| 1 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr deep in soft/loose soil and getting out for taking down/laying cables of any description and in any position, complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr deep in hard/dense/rocky soil and getting out for taking down/laying of cables of any description, complete all as specified and directed. |
| 3 | Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 4 | Removing excavated materials to a distance not exceeding 50 Mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed. |
| 6 | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 Core, ISI marked as per IS 7098 (Part-I)in trench/floor/on pole/wall complete all as specified and directed. |
| 7 | All as per item No. 6.00 above but for 16 Sqmm 4 Core, complete all as specified and directed. |
| 8 | All as per item No. 6.00 above but for 25 Sqmm 4 Core, complete all as specified and directed. |
| 9 | All as per item No. 6.00 above but for 50 Sqmm 3.5 Core, complete all as specified and directed. |
| 10 | All as per item No. 6.00 above but for 95 Sqmm 3.5 Core, complete all as specified and directed. |
| 11 | All as per item No. 6.00 above but for 150 Sqmm 3.5 Core, complete all as specified and directed. |
| 12 | Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameterwith IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed. |
| 13 | All as per item No. 12.00 above but for outer diameter 90mm, complete all as specified and directed. |
| 14 | All as per item No. 12.00 above but for outer diameter 120mm, complete all as specified and directed. |
| 15 | Supplying and fixing in repair MCCB 125 Amps,4 Pole, 50Hz ,Icu= 25 KA at 415 volts, with thermal magnetic release & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)complete all as specified and directed. |
| 16 | Supplying and fixing in repair MCCB 100 Amps, 4 Pole, 50Hz ,Icu= 16 KA at 415 volts, with thermal magnetic release & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)complete all as specified and directed. |
| 17 | Supplying and fixing in repair MCCB 63 Amps, 4 Pole, 50Hz ,Icu= 16 KA at 415 volts, with thermal magnetic release & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)complete all as specified and directed. |
| 18 | M&L in replacement Copper strip 32 x 6mm for connection of cable to the studs of transformer HV/LV, complete all as specified and directed. |
| 19 | M &L for3M Scotchlite Reflective Tape of width 50 mm, water proof for alternate layer of yellow and black tape 300 mm from bottom of pole 1.5 mtr above, compete allas specified and directed. |
| 20 | M &L for writing/PVC Venyle stickers pole Nos on street light poles with background yellow and Nos in black on yellow oval shaped compete allas specified and directed. |
| 21 | Supplyin replacementpost top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp compete allas specified and directed. |
| 22 | Supplyin replacementpost top lantern with E27 lamp 9 watt, 230 volts (warm white) AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant, Colour rusting, product dimension 230mmc500mm made of metal & Glass,complete all as specified and directed. |
| 23 | Supply and fix in replacement of Tiranga Led Rope Light Indian Tricolor Strip Light (Orange + White + Green) Colour in Single Strip | Independence Day/Republic Day Rope Light for complete 9 meter pole (SP-31), Plug and Play Waterproof IP65 Strip Light, Complete with driver and all fixing arrangements, complete all as specified and directed |
| 24 | Supplying and fixing 1100 volts grade heavy duty cablePVC insulated aluminiumconductor, 4 sqmm 2 core , served with innersheathing of PVC tape and overall PVC sheathed in service connections, complete all as specified and as directed. |
| 25 | Supplying and fixing 1100 volts grade heavy duty cablePVC insulated aluminiumconductor, 10 sqmm 2 core , served with innersheathing of PVC tape and overall PVC sheathed in service connections, complete all as specified and as directed . |
| 26 | M&L for preparing surfaces for paining of LT Panel of any type and any size of any sizes and cleaning of dust/spider webs from panels by air compressor complete and applying One coat ofprimer and two coat of paint (Colour to be approved by Engr-in-Charge). complete all as specified and directed. |
| 27 | Supply,install, testing and commissioning of factory made Smarty - Automatic Power Factor Correction Panel OF Rating 100 kVAr / 415 V APFC Panel CYCAP (Capacitor Panel) Outdoor type with MCCB of capacity 160A / 25 KA, Rated Voltage 415 Vac, 3ø, 50 Hz, Delta Connection, Super Heavy Duty Cylindrical Capacitor as per IEC: 61921 / IS: 16636, Stages comprises of 4x20 kVAr + 1x10 kVAr + 1x5 kVAr + 1x3 kVAr + 1x2 kVAr,complete all as specified and directed. |
| 28 | Supply, installation and testing of chemical earthing in specially developed Tripod system consisting of 3 Nos of chemical earthings equally spaced at a distance as per IS 3043 & IEEE80 with each earthing consisting of 99.9% copper earthing electrodes, minimum outer dia 50mm, 3 mtr long pipe with internally high grade earth enhancement chemical filling compound to provide better conductivity to rod, not less than 50 Kgs high grade earthing compound to provide earthing value less than one ohm and connecting entire tripod earthing system with 32 x 6 mm copper strip complete, earh enhancement compound suitable for all soil conditions to increase the life of the earthing electrodes non toxic, non reactive non explosive and environmently freindly including complete all as specified and as directed. Note : The quoted rate includes the following(i) Auguring or boring a hole of 4-6 inches in diameter to a suitable depth of not less than 3 mtr.T&P required for auguring or boring complete.(ii) Placing of electrode in a center of pit(iii) Mixing an earth enhancement compound in a bucket and make slurry.(iv) Pouring that slurry in a hole surrounding the rod.(v) Providing 99.9% copper earth electrode.(vi) Connecting the copper strip with the copper busbar mounted on insulator(vii) Providing a earth pit & pit cover on the installed earthing.(viii) 32 x 6 mm copper strip upto test terminal block. |
| 29 | Supply and lay in replacement of GI tube medium grade 40mmsize as in cable protection pipe including all fittings, including FI clamp for fixingcomplete all as specified and directed. |
| 30 | Supply and fix in replacement of MCCB sheet metal Enclosure forupto 250 Amps alongwith necessary fixing arrangements. Complete all as specified and directed |
| 31 | Supply, fixing and testing in replacement of Automatic Street light Timer Switch using combination ofNATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitable power contractor, MCB and support terminals should be enclosed in pole/ wall mountable SMC enclosure made out of Rust proof, Electric shock proof, termite proof and FR grade SMC junction Box conforming to IP 54 protection of capacity 12 KW 3 phase, current range 40 Amps, 4 wire (3 separate power contactor) including all accessories and fixing arrangement all as specified and directed. |
| 32 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection.LED and driver should be BIS certified complete all as specified and directed. |
| 33 | Supply and fix in replacement of Galvanized octagonal decorative poles (6.0 meter long) ISI marked complete withbase plate and finial taper plug, nuts and bolts including foundation and coping complete all as specified and directed. |
| 34 | Supply and fix in replacement of Galvanized octagonal decorative poles (8.0 meter long) ISI marked complete withbase plate and finial taper plug, nuts and bolts including foundation and coping complete all as specified and directed. |
| 35 | Supply and fixing of smart integrated 30 Watt Smart Bright, All in one Solar Street Light, including suitable hanging bracket, Overcharged & deep discharge protection for battery, MPPT solar charge controller, LiFeP04 lithium Ferro Phosphate battery, maintenance free system, inbuilt BMS system, IP-65, lumen output≥ 1500 Lm, Colour temp 5700K, Surge protection 5 KV, 50000 burning hrs (min), including nuts, bolts, washers, complete all as specified and directed. |
| 36 | Supply and fixing in replacement new generation, energy saving and environmental friendly long life LED Floodlight fitting of 200 watt made up ofpressure die-cast aluminium housing with high power LEDs as lightighting source and lens embedded,electronic driver type , IP 66 complete all as specified and directed. |
| 37 | Supply and fixing in replacement new generation, energy saving and environmental friendly long life 100 watt LED Flood (Cool white/warm white/RGB)light made up ofpressure die-cast aluminium housing with high power LEDs as lightighting source and lens embedded,electronic driver type , IP 66 complete all as specified and directed. |
| 38 | Supply & Fixingin replacement LED Bollard fittings (Inverted Puramid Tripod type), LED 10 W (warm white colour) IP66 protection ratedLED Bollard with opal acrylic diffuser and with soft 360 deg light distribution, 230V, 50 Hz alongwith suitable connectors compete allas specified and directed. |
| 39 | Supply and fix in repair Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 to 240 Sq mm complete all as specified and as directed. Note :- Any Excavation and earth work , Returning and filling, Removing involved shall be included in quoted rate. |
| 40 | All as per item No. 62 but cable size 70 - 95 sq mm cable size complete all as specified and directed |
| 41 | All as per item No. 62but cable size 16 - 50 sq mm cable size complete all as specified and directed |
| 42 | M&L for Servicing of 25 to 62.5 KVA DG Setof make Mahindra/Ashok Leyland / Cummins/Kirloskar) includinggreasing of nipples, draining of unserviceable engine oil by unscrewing drain plug (Engine oil shall be measeured and paid seperatly in respective item) cap, and other moving parts of engine and alternator as per manufacturer’s instructions opening cleaning and re connecting of battery terminals and apply petroleum jelly, checking of coupling and replace it if required, Checking of engine oil leakage if any by replacing gasket, tightening of all nuts and bolts etc, removing radiator completely and cleaning as per manufacturer instructions and refitting the same , check the tightness of fan belts if found loose to be tightened. draining of water accumulated in filter or separate in fuel line including complete fuel tank drying and cleaning re filling of drain out fuel, checking of all electric connections in AMF & LT panel board , switches and contactors etc, checking of free rotation of fly wheel/ shaft of generator and testing to the satisfaction of Engr-in-Charge complete all as specified and directed. |
| 43 | S&F in replacementMCXpower contactor 63 Amps,standard coil voltage 220V,240V and 415 V,50 HZ complete all as specified. |
| 44 | M&L for Lubricant oil15/20W 40 complete all as specified and directed. |
| 45 | Supply and fixing in repair retro reflective boards in shape of rectangle of size1.0 m x1.4 m made out of 2 mm thick stainless steel both side bounded/pasted with high prismatic (iv) sheet mannufactured by avery dennison or 3M with desired letters/logos designed as directed the board shall be supplied with and including stainless steel frame made out of 25 mm dia pipe in frame around duly welded with and including stainless steel sheet and stainless steel posts of 38 mm dia and full lengthof 2.20m one side and 2.8 m other side complete all as specified and directed. ( Note :(i) Rate for fixing of boards with PCC 1:2:4type B2 filling of size 45x45x60 cm to be incl in unit rate. (ii) The board should be written description as direction given by Engr-in-Charge) |
| 46 | Material and labour for PCC Type D2 ,1:3:6by using ( 40 mm aggregatestone aggregate)upto 60 cm in height, copings, rooad cutting filling, complete all as specified and directed. |
| 47 | Supply and fix 1100 Volts grade Copper conductor, PVC insulated, round sheathed (flexible), industrial cable, 0.50 sqmm 3 core complete all as specified and directed. |
| 48 | Supply and fix in repair LED driver for 45-70W LED street light fittings complete all as specified and as directed. |
| 49 | S&F in replacement onload changeover switch 250 A, 4 pole, 415 V alonwith metal sheet metal enclosure including fixing arrangements on wall or with angle iron and pcc work with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories completeall as specified and directed. |
| 50 | Material and labour for testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1.1 KV LT cables of differentsizesfrom both ends, removal of Fault,Re-connections and testing of cables after removal of fault complete all as specified and directed.Notes : (i) All T&P and other acceseries required for checking and findingof fault in cable shall be provided by the Contractor(ii) Charges/rentof the fault locating mobile machine, operator, engineer, electricians etc shall be deemed toincluded rate quoted by Contractor.(iii)Checking and finding fault upto 03 places of same route of the cable will be considered as one Job |
| 51 | Cleaning of sub station area by uprooting all types vegitation,shrubs, weeds, saplingsand creepers of unwanted trees complete with the help of spade,axes, crowbars andother mechanical means after taking necessary electrical shut down from concerned incharge of various sub stns of Military stn Kamptee and Fort Area nagpur complete all as specified and as directed. |
| 52 | M&L for replacement of Bollard light base made of PCC Block (300mmx300mmx300mm) including disconnecting of cables from bollard light and reconnecttion after replacement of PCC Block, complete all as specified and directed Note: 3 phase Connector to be measured and paid seperately |
| 53 | Supply and fix in replacement of Terminal Junction Box With 4 Terminalupto 10 Sqmm, 4 core XLPE UG Cable of size 100 x 100 x 80 mm, IP-65 protection Fitted PG 13.5 Glands and 10 Sqmm Terminals, ABS Material for Outdoor Applications, Terminal Junction Box, PVC Gland 13.5 – 2x, IP67 water proof terminal box junction box suitable for internal connections and joints.Pre fitted PVC Glands PG13.5 (2x) and 10 sqmm terminals (4x) on 35mm Din Rail.Silicon Sponge O-ring with Nylon Screws, complete all as specified and as directed. |
| 54 | Supply and fixing MCB TPN 40-63 Amp rating 415V, 10KA \"C\" curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 55 | M&L and T&P for disconnecting of LT Panel/DG Set connection, shifting, installing, testing and commissioning of LT Panel/DG Set of any capacity from one location to other location in the Nagpur Area inclduing PCC fdn and all fixxing accessoires, complete all as specified and directed Note: Cost of materials required for connecting, commissioning and testing of LT Panel/DG Set shall bedeemed to be included in quoted rate. |
| 56 | Supply, installation, test and commissioning of LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired,outdoor cubicle type, vermin proof, dust proof, fixed on 50x50x5mm MS angle iron frame fixed 600mm above ground level and 400mm below the ground level grouted in and including PCC 1:3:6 type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm thick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy RAL 7032 siemen grey colour after seven tank phosphating treatment from inside and outside with locking arrangement, front and back opening type and fixing arrangement i.e nuts, bolts, washers, clamps etc, withnaturally air cooled epoxy insulated aluminium busbar TPN with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, all control cablesshall be of 2.5 Sqmm coppermulti stranded conductors and shall be properly bunched withsuitable size binding materials , ferruled for proper identification of colour codes and crimped with adequate size of lugs also to accommodate,fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and consisting of the following items, including taking down the old unserviceable LT Panel/feeder pillar of any size/ any type,all as specified and as directed.Contd../- |
| 57 | Contd..56/-Note : (i) Make of ACB/ MCCB :- Legrand / Lauritz Knudsen Electrical and Automation / C&S / ABB(ii) Make of LT panel:- Rashan Engg / Shalabh (India) Limited / Legrand / Mclayers Mercantile Pvt Ltd /Lauritz Knudsen Electrical and Automation (iii) LT Panel board should be CPRI approved as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining aproval from GE). (iv) SLD diagram for LT Panelwill be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (v) Rate for the same deemed to include in the quoted rates.Location : Near Class room bldg, Army Public Schoolcomprising of the following :-(a) Busbar chamber for 3 phase & nuetral of capacity 800 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve.(b)Multifunctioning meter to measure Voltage, Ampere, KWH,PF - 01 Nos (c) One set of pilot lamp.(d)Incoming MCCB 400 Amps 4 Pole,415 volts withIcu=50 KA ,Ics = 100% ofIcu,with adjustable type overload setting (Min 70% to 100%) - Qty - 01 Nos. (e) Outgoing MCCB, 4 polehaving current ratings 100 Amps, AC 415 Volts, withIcu=36 KA,Ics = 100% ofIcu,with adjustable type overload setting (Min 70% to 100%) - Qty - 01 Nos. |
| 58 | Contd..56/-(f)Outgoing MCCB, 4 polehaving current ratings 63 Amps, AC 415 Volts, withIcu=25 KA,Ics = 100% ofIcu,with adjustable type overload setting (Min 70% to 100%) - Qty - 04 Nos.(g)Outgoing MCB, 4 pole having current ratings 63 Amps, AC 415 Volts, withIcu=25 KA,Ics = 100% ofIcu,with adjustable type overload setting (Min 70% to 100%) - Qty - 04 Nos. |
| 59 | All as peritem No. 56 here-in-before but comprising of the following :-Location : GE Office Complex / AGE E/M Office(a)TPN 04 Nos aluminium busbar in equal size 3 phase and neutral 300 Amp rating duly insulated fitted on heat shrinkable insulation and covered with colour sleeve.(b)Auto Transfer Switch 160 Amps, FP - 01 Nos(c) Incoming MCCB 160 Amp 36 KA, 415 V, FP - 03 Nos.(one standby for main, one working for mains and one working for DG Set, standby and working for mains should be connected with suitable capacity of aluminium busbar).(d) Outgoing MCCB 63A, 25 KA, 415 V, FP - 02 Nos(e) Outgoing MCB TPN 40 Amp, 16 KA, 415 V, FP - 01 Nos (f) Outgoing MCB TPN 32 Amp,C curve, 16 KA - 01 Nos(g) Outgoing MCB SPN 32 Amp, C curve, 10 KA - 02 Nos(h) Multifunction meter for measure, current in Amp, Voltage (both phase wise) and Frequency, PF-01.(j) LED Indicator lamp - 05 Set of Three. (Three for phases, one for Load on mains and one for Load on DG) |
| 60 | Supply, install, test and commissioning in replacement of factory fabricated APFC panel board cubicle outdoor type made out made out of CRCA sheet 3.00 mm thick for outer shell and 2mm thick for inner shell duly powder coated paint with inner shutter & outer double door, the cubical shall have a bottom channel of size 75x40x5mm duly coated with zinc metal coating with Stainless Steellocking handle arrangement with Neoprene gasket, both side openable fixed on 50 x 50 x 5 mm MS angle frame fixed 300mm above groud level & 450mm below the ground grouted in & including PCC 1:3:6 type C1 (using 20mm graded stone aggregate) . The panel shouuld be made for outdoor type automatic power factor from 0.8-0.99 minimum, \"ready to use design and suitable for 415 V, 3 Ph, 50 Hz AC, with MPP-H type cap. Banks, microprocessor based controller suitable for intelligent energy management with its unique features of four quadrant operation, automatic C/K ratio selection, auto disconnection of capacitors in case of power failure and auto connection of capacitors on resumption of power supply with time display of power factor with indication whether it is lagging or leading besides provision for automatic lock out of faulty steps etc, housed in elegant and highly functional enclosures of modular design complete all as specified, directed & comprising of following including refixing existing cables to new panels by proper lugging & cable gland as required in all respect as directed.Contd../- |
| 61 | Contd..58/-comprising of the following :- (a)APFC panel 240 KVAR panelwith Incommer MCCB 400 Amps, 50 KA, 4 pole, contactor suitable for capacitor rating &MPP-H capacitor banks.The APFC controller should have Auto on/offcapacitor banks in the step of (5x1+10x1+25x1+50x4) KVAR MPP-H capacitor banks rating and accessories are as under :- i) Power capacitor for two branch 01 No of capacity 5 KVAr eachii) Power capacitor for two branch 01 No of capacity 10 KVAr eachiii) Power capacitor for two branch 01 No of capacity 25 KVAr eachiv) Power capacitor for three branch 4 Nos of capacity 50 KVAr eachv) Switching device for 2 KVAr capacitor Branch = MO C5 (1 NO aux contacts for each branch)vi) Switching device for 3 KVAr capacitor Branch = MO C 20 (1 NO aux contacts for each branch)vii) Switching device for 5 KVAr capacitor Branch = MO C15 (1 NO aux contacts for each branch)viii) Switching device for 10 KVAr capacitor Branch = MO C12.5( 1 NO aux contacts for each branch)ix)Switching device for 20 KVAr capacitor Branch = MO C12.5( 1 NO aux contacts for each branch)x) Accessories for switching device = 1 Normally closed + normally opened side add-on lock for each Branchxi) protection for each branch tripple pole MCB of rating not less than 2 times the charging current of indiusal stage. xii) APFC microprocessorController= 5 Star APFC Relay |
| 62 | M&L for Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burrieddirectly in groundverticallyto a depth not less than 2.5 metrebelowgroundlevelwith topedgeof theearth plate at a depth not less than 1.5 mtr belowgroundlevelearth platesurrounded from all sides by 15cmthickpacked layer ofcharcoal dust and common saltfillinginalternate layers andelectrodeconnectionby usingearth strip 25 x 4 mm by meansof bolts, nuts, check nutsand washersmade of galvanised ironand thimbles and other endof theearth wire connectedto mainswitch boardprotected by galvanised iron medium grade pipe 40mm borein wall/floor/andGI Pipe 20 mm borelight grade forwatering with funnel and wiremesh PCC chamber in cementconcrete 1:3:6 typeC-2 and RCC pitcover includingnecessaryexcavation andearth work in anytype ofsoil, returningslurry approved soil and disposed of surplussoilto adistancenotexceeding 50 Mtraway all as shown inelectrical plateNo 3ofSSR 2009 ( Part-I).Notes for srl Item No. 3.06 & 3.07.(a)The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.Contd../- |
| 63 | Contd..59/-(b) PCCpit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthingwork is not found satisfactory then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d)Earthing work will be carried out in presence of MES representative. |
| 64 | NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.)[(-) Rs. 35,528.00] |