Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-12-2025 |
| Sl. No. | Item Description |
| 1 | Taking down carefully window / Split AC unit of any size, any type, any capacityfrom the fitting/mountings, disconnecting power cables, drain pipes & accessories etc for repairs and refixing the AC unit and connecting up complete after carrying out necessary repairs to the entire satisfaction of the engineer in charge including transportation, complete all as specified and directed.Note :Spare parts will be measured and paid separately under relevent items. |
| 2 | M&L for servicing and cleaning of window / split type AC unit of any size, any capacity by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of thermocoal for air tightness, testing etc, complete all as specified and directed. |
| 3 | M&L for removing the unserviceable blower motor double Shaft, suitable for window type AC 1.0/1.5/2.0 Ton and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing,complete all as specified and directed. |
| 4 | M&L for removing the unserviceable Out door fan motor suitable forSplit type AC 1.5/2.0/3.0 Ton out door unit and rewinding of out door motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing,complete all as specified and directed. |
| 5 | M&L for removing the unserviceable indoor motor suitable forSplit type AC 1.5/2.0/3.0 Ton unit and rewinding of indoor door motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing,complete all as specified and directed. |
| 6 | S&F in replacement blower motor double Shaft, suitable for window type AC 1.0/ 1.5/2.0 Ton single ended or double ended shaft as per OEM make & size,complete all as specified and directed. |
| 7 | S&F in replacement Out door fan motor suitable forSplit type AC 1.5/2.0/3.0 Ton out door unit single ended as per OEM make and size,complete all as specified and directed. |
| 8 | S&F in replacement indoor motor suitable for Split type AC 1.5/2.0/3.0 Ton unit single ended as per OEM make and size,complete all as specified and directed. |
| 9 | Removing the unserviceable rotary compressor from window/Split type AC and supply and fix new compressor suitable for 1.0 Ton window/splittype A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make,complete all as specified and directed. |
| 10 | Removing the unserviceable rotary compressor from window/split type AC and supply and fix new compressor suitable for 1.5 Ton window/split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make,complete all as specified and directed. |
| 11 | Removing the unserviceable rotary compressor from window/Split type AC and supply and fix new compressor suitable for 2.0 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make,complete all as specified and directed. |
| 12 | Removing the unserviceable reciprocating compressor from window/Split type AC and supply and fix new compressor suitable for 3.0 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make,complete all as specified and directed. |
| 13 | M&L for shifting of air conditoner of any type / any capacity, any make with necessary addition / alteration to window / wall, complete all as specified and directed. |
| 14 | Dismantling of cooling (evaporator) coil for repairs of 1.5/2.0 Ton capacity window / split type AC made up of copper tubing and copper/aluminium cooling fins including brazing, welding etc replacement of copper/ aluminum tubing/fins as per site requirement, refixing in original position and testing etc, complete all as specified and directed. |
| 15 | Dismantling of condenser coil for repairs of 1.5/2.0 Ton capacity window / split type AC made up of copper tubing and copper / aluminium cooling fins including brazing, welding etc replacement of copper/aluminum tubing/fins as per site requirement, refixing in original position and testing etc, complete all as specified and directed. |
| 16 | S&F in replacement of cooling coil for window type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 17 | S&F in replacement of cooling coil for window type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 18 | S&F in replacement of cooling coil for split type AC 1.5Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 19 | S&F in replacement of cooling coil for split type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 20 | S&F in replacement of condenser coil for window type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 21 | S&F in replacement of condenser coil for window type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 22 | S&F in replacement of condenser coil for split type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 23 | S&F in replacement of condenser coil for split type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 24 | S&F in replacement of PVC drain pipe for split AC as per existing size,complete all as specified and directed. |
