| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | Dismantling framed trusses span n.exc 10 mtr complete all as specified and directed. |
| 3 | Dismantling of wall and ceiling Boards (Fiber, pulp, Insulation etc) or insulation Board/ slab/ blankets any thickness including cover fillets complete all as specified and directed. |
| 4 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 5 | Taking down chowkats or frames with shutters (with out taking off shutters from the frames) area not exc 1.5 Sqm each complete all as specified and directed. |
| 6 | Taking down chowkats or frames with shutters (with out taking off shutters from the frames) area exc 1.5 sqm but not exc 4.0 Sqm each complete all as specified and directed. |
| 7 | Demolition of cement concrete of any position and description complete all as specified and directed. |
| 8 | Dismantling wrought iron or mild steel work of any description complete all as specified and as directed. |
| 9 | M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 10 | M&L for brickwork with burnt fly ash old size bricks, straight or curved on plan exc 6m meanradius, built in cement mortar (1:6) complete all as specified and directed. |
| 11 | M&L for RCC (1:1.5:3) nominal mix type A1 (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 12 | Use and waste of form work to sides ofconcrete foundation, footings, bases ofcolumns, raft and raft beams sides and soffits (if any) of foundation and plinth beams for flat rough finished concrete surface complete all as specified and directed. |
| 13 | M&L for RCC (1:1.5:3) nominal mix type A1 (using 20 mm graded stone aggregate) as inbeam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 14 | Use and waste of form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers,lintels, cantilevers, shelves,for flatrough finished concrete surfaces complete all as specified and directed. |
| 15 | M&L for RCC (1:1.5:3) nominal mix type A1 (using 20 mm graded stone aggregate) as in chajjas and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 16 | Use and waste of form work to chullah hood, chajjas, troughs and similar items including edges etc for rough finished flat concrete surface complete all as specified and directed. |
| 17 | M&L for mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | M&L for mild steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | M&L for mild steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binderscut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 20 | M&L for external rendering 20 mm thick in two layers, first layer shall be of 10 mm thick in CM (1:6) and second layer of finishing coat shall be 10 mm thick in CM (1:4) mixed with WPC@ 200 ml per 50 Kg of cement bag on brick work or concrete surfaces of wall and finished even and fair complete all as specified and directed.Note-WPC shall be measured and paid separately. |
| 21 | Supply only liquid water proofing compound all as specified and directed. |
| 22 | M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement complete all as specified and directed. |
| 23 | S&F rolled mild steel in structural steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde -E-250 quality- A) duly painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication all as specified and directed. |
| 24 | M&L for steel work in tubular trusses, purlins, post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 gradeSt.-240 painted one shop coat of red oxide primer. |
| 25 | S&F rolled mild steel MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentconfirming to Fe-410-W (Gde E-250 quality B) complete all as specified and as directed by Engineer-in-charge. |
| 26 | S&F Mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 22.5cm & n exc 30cm long dia of shank 16 to 20 mm. |
| 27 | S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates, hook and pintle hinges, large hasps and staples, hold fasts, wall ties, hooks for hanging fans, cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 28 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/ cladding/ eaves board fixed with self tapping screw complete all as specified and directed. |
| 29 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/eaves board fixed with self tapping screw complete all as specified and directed. |
| 30 | S&F anodised aluminium snap grid frame work of size 605x605mm for false ceilingall as specified and as directed |
| 31 | M&L for 4mm thick non asbestos, fibre reinforced standard cement board as in ceiling, designer board complete all as specified and as directed |
| 32 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 33 | M&L for moorum/ red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 34 | M&L for 100 mm thick Cement concrete (1:4:8)type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 35 | M&L for 25mm thick PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in floors, finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 36 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 37 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in vertical surface /skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including rendering 10 mm thick in cement mortar 1:4 complete all as specified and directed. |
| 38 | S&F pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including one shop coat of priming complete all as specified and directed. |
| 39 | M&L for providing plain cement concrete (1:3:6) type C-1, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 40 | S&F 30mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified and directed. |
| 41 | Supply and fixing of factory made partly glazed three panels i.e. upper panel will be wire mesh and further divided into two panels fitted externally in the clear space & lower panel will be plain colour PVC sheet 5mm thick PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Paneling of plain colour PVC sheet to be fitted in the M.S.frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as per specified and as directed. |
| 42 | S&F 140 mm size floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 43 | S&F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 44 | S&F aluminium anodised barrel tower bolts of extruded section 200 mm long all as specified and directed. |
| 45 | S&F aluminium handles 150mm size cast type anodised complete all as specified and directed. |
| 46 | S&F aluminium anodised, Sliding door bolt of 300mm long, fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 47 | S&F Powder coatedaluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazingcleats, rubber packing , screws, handle, locking arrangement and 4 mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall complete all as specified and as directed. |
| 48 | S&F in repair stainless steel curtain rods 20-25 mm dia, anodised aluminium alloy with fixing brackets, stops, and complete fitments all as specified and directed. |
| 49 | S&F in repair MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 50 | S&F Ball catches with 8mm dia steelball, and brass body and striking plate including letting in complete all as specified and as directed. |
| 51 | S&F stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and directed. |
| 52 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, frame work of water tanks and similar work conforming toFe -290 Gde E-165 complete all as specified and directed. |
| 53 | M&L for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as Specified. |
| 54 | M&L for preparation of newly plasteredsurfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coats ofcement based wall putty 1 mm thick (Avg thickness) eachto wall surface complete all as specified and directed. |
| 55 | M&L for preparing new plastered surfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm).Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat long life 10 all as specified and directed. |
| 56 | M&L for applying two coats of weather proof exterior emulsion paint of standard quality and make, over a coat of white primer including preparation of old wall surfaces complete all as specified and directed. |
| 57 | M&L for two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces of any description over 10cm in width or girthincl preparation of surfaces complete all as specified and as directed. |
| 58 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), 75mm thick in plinth protection and footpath laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection. |
| 59 | M&L for 75mm thick PCC (1:2:4) type B2 (using 40mm graded stone aggregate), as in floors laid in panels and finishing the surface even and smooth without using extra cement including necessary form work complete all as specified and as directed. |
| 60 | M&L for chequered cement concrete tiles 30 cm x 30 cm x 22 to 25 mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and no pigments over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 61 | M&L for brickwork with burnt fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and directed. |
| 62 | M&L for providing & fixing factory made solid PVC cup board frame of size 50mm x 47mm (suitable for two track sliding type shutters) with a wall thickness of 5mm made out of extruded 5 mm thick prelam/plain colour PVC sheet reinforced with 19mm x 19mm MS square tube of 19 gaugethickness throughout the frame and metre cut at two cornersand jointed with 2 nos of 150mm long brackets of 15mm x 15mm MS square tubes. The door frame shall be fixed to the wall using 100mm long MS screws through the frame by using PVC fasteners. A minimum 4 nos of screws to be provided for each vertical member and minimum 2 nos of screws to be provided to the horizontal member etc.complete all as specified and dir by Engineer in charge incl dismantling of existing of cupboard. |
| 63 | M&L for providing & fixing factory made solid PVC (two track sliding type) cup board shutter (Flush type) of 24 mm thick made from co-extruded 3 layer rigid PVC foam sheet (single extruded) with density not less than 600kg/cbm outer layer (.8-1mm) thick should be of rigid PVC with density of not less than 1400kg/cbm manufactured byan ISO 9001-2015 certified company. Door should be water proof, termite proof, fire retardantand having good screw holding capacity , with all sliding and locking arrangement complete all as specifiedincl taking down the ext cupboard. |
| 64 | M&L for providing and fixing factory made PVC shelf/ partition of required size consisting of 20mm thick solid PVCsandwichwith 1mm thick plain PVC sheet on both sides suitably including dismantling old one complete all as specified and directed |
| 65 | M&L for 75mm size Hasp and staple, safety type, aluminium anodisedwith mild steel hinge pin including bolt to hinge plateand fixed with screws complete |
| 66 | S&F 75mm long Aluminium anodised, barrel tower bolts of extruded section and fixed. |
| 67 | S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples complete to wood or steel members n.exc 4 kg per sqm. |
| 68 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. |
| 69 | M&L for 25 mm thick PCC (1:2:4) type B0 (using 12.50 mm graded crushed stone aggregate) as in under layer levelling course for Bath, WC floor below tiles finished even and rough complete all as specified. |
| 70 | M&L for cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channel complete all as specified. |
| 71 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 72 | M&L for glazed colouredceramic tiles (450 x 300 x 7mm thick) on vertical surfaces such as skirting/ dado set and jointed in neat cement slurry pointed in white or coloured cement to match over 10mm thick rendering in CM (1:4) all as specified and directed. |
| 73 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 74 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.63mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications.Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- |
| 75 | One light point controlled by one, one way switch 5/6 amps. |
| 76 | One ceiling fan/ Exhaust fan point controlled by one, one way switch 5/6 amps. |
| 77 | One socket outlet 5/6 amps point on the independent board |
| 78 | One socket outlet 5/6 amps point on the same board |
| 79 | Ditto all as per serial item No 74.00 described here-in-before but wiring with 2.5 sqmm single core copper conductor for one socket outlet 15/16 amps point on the independent board complete all as specified and directed. |
| 80 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 81 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. |
| 82 | S&F socket outlet 2 in 1, 5 Pin, 5/15 amp,multipurpose 230 volt flash type complete all as specified and directed by Engr-in-Charge. |
| 83 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed. |
| 84 | S&F deluxe fan electronic regulator 230volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed. |
| 85 | S&F Ceiling rose, surface type with back plate, three terminal /PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 86 | S&F lamp holder, isolated body, with back plate suitable for batten/ angle fittings complete all as specified and directed. |
| 87 | S&F wall mounted slim LED batten 20W 4\" long, min output 120 Lumen/ watt PF>0.95, surge protection,> 4KV, THD:<10% with extruded aluminium housing, with integrated LED driver complete all as specified and directed by Engr-in- charge. |
| 88 | S&F LED luminaries 600 mm x 600 mm, 35/36 watt, min 110 Lumen/ watt PF>0.95 surge protection>4 KV, THD:<10% with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 89 | S&F LED street light fittings 35 watt min output 110 Lumen/ watt PF>0.95, surge protection>5, THD: <10%in aluminium PDC housing, toughened glass cover with IP66 protection complete all as specified and as directed. |
| 90 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCBs/ isolators complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 91 | S&F MCB, Single pole & neutral 40 amps, 240 volts, ‘C’ curve, 10 KA including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 92 | S&F MCB, Single pole, 6 to32 amps, 240 volts, ‘C’ curve, 10 KA including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 93 | M&L for Sub main wiring casing capping type with two run single core cable PVC insulated cable with6.0Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulatedcable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly anddrawing into rigidPVC casing cappingof size 32 mm medium gradesize,making good the disturbed surfacescomplete including taking down old submain wiring.NOTE : Two run of submain wiring cable alongwith one run of earth wire and casing capping shall be measured as one unit/length. . |
| 94 | M&L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/ loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and saltPCC pit (1:3:6) type C1( using 20mm graded stone aggregate) and 50mm thick RCC (1:2:4) type B0 (using 20mm graded stone aggregate) cover reinforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No. 3 of SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge. |
| 95 | S&F ceiling fan complete with blades, down rods and accessories including provision of hook for hanging ceiling fan, 230 V, 1200 mm sweep BEE star rated with Brushless direct current (BLDC) motor complete all as specified by Engr in charge. |
| 96 | M&L forstreet light bracket, made out of GI pipe (medium grade) 32mm bore, 1.2 m long bend to shape and fixing/ grouting with wall using 2 Nos 25 x 5 mm size MS FI clamps with bolts, nuts & washers complete including drilling as necessary and two coats ofAluminium paint over a coat of Red oxide primer all as specified & directed. |
| 97 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, poles, stays, cables etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 98 | Returning, filing in, including spreading, levelling, watering and well rammingin layers not exceeding 25 cm thick in any type of soil etc complete all as specified and directed. |
| 99 | Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. |
| 100 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed by Engr-in-Charge. |
| 101 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. Note:- Punned down thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I |
| 102 | Supply laying & testing cable XLPE insulated, screened, PVC bedded, galvanisedsteel striporwire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, (Earthed), grade cross sectional area 25 sqmm, 2 core. |
| 103 | M&L for laying of GI pipe light grade across road for cable protection complete of size 40mm dia complete all as directed. |
| 104 | S&F LED light fitting 1x9W/ 1X10W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size |
| 105 | Supply and layingin trenches GI water Tubing medium gradeof 25 mm dia including all fittings such as sockets, bends, elbows, Union etc. complete all as specified and as directed. |
| 106 | S&F stop valves 25mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 107 | Cutting of existing GI pipe of dia 25/ 50/ 80 mm and inserting ofTee in existing pipe for connecting new pipe complete all as specified and as directed. |