| 1 | Supply, installation, testing & commissioningair cooled , split unit air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 1.5 TR, BEE5 Star rated with cooling and intelligent heating facility and Digital Inverter twin rotary including its fixing accessories with following specification: (i ) Rated cooling capacity: 18000 Btu/Hr (ii) Rated Current cooling : 7.8 Amp (iii) Rated heating capacity: 18000 Btu/Hr, (iv) Copressor type: High EER twin Rotary (v) Anti dust/Anti-bacterial Filter, (vi) Dehumidifier (vii) Refrigerant gas: R32, (viii) Operation:Operation: Cordless Remote control unit with self dignosis facility all as specified and directed. Note: The quoted rate shall deemed toinclude powder coated stand (bracket) for fixingoutdoor unit and cutting, chasing of wall/surface and making goodas per existingall as specified and directed. |
| 2 | Supply, installation, testing & commissioning ofdeep freezer of capacity 500 litres,double door with metal top ,single phase,240V ,50 Hz, complete all as specified and directed . |
| 3 | S&Fvoltage stabilizerof capacity 5.0 KVA, copper wound ,wall mounted type for automatic operation, single phase, naturally air cooled ,indoor type & designed for input voltage 170 V to 250 V and output voltage stabilized at 230 Vwith accuracy of ± 2.5%complete all as specified and directed . |
| 4 | Point wiring complete with 2.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid medium grade concealed conduit of suitable size with all accessories such as bend, reducers, MS hooks including modular galvanisedflush boxes of suitable size and white cover plate with frame as per relevant ISfor mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 2.5 Sqmm PVC FRLSH stranded copper conductor unsheathed, insulated, strandedconnected to common earthpoint dolly for one 3 pin socket outlet 15/16 Amp independent complete all as specified and directed . Note:- Proper colour coding is to be followed as per IS specifications. |
| 5 | S&F modular type switch, one way, 16 Amps, 1 module complete all as specifieds and directed . |
| 6 | S&Fmodular type socket 3 pin, 6 A/16 Amps,2 module complete all as specifieds and directed . |
| 7 | S&F 1100 volt grade, heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and overall PVC sheathed in service connections, suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 10 Sqmmcomplete all as specified anddirected. |
| 8 | S&F 1100 volt grade, heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and overall PVC sheathed in service connections, suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 16 Sqmmcomplete all as specified anddirected. |
| 9 | Supply, installation, testing & commissioningair cooled , split unit air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 2.0 TR, BEE5 Star rated with cooling and intelligent heating facility and Digital Inverter twin rotary including its fixing accessories with following specification: (i ) Rated cooling capacity: 18000 Btu/Hr (ii) Rated Current cooling : 7.8 Amp (iii) Rated heating capacity: 18000 Btu/Hr, (iv) Copressor type: High EER twin Rotary (v) Anti dust/Anti-bacterial Filter, (vi) Dehumidifier (vii) Refrigerant gas: R32, (viii) Operation: Cordless Remote control unit with self dignosis facility all as specified and directed. Note: The quoted rate shall deemed toinclude powder coated stand (bracket) for fixingoutdoor unit and cutting, chasing of wall/surface and making goodas per existingall as specified and directed. |
| 10 | Supply, installation, testing & commissioningof window type room air conditioner, electric driven, AC, 230 V, 50 Hz, single phase of capacity 1.5 TR (4500 K cal per Hr) , BEE5 Star rated with cooling and intelligent heating facilityincluding its fixing accessories with following specification: (i) Anti dust/Anti-bacterial Filter, (ii) Dehumidifier (iii) Refrigerant gas: R22/R32, (iv) Operation: Cordless Remote control unit with self dignosis facility all as specified and directed. Note: The quoted rate shall deemed toinclude grill/wood cutting extra copper wire,stand and other accessorirs all as specified and directed. |
| 11 | S&Fsheet metal enclosure with socket plug top and MCBs DP 20 Amp, 240 V, AC Supply, Single Pole and neutral enclosure with a two pin and earth plug with socket complete all as specified and directed |
| 12 | S&FSheet metal enclosure for DBs,SPN, double door,IP-43 protected, 415 Volts,4 ways with 100 amps rated copper bus bar complete all as specified and directed |
| 13 | S&FSheet metal enclosure for DBs,SPN, double door,IP-43 protected, 415 Volts,8 ways with 100 amps rated copper bus bar complete all as specified and directed |
| 14 | S&F factory made epoxy polyester powder coated distribution board TP&N ,6 ways (VTPN DB), double door,(concealed flush to wall) (IP-43 protection) fabricated from minimum 1.2 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 250 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with space for provision for 4 pole MCCB as incommer and outgoing MCBs as required at siteand conforming to IS: 8623 along with cable end box including making good disturbed surface complete all as specified and directed.NOTE: (a) MCCBs and MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/ sleeves and its cost shall be deemed to be included under respective item of BoQ. |
| 15 | S&F MCB SPN, 40-63 Amp, 240 Volts withrupturing capacity 10 KA, \"C\" series, complete all as specifieds and directed . |
| 16 | S&F MCB Single pole, 6 to 32 Amp, 240 Volts withrupturing capacity 10 KA, \"C\" series, complete all as specifieds and directed . |
| 17 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified anddirected. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 18 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth in any type ofsoilfor laying of cables, pipes etc. and getting out complete all as specified and directed . |
| 19 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed. |
| 20 | Removing excavated material or surplus soil to a distance not exc 50 meter and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed . |
| 21 | M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment. |
| 22 | M&L for factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dryin trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. |
| 23 | S&FSubmain wiring with two runs of single core PVC FRLSH unsheathed, insulated, copper cable of 6 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathedFRLSH copper wire 6 Sqmm for continous earth wire drawn into and includingconcealed PVC conduit of suitable sizecomplete all as specifiedand directed . Note :- Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length) |
| 24 | S&FSubmain wiring with two runs of single core PVC FRLSH unsheathed, insulated, copper cable of 4 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathedFRLSH copper wire 4 Sqmm for continous earth wire drawn into and includingconcealed PVC conduit of suitable sizecomplete all as specifiedand directed . Note :- Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length) |
| 25 | M&L for complete earthingwith galvanised mild steel earth plate electrode of size600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, precast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh ,15mm dialight grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specifieds and directed .. |