| 25 | S&F in replacement of starting capacitor of 50+6Mfd 50 Hz, suitable for 1.5/2 Ton A/C,complete all as specified and directed. |
| 26 | S&F in replacement of starting capacitor of 45+6Mfd 50 Hz , suitable for 1.5/2 Ton A/C,complete all as specified and directed. |
| 27 | S&F in replacement of starting capacitor of 45+2Mfd 50 Hz, suitable for 1.5/2 Ton A/C,complete all as specified and directed. |
| 28 | S&F in replacement of starting capacitor of 36+6Mfd 50 Hz, suitable for 1.5/2 Ton A/C,complete all as specified and directed. |
| 29 | S&F in replacement of starting capacitor of 36 Mfd 50 Hz,suitable for 1.5/2 Ton A/C,complete all as specified and directed. |
| 30 | S&F in replacement of starting capacitor of 80 to 120 Mfd 50 Hz, suitable for 1.5/2 Ton A/C,complete all as specified and directed. |
| 31 | S&F in replacement running capacitor 36 to 60 Mfd50Hz, suitable for 1.5/2 Ton capacity AC,complete all as specified and directed. |
| 32 | S&F in replacement of capacitor 3 to 6 Mfd ,50Hz suitable for condenser motor of 1.5/2 Ton A/C capacity,complete all as specified and directed. |
| 33 | S&F in replacement over load protector suitable for 1.5 /2 Ton A/C,complete all as specified and directed. |
| 34 | S&F in replacement starting relay box type suitable for 1.5/2 Ton capacity,complete all as specified and directed. |
| 35 | S&F in replacement of air filter pad of nylon cleanable/washable type of existing thickness for Split type A/C 1.5/2.0 ton Capacity as per existing,complete all as specified and directed. |
| 36 | S&F in replacement of front grill of window type A/C of capacity 1.5 / 2 Ton as per existing one,complete all as specified and directed. |
| 37 | S&F in replacement of thermostat suitable for 1.5 / 2 Ton capacity AC,complete all as specified and directed. |
| 38 | Material and Labour for replacement of blower Motor Blade suitable for Window Type AC 1.5/2 TR complete as per existing,complete all as specified and directed. |
| 39 | Supply and Fixing in replacement Blower for indoor split AC As per existing,complete all as specified and directed. |
| 40 | Disconnecting of PCB for repair of windowtype AC 1.5/2.0 TR including refixing in original position and testing etc,complete all as specified and directed. |
| 41 | Disconnecting of PCB for repair ofsplittype AC 1.5/2.0 TR including refixing in original position and testing etc,complete all as specified and directed. |
| 42 | Supply and fix in replacement of PCBwith remot for window type AC 1.5/2.0 TR,complete all as specified and directed. |
| 43 | Supply and fix in replacement of PCBwith remot for split type AC 1.5/2.0 TR,complete all as specified and directed. |
| 44 | S&F in replacement of indoor unit for split type AC 1.5 Ton capacity including brazing, welding fixing etc,complete all as specified and directed. |
| 45 | S&F in replacement of indoor unit for split type AC 2.0 Ton capacity including brazing, welding fixing etc,complete all as specified and directed. |
| 46 | Material and labour for replacement of copper discharge tube of size 3/8\" , duly nylon insulated,complete all as specified and directed.Note :- Only weight of copper tube shall be measured and paid. |
| 47 | Material and labour for replacement of copper suction tube of size 5/8\" duly nylon insulated,complete all as specified and directed.Note :- Only weight of copper tube shall be measured and paid. |
| 48 | Material and labour for replacement of copper discharge tube of size 1/4\" , duly nylon insulated,complete all as specified and directed.Note :- Only weight of copper tube shall be measured and paid. |
| 49 | Material and labour for replacement of copper discharge tube of size 1/2\" , duly nylon insulated,complete all as specified and directed.Note :- Only weight of copper tube shall be measured and paid. |
| 50 | Supply& fixing Insulation material for any size,complete all as specified and directed. |
| 51 | Material and labour in replacement blade of condensorfan motor (as per sample) for window type AC cap 1.5/2.0 Ton,complete all as specified and directed. |
| 52 | Material and labour in replacement outdoorblade of condensorfan motor (as per sample) for split type AC cap 1.5/2.0 Ton,complete all as specified and directed. |
| 53 | Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning of window type A/C or Split type A/C of any type, any capacity, any make,complete all as specified and directed. |
| 54 | Supply and fix in replacement of pencil type driers made in brass heavy duty suitable for window / split type AC,complete all as specified and directed. |
| 55 | Supply and fix in replacement of pin Valve /gas charging Valvesuitable for window/split type AC,complete all as specified and directed. |
| 56 | Supply & fixing in replacement single pole & neutral enclosure with two pin and earth plug and socket including MCB SP 32A,complete all as specified and directed. |
| 57 | Supply and fix in replacement 4 KVA wall mounting type electronic voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type,complete all as specified and directed. |
| 58 | Supply and fix in replacement 5 KVA wall mounting type electronic voltage stabilizer for automatic operation, single phase naturally air cooled indoor type,complete all as specified and directed. |
| 59 | Supply and fix in replacement MCB DP 32 Amps, 240 volts,complete all as specified and directed. |
| 60 | S&F in replacement Copper capillary tube any size suitable for window/split AC, complete all as specified and directed. |
| 61 | Supply and Fixing in replacement Blower for window AC 1.5/2.0 TR as per existing size, complete all as specified and directed. |
| 62 | S&F in replacement Brass Nuts (1/4\" Dead Nuts), complete all as specified and directed. |
| 63 | S&F in replacement Flair Brass Nuts (1/2\" Nuts), complete all as specified and directed. |
| 64 | S&F in repalcement Flair Brass Nuts (3/8\" Nuts), complete all as specified and directed. |
| 65 | S&F in repalcement Flair Brass Nuts (5/8\" Nuts), complete all as specified and directed. |
| 66 | S&F in repalcement Butane Cartage 414 ml Gas for Brazing/welding AC, complete all as specified and directed. |
| 67 | S&F in repalcement Bakalight Connecter (forAC Three Connection), complete all as specified and directed. |
| 68 | S&F in repalcement Brass Thimble for AC compressure (100 Pieces), complete all as specified and directed. |
| 69 | S&F in repalcement Copper Brazining Rod, complete all as specified and directed. |
| 70 | Supply only thread tape, complete all as specified and directed. |
| 71 | Supply only self adhesive tape (white Cello Tape) size 50mm X 30 mtr, complete all as specified and directed. |
| 72 | Supply only PVC insulation tape 25 mm X 25 m, complete all as specified and directed. |
| 73 | Supply and filling refrigerant mafron Gas R-22, complete all as specified and directed. |
| 74 | Supply and fillingrefrigerant gas R-410, complete all as specified and directed. |
| 75 | Supply and filling refrigerant gas R-404, complete all as specified and directed. |
| 76 | Supply and filling refrigerant gas R-32, complete all as specified and directed. |
| 77 | Material and Labour for inspecting and servicing of naturally air cooled voltage stabilizer of capacities 4 KVA / 5 KVA, 230 V, 50 Hz, single phaseby cleaning the complete unit with suitable cleaning agent and checking the serviceability state ofall the switchgears/ components such as internal transformer, relays, circuit board, selector switches, indication lamps, meters etc complete and replacing the defective spare parts and testing for proper fuctioning, complete all as specified and directed.Note : Components/ spare parts will be measured and paid separately under relevant items of Schedule \"A\"/BOQ, as \"Supply only\" however the cost of suitable wires, lugs, nuts, bolts and washers required for control wiring shall deemed to be included in quoted rate. |
| 78 | Supply only high and low voltage relay 230V, 50 Hz suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed. |
| 79 | Supply only power circuit board 230V, 50 Hz suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed. |
| 80 | Supply only voltmeter 0-300V suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed. |
| 81 | Supply only Switch piano, flush type single pole, one way 16 Amps suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed. |
| 82 | Supply only internal transformer suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed. |
| 83 | Supply only indicator lamps of required colour suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed. |
| 84 | Supply only 3 way terminal connector suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed. |
| 85 | S&F in repalcement PVC Insulated and PVC Round Sheathed three Core, 6 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts, complete all as specified and directed. |
| 86 | S&F in repalcement PVC Insulated and PVC Round Sheathed three Core, 4.0 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts, complete all as specified and directed. |
| 87 | S&F in repalcement PVC Insulated and PVC Round Sheathed three Core, 2.5 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts, complete all as specified and directed. |
| 88 | Disconnecting of PCB for indoor and outdoor unit for repair ofinverter type split AC 1.5/2.0 TR including refixing in original position after repair and testing etc, complete all as specified and directed. |
| 89 | Supply and fix in replacement of PCBwith remot for inverter type splitAC 1.5/2.0 TR complete incl testing of proper functioning of AC, complete all as specified and directed. |
| 90 | Supply and fix in replacement of out door fan motor suitable forinverter type SplitAC 1.5/2.0 Ton out door unit single ended as per existing, complete all as specified and directed. |
| 91 | Supply and fix in replacement ofindoor motor suitable forinverter type SplitAC 1.5/2.0 Ton unit single ended as per existing one, complete all as specified and directed. |
| 92 | Disconnecting of indoor and outdoorfan motor for repair ofinverter type split AC 1.5/2.0 TR including refixing in original position after rewinding motor, single phase, with super enamelled copper wire of existing gauge including replacement of gun metal bush, cleaning, greasing and connecting up all including testing, complete all as specified and directed. |
| 93 | Checking of Water cooler of any make / capacity in location and positionat any site includingnecessary servicing comprising of cleaningdrain water system, cleaning condensor ,Cleaning condenser fan motor,cleaning storage, water tank cleaning and testing for proper functioning of water cooler, complete all as speicified and directed. |
| 94 | M&L for removing of defective compressor sealed unit from water cooler storage type 150 Ltr per hours for repair, cutting supply and fixing new compressorsealed unit complete of same capacity and make of model AV-100 of Tecumesh or equivalent model of make , including instaling with existing system by brazing etc. Flushing of complete system with CO2 gas to dedect any leakage if any including charging of refrigent approved M12/134A or as per recommendation of manufacture to its full capacity including connecting and testing complete all as directd.Note- Cost of minor spares require to make the cooler functional shall deemed to beincluded in quoted rate. |
| 95 | All as per Sl item No 94.00 above but for 60/120 Ltr storage capacity with cooling capacity 60 Ltrs / hour water cooler of existing make. |
| 96 | All as per Sl item No 94.00 above but for 40/80 Ltr storage capacity with cooling capacity 40 Ltrs / hour water cooler of existing make. |
| 97 | Taking down the existing unserviceable blower motorHP-1/10 from water cooler of capacity 150 Ltrs/hrs and supply and fixing new blower motor single phase AC 230 volts of same capacity, complete all as specified and directed. |
| 98 | Taking down the existing unserviceable blower moter HP-1/16 from water cooler of capacity 60 Ltrs/hrs and supply and fixing new blower motor single phase AC 230 volts of same, capacity, complete all as specified and directed. |
| 99 | Taking down the existing unserviceable blower motor HP-1/32 from water cooler of capacity 40 Litrs/hrs and supply and fixing new blower moter single phase AC 230 volts of same capacity, complete all as specified and directed. |
| 100 | S&F in replacement starting relay suitablefor water cooler 40/60/120 /150 Ltr/hrs cooling capacity, complete all as specified and directed. |
| 101 | S&F in replacement Thermostat switch with knob for water cooler, having cooling capacity 40/60/80/120/150 Ltrs/hr, complete all as specified and directed. |
| 102 | S&F in replacement starting capacitor 40/60 Mfd oil filled 240 volt AC, complete all as specified and directed. |
| 103 | S&F in replacementdrain PVC pipe, 25 mm bore 70 cms in length with two Nos mild steel clamps necessary brass screws, complete all as specified and directed. |
| 104 | All as per item No. 103.00but size 32 mm bore suitable for 60and 150 Ltrs/Hrs water cooler and not more than 1.00 metre length. |
| 105 | S&F in replacement drain water tray made out of as per Exiting stainless steel sheet with necessary GI screws and PVC drain water connection arrangement of size not less than 25 mm dia, complete all as specified and directed. |
| 106 | S&F in replacement water storage tank top lid as per exiting steel sheetof existing shape and size for water cooler capacity 150 Ltrs, plastic sheet of appropriate thickness on one side withdoor gasket including , aluminium hinges 50 mm long 2/3 Nos andmaking good and painting with synthetic enamel paint approved colour to match the existing colour, complete all as specified and directed. |
| 107 | All as per Sl item No. 106.00 above but water cooler of capacity 120 Litres. |
| 108 | All as per Sl item No. 106.00 above but water cooler of capacity 80 Litres. |
| 109 | All as per Sl item No. 106.00 above but water cooler of capacity 60 Litres. |
| 110 | S&F in replacementrubber magnet gasketfixed with top cover of water cooler of 40/60/80/120 Ltrs storage capacity, complete all as specified and directed. |
| 111 | S&F in replacement rubber magnet gasketfixed with top cover of water cooler of 150 Ltrs storage capacity, complete all as specified and directed. |
| 112 | S&F in replacement worn out bottom base of water cooler foundation frame made out ofMS sheetfor water cooler & frame work made as per existing size including cutting welding brazing soldering , making holes for sealed unit , condenser with condensor fan motor , including painting black colour ( two coats ) synthetic enamel paint over a coat of red oxide primer and finishing, complete all as specified and directed. |
| 113 | S&F in replacementwater cooler body back sheet as per existing sheet size including two coats of synthetic enamel paint over a coat of primer, screws etc, complete all as specified and directed. |
| 114 | S&F in replacement condensor fan motor mounting stand as per existing sheet size and fixing on theexisting base, complete all as specified and directed. |
| 115 | S&F in replacement CP push cock ,15 mm bore made of brass chromium plated self closing horizontal type with CP adaptor and nipple, complete all as specified and directed. |
| 116 | S&F in replacementlock for water cooler Lid Cover including fixing etc. suitable for capecity 80 Litrs To150 Litrs, complete all as specified and directed. |
| 117 | M&L for checking of leakage in the storage water tank ofcooler of cooling capacity 40/60/80 Ltr/hour and making good by soldering/ brazing to prevent leakage spots including cleaning of water tank and testing, complete all as specified and directed.Note : work is to be carried out in existing position as and where machine is kept in defence area. |
| 118 | All as per Sl item No. 117.00 but capacity of water cooler 120 litre. |
| 119 | All as per Sl item No. 117.00 but capacity of water cooler 150 litre. |
| 120 | S&F in replacementstarting capacitor 80/100 Mfd oil filled 240 volt AC supply, complete all as specified and directed. |
| 121 | S&F in replacement starting capacitor 60/80 Mfd oil filled 240 volt AC, complete all as specified and directed. |
| 122 | S&F in replacement running capacitor of 15 Mfd oil filled, complete all as specified and directed. |
| 123 | S&F in replacement running capacitor of 10 Mfd oil filled, complete all as specified and directed. |
| 124 | S&F in replacement running capacitor of 2.5 Mfd oil filled, complete all as specified and directed. |
| 125 | S&F in replacementPVC float valve 15 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball complete with check nut / socket / GI nipple, complete all as specified and directed. |
| 126 | S&F in replacement aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/hr water cooler, complete all as specified and directed. |
| 127 | S&F in replacementaluminium fan blade for condenser fan motor suitable for water cooler having cooling capacity 60/150 Ltr/hrs water cooler, complete all as specified and directed. |
| 128 | S&F in replacement condenser unit complete suitable for 40 Ltr/hrs capacity water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and directed. |
| 129 | S&F in replacementcondenser unit suitable for 60 Ltr/hrs cap. Water cooler including gas chargin flushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and directed. |
| 130 | S&F in replacement condenser unit suitable for 150/150 Ltr/hrs capacity water cooler including gas chargingflushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and directed. |
| 131 | S&F in replacement copper filter and capillary tube of water cooler cooling capacity 40/80 Ltr/hrs, complete all as specified and directed. |
| 132 | S&F in replacement copper filter and capillary tube of water cooler cooling capacity60/ 120 Ltr per hour, complete all as specified and directed. |
| 133 | S&F in replacement copper filter and capillary tube of water cooler cooling capacity 150 Ltr per hour, complete all as specified and directed. |
| 134 | M&L for shifting/installation of water cooler any capacity, any make with necessary addition / alteration to water pipe connection complete all upto entire, complete all as specified and directed. |
| 135 | S&F in replacementGI tubing medium grade 15 mm bore with all fittings laid in trenches, floor, roof and wall and tank connectioncomplete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc, complete all as specified and directed. |
| 136 | All as per Ser items No 135 above but 20mm bore. |
| 137 | S&F in replacement15mm bore dia PVC stop cock of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90 gms), complete all as specified and directed. |
| 138 | S&F in replacement15mm bore PVC connection pipe for water cooler 450mm long, complete all as specified and directed. |
| 139 | M&L for scratching out the existing paint with emery paper and filling up the cavaties/scratch with primer and appling spray painting using synthetic enameld paint (shades as per required water cooler of capacity 150/120/80/60/40/Ltrs and anti corrosive black paint to compressure and base including genral servicing, complete all as specified and directed. |
| 140 | Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning of refrigerators/deep freezer ofany type, any capacity, any make, complete all as specified and directed. |
| 141 | M&L for removing of defective compressure sealed unit from refrigeratorsr 165Ltrs, cutting and supply and fixing new complete of same capacity of compressorsealed unit complete or equivalentmake, instaling with existing system by brazing etc. flushing of complete system with CO2 gas to detect any leakage if any including charging of refrigent approved M12 or as per recommendation of manufacture to its full capacity including connecting and testing, complete all as specified and directed. Note - Cost of minor spares require to make the equivalent functional shall deemed to beincluded in quoted rate. |
| 142 | All as per Sl item No. 141.00 but refrigerator of capacity 175litre. |
| 143 | All as per Sl item No. 141.00 but refrigerator of capacity 220litre. |
| 144 | All as per Sl item No. 141.00 but refrigerator of capacity 270litre. |
| 145 | M&L for removing of defective compressure sealed unit from Deep Freezer 310 Ltrs, cutting and supply and fixing in replacement new compressorsealed unit complete of same capacity and make of model of Tecumesh or equivalent mode of make copeland instaling with existing system by brazing etc. Flushing of complete system with CO2 gas todetect any leakage if any including charging of refrigent approved M12 or as per recommendation of manufacture to its full capacity including connecting and testing, complete all as specified and directed. Note-Cost of minor spares require to make the equivalent functional shall deemed to beincluded in quoted rate. |
| 146 | M&L for removing of defective compressure sealed unit from Deep Freezer 500 Litrs, cutting and supply and fixing in replacement new compressorsealed unit complete of same capacity and make of model of Tecumesh or equivalent mode of make copeland instaling with existing system by brazing etc. Flushing of complete system with CO2 gas todetect any leakage if any including charging of refrigent approved M12 or as per recommendation of manufacture to its full capacity including connecting and testing, complete all as specified and directed. Note-Cost of minor spares require to make the equivalent functional shall deemed to beincluded in quoted rate. |
| 147 | S&F in replacement cooling chamber for any type and make of refrigerator of capacity 220 to 270 litrs, complete all as specified and directed. |
| 148 | S&F in replacement cooling chamber for any type and make of refrigerator of capacity 165 to 175 litrs, complete all as specified and directed. |
| 149 | S&F in replacement thermostat switch with knob for refrigirater, complete all as specified and directed. |
| 150 | S&F in replacement starting relay suitable for comprssor of refrigeraters of any capacity, complete all as specified and directed. |
| 151 | S&F in replacement thermostat automatic defrast timer with knob suitable for 165 to 310 Ltrs capacity refrigerator, complete all as specified and directed. |
| 152 | S&F in replacement evaporator fan including motor suitable for 165 to 310Ltrs capacity refrigerator, complete all as specified and directed. |
| 153 | S&F in replacement evaporator fan including motor suitable for 310 to 500Ltrs capacity deep freezer, complete all as specified and directed. |
| 154 | S&F in replacementcopper caplary tube suitable for 165 to 310Ltrs capacity refrigerator, complete all as specified and directed. |
| 155 | S&F in replacement copper caplary tube suitable for 310 To 500liters cap deep freezer, complete all as specified and directed. |
| 156 | S&F in replacement door gasket of best quality suitable for 286/310 litres capacity refrigerator as per manufacturer\"s instruction, complete all as specified and directed. |
| 157 | All as per ser item No156.00 above but for 165 to 220 Ltrs capecity. |
| 158 | S&F in replacement bulb pin/screw type, 230 Volts suitable for 165/310 Ltrs capacity refrigerator, complete all as specified and directed. |
| 159 | S&F in replacement refrigerater door including necessary door springs, screws etc for 286 to 310 Ltrs capacity, complete all as specified and directed. |
| 160 | All as per ser item No159.00above but for 165 to 220 Ltrs capacity refrigerator. |
| 161 | S&F in replacement door lock with keys-2 Nos. for any capacity of refrigeratoras per sample, complete all as specified and directed. |
| 162 | S&F in replacement PVC Vegetable /Fruittray and suitable for 286/310 Ltrs capacity refrigerator complete of matching size and pattern, complete all as specified and directed. |
| 163 | S&F in replacementbottom standof refrigerator of any size, complete all as specified and directed. |
| 164 | S&F in replacementevaporator assembly with screw, jointing of tubes etc and testing of capacity 270/310 Ltrs refrigerator, complete all as specified and directed. |
| 165 | S&F in replacement evaporator assembly with screw, jointing of tubes etc and testing of capacity 220 Ltrs refrigerator, complete all as specified and directed. |
| 166 | S&F in replacement evaporator assembly with screw, jointing of tubes etc and testing of capacity 165/175 Ltrs refrigerator, complete all as specified and directed. |
| 167 | Supply and fillingrefrigerant gas R-134 A, complete all as specified and directed. |
| 168 | Taking out andrewinding of desert cooler fan motor of any make of capacity 1/5 HP with super enameled copper windingwire of appropriate size and testing and fixing after repairs, complete all as specified and directed. |
| 169 | S&F in replacement desert cooler fan motor capacity. 1/5 HP threespeed, as per existing 1 RPM single phase, bracket supporting stand, complete all as specified and directed. |
| 170 | S&F in replacement bush for cooler fan motor as per existing sample, complete all as specified and directed. |
| 171 | S&F in replacement shaftfor cooler fan motor as per existing sample, complete all as specified and directed. |
| 172 | S&F in replacement capacitor 4.00 mfd for cooler fan motor, complete all as specified and directed. |
| 173 | S&F in replacement bottom tank ofdesert coolermade out ofexisting gauge PGI sheet including necessary, painting the newsurfaces to match with existing surface outside and inside surface with approved quality paint including leakage testing, complete all as specified and directed. |
| 174 | S&F in replacement front grill ( horizontal and vertical members moveable) of the Desert Cooler made out ofexisting gauge PGI , complete all as specified and directed. |
| 175 | S&F in replacement three speed selector switch, complete all as specified and directed. |
| 176 | S&F in replacement desert cooler connection plate as per existing sample, complete all as specified and directed. |
| 177 | S&F in replacement side supporting columns to be fabricated out of existinggauges PGI sheet of suitable size, complete all as specified and directed. |
| 178 | S&F in replacement side/rearpanel made out of existing gauge PGI Sheet with suitable handles including painting to match with the existing desert cooler, complete all as specified and directed. |
| 179 | M&L for painting to old steel surfaces of desert cooler capacity up to 6000cfm with one coatof synthetic enamel spray paint (hammer tone paint) of approved colour on external surface and one coats of anti corrosive black paint inside the Body tank and side grills on internal surfaces including scraping/rubbing with wire brush on old and writing of MES No etc, complete all as specified and directed. Note : The work shall be carried out at the site / EM yard as per requirement. |
| 180 | S&F in replacement submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt, complete all as specified and directed. |
| 181 | S&F in replacement wood woolpad for desert cooler of sutable size superior quality including binding properly with GI earth wire with grill, complete all as specified and directed. |
| 182 | S&F in replacementPVC Insulated and PVC round sheathed three core, 1.0 sqmm copper conductor heavy duty cables for voltage grade upto 1100 Volts, complete all as specified and directed. |
| 183 | S&F in replacementPVC water distribution cupof one inlet and 3 outlets withMS nuts and bolts, complete all as specified and directed. |
| 184 | S&F in replacement PVC elbow suitable for Desert Cooler, complete all as specified and directed. |
| 185 | S&F in replacement PVC pipe 15 mm dia heavy duty for desert cooler pump, complete all as specified and directed. |
| 186 | S&F in replacement GI Nipple 15mm dia 6 inch longfor desert water cooler, complete all as specified and directed. |
| 187 | S&F in replacement fan blade as per exiting sizeof heavy duty mild steel for desert cooler, complete all as specified and directed. |
| 188 | S&F in replacement supporting clamps for fan motor as per exiting sizeof heavy dutyfor deser cooler, complete all as specified and directed. |
| 189 | S&F in replacement 3 pin plug top capacity 16 Amp single phase AC supply 240 Volts, complete all as specified and directed. |
| 190 | S&F in replacement 3 pin plug top cap 6 Amp single phase AC supply 240 Volts, complete all as specified and directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail