| 1 | Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed. |
| 2 | Rolling and consolidation formation surfaces in cutting with 8 to 12 tonne power roller complete all as specified and directed. |
| 3 | M&L 200mm thicksoling(or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and cambercomplete all as specified and directed. |
| 4 | M&L 150mm thick (compacted thickness) WBM in two layer 75mm each, with coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size) of granite, trap or basalt spread, rolled and consolidated to gradient and camber required complete all as specified and directed. |
| 5 | M&L sand filling under floor or in foundations including watering and consolidation under ILCB complete all as specified and directed. |
| 6 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 Grade with grey cement and no pigmentcomplete all as specified and directed. |
| 7 | M&L for providing, plain cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) cast in situ as in lintels upto 1.5m clear span, cills, and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and directed. |
| 8 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 9 | M&L for providing reinforced cement concrete 1:2:4, type B-1, (using 20mm graded stone aggregate)as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed. |
| 10 | M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 11 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |