| 1 | Construction of Toilets and Brick work partition work |
| 2 | ExcavationEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.For all kinds of soil. |
| 3 | BackfillingFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and for all lift. |
| 4 | Disposalofbuildingrubbish/malba/similarunserviceable/surplusexcavatedearth, dismantled or waste materials by mechanical means, including loading, transporting, unloading toapprovedmunicipal dumpinggroundor asapprovedby Engineer-in-charge, beyond50 m initial lead, for all leads including all lifts involved asper the direction of Engineer-in-Charge.. |
| 5 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 6 | PCC (1:4:8)1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | All works upto Plinth LevelConcrete of M30 grade with minimum cement content of 350 kg /cum |
| 8 | All works above Plinth LevelConcrete of M30 grade with minimum cement content of 350 kg /cum |
| 9 | Shuttering in Foundation and plinth in rafts, footings, columns, pedestals, beams, walls,slabs,machine and equipment foundations, pile caps and pipe supportfoundations, etc. |
| 10 | Shuttering in Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Shuttering in Suspended floors, roofs, landings, balconies and access platform |
| 12 | Shuttering in Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | Shuttering in Shelves (Cast in situ) |
| 14 | TMTSteel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete all level.Thermo-Mechanically Treated (TMT) bars of grade Fe-500D or more. |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 17 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement :3 coarse sand) |
| 18 | 15mm thk plaster15 mm cement plaster on the rough side of single or half brick walls etc. complete in all respectsand as directed by EIC of mix 1:4 (1 cement: 4 fine sand) |
| 19 | 12mm thk plasterProviding at all heights 12 mm thick cement plaster on brick work, exposed surfaces of RCC lintels beams, etc complete in all respects and as directed with cement plaster mix 1:4 (1 cement: 4 fine sand) |
| 20 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm |
| 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 22 | Finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 sqm) |
| 23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 24 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 25 | Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the doorframe to be Jointed with galvanized brackets and stainless steel screws,joints mitred and Plastic welded. The hinge side vertical of the framesreinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the framecomplete as per manufacturer’s specification and direction of Engineerin-chargeExtruded section profile size 42x50 mm metre 280.70 |
| 26 | 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 27 | With float glass panes of 4.0 mm thickness |
| 28 | With float glass panes of 5.50 mm thickness |
| 29 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conformingtoIS:733andIS:1285,fixingwithdashfastenersofrequireddiaandsize, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/neoprenegasketetc.Aluminiumsectionsshallbesmooth,rustfree,straight, mitredandjointedmechanicallywhereverrequiredincludingcleatangle,Aluminiumsnap beadingforglazing/paneling,C.P.brass/stainlesssteelscrews,allcompleteasper architecturaldrawingsandthedirectionsofEngineer-in-charge. Powdercoatedaluminium (minimum thickness of powder coating 50 micron) |
| 30 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPD M rubber / neoprenegasketrequiredincludingnecessaryfittings.Powdercoatedaluminium(minimum thickness of powder coating 50 micron |
| 31 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 32 | Providing and fixing Vitreous China wash basin of size 630x450 mm. The following accessories Providing and fixing pillar cock of Jaquar or equivalent make all other fittings like CP waste coupling, CP brass bottle trap, CP brass stop cock, tap as required all connecting arrangement etc. including painting of fittings and brackets, cutting and making good the walls wherever required |
| 33 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 34 | Provoding and fixing nahani trap. The work shall include fixing the trap in PCC 1:2:4 and shall provide with Chromium plated brass hinged type heavy grating on the top. The deep seal traps shall have generally 50mm water seal: as required complete in all respect. |
| 35 | Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 122mm long, weighing not less than 99 gms |
| 36 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 37 | Providing and fixing C.P. brass angle valve points of approved quality conforming to IS:8931 |
| 38 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 39 | 15 mm nominal dia Pipes |
| 40 | 20 mm nominal dia Pipes |
| 41 | 25 mm nominal dia Pipes |
| 42 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. & Drawing. |
| 43 | Flexible pipe- 32 mm dia |
| 44 | ProvidingandfixingPTMTliquidsoapcontainer109mmwide,125mmhighand112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 45 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 46 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 47 | 25 mm dia nominal bore |
| 48 | Installation (All complete) of Hume Pipe Septic Tank along with Soak Pit (Capacity of Septic Tank- 1.2cum). |
| 49 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 750mmx500 mm deep and 18 mm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.White Agaria Marble Stone. |
| 50 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 51 | Wiring for twin controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed pvc conduit, with 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 52 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit,2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 53 | Supplyingoffixing of medium classPVCconduit 25mm ISI marked along with accessoriesin surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 54 | Supply and Fixing folowing size/modules, GI box along with modular base and cover plate for modular switches in recess etc.6 Module |
| 55 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 56 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin, 5/6 A socket outlet |
| 57 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 58 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin, 15/16 A Socket |
| 59 | Supplyingoffixing ofdouble pole, 240V, residual current circuit breaker having a senstivity current of 30mA in the exisiting MCB DB, complete with connections, testing and commissioning etc as required 25A |
| 60 | Steel Structure for GateStructural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 61 | Painting of Steel GatePainting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |