch/MCB/MCCB/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed. 100 Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed. 101 M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 102 M & L for point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 103 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 104 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 105 M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 106 M & L for point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 107 S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 108 S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 109 S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. 110 S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed. 111 S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. 112 S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed. 113 S & F ding dong bell, buzzer suitable for single phase, AC, 240 volts complete all as specified and as directed. 114 S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 115 S & F switch, 6 A, single pole, two way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 116 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be measured and paid separately.) 117 S & F LED tube fitting 4 feet 20 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed. 118 S & F LED tube light fitting 2 feet 10 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed. 119 S & F LED streetlight/ building security light nominal power 60 Watt, 230 V AC, outdoor type with aluminium pressure die-cast housing, polyester powder coated, IP 65/66 protection complete with in-built integrated electronic LED driver including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. 120 M & L for bracket made out of GI pipe 32 mm dia medium grade, 1.2 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down old unserviceable complete all as specified and as directed. 121 S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP011608C0001 or equivalent technocommercially equivalent make as specified in PS. 122 S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 123 S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 124 Supply and fix in renewal exhaust fan made of sturdy engineering plastic (having excellent impact and abrasion resistance, light weight and resistance to colour change), complete with louvers shutter, voltage 230V, 50 Hz, speed 1200 rpm, 250 mm sweep size, 5 number of blades, air delivery 860 cubic metre per hour, copper winding complete all as specified and as directed. 125 S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP021604C0001 or equivalent technocommercially equivalent make as specified in PS. 126 S & F miniature circuit breakers (MCB), four pole with four protected pole (FP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 40 to 100 Amp, Rated Short circuit capacity 16 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 127 Taking down ceiling fan 1200/1400 mm sweep / exhaust fans 300mm/ geyser of capacity upto 50 Ltr including disconnection of electric connection and deposited in E/M store yard complete all as specified and as directed. 128 S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 210 m³ per minute, minimum service value 6 m³ per minute per watt, 3 Nos metal blades protected with corrosion resistance paints, with brushless DC motor having electronic controllers that use sensors, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose of Make- Havells Cat No FHCNF5SWHT48 or Bajaj at No Energos26 251100EE or Orient Cat No FALCON BLDC or techno commercially equivalent makes specified in PS incl writting of MES srl No with black colour paint as provided by AGE E/M complelete all as specified and directed. Note- Fan down rod of suitable size upto 3 meter length shall be included in quoted rate. 129 S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers and all fixing accessories including making hole for fixing of exhaust fan of suitable size and making good the disturbed surface as per existing complete all as specified and directed. 130 Supplying, installing, testing & commissioning, Storage Geyser, five star rated, 25 litres Capacity, steel body with stainless steel inner tank material, shock proof, auto cut, on-off indicator, thermoplastic body, corrosion free with safety valve, fusible plug, thermal cut out including fixing by grouting and fastener complete all as specified and as directed. 131 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.