| 1 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.SI.No.641/2081,Elec. |
| 2 | S/F of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 watt. Confirming to IP 66 protection complete in all respect. (SI.No. 1423-AAA/2018)Elec. SOR |
| 3 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core ,SI.No.501(i)/Elec.2018 |
| 4 | S/F of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.(SI.No.504e/2018) SOR |
| 5 | S/F of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with Cts etc. in case of TPN complete in all respect. 40 amp TPN (SI.No.807c(ii)/2018) SOR |
| 6 | S/L of 1.5 mm copper wire. (SI.No.1.17.12/2022)DSR Elec. |
| 7 | S/L of follwing size DWC HDPE pipe (OD-63 mm & ID 51 mm nominal)DSR SI.No.14.16.1/2022/Elec.E-file No. MZDA.ENGG O BILL/47/2025-ENGG-MZDA |
| 8 | Supply and burying earth eletrode for lighting conductor of 600 mm x 600mm x 3mm copper plate vertically with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per direction of the Engineer-Incharge.(SI.No.725(D)/2018)Elec. SOR |
| 9 | Decorative pole Virgo made of Mild Steel with a total height of 7mtr above ground level with Single arm bracket and predefined pattern in between the top portion of the pole bracket. Pole bottom base section shall be 350x350x1500mm, 4mm thickness column with two sided predesigned laser cut to illuminate the surroundings in 20W with noticeable mode, next section embedded with double pole of diameter 60mm embedded together to form a unique design of golden casting embellishment and laser cut pattern between two poles illuminated with Flexible Linear Washer and unique designer single arm bracket to hold the street light. The width of the arm is 2500mm on the top. The base plate of pole shall be of size 350x350x12mm. Provision for inside termination box with 4way connector & 1nos 6 AMPS MCB for local isolation. The pole and light fixture is primarily coated with primer, secondary epoxy resin and top coated with UV stabilized powder coat and cured. The decorative pole is suitable for outdoor lighting application. Pole light is complete in all aspects with all accessories without foundation bolts. Eagle light fixture shall be made of die cast aluminium. Light output of source is more than 110lm/ watt, CRI>70, SPD 10k, Pf>.9, THD<=10%, operating voltage 140-270V. Fitting is IP66, wired with Branded LED and constant current driver. Proper thermal management for longer life of fixture. Led burning of 50,000 hours. The light is primarily coated with primer, secondary epoxy resin and top coated with UV stabilized PU paint or powder coat and cured. The Flexible Linear Washer is composed with Led in series jacketed by an inner plastic extrusion with IP 67 encapsulation. It is used to illuminate the overall laser cut pattern on pole of approximate size of 1.5-2mtr with 6W per mtr, color temperature 3000K, 12VDC driver. Flexible Linear Washer to be mounted with the help of clips. |
| 10 | Transfarmer and line extesion etc. |
| 11 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6 sq. mm 3 core ,SI.No.501(e)/Elec.2018 |
| 12 | Excavation in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50 M lead upto 30 M and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in-charge upto a distance of 30 M from the foundation trenches. (S.I. No. 251a) /2022 |
| 13 | Concrete with 4cm. gauge brick ballast, coarse sand of 2.20 F.M and cement in proportion of 8:4:1 in foundation and under floors, including supply of all materials, labour, T&P etc. required for proper completion of the work.(SI.No.281/2022) |
| 14 | RCC work with cement, approved Coarse sand and 40mm stone grit in proportion of 1:1.5:3 in raft and foundation excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire. (S.I. No. 287a/2022) |
| 15 | M.S (Tor steel or plain) work in plain work such as RCC or RB work including bending for proper shape and including supply of steel and its wastage, bend, hooks and authorized over lapping shall be measured and including cost of binding wire (S.I. No. 504/2022) A.R. Please Enable Macros to View BoQ information |