| Sl. No. | Item Description |
| 1 | B/R PORTIONTaking down of cement plaster of any description or thickness/chipping of cement concrete in any situation from brick or concrete surface including raking out of joints, hacking for key scrubbing down with water to received new plaster complete all as specified and directed. |
| 2 | M & L for rendering 15mm thick in cement mortar (1:4) on fair faces of solid block or concrete surfaces on walls finished even and smooth (without using extra cement) complete all as specified and directed. |
| 3 | M & L for rendering 15mm thick in cement mortar (1:6) on fair faces of solid block or concrete surfaces on walls finished evenand smooth (without using extra cement) complete all as specified and directed. |
| 4 | M & L for rendering 5mm thick on fair faces of brick work or concrete surfaces on ceilings finished even and smooth (without using extra cement) in CM (1:3) complete all as specified and directed. |
| 5 | M & L for preparing new/old plastered surfaces of wall and applying two coats ofanti fungal exterior acrylic emulsion on wall surfaces of any description complete all as specified and as directed. |
| 6 | M & L for preparing new plastered surfaces of wall and applying two coats of Oil Bound Distemper over a coat of primer , complete all as specified and as directed. |
| 7 | M & L for preparing old plastered surfaces of wall and applying one coat of Oil Bound Distemper complete all as specified and as directed. |
| 8 | M & L for preparing new plastered surfaces of ceiling and applying two coats of Oil Bound Distemper over a coat of primer, complete all as specified and as directed. |
| 9 | M & L for preparing old plastered surfaces of ceiling and applying one coat of Oil Bound Distemper complete all as specified and as directed. |
| 10 | Taking down chowkats or frame with shutters (without taking off shutters from the frame), n.exc 1.5 Sqm each complete all as directed. |
| 11 | Taking down chowkats or frame with shutters(without taking off shutters from the frame),exc 1.5 Sqm but n.exc 4.0 Sqm each complete all as directed. |
| 12 | S & F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing, hinges, tower bolts, handle etc. complete all as specified and as directed. |
| 13 | S & F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2Nos in each door, hinges, anodies aluminium snap beading screws etc. complete all as specified and as directed. |
| 14 | S & F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 kg/m including necessary joininig cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and as directed. |
| 15 | S & F aluminium (Die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. |
| 16 | S & F 4mm thick sheet glass, ordinary quality and glaing with oil putty in square n.exc 0.5 Sqm in each pane complete all as specified and as directed. |
| 17 | S & F 4mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 Sqm in each pane complete all as specified and directed. |
| 18 | S & F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed. |
| 19 | S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with 19 x 19mm MS square tube and 1.2mm wall thickness complete all as specified and as directed. |
| 20 | S & F solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail.MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with a solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either sides and as gap inserts for top and bottom rail paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as per specification and drawing complete all as specified and as directed. |
| 21 | S & F Stainless Steel butt hinges 100mm long, medium weight cold rolled, fixed to timber frame work of doors complete all as specified and directed. |
| 22 | M & L extruded aluminium alloy handles 150mm, fabricated type, anodized complete all as specified and directed. |
| 23 | M & L aluminium anodized barrel tower bolt of extruded section length of bolt 150mm complete all as specified and directed. |
| 24 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not hacking), removing serviceable tiles away site and rubbish off the premises complete all as specified and as directed. |
| 25 | M & L screed bed or bedding layer of mortar 15mm thick in cement plaster(1:4) for laying finishes all as specified and as directed. |
| 26 | M & L for non skid coloured ceramic tiles 300mm x 300mm x 7 to 8mm thick in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 27 | M & L for Non - skid /matt finish vitrifiedcoloured tiles 7 to 8 mm thick area of eachtile exc 0.18 sqm but not exc 0.38 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with proper line and level as required on site complete all as specified and as directed. |
| 28 | M & L for non - skid /matt finish vitrifiedcoloured tiles 7 to 8 mm thick area of eachtile exc 0.18 sqm but not exc 0.38 Sqm, in vertical surface Skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with proper line and level as required on site complete all as specified and as directed. |
| 29 | M & L for rendering 10mm thick cement plastered as backing coat of wall on fair surfaces of brick in cement mortar (1:3) to receive wall tiles complete all as specified and as directed. |
| 30 | S & F glazed coloured ceramic tiles 300mm x 450mm x 6 to 7mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 31 | Demolition of cement concrete (un-reinforced) in ground floors and pavingsexc15 cm thickness above ground floors complete all as specified and directed. |
| 32 | M & L for providing 75 mm thick plain cement concrete (1:3:6), type C-2 (using 40mm graded stone aggregate) as in plinth protection/ path Hardstanding etc., complete all as specified and as directed. |
| 33 | M & L for providing 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregates) as in sub basecomplete all as specified and directed. |
| 34 | M & L for factory made PU coated machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with coloured pigments of PVC moulded or Rubber mould with vibrating system with including 50mm thick sand cushining in CM (1:3) in edges of pavers, complete all as specified and directed.(Note: The cost of sand cushion is to be included in the quoted rate) |
| 35 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 36 | M & L for use and waste of timber as in formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exc 200mm thick (Horizontal or sloping)flat rough finished surfaces of concrete complete all as specified and as directed. |
| 37 | M & L for mild steel TMT bars 10mm dia and over cut to length bent to shape required for fixing including cranking bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 38 | M & L for RCC M-30 design mix (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 39 | S & F in repair European type WC (Pedestal Pattern) complete inlcuding pedestal pan and trap including connection to drain, flushing pipe, seat cover (excluding fixing bolt, flushing cistern complete all as spefcified and directed. |
| 40 | S & F in repair PVC valve less, syphonic action type flushing cistern, 10 litres, low level, white with inlet ball valve, float and handle inlcuding brackets complete all as specified and directed. |
| 41 | S & F vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, chain and plug and porcelain stopper but including brackets, waste couplings 32mm dia, cutting for and pinning in ends of brackets or errecting stand complete all as specified and directed. |
| 42 | S & F 32mm size waste couplings of PTMT (half or full threaded) (minimum weight 32mm- 45gms) complete all as specified and directed. |
| 43 | S & F in repairs PVC connections 15mm size 600mm long with PTMT nuts complete all as specified and directed. |
| 44 | S & F in repair Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for 15mm diairon bore pipe and fixed complete all as specified. |
| 45 | S & F in repair angle stop cock 15mm bore, fancy type, chromium plated (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or unions and fixed complete all as specified and directed. |
| 46 | S & F in repairs bib tap 15mm bore, fancy type, cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly screwed for iron and fixed complete all as specified and directed. |
| 47 | S & F towel rail 450mm long of Stainless Steelfixed with and inlcuding chromium plated brass screws and wooden / plastic cleats (minimum weight 170gms) complete all as specified and directed. |
| 48 | S & F 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 49 | Taking up or down steel water tubing and connection 15mm dia complete all as specified and as directed. |
| 50 | S & F steel tubes, medium grade 15mm dia bore galvanized with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 51 | S & F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 52 | S & F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 53 | S & F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 54 | S & F in repairs 75mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 55 | S & F in repairs 40 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 56 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 57 | M & L for PVC (SWR) floor trap with steel grating 75 mm dia including jointing to waste pipe including removing old traps complete all as specified and as directed. |
| 58 | S & F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 59 | S & F mild steel framed work such as grills, gratings, etc.., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 60 | S & F pre-painted corrugated galvalume (55% aluminium + 43.5% Zinc+ 1.5% Silicon) steel sheets as in roofing/ wall cladding, 0.50mm thick (total coated thickness), conforming to AS-1397/ASTM A-792 and having yield strength minimum 550 MPa fixed with self drilling metal coated screw of appropriate size, self taping bolts and fixed as per manufacturers instructions complete all as specified and directed.(Note:The sheet shall be laid with one corrugation side lap and one end lap minimum 150mm all as per manufacturers instructions alongwith wind ties). |
| 61 | S & F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 62 | S & F for Rolled sections Fe-290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins ,post where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 63 | M & L for preparation of new or previously untreated steel surfaces of any description over10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed. |
| 64 | Removing of existing old bituminous tarfelt including cement screed bed and clean the surface with wire brush and washing with water to achieve the original surface of slab incl rubbish off outside of MD land all as specified and directed. |
| 65 | M & L water proofing treatment to RCC roof slab, walls, chhajjas ets, shall be carried out as specified below and as directed by Engineer-in-Charge(a) M&L for 10mm hick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bitumnous primer @ 0.20 Kg/Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyester, weighingnot less than 3.5 Kg/Sqm and 3mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directedby Engr-in-Charge.Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifyingthe same to the entire satisfaction of GE. (d) Applying a coat of solar reflective bituminous aluminiumpaint @ 0.15 ltr/Sqm on the top of membranesurfaces(e) Finally all outer side of membrene to be sealed by waterproofing selant complete all as specifed & as directed by Engr in Charge. |
| 66 | M & L forPCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in PCC padding in roof kerbs or mud stops, rounded and chamfered on edgesand on chajjas laid over RCC surface fineshed even and smooth without using extra cement including necessary water proofing chemicalswith proper line and level as required on site all as specified and directed by the Engr-in-charge.(Note: WPC shall be measured and paid separately) |
| 67 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sq m on plan and n.exc 1.5 m in depth and getting out in any type of soilall as specified and as directed. |
| 68 | M & L for PCC(1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundation complete all as specified and directed. |
| 69 | M & L for precast cement concrete block masonary with solid blocks, type C-1 (1:3:6) (using 20mm graded stone aggregate) exc 10cm in width and set in cement mortar (1:4) all as specified and as directed |
| 70 | S & F prelaminated PVC rigid foam sheet wall panelling of 5 mm thick stuck on inner frame work of 35 mm wide strips of 5 mm thick rigid foam sheet. The strips should have a groove of 6 mm width and 2 mm depth for sinking the head of screw used to fix the strips to the wall and should be placed vertically at equal intervals of 300 mm C/C. The PVC strips to be fixed to the wall using 65 mm long MS screws through the groove in the strip by using PVC fasters incl moulding at columns, windows and doors jambs all as specified and as directed. Note:-(a) Work for fixing of wall panelling shall be got executed through manufacturers authorised applicators only under the close supervision of their technical staff.(b) The entire qty of wall panelling and their allied ancillaries shall be procured directly from the manufacturer or their authorised dealer only. |
| 71 | M & L for 20mmthick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and as directed. |
| 72 | Excavating in post holes in soft disintegrated rock(or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 73 | M & LMS posts and strutsincluding cutting tops to shape as directed, drilling holes, notching for wire,including embeded in concrete all necessary welding, drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 74 | M & L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in hard standing /path , side filleting etcor simillar works all as specified and directed. |
| 75 | S & F stainless steel sink with drainage board made of stainless steel 1 mm thick with plugs washers and waste including bedding in cement mortor or including fixing cantilever brackets and connecting union to pipe overall size 915 mmx 460 mm bowl size 410 mm x 330mm x 160 mm complete all as specified and as directed. |
| 76 | Dismantling of wall panelling/ceilling (fibre, pulp, insulation etc) of any description of any thickness including cover fillets complete all as specified and as directed by Engine-in-Charge. |
| 77 | S & F aluminium anodised snap grid frame (with minimum 15 micron uniform anodic coating) size of 600 x 600 mm consisting of Tee/Angle section, size 40x40x2 mm thick as approved make conforming to IS-733 in frames of false ceiling including aluminium cleats with necessary CP brass/stainless shunk screws.aluminium perimeter angles fixed to wall wooden frame at centre to centre and fixing frame to level adjusting anchors 6 mm dia GI wire hook in Tee members at 1.5 m Centre to Centre fixed to steel truss orroof complete all as specified and directed. |
| 78 | M & L for fixing in position 4 mm thick Non Asbestos designer ceiling board of size 595x595 mm as per manufacturer\"s specification complete all as specified and directed. |
| 79 | E/M PORTIONTaking down old unserviceable point wiring, (light, fan, socket or power) complete including fittings & fixtures such as switch, ceiling rose, pendants, regulator, socket, etc., and making good the disturbed surfaceof wall, floors, ceiling etc to match with the existing including touch up of paint/white wash all as specified and directed by Engineer- in-charge. |
| 80 | M & L for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in wallsby cutting chases using machine and making good the disturbed surface, with and including suitable boxes ,switch plates of suitable make and 1.5 sq mm copper earth continuity wire connected to earth dolly for One light point controlled by one switchcomplete all as specified and as directed. |
| 81 | Description all as per Item No 80.00 above but for One fan/exhaustpoint controlled by one switch complete all as specified and as directed. |
| 82 | Description all as per Item No 80.00 above but for One socket 5 Amps on same board complete all as specified and as directed. |
| 83 | Description all as per Item No 80.00 above but for One socket 5 Amps on independent board complete all as specified and as directed. |
| 84 | Description all as per Item No 80.00 above but for One bell point controlled by one switch complete all as specified and as directed. |
| 85 | Description all as per item No. 80.00 above but with 4 Sqmm cable for 3 pin 15 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 86 | S & Fmodular switch 1 way 6A, 1 module complete all as specified and as directed. |
| 87 | S & F modular switch 1 way 16A, 1 modulecomplete all as specified and as directed. |
| 88 | S & F modular Bell push switch 1 way 6A, 1 module complete all as specified and as directed. |
| 89 | S & F modular socket , 6A-2/3 pin combined 2 module complete all as specified and as directed. |
| 90 | S & F modular socket , 6A/16A -2/3 pin combined 2 modulecomplete all as specified and as directed. |
| 91 | S & F modular cover Plate with Frame 3 modulecomplete all as specified and as directed. |
| 92 | S & F modular cover Plate with Frame 4 modulecomplete all as specified and as directed. |
| 93 | S & F modular cover Plate with Frame 6 modulecomplete all as specified and as directed. |
| 94 | S & F modular metal flush box 3 modulecomplete all as specified and as directed. |
| 95 | S & F modular metal flush box 4 modulecomplete all as specified and as directed. |
| 96 | S & F modular metal flush box 6 modulecomplete all as specified and as directed. |
| 97 | S & F modular Fan regulator 2 modulecomplete all as specified and as directed. |
| 98 | S & F Ceiling rose PVC/ Polycarbonate insulated body with three terminalscomplete all as specified and as directed. |
| 99 | S & F Bell multi music typecomplete all as specified and as directed. |
| 100 | S & F wall mounted LED 18/20 watts with out put of 1800 lumens , boxtype (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4\" x 18 watts including removal old existing unsv tube light fitting complete all as specified and as directed. |
| 101 | S & FEnergy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired andnecessary mounting arrangements , provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and removal old existing unsv tube light fitting complete all as specified and as directed. |
| 102 | Taking down the Ceiling fans of any model, size & sweep carefully from its original position and dismantlingmotor and over hauling complete by cleaning all dust / grease with kerosene or petrol, & replacement of unserviceable bearings, bushes, split pins and nut and bolts and applying new grease for bearings, reassembling the motor and fixing the blades, preparation old surfaces of fan of any sweep & model and painting the with synthetic enamelled paint by spraying including filling cavities and testing and refixing the same complete as directed by Engr in Charge, Note for Item (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis included in unit rate quoted against this Item.(ii). Any unforeseen minor repair and minor parts like Rubber bush, MS Clamps, split pins, base frames, nuts, bolts etc that are covered under this and required to complete the repair work / smooth functioning of Fan Motor shallbe deemed to be included with the unit rate .Transportation of Stator / Rotorparts for machining & rewinding, shaft / bushingfor machining , welding , turning at lathe shop at Port Blair are also deemed to be included with unit rate.iii). Rewinding of stator / rotor of motor, any machine workwhere involved shall be measured and paid separetely against relevant item of this schedule. |
| 103 | Supply only following spares of ceilingfan of any model, size & sweep to incorporate against each Item of Schedule \"A\"here-in-above complete all as specifed & directed(a) Supply only ball bearing suitable for Ceiling fan upto 1400 mm sweep |
| 104 | (b)M&Lforrewinding the motor of Ceiling Fan 1400 mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size & Capacity including,varnishing,drying etc,andrefixingthe stator and rotor perfectly to rotate smoothly and connection alongwith fixing of suitable fan capacitor complete including taking out burned unserviceable copper winding wireall as directed.Note for item (99.00) & (100.00):- Rates for incorporation of new fan capacitor of suitable capacities for smooth runinng of fans are deemed to be inclusive in the quoted rates |
| 105 | M & L for submain wiring withsingle core PVC insulated FRLS multistranded copper conductor cable of size 2 x 4.0 Sqmm drawing into and includingrigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire completeas directed by Engr in Charge .Note : (i) 3 Runs of 4 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 106 | M & Lfor submain wiring withsingle core PVC insulated FRLS multistranded copper conductor cable of size 2 x 6.0 Sqmm drawing into and includingrigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire completeas directed by Engr in Charge .Note : (i) 3 Runs of 6 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 107 | M & L for submain wiring withsingle core PVC insulated FRLS multistranded copper conductor cable of size 4 x 4.0 Sqmm drawing into and includingrigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wirecomplete as directed by Engr in Charge Note : (i) 5 Runs of 4 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 108 | M & L for cutting chases for concealed conduitpoint wiring,sub main wiringand sinkings for boxes but not exeeding 10 cm girth and making good to walls,floors with 1:3 cement mortar and applywhite wash or distempermatching with existing colour as directed by Engr in Charge. |
| 109 | S & F in replacement sheet metal enclosure MCBDBSPN enclosure with a two pin and earth piug and socket complete with one single pole MCB including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed. |
| 110 | S & F in replacement sheet metal enclosure MCBDBTPN4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed. |
| 111 | S & F in replacement sheet metal enclosure MCBDBSPN4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed. |
| 112 | Supply only MCBs of following rating (a) MCB SP 6 to 32 Amps 240V 10 KA.\"C\" Series complete all as specified and as directed. |
| 113 | (b) MCB DP 32 Amps 240V 10 KA.\"C\" Series complete all as specified and as directed. |
| 114 | (c) MCB TPN 63 to 100Amps 415 V 10 KA.\"C\" Series complete all as specified and as directed. |
| 115 | S & F on wall MCCB 63 Amp 415 Volts , Four pole with Sheet steel enclosure for sutable size of MCCB with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands and fixing arrengement on wall ,PCC work including necessary clamps with nuts, bolts & washers andPowder coatedall as specified and directed . |
| 116 | Dismantling and taking out old unserviceable Earthing and M&L for earthing with galvanised steel earth plate electrode 60cmx60cmx6mm burriedearth pit not less than 2.25m depth below normal ground level with to edge of the plate vertically to depth of not less than 1.5 m below ground level connected to & including Galvanised earth wire 4 sqmm by mean of GI bolts & nuts etc with provision of char-coal and salt etc all as per electrical plate No-3 of SSR-2020including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc., complete all as specified and directed by Engineer-in-charge.Note :(i)Refilling of the earth pit shall be carried out with black cotton soil.(ii).GIwire 4.0mm dia & GI protection pipe upto 7.5 m length will be measured under this item.(iii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost |
| 117 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed. |
| 118 | Removing excavated materils (soil) to a distance not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed. |
| 119 | S & L XLPE, insulated, armoured, heavy duty, electric cable of cross sectional area of 4 Core x 25 Sq mm with stranded aluminium conductors, 1100 volts grade, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, with GI protections pipes, complete all as specified and as directed by Engineer-in-Charge |
| 120 | S & F for DWC pipe double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed. |
| 121 | Dismantling existing unserviceable PVC water tanks and supply and fix PVC rotational moulded water tank of 1000 litres capacity two layered hoisted and fixed in position including provision of necessary inlet / outlet / over flow pipe and connected with the existing pipe lines complete all as specified and directed. |
| 122 | S&F tubes, CPVC pipe 25mm dia bore with all fittings and fixed SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 123 | S & F CPVC Gate valve, for CPVC pipe 25 mm bore dia complete all as specified and directed |