Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #52522252

Tender For Maintenance Of Central Store Railway Siding At G.T.K. Road.Sub Head: Sitc Of Cctv System And Audio Conference System In Dda Office Complex At Central Store Railway Siding At G.T.K. Road Mukarba Chowk

Issued by Local Bodies · narela, Delhi
Tender Value
22.09 Lakhs
Estimated cost
Bid Submission
05 Dec 2025
0 days left
EMD
44192
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
narela → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Maintenance of Central Store Railway siding at G.T.K. Road.Sub Head: SITC of CCTV system and Audio conference system in DDA Office complex at Central Store Railway siding at G.T.K. Road Mukarba Chowk

BOQ

Name of work : M/o Central Store Railway siding at G.T.K. Road.Sub Head: SITC of CCTV system and Audio conference system in DDA Office complex at Central Store Railway siding at G.T.K. Road Mukarba Chowk
Sl. No. Item Description
1Supply, Installation and Testing of Audio Conference Central controller unit can be connect 50 number discussion units Number of Discussion Devices per Control Unit Max. 25 devices, Built-in Recorder with SD Card and USB Recording, with 30 watt Amplifier, Volume control: Mic1/Mic2/Aux input, Slide Switch for Limit On/Off, Speaker Output- 100V/8/4 Ohm, Frequency response: 200 Hz to 12 kHz, Microphone input with XLR connector, (Certifications EN 60065, EN 551032-2012) ,i/c connection etc. as required.
2Supply, Installation, Testing of chairman units feature a ‘chairman priority’ button with specifications: Priority button for chairman microphone, Microphone on/off button, Rotary volume control for adjusting headphone volume, Built‑in loudspeaker, Loudspeaker, automatically muted when microphone is on, Microphone ‘on’ indicator (red LED), Light ring indicator on microphone stem, lights up red when microphone is on, headphone socket, Frequency response: 400 Hz to 10 kHz,i/c connection etc. as required.
3Supply, Installation, Testing of Delegate units with specifications: Built-in volume control for headphones, Microphone with flexible stem and light ring, Microphone on/off button, Rotary volume control for adjusting headphone volume, Built‑in loudspeaker, Loudspeaker, automatically muted when microphone is on, Microphone ‘on’ indicator (red LED), Light ring indicator on microphone stem, lights up red when microphone is on, headphone socket, Frequency response: 400 Hz to 10 kHz,i/c connection etc. as required.
4Supply, Installation, Testing of 120 watt Mixer amplifier, Inbuilt Bluetooth for audio streaming, Supports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, LCD display, USB port, UBS/BT keyboard functions with IR remote sensor , Selectable 2 tone chime, Freq - 80 Hz to 18 KHz (+1/-3 dB), Distortion - <1%, Impedance 10Kohm, Sensitivity 1V, S/N - >70 dB, 100 V and 4-ohm loudspeaker outputs.(Certifications and approvals: Safety: acc. to IEC 62368-1, Vibration and shock: acc. to IEC 60068), i/c connection etc. complete as required.
5Supply, Installation, Testing of Wireless Mocrophone having Upto 8 selectable frequencies per band, Upto 4 compatible channel per band, Antenna diversity monitors signal strength, adjusting automatically for continuous reception. Audio Frequency Response: 50 Hz – 15 kHz, Maximum Output Level: -19 dBV (XLR), -5 dBV (1/4”) (ref. +/-33kHz deviation with 1 kHz tone) System Distortion: <1 % (ref. ±48 kHz deviation, 1 kHz tone).etc. complete as required.
6Supply, Installation, Testing of 15W wall mount indoor cabinet loudspeaker with robust ABS enclosure, having Rated Power - 15W (Taping 15/7.5/3.75/1.9 W), SPL : 98dB/92dB, Frequency range - 200-15000 Hz, Rated Voltage - 100V, Rated Impedance in ohms - 833. i/c connection etc. complete as required.
7Supply & fixing of Custom built Grommet in conference table suitable for connecting cable ofChairman & Delegate microphone i/c connection, testing etc. complete as required
8Supply and installation of custom built equipment trolly in suitable size & suitable for no’s of selves to accumulate. Amplifier and its accessories with door’s in front glass & lockable arrangements etc. as required.
9Supplying and laying of Conference Cable of 10 mtr., Cable terminated at both ends with a molded connector (male and female). i/c connections and interconnections, testing etc. as required.
10Supplying and Laying 2x1.5 sqmm Transparent PVC insulated speaker cable of 1.1 KV grade in the existing PVC pipe including connections and interconnections etc. as required.
11Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20mm
125/6MP((3200×1800)@20fpsorbetter)IPIR2.7mm~13.5mm Motorized lens, Vari Focal outdoor Bullet Camera,Angle of View: H: 104°–32°, V: 54°–18°, D: 125°–36° or better having following specifications and features as per Annexure-A. i/c connection & testing etc. complete as required.
13Supplying Installation Testing and Commissioning of 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 with camera licenses to record for all channels having specifications and features as per Annexure-A etci/c connection etc. complete as required.
14Supplying, Installation, Testing and Commissioning 6TB capacity Surveillance grade Hard Disk with up to 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
15Supplying and fixing of 128 cm (55\") UHD LED Monitor with resolution 3840x2160, HDMI, USB, Bluetooth testing, commissioning etc as required. including connections etc. complete as required.
16Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports
17Supply, installation, testing and commissionng of small form - pluggable (SFP) for network switches, with hot pluggable, RoHS compliant etc complete as requireda) 1G SFP single Mode/ Multi mode
18Supply and fixing following port Rack Mount loaded LIU with pigtail,a) 12Port LIU
19Supply and fixing following port Rack Mount loaded LIU with pigtail,a) 6 Port LIU
20Supplying, Installation & testing of following size of Rack with PDU, Fan, Hardware accessories etc. complete as required.15U Rack (Indoor)
21Supplying, Installation & testing of following size of Rack with PDU, Fan, Hardware accessories etc. complete as required.9U Rack (Indoor)
22Supplying, Installation & testing of following size of Rack with PDU, Fan, Hardware accessories etc. complete as required.6U Rack (Indoor)
23Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable
24supplying of following size HDPE pipe ISI marked along with aall accessories etc complete with fitting and cutting, jointing etc in the existing trenchcomplete as required.40mm dia
25Laying of one number PVC insulated and PVC shealthed XLPE power cable of 1.1KV grade of following size direct in ground including excavation and refilling the trench etc as required but excluding cushioning and protective covering etc as required.
26Supplying and fixing of following size medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
27Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. Single Mode 6 Core Optical fiber cable
28supplying and drawing of UTP 4 pair CAT 6 LAN armoured cable with accessories etc complete as reqquired
29supplying and laying following sizes of FRLS PVC insulated copper conductor armoured cable in the existing surface / recessed steel / PVC conduit as required2x1.5 sqmm
30supplying and installation of 1000VA online UPS with suitable size battery for 30 minutes battery backup including testing, commissioning, etc complete as required.
31Supplying, Installation & testing of 1 K.V.A. On-Line UPS for 30 minutes Battery Backup consisting with suitable size battery with accessories i/c testing etc. complete as required.
32Supplying, Installation & testing of 42 AH sealed maintenance free battery for the existing On-Line UPS for 30 minutes Battery Backup with accessories etc. complete as required.

AI Tender Summary

OUR REF NO 52522252
AUTHORITY Local Bodies
TENDER VALUE 22.09 Lakhs
LAST DATE 05-12-2025
Authority
Authority Name Delhi Development Authority
Work Description Maintenance of Central Store Railway siding at G.T.K. Road.Sub Head: SITC of CCTV system and Audio conference system in DDA Office complex at Central Store Railway siding at G.T.K. Road Mukarba Chowk
Basic Detail
Tender No 08/EE(E)/ELD-7/DDA/2025-26
Bidding Type Tender
Location
City narela
State Delhi
Key Dates
Publish Date 22 Nov 2025
Submission Date 05 Dec 2025
Open Date 06 Dec 2025
Finance
Tender Value 22.09 Lakhs
Tender Fee Ref. Documents
EMD 44192
Exemption Not Available
Document List
d72d6659-72de-478b-b3a8-8216f9b8de84.html
BOQ_932072.xls
NIT08.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 22, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 06, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

d72d6659-72de-478b-b3a8-8216f9b8de84.html

xls

BOQ_932072.xls

pdf

NIT08.pdf

pdf

Tendernotice_1.pdf