| 1 | M&L for Servicing of 200 KVA DG Set, includinggreasing of nipples, draining of unserviceable engine oil by unscrewing drain plug (Engine oil shall be measeured and paid seperatly in respective item) cap, and other moving parts of engine and alternator as per manufacturer’s instructions opening cleaning and re connecting of battery terminals and apply petroleum jelly, checking of coupling and replace it if required, Checking of engine oil leakage if any by replacing gasket, tightening of all nuts and bolts etc, removing radiator completely and cleaning as per manufacturer instructions and refitting the same, check the tightness of fan belts if found loose to be tightened. draining of water accumulated in filter or separate in fuel line including complete fuel tank drying and cleaning re filling of drain out fuel, checking of all electric connections in AMF & LT panel board, switches and contactors etc, checking of free rotation of fly wheel/ shaft of generator and testing to the satisfaction of Engr-in-Charge, complete all as specified and directed. Installed at MH Kamptee, Treated water pump house, Radial well. |
| 2 | All as per item No 1 above but DG Set of 180 KVA installed at AC plant MH, complete all as specified and as directed. |
| 3 | All as per item No 1 above but DG Set of 120 KVA installed at Unit 371 Trg Area, complete all as specified and directed. |
| 4 | All as per item No 1 above but DG Set of 100 KVA installed at Record Office GRC, Auditorium GRC, Station Exchange GRC, Tagore Hall NCC OTA, complete all as specified and directed. |
| 5 | All as per item No 1 above but DG Set of 58.5 KVA to 63 KVA (Installed at Shivaji Pump House, APS Tech Block, Tele Exchange Unit 371, HQ UM & G Sub Area Nagpur, MH Dental). complete all as specified and as directed. |
| 6 | All as per item No 1 above but DG Set upto 30 KVA to 40 KVA (installed at APS record, HQ UM & G Sub Area Nagpur (Near AFI Bldg), Fort Area Nagpur (Near GOC House), 299 Area Pump House, CWE Office Nagpur, NCC OTA , STP GRC). complete all as specified and as directed. |
| 7 | All as per item No 1 above but DG Set of 25 KVA installed at \"R\" Line Pump House, \"T\" Line pump house,R line STP .complete all as specified and as directed. Notes for Item No 01 to 6 above:-Rate quoted by Contractor shall deemed to be included following provisions:-(a)Sufficient/required man power employed for the servicing purpose, T&P used and other petty items such as cotton waste kerosene oil, nuts and bolts etc and any ther minor items. (b)replacement of spares will be measured and paid separately as supply only under respective items.(c)If any defect observed during defect liability period the same shall be rectified by contractor without any extra cost to the Govt. The Contractor shall visit each DG Set prior quoting the rate to know the current status of respective DG Sets.No claim what so ever on this account shall be entertained whether he visit the DG set or not. |
| 8 | Supply and fix in replacement automatic voltage regulator (AVR) suitable for the DG Set 25 KVA to 120 KVAcomplete all as specified and directed. |
| 9 | Supply and fix in replacement automatic voltage regulator (AVR) suitable for the DG Set 180 KVA to 200 KVA complete all as specified and directed. |
| 10 | S&F in replacement MNX - A1 contractor suitable for DG set complete all as specified and as directed. |
| 11 | S&F in replacement MCX03 contractor 32 Amp, 4 pole, 415 Volt suitable for DG set complete all as specified and as directed. |
| 12 | S&F in replacement MCX04 contractor 40 Amp, 4 pole, 415 Volt suitable for DG set complete all as specified and as directed. |
| 13 | S&F in replacementMCX12 contractor 63 Amp,4 pole, 415 Volt suitaqble for DG set complete all as specified and as directed. |
| 14 | S&F in replacementMCX13 contractor 80 Amp,4 pole, 415 Volt suitaqble for DG set complete all as specified and as directed. |
| 15 | S&F in replacementMNX95 contactor 95 Amp, 4 pole, 415 Volt suitable for DG set complete all as specified and as directed. |
| 16 | S&F in replacementMCX32 contactor 160 Amp, 4 pole, 415 Volt suitable for DG set complete all as specified and as directed. |
| 17 | S&F in replacement MNX300 contactor 300 Amp, 4 pole, 415 Volt suitable for DG set complete all as specified and as directed. |
| 18 | S&F in replacement MCX43 contactor 400 Amp, 4 pole, 415 Volt suitable for DG set 200 KVA complete all as specified and as directed. |
| 19 | S&F in replacement of unserviceable contactor coil of power contactor MCX32, voltage 415 Volt at 50 Hzcomplete all as specified and as directed. |
| 20 | S&F in replacement of unserviceable contactor coil of power contactor MNX 95, voltage 415 Volt at 50 Hzcomplete all as specified and as directed. |
| 21 | S&F in replacement of unserviceable contactor coil of power contactor MNX 300, voltage 415 Volt at 50 Hzcomplete all as specified and as directed. |
| 22 | S&F in replacement of unserviceable contactor coil of power contactor MCX 43, voltage 415 Volt at 50 Hzcomplete all as specified and as directed. |
| 23 | Material and labour for taking down old unserviceable Alternator from DG set 25 KVA to 100 KVA, for rewinding of stater, armature and refixed to the existing position after rewindinding, including replacement of suitable size bearing complete all as specified and as directed. Note : M&L for rewinding with existing size copper wire will be paid under separate item only |
| 24 | Material and labour for taking down old unserviceable Alternator from DG set 120 KVA to 200 KVAfor rewinding of stator, armature and refixed to the existing position after rewinding, including replacement of suitable size bearing complete all as specified and as directed. Note : M&L for rewinding with existing size copper wire will be paid under separate item only |
| 25 | M&L for Rewinding of stater,armaturewith copper wireof same gauge and sizeof25 KVAto200 KVA, DG Set complete all as specified and as directed. |
| 26 | Material and labour for taking downunserviceable self starter from DG set of capacity 25 KVA to 100 KVA 12V, for complete replacement andrefixed to the existing position after rewinding, including replacement of suitable size bearing complete all as specified and as directed.Note : M&L for rewinding with existing size copper wire will be paid under separate iteme only. |
| 27 | Material and labour for taking downunserviceable self starter from DG setof cap 120 KVA to 200 KVA 12V, for complete replacement and refixed to the existing position after rewinding, including replacement of suitable size bearing complete all as specified and as directed. |
| 28 | Material and lablour for taking down radiator of DG set of capacity from 25 KVA to 63 KVA at site and cleanning its fins externaly by air pressure and washed internaly by cleaning agent carefully and fiixing its original position after checking any leakage complete all as specified and as directed. |
| 29 | Material and lablour for taking down radiator of DG set of capacity from above 100 KVA to 200 KVA at site and cleanning its fins externaly by air pressure and washed internaly by cleaning agent carefully and fiixing its original position after checking any leakagecomplete all as specified and as directed. |
| 30 | Supply and fixin replacement lubricant oil filter element with washer suitable for DG set of capacity from 25 KVA to 120 KVA complete all as specified and as directed. |
| 31 | All as per item No 30 above but DG Set of 180 KVA to 200 KVA complete all as specified and as directed. |
| 32 | M&L radiator coolant concentrate complete all as specified and directed. |
| 33 | M&L in replacement fuel filter element with \"O\" ring suitable for DG Sets 100 KVA to 200 KVA complete all as specified and as directed. |
| 34 | All as per item No 33 above but for DG Set of capacity 25 KVA to 63 KVAcomplete all as specified and as directed. |
| 35 | M&L for Lubricant oil15W 40 complete all as specified and directed. |
| 36 | S&F battery connection copper lead with 200 Amps rated capacity of approved make complete all as specified and as directed. |
| 37 | M&L for distilled water in supplier\"s packing complete all as specified and as directed. |
| 38 | S&F battery terminals as per sample complete all as specified and as directed. |
| 39 | M&L for rubber hose pipe complete of suitable sizes for DG sets 25 KVA to 63 KVA complete all as specified and as directed. |
| 40 | M&L for rubber hose pipe complete of suitable sizes for DG sets 100 KVA to 200 KVA complete all as specified and as directed. |
| 41 | M&L for fan belt as per sampler for dynamo/ alternator of suitable sizes for the following DG sets:- |
| 42 | DG Set 180 KVA to 200 KVAcomplete all as specified and as directed. |
| 43 | DG set 120 KVAcomplete all as specified and as directed. |
| 44 | DG set 100 KVA complete all as specified and as directed. |
| 45 | DG set 62.5 KVA to 63 KVA complete all as specified and as directed. |
| 46 | DG set 40 KVA complete all as specified and as directed. |
| 47 | DG set 25 KVA to 30 KVA complete all as specified and as directed. |
| 48 | M&L for fuel pipe heavy duty, suitable size for the DG Set 20 KVA to 200 KVA complete all as specified and as directed. |
| 49 | M&L for air filter complete of suitable sizes for DG Set 180 KVA to 200 KVA complete all as specified and directed. |
| 50 | All as per item No 43 above but for DG Set 120 KVA complete all as specified and directed. |
| 51 | All as per item No 43 above but for DG Set 30 KVA to 100 KVAcomplete all as specified and directed. |
| 52 | All as per item No 43 above but for DG Set 25 KVAcomplete all as specified and directed. |
| 53 | Supply and in replacement fix steel hinges suitable for DG set doors complete all as specified and as directed. |
| 54 | S&F in replacement, indicator lampLED type complete all as specified and as directed. |
| 55 | S&F in replacement, voltmeter with selector switch complete all as specified and as directed. |
| 56 | S&F in replacement,ammeter complete all as specified and as directed. |
| 57 | Material and labour for replacement of Digital Meter indicating hrs run, PF, Voltage, Ampers, Energy consumed complete all as specified and as directed. |
| 58 | Material and labour for replacement of radiator cap with rubber gasket |
| 59 | S&F in replacement unserviceable canopy door lock suitable for all type and sizecomplete all as specified and as directed. |
| 60 | S&F broken door glases of DG set canopy complete all as specified and as directed. |
| 61 | Material and labour for replacement of Ignition/ Starter Switch with Key complete all as specified and as directed. |
| 62 | Material and labour for replacement of water temperature meter gaugecomplete all as specified and as directed. |
| 63 | Material and labour for replacement of oil pressure gauge meter complete as per existing specification. |
| 64 | Material and labour for replacement of fuel tank cap with locking arrangement complete all as specified and as directed. |
| 65 | S&F in replacement BatteryLead Acid cell 12 V, 180 AH (for DG set). complete all as specified and as directed. |
| 66 | S&F in replacement BatteryLead Acid cell 12 V, 150 AH (for DG set). complete all as specified and as directed. |
| 67 | S&F in replacement BatteryLead Acid cell 12 V, 120 AH (for DG set). complete all as specified and as directed. |
| 68 | S&F in replacement BatteryLead Acid cell 12 V, 100 AH (for DG set). complete all as specified and as directed. |
| 69 | S&F in replacementcontroller displaysuitabe forDG setof capacity 25 KVA to 200 KVA complete with all accessories and all as specified. |
| 70 | S&F in replacementrelay 12 Vfor AMF panel complete all as specified and as directed. |
| 71 | S&F in replacementbattery charger12 V (SMPS)for DG set complete all as specified . |
| 72 | S&F in replacemet voltage stablizer 0.5 KVA suitable for DG set complete with all accessories and all as specified. |
| 73 | S&F in replacemet panel box lock complete all as specified and as directed. |
| 74 | S&F in replacement 24 V play relay suitable for DG set complete all as specified and as directed. |
| 75 | S&F in replacementNONC suitable for DG set complete all as specified and as directed. |
| 76 | S&F in replacement battery charger 24 V ( SMPS) complete all as specified and as directed. |
| 77 | S&F in replacement VMR for AMF panel complete all as specified and as directed. |
| 78 | S&F in replacement selector switch complete all as specified and as directed. |
| 79 | S&F in replacement Isolator63 Amp 4 pole complete all as specified and as directed. |
| 80 | S&F in replacemet CT Suitable for DG set 25 KVA to62.5/ 63 KVA complete all as specified and as directed. |
| 81 | S&F in replacemet CT Suitable for DG set 100 KVA to 200 KVA complete all as specified and as directed. |
| 82 | S&F in replacement relay 24 v for AMF panel complete with all accessories complete all as specified and as directed. |
| 83 | S&F in replacemet HRC fuse 100 Amp with base assembly suitable of existing structure complete all as specified and as directed. |
| 84 | M&L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fan felt and radiator connection.Supply and fixing of new water pump assembly automatic grade suitable for DG set capacity of 25 KVA to 200 KVA of any make of DG set engine with all fitting accessories complete all as specified and as directed. |
| 85 | M & Lfor attending emergent complaint on call basis, checking ofDG Set (capactiy 25 KVA to 200 KVA ) & AMF Panel (any type and size) for detecting any kind of fault in DG Set & AMF Panel and attending the fault immediately at any time round the clock and carry out certain repair as per site requirement and checking of DG Set and AMF Panel and replacing of worn out parts of DG Set & AMF Panel by expert Engineer,complete all as specified and directed.Note : (a)Charges for detecting the fault in DG Set/AMF Panel/Electric System are included in the quoted items rate.(b)Amount of minor repairs, nut-botls-washers, cleaning cloth, grease etc are included in the quoted items rate.(c)Repalcement of worn out major parts of DG Set/AMF Panel shall be measured and paid separately under items of schedule \"A\". |
| 86 | M&L for AMF panel wiring with exist size copper wire complete all as specified and as directed. |
| 87 | M&L fordisconnecting, dismantling and overhauling of fuel injector pump of DG set capacity 25 KVA to 200 KVA and refixing properly to original position afterreplacement of Nozzle, F.I.P. Elements, Delivery valve, fuel pump gearand unserviceable parts etc. including overhauling, calibration and testing at admissible pressure properly complete all as specified and directed. |
| 88 | S&F in repair MCCB 63 Amps 3 Pole, 415V, Adjustable type,with breaking capacity 16 KA,Ics=100% of Icu, complete all as specified and as directed. |
| 89 | S&F in repair MCCB 100 Amps 3 Pole, 415V, Adjustable type,with breaking capacity 25 KA,Ics=100% of Icu, complete all as specified and as directed. |
| 90 | S&F in repair MCCB 63 Amps 4 Pole, 415V, Adjustable type,with breaking capacity 16 KA,Ics=100% of Icu, complete all as specified and as directed. |
| 91 | S&F in repair MCCB 100 Amps 4 Pole, 415V, Adjustable type,with breaking capacity 25 KA,Ics=100% of Icu, complete all as specified and as directed. |
| 92 | S&F in repair MCCB 125 Amps 4 Pole, 415V, Adjustable type,with breaking capacity 25 KA,Ics=100% of Icu, complete all as specified and as directed. |
| 93 | S&F in replacement onload changeover switch 100 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch complete all as specified and as directed. |
| 94 | All as per item No 87 above but onload changeover switch 63 Amps, complete all as specified and directed. |
| 95 | Supply and fixing in repair retro reflective boards in shape of rectangle of size1.0 m x1.4 m made out of 2 mm thick stainless steel both side bounded/pasted with high prismatic (iv) sheet mannufactured by avery dennison or 3 M with desired letters/logos designed as directed the board shall be supplied with and including stainless steel frame made out of 25 mm dia pipe in frame around duly welded with and including stainless steel sheet and stainless steel posts of 38 mm dia and full lengthof 2.20m one side and 2.8 m other side complete all as specified and directed. ( Note :(i) Rate for fixing of boards with PCC 1:2:4type B2 filling of size 45x45x60 cm to be incl in unit rate. (ii) The board should be written description as direction given by Engineer-in-Charge) |
| 96 | Supply, erecting & fixing in replacement steel tubular swaged pole complete with base plate, pole cap, nut bolt washer etctype 410 SP-31 (9.00 metres long) swaged poles conforming to IS 2713 (Part-I to III) 1980 all as specified including two coats of black bitumen paint through out internally and externally upto planting depth and applying two coats of aluminum paint over one coat of red oxide primer (externally) andNumbering of poles as directed including excavation /earth work, PCC 1:4:8 type D-2 using 40mm aggregate for pole foundations of size 600x600x1500mm height upto ground level and using PCC 1:2:4 B-1 for coping with size 450x450x300mm including necessary formwork, including taking down of old unserviceable pole, complete all as specified and as directed. |
| 97 | Materials and labour as in replacement for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including GI wire 4.0 mm as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 40mm GI light grade pipe for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 32 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. |
| 98 | Supply and fix in repair LED street light luminaires of capacity 60 watts with pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection and efficacy minimum 120 Lumen per watt, complete with driver, including three core copper flexible wire of size 0.75 Sqmm for connection from street light fitting to OH line or junction box, fixing accessories and complete all as specified and as directed. |
| 99 | Supply, fixing and testing, in replacement of Automatic Street light Timer Switch using combination ofNATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitable power contractor, MCB and support terminals should be enclosed in pole/ wall mountable SMC enclosure made out of Rust proof, Electric shock proof, termite proof and FR grade SMC junction Box conforming to IP 54 protection of capacity 12 KW 3 phase, current range 40 Amps, 4 wire (3 separate power contactor) including all accessories and fixing arrangement complete all as specified and as directed. |
| 100 | NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.)[(-) Rs. 91,963.00] |