| Sl. No. | Item Description |
| 1 | Excavation in trenches n\"exc 1.5m wide and n\"exc 1.5 mtr deep for sewage pipe line and manhole, laying of cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling incl spreading, levelling watreing and well rammingh in layers n\"exc 25cm in soft/loose soil for sewage pipe line manholes sides cable etc and cleaning the site all as specified and directed . |
| 3 | Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exc 1.50m above from the starting point complete all as specified and directed. |
| 4 | M & L for Cutting/drilling the existing DI/CI GI pipes lines upto 20 mm dia, in position for inserting and including of new Tees. branches etc including excavation, returning filling , Removal , jointing , complete all as specified and directed. |
| 5 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 200 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 6 | Supply and fixing in replacement Sluice valve of size 200 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 7 | M&L for construction of PCC block walling valve pit of size 1200mmx 1200mm x1200mm(internal dimension) with precast cement concrete block of PCC 1:3:6 type-C-1 using 20mm graded stone aggregate built in CM (1:4) and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less than 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide prime complete all as specified and directed. |
| 8 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 9 | Supply and fixing in replacement Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 10 | M&L for construction of PCC block walling valve pit of size 900mmx 900mm x900mm(internal dimension) with precast cement concrete block of PCC 1:3:6 type-C-1 using 20mm graded stone aggregate built in CM (1:4) and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less than 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide prime complete all as specified and directed. |
| 11 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 100 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 12 | Note :-(a) In case of laying of CI/GI/DI pipe line is to be executed in civil area, it will be the responsibility of the contractor to obtain necessary permission for cutting of road & berm from BWSSB. |
| 13 | (b) For this purpose amount to be paid online to BWSSB, same is deemed to be included in unit quoted rate. |
| 14 | (c) The T&P like JCB, Drill Machine, Moveable Generator etc required for cutting of road shall be arranged by the contractor & no extra cost shall be paid for the same. |
| 15 | (d) After execution of work, the contractor will make good disturbed portion of road with bitumen or PCC complete as directed by Engineer-in-Charge. The cost for same is deemed to be included in the unit quoted rate. |
| 16 | Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed |
| 17 | M&L for construction of PCC block walling valve pit of size 600mmx 600mm x600mm(internal dimension) with precast cement concrete block of PCC 1:3:6 type-C-1 using 20mm graded stone aggregate built in CM (1:4) and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less than 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate of incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide prime complete all as specified and directed. |
| 18 | M & L for DI specials and fittings as per IS for spigot and socketed pipes or flanged pipe for water mains I branches lines such as bends(any type radious and angle ) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pices,single branch,Y juntion, double branch, cross, including connecting pieces one end flanged and other socket or spigot and bell mouth pices suitable for rubber joint,tyton joint up to 300 mm bore and conforming to IS-9523: 2000 complete all as specified and directed. |
| 19 | Supply and fixing in replacement Sluice valve of size 80mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 20 | S&F in replacementfoot valve (confirming to IS-4038) cast iron of size 80 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed. |
| 21 | Supply and fixing in replacement Non return valve (NRV) of size 80 mm (ISI marked), gun metal body suitable for 80 mm dia pipe line complete all specified and directed |
| 22 | M& L for disconnecting pumpsets up to 100 HP from existing platform and reconnection in the new platform after completion of platform work including connection of suction and dischagre pipe line with connecting fiitings and fixture all as specified and directed by Engineer in charge.Note: Platform work items meassured separately. |
| 23 | Demolition and dismantling Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) in situ in any type of mortar complete all as specified and directed. |
| 24 | M & L for Cement concrete type C-2, 1:3:6(40mm graded stone aggregate) cement concrete in sub-floors, sub-bases, floors and paving,100 mm thick surface finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | Material and labourfor Fabricate valve chamber coversmade out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted cover complete all as specified and directed. |
| 26 | Supply, installation, testing and commissioning starter panel box CPRI Testedof suitable sizesuitable for 3 phase 415 Volts of suitable size indoor type suitablethick CRCA sheet ofcubical type complete withwall/plinth mountedas per site requirement to accomodate to the following :-(a) 12.5 HP Fully Automatic Star Delta starter with suitable motor protection including connected accessories -01 No(b) R-Y-B indication lamp -03Nos(c) Ammeter with suitable CT-01 No(d) Voltmeter -01 No (e) Auto Manual Toggle Switch-01 No(f) ON OFF Push Botton -02 Nos(g) Trip Indication LED Lamp -01 No(h) Water Pressure Indication lamp-01 No |
| 27 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.(iii) Removing excavated material to out side MD.(iv)Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 28 | Taking down and relaying of existingserviceable GI tubing / connection in new or old positions including cleaning, cutting, threding all as directed, along with provn of new GI fittings where ever required at site of size 80 to 150mm bore complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 29 | Supply & Fix as in replacement GI tubing medium grade of size 150 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 30 | Supply & Fix as in replacement GI tubing medium grade of size 100 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 31 | Supply & Fix as in replacement GI tubing medium grade of size 80 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 32 | Supply & Fix as in replacement GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 33 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed. |
| 34 | Supply and fix 5000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed |
| 35 | Supply and fix PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 50 mm complete all as specified and directed |
| 36 | Supply and installation horizontal Open Well Submersible pump of capacity 2 HP single Phase with Control Panelstarter complete all as specified and as directed. Make : Kirloskar/KSB/CRI |
| 37 | M&L flat three core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 4 .0 Sq mm nominal areacomplete all as specified and directed. Make : Havells/Polycab/Finolex |
| 38 | Supply & Fixof GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and threading as required at site complete all as specified and directed. |
| 39 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm complete all as specified and directed. |
| 40 | Supply, installation, testing and commissioning wall mounted Starter Panelofsuitable size for 3 phase 415 Volts of suitable size out door made out of3.15mm thick CRCA sheet for outdoor panel with suitable size of angle iron frame cubical type completeincluding fixing arrangement in the wall as per site requirment to accomodate to the following :-INCOMING(a)MCCB TPN 63 Amp 16 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Digital Ammeter with suitable capacity of CT\"s- 01 No(d)Digital Voltmete -01 NoOUTGOING(a)MCB TP 20 Amp 10 KA - 02 Nos. (b)DOL Starter suitable for 2 HP -02 Nos.(c) MCB SPN 20 Amp 10 KA - 02 Nos.(d) Single Phase preventer -02 Nos |
| 41 | S & F TPN, MCB63 Amp, 415V, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete all as specified and directed Make : Legrand/ L&T/ Indo Asian |
| 42 | S&F factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 43 | Supply & Fixof GI tubing medium grade of size 40 mm bore with all fittings on wall/ trenches complete including cutting and threading as required at site complete all as specified and directed. |
| 44 | Supply and fixingSluice valve of size 80mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 45 | Cutting the existing GI pipe line of 80 mm dia for addn / altrn or taking branch connections incl making thread for inserting new Tees complete all as specified and directed. |
| 46 | Supply and fix GI Tank Nipple suitable for HDPE water tank of dia 50 mm complete all as specified and directed. |
| 47 | S&F ofUnion Both ends screwed to iron pipes, or one flange end bedded in red lead cement, and other end screwed to iron pipe, etc of size 50 mm dia pipe complete all as specified and directed. |
| 48 | S&F ofUnion Both ends screwed to iron pipes, or one flange end bedded in red lead cement, and other end screwed to iron pipe, etc of size 40 mm dia pipe complete all as specified and directed. |
| 49 | Supply and fix ofPVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 40mm complete all as specified and directed |
| 50 | Supply & Fix of GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. |
| 51 | Taking down steel gate of area n exc 16 sqm & remove old wheel track and fix new wheel track of width 12cm (total length 77m). Fix steel wheels of dia 20cm (4Nos per gate)fix the door to wheel track incl all necessary greasing, oiling etc all as specified and direcetded by Engr In Charge.Note: Gate shall be removed using mechanical way. The unit quoted rate is inclusive for removing and refixing the gate after necessary repair complete |
| 52 | Repair of door shutters for easy closing/opening(size upto 3 Sqm) including minor repair and easing/ cutting, adjustment/alignmentto openable with accessories and including taking down and refixing, tightening of hinges or changing the position of hinges,welding of hinges door to frame adjustment of tower bolts, sliding bolts with new screws etc,complete all as specified and directed. |
| 53 | Taking down chowkats or frames including shutter (without taking off shutters from the frame) area n exc. 1.5 Sqm each complete all as specified and directed. |
| 54 | Taking down chowkats or frames including shutter (without taking off shutters from the frame) area exc. 1.5 Sqm each n.exc 4 Sqm each all as specified. |
| 55 | S&F for 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, all as specified and as directed. |
| 56 | S&F 35 mm thick 2nd class hardwood factory madeplain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated board medium density, wood particle board with commercial face venees complete all as specified and as directed. |
| 57 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed. |
| 58 | S&FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heatmoulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to befitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed . |
| 59 | S &F 4mm thick figured glass, pin head type and glazing with oil putty in square n exc 0.5 sq. m in each pane all as specified and directed. |
| 60 | S&F 4 mm thick sheet glass ordinary quality and glazing complete in square nexc 0.50sqm each pane complete all as specified and directed. |
| 61 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 62 | S&Fextructedaluminium alloy handles,fabricated type anodised150mm long complete all as specified and as directed. |
| 63 | S&F aluminium anodised, barrel tower bolts of extruded section 200 mm long complete all as specified and as directed. |
| 64 | S & F butt hinges 100 mm long medium weight, cold rolled stainless steel completeall as specified and as directed |
| 65 | S&F extrutedaluminium alloy handles,fabricated type anodised100mm long complete all as specified and as directed. |
| 66 | S&F aluminium anodised, barrel tower bolts of extruded section 100 mm long complete all as specified and as directed. |
| 67 | S&F aluminium alloy sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast of extruded section 250 mm long complete all as specified and as directed. |
| 68 | S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete including taking down existing one all as specified and directed. |
| 69 | S&f in repair aluminium extruded body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed. |
| 70 | S&F Powder coated aluminium frame/shutters/ for doors/window/ventilators/ partition sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws etc complete all as specified.Make : JINDAL/HINDALCO or equivalentNote : (i) Glazing and wire mesh shall be measured and paid separetely. (ii) Item shall be paid as per weight of aluminium section.(iii)The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arrangement etc as required, which shall not be measured for arriving the weight(iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. |
| 71 | S&F floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete all as specified and as directed. |
| 72 | S&F Aluminium powder coated (min powder coating shall be 50 micron) of approved design/pattern with approved standard section and fixed to existing window frame with CP brass/stainless steel screwincl cutting the grill to proper opening size for fixing and operation of handles and fixing complete as per requirement and direction of EIC. |
| 73 | S&F 22-25mm SS curtain rod of dia ranging from 0.5 to 1mmincl brackets, holder fixed into brick/stone wall with screw,plugs etc all as specified and directed. |
| 74 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer in Charge. |
| 75 | Supply and fixing in repair of Collapsible steel gates, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed. |
| 76 | M&L Vitrified Ceramic tiles 8-10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar (1:6)complete including dismantling of existing old tiles and disposal to outside MD land all as specified and as directed. |
| 77 | M&L Vitrified Ceramic tiles 8-10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer ,15 mm thick in Cement Mortar (1:4)complete including dismantling of existing old tiles and disposal to outside MD land all as specified and as directed. |
| 78 | M&L for 25mm thick PCC 1:2:4 type B-0 using12.5mm graded stone aggregate as in flooring,finished cement concrete surface even and smooth using extra cement complete all as specified and as directed. |
| 79 | S&F in repair Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle complete all as specified and directed. |
| 80 | M & L for preparation of old or treated plastered surface and applying one coat ofoil bound distemper complete all as specified and directed. |
| 81 | M&L for preparation of old surfaces of steel any width or girth or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coat of aluminium paint complete all as specified and as directed. |
| 82 | M&L for Preparation of old painted wooden surface of any description and applying one coat of synthetic enamel paintnot otherwise described over 10 cm width or girth, complete all as specified and directed. |
| 83 | M&L Two coats of white wash on ceilings including preparation of old decorated surface complete all as specified and as directed. |
| 84 | M&L One coat of plastic emulsion paint on old/new painted walls, pillasters, cornices, etc., including necessary preparation of surfaces all as specified and as directed. |
| 85 | M&L One coat of cement based paint on old cement painted walls, pillasters, cornices, etc., including necessary preparation of surfaces all as specified and as directed. |
| 86 | M & L for preparation of newly or untreated plastered surface and applying two coats ofoil bound distemper over a coat primer complete all as specified and directed. |
| 87 | M&L Providing and applying wall care putty of 1.5mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 88 | Taking down cement plaster from old walls/cellingand raking out joints, hacking for key,scrubbing down with water built in cement mortar complete all as specified and directed. |
| 89 | Rendering 5mm thick in CM (1:3) on ceiling on fair faces of brick work or concrete surfaces & finished even and smooth without using extra cement complete all as specified and directed. |
| 90 | M&L three coats of white wash on newly plastered ceiling surface and necessary preparation of surfaces all as specified and as directed. |
| 91 | M&L for rendering 10 mm thickin CM 1:6 on fair faces of brick work or concrete surfaces of wall finished even and smooth without using extra cement complete all as specified and as directed. |
| 92 | Demolition of concrete any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 93 | Racking out joints /points in cement mortar to squared rubble masonry coursed or uncoursed and incl M&L keyed pointed in CM 1:4 for squared rubble masonary as specified and directed. |
| 94 | M&L for Raised pointing with CM 1:4 to random or polygonal rubble, uncoursed or brought upto courses complete all as specified and as directed. |
| 95 | M&Lin repairs Pre-cast PCC 1:3:6 type C1 (20 mm graded agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description as specified and directed. |
| 96 | M&L for Treatment of the sunken floor slab comprises of the following specification and all as specified and directed.Make :-Dr Fixit/ M/s Sika india Pvt Ltd/ STP Ltd/ M/s Fosroc Chemicals |
| 97 | (a) Demolition of cement concrete filling of any description in sunken portion in toilet and removing debris outside MD land. |
| 98 | (b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout (WPC shall be measured and paid separately) |
| 99 | (c) Rendering of uneven surfaces with 10mm thick in CM 1:4 mixed with integral water proofing as per manufacturer instruction. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured and paid separately). |
| 100 | (d)All junctions points of side wall spout where CI/ GI pipes are passing through shall be sealed with epoxy putty. |
| 101 | (e)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. |
| 102 | (f) Material and labourfor applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. |
| 103 | (g)Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound as per manufacturers specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately). |
| 104 | (h)Material and labourfor PCC 1:5:10 type E2, n exc 150mm thick complete all as specified |
| 105 | (j) Material and labourfor PCC 1:2:4 type B0 12.5mm thick aggregate, 50mm thick complete all as specified |
| 106 | Note for item No 96 to 105 :- Test the water proof area (ponding test) by filling water for at least 72 hours and tested for leakage, seepage to the entire satisfaction of GE. |
| 107 | Test shall be done in presence of Engineer-in-Charge. |
| 108 | The treatment shall be carried out by authorised applicator of chemicals. Cost of testing is included in the unit quoted rate above. |
| 109 | SupplyOnly integral water proofing compound complete all as specified and as directed.Make:-Dr. Fixit Pidi Proof and equivalent. |
| 110 | Material and labourfor Water proofing treatment to the sunken portion applying two coat of two component (1 part Polymer and second part cementations powder) cementations, polymer modified elastomeric, water proofing coating composed of cement, properly selected and graded aggregates, additive and acrylic emulsion polymer as a binder apply first coat of (mix and application as per manufacturer’s instructions) all over floor surface. Prepared surface and apply to vertical surface up to 15cm from tiling level, allow to dry 4 to 6 hours. Prepare for apply 2nd coat perpendicular to first coat and allow to dry 4 to 6 hours. All joints to Trap/WC/Soil pipe shall be properly sealed with ceiling compound/polymer modified mortar using Dr Fixit Pidicrete UBP or equivalent in M/s Pidilite orM/s Sika Chemical, Slope of slab shall be towards and including GI pipe 50mm dia of suitable length Spout pipe. Providing 15mm protective screed with cement mortar in 1:3 with WPC (Make : Dr Fixit LW + or equivalent in M/s Pidilite orM/s Sika Chemical) within 2 to 3 days of second coat complete all as specified as per manufacturer instructions. Make : Dr Fixit Pidfin 2K or equivalent in M/s Pidilite orM/s Sika Chemical complete all specified and directed by Engineer-in-Charge. |
| 111 | Dismantaling of cast iron / RCC/ PVC drain pipes jointed in cement mortar and taking out from trenches or from walls of any bore including fittings complete all as specified and as directed. |
| 112 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wallsbore of pipe 110 mm with PVC clamps complete all as specified and as directed. |
| 113 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls bore of pipe 75 mm with PVC clamps complete all as specified and as directed. |
| 114 | M&L 125/ 110 mm bore PVC (SWR) gully trap incl jointing with solvent cement complete all as specified and as directed. |
| 115 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid under floors bore of pipe 110 mm complete all as specified and as directed. |
| 116 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints under floors bore of pipe 75 mmcomplete all as specified and as directed. |
| 117 | S & F in repairs 75 mm bore PVC (SWR) floortrap plain with grating incl jointing with solvent cement complete all as specified and as directed. |
| 118 | Supply and fix 110mm dia PVC bend any radius complete all as specified and as directed. |
| 119 | Supply and fix 75mm dia PVC bend any radius complete all as specified and as directed. |
| 120 | S & F 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed. |
| 121 | S & F 75mm dia PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed. |
| 122 | M & L for PVC waste pipe 32 mm dia flexible with cup to fit wash hand basin waste coupling in repair complete all as specified and directed |
| 123 | S & F PVC (SWR)junction single(single T)equal or unequal with access door bore of pipe 110 mm complete all as specified and as directed. |
| 124 | S & F PVC (SWR)junction single(single T)equal or unequal with access door bore of pipe 75 mm complete all as specified and as directed. |
| 125 | S & F PVC (SWR) vent cowl 110 mm bore complete all as specified and directed. |
| 126 | Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exc 0.11 not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointedin white or coloured cement to match incl 15 mm thick screed bed in cement mortar 1:4 for layingfloor finishes complete all as specified and directed. |
| 127 | Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L forceramic coloured tiles of size 300x600x7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc complete all as specified and directed. |
| 128 | Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 129 | Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 130 | S&F in repairs vitreous china wash down water closet pan padestel pattern white including connection pipe to union of flushing cistern, seat and cover for pedestal pan, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm diawith mild steel chromoum plated hinging and \"P\" or \"S\" trap device complete all as specified and directed. |
| 131 | S&F in repairs Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum wt 60 gms) complete all as specified and directed. |
| 132 | Cutting chases to stone wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth |
| 133 | S&F in repairs brass chromium plated 2-in-1 tap 15 mm bore for fixing of health faucet complete all as specified and as directed. |
| 134 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25meter long flexible tube and ABS wall hook including making connections and fixed in positioncomplete all as specified and as directed. |
| 135 | S&F Rotational moulded polyethylene water storage tank of1000 Ltrs capacity cylindericalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed. |
| 136 | S & F in repairs 20 mm dia gun metal gate valve with Iron wheel screwed both ends for Iron pipe complete all as specified and directed. |
| 137 | S&F in rep PVC connections 15 mm size with brass nuts both side of length 600 mm complete all as specified and directed . |
| 138 | S& F in repairs 15mm dia concussive push button taps of cast copper alloy, chromium plated screwed for iron pipe and fixed complete all as specified and directed. |
| 139 | S&F in repair waste coupling 32 mm dia brass chromium plated for glazed ware sinks, basins etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed |
| 140 | S&F in repairbrass chromium plated towel rail 20mm dia, D type, 60cm long between flanges fixed with CP brass screwsincluding wooden/plastic beads complete all as specified and directed. |
| 141 | S&F in repair 15mm bib taps, fancy type chromium platedwith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 142 | S&F in repair 15mm bore stop valve concealed type cast copper alloy CP with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed |
| 143 | S&F in repair 15mm angle cock with flange cast copper alloy, chorminium plated, fancy type, screwed both ends for iron pipe or for union complete all as specified and directed. |
| 144 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 145 | S&F in repair Wash hand basin flat back 550x400mm vitreous china (white) with cantilever CI/Angle iron brackets embedded in concrete block including Brass chromium plated waste coupling 32mm bore, Waste pipe PVC 32mm bore, complete all as specified and directed. |
| 146 | S&F in repair half stall Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified and directed. |
| 147 | S&F In repair Grating doom 100mm dia of PTMT (Minimum weight 25gms all as specified and directed. |
| 148 | S&F in repairs, 10litre capacity PVC syphonic action type, flushing cistern, low level, white, with inlet, ball valve,pvc flush pipe, float and handle incl brackets and waste pipe complete all as specified and directed. |
| 149 | S&F in repairs 15 mm bore Pillar taps, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified |
| 150 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, incl nainital or similar pattern roof covering complete all as specified and directed. |
| 151 | S&F 0.50mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in lieu of screws |
| 152 | S&F Plain, galvanised, 0.50mm thick mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified. |
| 153 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 154 | M&L for Filling holes in metal sheet by means of welding/epoxy filling & replacement / refixing of exisiting bolts, nuts, washer etc all as direcetd by Engr In Charge |
| 155 | S&F Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 156 | S&F Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed. |
| 157 | M&L for Preparation of old surfaces of steel and applying two coats of synthetic enamel paintcomplete all as specified and as directed. |
| 158 | M&L for Preparation of new surfaces of steel and applying two coat of synthetic enamel paintover one coat of redoxide primercomplete all as specified and as directed. |
| 159 | M&L for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coat of aluminium paint over one coat of primer complete all as specified and directed. |
| 160 | S&F Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixingwith galvanised steel staples supplied and fixed complete to wood or steel members with welding or bolting all asspecified and directed |
| 161 | Welding in repairs n. exc 2.5cm in length and Thickness of Metal to be welded exc .9mm but not exc 20mm complete all as specified and directed. |
| 162 | M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 163 | M&L Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less,finising the surfaces fair and smooth by mechanical floater as directed.Note :RMC shall be used for casting. |
| 164 | Forming Expansion joints 65mm deep x 10mm wide by diamond saw cutter while concrete is still green and joint filled with sealing compound Grade ‘A’ complete all as specified. |
| 165 | Forming Contraction (Dummy) joints 30mm deep x 10mm wide by diamond saw cutter while concrete is still green and joint filled with sealing compound Grade ‘A’complete all as specified. |
| 166 | M&L for Machine cut Sadrahalli stone slab of 18 - 20mm thick(1 st Quality) as in floor, riser of steps, skirting, dado and pillar laid over and including 20 mm thick cement screed and (1:4) jointed in grey cement slurry mixed with pigment to match the shade of the slab and including rubbing, polishing etc complete all as specified and directed. |
| 167 | M&L 75mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate finished even and smooth witout using extra cement as in plinth protection/hard standing/sub base complete all as specified and directed. |
| 168 | Demolition of reinforced cement concrete in floors ,beams ,chajjas,landing slab in any position or height and similar suspended works (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. |
| 169 | M&Lreinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in chajjas/similar workand finishing exposed surfaces fair & even all as specified and as directed. |
| 170 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for colimns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and all as specified and directed. |
| 171 | M&L Mild steel TMT bars 6-8mm dia as in stirrups, cut to length, bent to shape required including cranking, bending spirally for hooping for colimns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and all as specified and directed. |
| 172 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) complete all as specified and as directed. |
| 173 | M&L mild steel framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 174 | Removing building materials etc to a distance of 500m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed. |
| 175 | M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paintover 10 cm width or girth, not other wise describedcomplete all as specified and as directed. |
| 176 | M&L for suspended false ceiling system using chicago metallic (E Grid) exposed suspended system, grid section size 600 mm x 600 mm, comprising of GI powder coated Main Runner of dimensions 39 mm x 24 mm x 0.8 mm thick (Thickness comprising of GI/ 0.4 + PPPCGS/0.3mm & weight of runner 1.35 kg for 3600 mm length), Cross Tee of dimensions 29mm x 24mm x 0.8mm thick and wall angle 22.2 mm x 22.2 mm x 0.65 mm thick (Thickness comprising of GI /0.4 + PPPCGS/0.3 mm & weight of Tee of 0.195 kg for 600 mm length), and Wall Angle of dimensions 22.2 mm x 22.2 mm x 3050 x 0.65 mm thick (Thickness comprisingof GI / 0.35 + PPPCGS /0.3 mm & weight of angle 0.70 kg for 3050 mm length), with and including4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system duly suspended with 2 mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof including taking down old u/s ceiling of any description complete all as specified and directed.Make : Everest or equivalent in Armstrong/ Charminar/ Ramco |
| 177 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces with 1.5mm external putty complete all as specified and directed. |
| 178 | S&F 250 to 300mm wide valley gutter (PVC) incl clamps, bends etc and fixing to the existing structure incl down pipe of dia as opening with required slope fixed all as specified and direcetd |
| 179 | M&L for Complete removal of existing water proofing treatment of any description and in any position including PCC padding any thickness and cleaning, wire brushing, watering & removal of debris outside MOD.NOTE :-Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work |
| 180 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed. |
| 181 | Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with waters to remove dusts etc. complete all as specified and directed. |
| 182 | M&L Brushing neat cement slurry with 3kg/sqm all as specified and directed. |
| 183 | M&L PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in concrete padding laid to required slope incl finishing the concrete surface fair and even without using extra cement complete all as specified and as directed. |
| 184 | M & L for 10 mm thick rendering in cement mortar (1:4) on roof surfacesfinished with WPC as per manufacturer\"s instructions, complete all as specified and directed NOTE :-Integral WPC shall be measured and paid separately. |
| 185 | Apply oil bound bitumen primer @ 0.40 Litre / Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg / Litre at 25 degree Celsius on the prepared dry roof surface complete all as specified and directed.. |
| 186 | M&L APP polymeric membrane min weighting 3.5kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric(wt not less than 150 gms/sqm laid on primed surfaces by torch application method complete all as specified and directed. |
| 187 | M&L for preparation of new surfaces of any description not otherwise described over 10cm width or girth and applying one coat of solar reflective aluminium paint @ 0.10 kg/sqm membrane surfaces complete all as specified and directed. |
| 188 | Supply only liquid waterproofing compound all as specified and directed |
| 189 | M & L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) setting in CM 1:6 work for landings, cover slabs, manholes, chajjas, water troughs, manger shleves and similar articles with plain facesand demolition of old reinforced cement concrete of any description and in any position complete all as specified and directed. |
| 190 | M & L salt glazed stone ware drain pipes of internal dia 200 mm bore grade \"A\" laid in trenches and jointed incl demolition and breaking up drain pipe (salt glazed stoneware drain pipe) set in cement concrete, complete all as specified and as directed. |
| 191 | M&L for concrete bed for 200 mm dia pipe including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C-2using 40mm graded crushed stone aggregate complete all as specified and directed. |
| 192 | Cutting into the existing manhole for connecting new drain pipe 200mm internal dia making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished even and smooth benching as required complete all as specified and directed.. |
| 193 | M&L for cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 194 | M&L PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in channel and benching of manholes etc complete all as specified and directed. |
| 195 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 196 | S&F of Powder coated aluminium frame workforpartition with one or more rebates incl Joining cleats,hooks, hangers, beadings, rubber gaskets etc,powder coating minimum thickness of powder coating 50 micronand fixed in position for making bed curtains all as per direction of Engr in Charge |
| 197 | S&F 12mm thick Veneered particle board, solid core, exterior grade, with decorative face veneers for both faces all as specified and directed. |
| 198 | Provn of work station / work bench using 16-18mm plywood with factory pressed laminate (1mm colour laminate external and fabric textured 0.5mm internal) and 1mm PVC edge binding on every edge of the frame complete all as specified and directed by Enge-in-Charge. |
| 199 | S&F Ball bearing runners 500mm Telescopic channel full load extension load capacity of 50 kgs fixed drawer all as specified and directed. |
| 200 | S&F Stainless steel handles 100mm size for drawer/ shutters all as specified and directed. |
| 201 | M&L for Complete removal of existing treatment, using mechanical sander with internal dust extraction system ,preparation of old surfaces for further coat on walls all as specified and directed. |
| 202 | M&L for priming the surfaces with 1.5mm thick wall care putty, on old plastered surfaces, prepara-tory to distempering complete all as specified and as directed. |
| 203 | M&L for preparation of primed surfaces of wall, distempering with two coats, 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. |
| 204 | Taking down carefully copper/aluminum pointwiring(light, fan,Power) completefittings such as switches, ceiling roses pendents, regulators socketslight fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of wall, floors, roofetc all as specified and directed. |
| 205 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealedrigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cableas continuous earth wire drawn with wiring and connected to common earth dolly for one light point/fan point controlled by one way5 Amps switch complete all as specified and directed. Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely. |
| 206 | All as per item No 205 but for One ceiling fan point controlled by one modular switch one way 5 Amps 5 switch. |
| 207 | All as per item No 205 but for One Exhaust/wall fan point controlled by one modular switch one way 5 Amps |
| 208 | All as per item No. 205here -in - before but for One light point controlled by two, two waymodular switches. |
| 209 | All as per item No. 205 here -in - before but for One 2/3 pin switch socket point controlled by one modular5 Amps switch on same board with other switches. |
| 210 | All as per item No. 205 here -in - before but for One 2/3 pin switch socket point controlled byone modular 5 Amps switch on Independent board. |
| 211 | All as per item No. 205 here -in - before but for One 5 pin modular switch socket outlet combination, 5/15 Amps, with cables 4 sq mm complete all as specified and directed. |
| 212 | Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 213 | Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian |
| 214 | Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 215 | Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 216 | Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 217 | S & F in repairs modular White cover plate with frame, 1 module |
| 218 | S & F in repairs modular White cover plate with frame, 2 module |
| 219 | S & F in repairs modular White cover plate with frame, 3 module |
| 220 | S & F in repairs modular White cover plate with frame, 4 module |
| 221 | S & F in repairs modular White cover plate with frame, 6 module |
| 222 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed..Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 223 | S&F in replacementfactory madepowder coated distribution board VTPN, 8 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 224 | S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBall as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 225 | S & F MCB in repair SPN 240 volts 32 Amps breaking capacity 10 KA \"C\" series complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 226 | Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 227 | S&F in repairs 36 W (WW/WH) LED surface mounted2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) all as pecified and directedMake : Philips/ Bajaj/CG/Havells. |
| 228 | Supply and fix in repairs recess mounted tiltable LED focus light fittings 9 watts complete all as specified and directed.Make: Philips/Bajaj/CG |
| 229 | S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 230 | S & F in repair and replacement TPN, MCB63 Amp, 415V, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete all as specified Make : Legrand/ L&T/ Indo Asian |
| 231 | S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBall as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 232 | S & F in repairs of ceiling rose, surface bakelite type, PVC, 65 x 50 mm isolated body with three terminals all as specified and as directed. |
| 233 | S & F in repairs Modular flush metal box 1/2 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 234 | S & F in repairs Modular flush metal box 3 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 235 | S & F in repairs Modular flush metal box 4 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 236 | S & F in repairs Modular flush metal box 6 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 237 | S & F in repairs Modular blank plate one module all as specified and directed. |
| 238 | S & F in repairs Modular fan regulator 120W, 2 Module complete all as specified Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 239 | Supply and Fix in repair switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 240 | Supply and Fix in repair shocket flush type 5 Amps240 volts complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 241 | Supply and Fix in repair shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 242 | Supply and Fix in repair shuttered switch socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian |
| 243 | S & F in repairs stepped type electronic fan regulator flush type on the phenolic laminated sheet etc. as reqd complete all as specified |
| 244 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 10 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 10 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 10 Sqmm cable along with one run of 10 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 245 | Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 246 | Supply and fixing in repair building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG |
| 247 | S & F in repairs street light bracket made up of GI tubing 32/40 mm dia light grade of length 1.0 mtr bent to a shape with 2 Nos clamp made up of 32 x 6 mm MS Flat duly painted incl nut, bolt and washer incl drilling in any description complete for fixing on wall complete all as directed. |
| 248 | S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 249 | S & F in repair MCB single pole 240 volts 6 to 32 Amps breaking capacity 10 KA \"C\" series complete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. |
| 250 | Taking down ceiling fan, sealing cable end,dismantling blades and removing fan and blades to store complete and refixing the same after repair of bldg work complete all as specified and directed. |
| 251 | Taking down of old unserviceable exhaust fan of any size complete and deposited to store yard complete all as directed. |
| 252 | Re- fixing retrieved Exhaust fan 300 mm sweep, 230/240 volt AC single phase, metal Body, 1400 RPM, with blade,frame including suitable new nuts bolts and make good the surface to match with existing surface complete all as specified and directed. |
| 253 | M & L in replacement of metal Louvers for exhaust fan 300 mm sweep with fixing arrangement all as specified and directed. |
| 254 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 2.5 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 2.5 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directedNote: (a)2 runs of 2.5 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 255 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity. Make : Halonix/Philips/CG/Bajaj |
| 256 | Supply and Fixin repair ofsurface mounted Square/Roundfor LED 18 Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed .Make : Philips/ Bajaj/ CG/Havells. |
| 257 | Taking down of existing ceiling fan complete from the position of any size complete all as specified anddirected |
| 258 | Refixingexisting serviceable ceiling fans 1200/1400 mm sweep servicing, painting. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, fillingcavities with filler after cleaning all dust etc. completeall as specified and as directed.Note : The quoted rates includes replacement of rubber bush ,hanging hook with new cotter pins etc |
| 259 | Material and Labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable(ii) For the purpose of measurementpunned thickness only shall be considered for payment. |
| 260 | Material and Labour for well burnt subclass ‘B’ bricks as mechanicalprotection forunder ground LT electric cables laidalong with length of the bricks equal to the width of the trench complete all as speified and directed. |
| 261 | Supply and laying in repair of GI pipe light grade for cable protection of size 40mm bore with fittings, complete all as speified and directed. |
| 262 | Material and labour for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian |
| 263 | Supply and laying in repair of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as speified and directed. |
| 264 | Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. |
| 265 | Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. |
| 266 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 inaccordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/S LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :- |
| 267 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA- 01 No. (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 315 Amp, 36 KA- 01No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA- 02Nos.(d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA- 01No.(e) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(g) Space for spare feeder - 01 No. Note :-(i) The Contractor Shall submit the drawing for approval before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be asmentioned in list of makes (PS). |
| 268 | Supply and fixing in replacement of aluminium strip 25x3mm fixed withinsulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc,.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed. |
| 269 | S & F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long mounting fixed to aluminium strip including drilling holes, nuts, bolts washers, Insulating mounting base for resting/ supporting of air terminals etc. complete all as directed. |
| 270 | Supply and fix PCC block of size 150 x 150 x 150mm in PCC (1:3:6) type C-1 with 20mm graded aggregate for fixing of roof conductor/air termination rod/GI strip etc all as directed. |
| 271 | Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed. |
| 272 | S & F high grade, weather resistant epoxy/DMC insulated Spacer 25/30 mm height 32/40 mm width for fixing of Copper/Aluminium/GI strip complete all as directed. |
| 273 | S & F in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long mounting fixed to copper strip including drilling holes, nuts, bolts washers, Insulating mounting base for resting/ supporting of air terminals etc. complete all as directed. |
| 274 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 275 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 276 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 277 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 278 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 279 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 280 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 281 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 282 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 283 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 284 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 285 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 286 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 287 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 288 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 289 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 290 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 291 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 292 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 293 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 294 | Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in Snaga.Note :- The contractor shall submit load bearing capacity certificate from the manufacturer. |
| 295 | S & F in repairs by Providing Earth continuity conductor or main earthing lead by providing 20 x 3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required |
| 296 | Note :- An amount of Rs 1,99,439.50 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |