Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-12-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 2 | M&L for flyash brick work with old size bricks straight or curved on plan exc 6M mean radius built in CM 1:6complete all as specified and directed. |
| 3 | M&L for flyash brick work with old size bricks straight or curved on plan exc 6M mean radius built in CM 1:4complete all as specified and directed. |
| 4 | M & L for Brickwork with fly ash bricks ,straight or curved in any radius in half brick thick walls built in cement mortar 1: 4 complete all as specified and directed. |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and paving n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 6 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection etc, finishingsurface even and smooth without using extra cementcomplete as specified and directed. (Note : The concrete shall be laid at a stretch n.exc 3.0 m in length and in every turning/ corners.) |
| 7 | M & L for providing PCC 1:3:6, type C1 (using 20mm graded stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified. |
| 8 | M & L for providing PCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in surface channel complete all as specified. |
| 9 | Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area, complete all as specified and directed. |
| 10 | M & L for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 11 | M & L for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished the surfaces fair and even complete all as specified and directed. |
| 12 | M & L for preparation of new surfaces of wall and applying plaster of paris putty of 1 mm thickness over a coat of primer and prepare the surface even and smooth and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colourcomplete all as specified and as directed. |
| 13 | M&L for rendering 15mm thick in CM 1:4using WPC on brick work/concrete wall surface and finished fair and even cement complete all as specifed and as directed. Note : WPC WILL BE MEASURED AND PAID SEPERATELY |
| 14 | M & L for 15 mm thick renderingon fair faces of brick work or concrete surfaces of wallsetc 10 mm thick im CM 1:6 and 5 mm thick inCM 1:4mixed with water proofing compound as per manufacturers instruction & finished the surfaces even and smooth without using extra cement, complete all as specified and directed. Note : WPC WILL BE MEASURED AND PAID SEPERATELY |
| 15 | Supply only Liquid water proofing compoud |
| 16 | M & L for Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 17 | M & L for Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 18 | Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls all as specified and as directed. Make: APEX ofAsian or equivalent of Shalimar / Nerolac/ Berger. |
| 19 | M & L for complete removal of existing treatment and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls all as specified and as directed. Make: APEX ofAsian or equivalent of Shalimar / Nerolac/ Berger. |
| 20 | M & L for complete removal of existing treatment on old wall surfaces and applying plaster of paris putty of 1 mm thickness over a coat of primer and prepare the surface even and smooth and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colourcomplete all as specified and as directed. |
| 21 | M&L forPreparation of Existing surfaces of walls/chajjas/facia etc in patches to remove all dirt, mildew and other contaminants. Treat areas affected by Algae, moss or fungal growth with biocide wash solution and pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely. All surface cracks up to 5 mm width should be filled up with Dr. Fixit Crack-X or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP.Cracks more than 5 mm and all separation gaps should be filled up with Dr. Fixit Pidicrete URP modified mortar or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP. Primingusing Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2 parts Prime seal diluted with 1 part water) @ 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs. Apply one coat of Dr. Fixit Raincoat Waterproof Coating or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP without dilution by brush or roller for walls at the thickness of 120 – 130 microns all as specified and directed .Note: All above treatment will be measured as one unit of square metre and paid accordingly. |
| 22 | M&L for rendering 5 mm thick using CM (1:3) in patches on ceiling surfaces finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 23 | M&L for rendering 10 mm thick using CM (1:3) in patches on ceiling surfaces finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 24 | Excavating in post holes (or similar holes) in soft/loose soil, each post holen exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and removing surplus soil to a distance not exc 50m and making good surfaces complete all as specified and as directed. |
| 25 | M&L for plain cement concrete Type C-2 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 26 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 27 | S&F pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 28 | M&L 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in 15 mm thick backing coat cement mortar (1 : 4) including pointing ,moulding the edges in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 29 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 30 | M/L 10mm dia and over TMT bars as in reinforecment cut to length bent to shape required including cranking hooking ends and binding with mild steel wire( annealed) not less than 0.9 mm dia (or) securing with clips all as specified and as directed |
| 31 | Use and waste of formwork to suspended slabs such as roof slabs, floor slabs, floor slabs landings and similar work; not exceeding 200mm thick; make rough finished surfaces complete all as specifed and as directed. |
| 32 | M&L for reinforced cement concrete Type A0 1:1.5:3using 12.5mm graded aggregates in slab supported on walls, beams and colums in floors,roofs ,landing ,balconies,canopies,deck slabs and in shelvesand the like complete all as specified and directed. |
| 33 | Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area nexc.1.5 sqm each including separating guard bars/grills/wire mesh etc., all as specified and as directed by the Engineer-in-Charge. |
| 34 | Dismantling plain or corrugated steel sheeting any gauge, any thickness, including nainital or similar pattern roof covering complete all as specified and as directed. |
| 35 | S&F aluminium powder coated sliding window (for width 1.00 above and openable for below 1.50 M width)using aluminium section weighing not less than 0.495 Kg per RM for frame and 0.48 Kg per RM for sliding shutters includingaluminium anodised snap beads, screws andfixed along with same sectionin three rolling sliding shutters two for fully glazed with 5mm thick tinted glass fixed with glazing clips, and one for wire mesh shutters) etc(The rate is inclusive of all fixings of builders hard ware such as wiremesh hinges, bow handles, locking arrangements etccomplete all as specified and as directed. |
| 36 | S&F Anodised aluminium door shutterspowder coating of any colour (Thickness or powder coating not less than 50 micron), aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised alumnium snap beading, screws etc. complete all as specified |
| 37 | S&F figured glass 4mm thick, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane (any thickness, size, quality or description ) to wooden/aluminium frames or stone, concrete or brick surrounds, glazed with putty or fixed with beadsall as specified |
| 38 | S&F aluminium alloy wire mesh 0.45mm nominal dia of wire and averagewidth of aperture 1.40 mm and fixed with aluminium wire staples fixed to wood/steel frames complete all as specified and directed. |
| 39 | Cutting existing steel tubing of 20mm diafor alterations oradditions (Each cut measured) complete all as specified and directed. |
| 40 | Cutting existing steel tubing of 25mm diafor alterations oradditions (Each cut measured) complete all as specified and directed. |
| 41 | M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surfacebased materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces complete all as specified and directed. |
| 42 | S&F Designing, fabricating, supplying and installing in position of approved shade, FR Class B Grade Fire Rated Aluminum composite panel cladding either straight or curved in plan, comprising Aluminum Composite Panel which should consist of 3 mm thickness of mineral core (70% inorganic and 30% organic compound) sandwiched between two Aluminum coil of alloy AL 3105/AL 5005 – H16/H24 of 0.50 mm thickness making an overall thickness of 4mm. The weight of ACP should be above 7.5 kg/m2. The top surface shall be finished with PVDF/FEVE based coating (thickness 26 microns + or - 2 microns) providing 15-year warranty and service coating on the reverse side shall be with PE (Thickness 5-7 microns) base and coating shall be confirm to AAMA 2605 standard done on a color coating line located in India. The Aluminum composite Panel should confirm as per standard EN - 13501 -1 Class B s1-d0 certification along with NFPA-285 certification for fire propagation, and also with certification for ASTM E-84 reaction to fire from an International third-party testing lab. The manufacturer must have a valid FPC Certificate (Factory Production Control) on reaction to fire as per class B complete all as specified and directed. Make : Viva Composite Panel Pvt Ltd or its techno commercial equivalent in other makes. |
| 43 | M & L for Chipping, Chiselling surface mechanically with chipping machine :-(1) Providing zinc rich primer for treating exposed reinforcement(2) Providing 100x100x3mm weld mesh and fixing the same with shear connectors of 8 mm dia with epoxy resin.(3)guniting the area with CM 1:3 of over all thickness 50mm in with two layers in small areas/patchesnexc 1.5Sqm complete all as specified and as directed. |
| 44 | M & L for carrying out crack repair work in walls as follows:- Cleaning the surface around crack and jointfree from loose particles and dust, cutting \"V\" shaped groove of size in range of 6 to 25mm of width and depth along the crack line by machine or manually, then clean the groove by wire brush to remove loose particles and then washed by water jet, and fixing nozzle and repairing cracks using Fosroc Rendroc CS chemical or its techno commercial equivalent chemical manufactured by CICO/STP/MC BAUCHMIE/DR FIXIT/BASF with a proportion of 1 part of water to 2.5-3.0 part of above chemical by volume or w/p ratio 0.36 by weight complete all as specified and as directed. |
| 45 | S&F Solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge metredcut at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the 19mm x 19mm square tube fixed to wall in repairs by drilling 100mm long MS screws using PVC fastener all as per specification and directed. |
| 46 | S&F Factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick with 2,4,6 raised panel design with 2mm thick moulded Prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying and fixing in frame at site as per specification and drawingand as directed. |
| 47 | S&F powder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified(Thickness of powder coating not less than 50 micron) complete all as specified and as directed. |
| 48 | M&L 2nd class hard wood Plain fillets.square,rectangular or triangular in section, exc 13sqcm nexc 25sqcm clean sawn, secured with nails or brads complete all as specified and directed. |
| 49 | S & F12 mm thick Prelaminated Particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber / aluminium frame work complete all as specified and as directed. |
| 50 | S & F in repairs 18/19 mm thick Prelaminated Particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work as in repaircomplete all as specified and as directed. |
| 51 | S&F Sheet glass 5.5mm thick, plain ordinary quality & glazing with oil putty in square exc 0.5 sq.m in each panecomplete all as specified and as directed. |
| 52 | M & L for 6mm thick external teak wood lipping over 18/19mm thick particle board/plywood fixed with nails complete all as specified and as directed. |
| 53 | S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified & directed. |
| 54 | S&F Aluminium handlescasttypeanodised 150 mm size complete all as specified and directed. |
| 55 | S & F in repairs Aluminium (Die cast ) body door closer hydraulically regulated, designation No.2 universal type, suitable for door shutters up to 701mm to 850 mmin width and of weightbetween 36 to 60 kg complete all as specified and directed. |
| 56 | S & F in repairs stainless steel Cabinet Hinges/self closing hinges (Bombay Hinges) complete all as specified and as directed |
| 57 | S & FMagnet closures to cabinet cupboards complete all as specified and as directed. |
| 58 | S&F Aluminium anodisedbarrel tower bolts of extrudedsection 200mm long complete all as specified and directed. |
| 59 | S&F in repair Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrs including S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe complete all as specified and directed. |
| 60 | M & L in repair Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25 mm dia bore pipes complete all as specified and as directed. |
| 61 | S&F in repairs 15mm dia bib taps fancy type, chromium platedwith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specifiedand as directed. |
| 62 | S&Fin repairs Sink made out of stainless steel 1mm thick with drainage board for kitchen and laboratory with plugs, washers and wastes, including beading in cement mortar to dwarf of including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size for 410mmx330mmx160mm including 40mm size CP waste coupling and PVC waste pipe complete all as specifiedand as directed. Make : NIRALI/JAYNA/DIAMOND/ PARRYWARE |
| 63 | S & F in repairs 15 mm dia bore pillar tap long neck with aerator fancy type cast copper alloy with crutch handle screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe or for brass ferrule etc complete of make that shall match with existing fitting i.e, jaquar complete all as specifiedand as directed. |
| 64 | S&F in repairs fortwo waybib tap 15 mm bore chromium plated with crutch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union of make jaquar or its techno commercial equivalent in other makes complete all as specified and directed. |
| 65 | S&F in repairs vitreous china wash basin of oval type including counter top granite platform , waste coupling, waste pipe and brackets etccomplete all as specifiedand as directed. |
| 66 | S&F in repairs angular stop cock 15 mm dia brass chromium plated fancy type with long shank, screwed down high pressure with crutch or butter fly handle screwed down both ends for iron pipe or for union of make that shall match with existing fitting i.e, jaquar complete all as specifiedand as directed. |
| 67 | S&F in repairs vitreous china wash down water closet pan, dual flush system cascade dual flush selected colour with built in cistern floor mounted type with Por S trap and matching seat cover including all fittings complete all as specifiedand as directed. |
| 68 | S&F in repairs Vitreous China Urinal, half stall type, white (excluding flushing cistern, flush pipe & waste pipe) but including connections to flushing pipe and outgoing pipes , urinal spreader complete all as specifiedand as directed. |
| 69 | S&F in repairs health faucet (hand shower with 1 M flexible tube with wall hook, chromium platedof make that shall match with existing fitting i.e, jaquar complete all as specifiedand as directed. |
| 70 | S&F in repairs toilet paper holder with flat recessed type matt chromium plated of make that shall match with existing fitting i.e, jaquar complete all as specifiedand as directed. |
| 71 | S&F in repairs soap dish, matt finished chromium plated (MCH/Colour CP) of make that shall match with existing fitting i.e, jaquar complete all as specifiedand as directed. |
| 72 | S&Fin repairs PVC waste pipe for wash hand basin/ Urinal (size 31/32mm x 800mm length)of make that shall match with existing fitting i.e, Prayag complete all as specifiedand as directed. |
| 73 | S&Fin repairs PVC waste pipe for Sink waste pipe (size 38/40mm x 1150mm length)of make that shall match with existing fitting i.e, Prayag complete all as specifiedand as directed. |
| 74 | S & F Stainless steel plate rack of size 24X36X10 inch fixed on wall with stainless screw with wooden plugs near the kitchen sink including all accessories and making good the disturbed wall tiles/concrete surface all as specified and directed. |
| 75 | S&F in repairCP cockroach trap (127mmx127mm) with waste hole of make that shall match with existing fitting i.e, Prayag complete all as specifiedand as directed. |
| 76 | S&F in repairs 15mm PVC connection with two brass nuts 450mm long of superior quality complete all as specified and as directed. |
| 77 | M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cementcomplete all as specified and as directed. |
| 78 | Supply and Fix6mm thick looking mirror plain glass of size exc 1.50 Sqm on selected quality mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers and edges are finished with grinding / polishing complete all as specified and as directed. |
| 79 | S&F in repairs towel rail 600mm long between flanges, chromium plated of make that shall match with existing fitting i.e, jaquar complete all as specifiedand as directed. |
| 80 | Dismantlingfloor, hearth or walltiling incl cement mortar bedding (but not backing), removingunserviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 81 | M &LNon -skidcoloured ceramic joint freetiles7 mm to 8 mm (Square/rectangular) concept tiles design as approved area of eachtilesexceeding 0.11 sqm but not exceeding0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including15 mm thick screed bed in CM 1:4. complete all as specified and as directed. |
| 82 | M&L for Vitrified Ceramic light coloured double charged tilesof 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour and pattern of the tile as approved over and including 15 mm thick screed bed in Cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 83 | M&L for glazed coloured ceramic Concept designer tiles of7mm thick and area exceeding 0.11 sqm and not exceeding 0.18 Sqm as approved by GE,fixed in vertical surfaces in Patches such as in dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over and including a backing coat in Cement Mortar 1:4, 10mm thick complete all as specified and as directed. |
| 84 | Supply & Laying of CPVC PipesSDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete all pipe fittings and including taking up or down in the existing pipe line completelyall as specified for following pipes :-(a)20mm outer dia bore |
| 85 | (b)25mm outer dia bore |
| 86 | (c)32mm outer dia bore |
| 87 | M & L for Cutting holes into or through brick walls built in cement mortar and making good inPCC (1:2:4) type B-1 as required Superficial area not exceeding 150Sqcm complete all as specified and as directed. |
| 88 | M & L for Cutting holes into or through brick walls built in cement mortar and making good inPCC (1:2:4) type B-1 as required Superficial areaexc 150 Sq CMbut not exceeding 400Sqcm complete all as specified and as directed. |
| 89 | M & L for Cutting holes into or through brick walls built in cement mortar and making good inPCC (1:2:4) type B-1 as required Superficial areaexc 400 Sq CMbut not exceeding 0.1 Sqm complete all as specified and as directed. |
| 90 | M & L for Cutting chases in brick walls , pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduitwiring, etc. and making good, cutting exceeding 20cm girthcomplete all as specified and as directed. |
| 91 | M & L for Cutting chases in brick walls , pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduitwiring, etc. and making good, cutting not exceeding 10cm girthcomplete all as specified and as directed. |
| 92 | M & L for Cutting chases in brick walls , pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduitwiring, etc. and making good, cutting not exceeding 20cm girthcomplete all as specified and as directed. |
| 93 | S & F PVC (SWR) pipes 110mmsingle socketed, in any length with rubber ringjoints fixed to walls /floor as in spouts etc complete including dismantling existing pipescomplete all as specified and as directed. |
| 94 | S & F PVC (SWR) pipes 110mmsingle socketed, in any length with rubber ringjoints laid in trenches or in floor complete all as specified anddirected. |
| 95 | S & F PVC (SWR) pipes 75mmsingle socketed, in any length with rubber ringjoints fixed to walls /floor as in spouts etc complete including dismantling existing pipescomplete all as specified and as directed. |
| 96 | S & F in repairs PVC (SWR) bends 110 mm bore any radius with oval access door complete all as specified anddirected. |
| 97 | S & F PVC (SWR) bends 110 mm bore any radius with oval access door complete all as specified anddirected. |
| 98 | S & F in repairs PVC (SWR) bends 75 mm bore any radius with oval access door complete all as specified anddirected. |
| 99 | S & F PVC (SWR) junction single (single T ) equal or un equal withaccess door 75 mm fixed in repairs complete all as specified anddirected. |
| 100 | S & F PVC (SWR) junction single (single T ) equal or un equal withaccess door 110 mm fixed in repairs complete all as specified anddirected. |
| 101 | S & F in repair (SWR)vent cowl suitable for 110 mm bore pipecomplete all as specified and as directed. |
| 102 | Excavation in trenches n. exc 1.5m wide and n. exc 1.5m deep for foundation, or for shafts, wells, cesspits, manholes, pier holes etc, n. exc 10 sqm on plan getting hrad/ dense soil complete all as specified and as directed. |
| 103 | Returning filling in foundation including levelling watering and well ramming in layers not exc 25cm using excavated soil all as directed. Note:- For sewage line removal of surplus earth shall not be measured and shall be mounted over refilling. |
| 104 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.50m above the starting point and all as directed. |
| 105 | M & L for 150mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified & as directed. |
| 106 | M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in for 150 mm diapipe line andset in cement mortar complete all as specified and as directed. |
| 107 | M&L for Precast cover slab 1:2:4, type B1 (using 20mm graded aggregate) inlandings, cover slabs (for manholes etc.,) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4, for manholes etccomplete all as specified and as directed. Note: Reinforcement will be measured and paid seperately. |
| 108 | S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. Fe-410- W(Gde- E-250) quality- B (cut to ordinary lengths i.e. Within 20mm of the length indicated) all as specified and directed. |
| 109 | M&L for Plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk)forming holes, without any attachment confirming to Fe 410 - W (Grade E-250 Quality -A ) complete all as specified and as directed. |
| 110 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B complete all as specified and as directed. |
| 111 | S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165complete all as specified and as directed. |
| 112 | Complete removal of existing roof treatment any type and demolition of cement concrete padding at roof slab n exc 15cm thickness complete all as specified and directed. |
| 113 | M & L for plain cement concrete 40mm thick average thickness as roof padding type B0, 1:2:4 (12.5mm graded aggregate) finished fair and even over concrete surface on roof top, and finished even and smooth with 10mm thick cement plaster in CM 1:4 mixed with WPC @ 200 ml per bag, when the concrete is green all as per manufacturer instructions and as specified and as directed. ( Note: Water proofing compound will be paid under measured separately) |
| 114 | Cleaning and preparation of newly plastered roof surfaces and applying the water proofing treatment as under.(a)Applying 1st course of bituminous (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed.(b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm.(c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane,(e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed. |
| 115 | Taking down of existing cement or lime plaster along with the existing water proofing treatment on walls andapplying 10 mm thick cement plaster 1:3 mixed with liquid Water Proofing Compound @ 200 ml per bag, cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under. (a)Applying 1st course of bituminous (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed.(b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm.(c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane,(e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed. |
| 116 | M&L for point wiring of size 1.5 sqmmwith PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through new non metallic rigid PVC conduit including accessories,concealed in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dollyincluding taking down carefully copper/aluminium point wiringlight, fan, socket or powercomplete with fittings such as switches, ceiling roses, regulators sockets etcand making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and as directed for :- (a) one light point controlled by one switch |
| 117 | (b) one exhaust fan point controlled by one switch |
| 118 | (c )one 3 pin socket outlet 5 amps on the same board controlled by one switch. |
| 119 | (d) one 3 pin socket outlet 5 amps on independent board controlled by one switch. |
| 120 | As per above item No. 116 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed. |
| 121 | S& F for modular cover plate with frame 3 module complete all as specified and directed. |
| 122 | S& F for modular cover plate with frame 4 module complete all as specified and directed. |
| 123 | S& F for modular cover plate with frame 6 module complete all as specified and directed. |
| 124 | S&F modular switches suitable fortype AC 240V, 6 amps 1 modulecomplete all as specified and directed. |
| 125 | S&F modular socketssuitable fortype AC 240V, 6 amps 2 modulecomplete all as specified and directed. |
| 126 | S&F modular switches suitable fortype AC 240V, 16 amps 1 modulecomplete all as specified and directed. |
| 127 | S&F modular power socketssuitable fortype AC 240V, 16 amps 2 modulecomplete all as specified and directed. |
| 128 | S&F modular bell switchsuitable fortype AC 240V, 16 amps complete all as specified and directed by Engr-in-Charge |
| 129 | S&F call bell of ding dong type A/C 230 voltscomplete all as specified and directed by Engr-in Charge |
| 130 | S&F ceiling rose , polycarbonate, isolated bodywith 2 to 3 terminalscomplete all as specified and directed. |
| 131 | Supply and fix exhaust fan, steel body AC Single phase230V of size 300mm sweep with blades and frames louvers complete and old fan deposit to E/M store complete all as specified and directed. |
| 132 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, 5 starand old fan deposit to E/M store complete all as specified and directed. |
| 133 | S&F lamp holder insulated body with back plate for batten fittings/angle holdercomplete all as specified and as directed |
| 134 | S&F ofLED bulb 9 w highsuitable for lamp holder including taking down carefully unserviceable fittings and making good disturbed surfaces of walls, floors to match with the existing surfacecomplete all as specifiedand as directed.Make :Havells Cat No. LED PLUS 9W B22 CDL 2STAR LAMP or techno commercial equivalent in Philips /Bajaj |
| 135 | S & F 20 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminum housing with wide range of wattages to suite variety of application areas, complete including taking downall as specified and directed by the Engr-in-Charge. Make : Havells Cat No.LUMILINEPLUSNEOBS20WLED865SPCSSIND or techno commercial equivalent Philips/Bajaj. |
| 136 | S & F 20 watts LED WARM LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminium housing with wide range of wattage to suit variety of application areas, including taking downcomplete after taking proper disconnecting of electric supply properly andmaking good surfacecomplete all as specified and directed. Make Havells Cat Part No. LUMILINEPLUSNEOBS20WLED830SPCSSIND or equivalent in Philips/Bajaj. |
| 137 | S & F 15 watts round ceiling WARM LIGHT with a functional range of aesthetically designed surface mounted downlights with aluminium housing and heat sink for better thermal performances, including taking downcomplete after taking proper disconnecting of electric supply properly andmaking good surfacecomplete all as specified and as directed. Make Havells Cat Part No.INTEGRANXTRDDLRSURD15WLED830S or equivalent to Philips/ Bajaj. |
| 138 | S&F sub main wiringcomplete with two runs of 4 sqmmPVC insulatedunsheathed single core multistrand copper conductorcable of 1100 volts grade drawnthrough new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceilingwith one run of 4 sqmm PVC insulatedunsheathed copperconductorcable as earth continuity conductor including taking down all as specified and directed by Engr-in-Charge.Note:- Two runs of PVCinsulatedcable 4 sqmm+ one run 4 sqmmof earth wire and one run of conduit including accessories shall be measured as one length. |
| 139 | S&F MCB distribution board made ofCRCA sheet, powder coatedpaint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 230 volts 4 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection including taking downcomplete after taking proper disconnecting of electric supply properly andmaking good surfacecomplete all as specified and directed. |
| 140 | S&F MCB of rating 240 Volts, SPN 32 Ampsincluding taking downcomplete after taking proper disconnecting of electric supply properly andmaking good surfacecomplete all as specified and directed. |
| 141 | S&F MCB of Single pole of rating 6 to 32 Amps 240 Volts including taking downcomplete after taking proper disconnecting of electric supply properly andmaking good surfacecomplete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy