| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and not exceeding 10 sqm on plan and getting out in soft/loose soil for laying of cables, ERW pipes etc. complete all as specified and as directed. |
| 2 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm deep as in hard/soft soil complete all as specified and as directed. |
| 3 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil including spreading in low lying area and leveling complete all as specified and as directed. |
| 4 | M&L for cutting existing road/hard standing not exceed 45x60 cm in wide and depth getting out excavated material for laying of cable returning filling & well ramming watering finish surface 10 cm from top including provision of PCC 1:2:4 for repairing, including removal of surplase soil all as directed. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 6 | M&L for reinforced cement concrete nominal mix M-20(using 20 mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column, pipe support base, Electric pump set foundation with base plate etc and mass concrete, complete all as specified and directed. |
| 7 | Supply and Fix in repair for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 25 mm thick sand cushion complete all as specified and as directed. |
| 8 | M&L for taking out old ERW pipes by excavating from trenches and cutting corroded or wornout portion for repairs and refixing after carryout repairswelding/jointing and relaying in trenches after repairs including applying a coat of red oxide and the coat of post after red colour paint complete all as trenches for the 100 mm size of pipes all as specified and directed by Engr-in-charge. |
| 9 | Supplying, fixing, jointing and testing, ISI marked heavy grade, Class C, MS ERW pipe of 100 mm conforming to IS: 1239-1982, including fittings such as coupling, bends, elbow and tee screwed/flanged joints, nuts & bolts, rubber packing rings,fixed on wall, hanged with ceiling through clamps, hangers, brackets, pipe supports, U bolts on MS brackets with anchor fasteners all as directed and appliying 2 coats of synthetic enamel paint over a coat of zinc dichromate primer, etc as per the site requirement in long/short pieces all as specified and directed by Engr-in-charge.Make :- Tata/ Jindal / BST/ OswalNote: Underground pipelines are protected from corrosion and environmental factors as per IS 10221:2008 for coating and wrapping procedures and using coal tar-based anticorrosion tapes as per IS 15337:2003. The cost of pipeline wrapping is included in the quoted rate |
| 10 | Ditto all as per Item No 9 above but for 80 mm dia ERW pipe |
| 11 | S&F for fabricate supply and fix MS flat clamps made out MSFI of size 40 x 6 mm (confirming to Fe 290 Gde-165 ) including drilling hole, nut, bolts, washer and made to shape of required size ie. for 100 mm dia / 80 mm dia MS pipe all specified and as directed by Engr- in - Charge. |
| 12 | Supply and fix flanged yard hydrant/Stand post of 80 mm dia MS with double end flanged type 1.5 m height all specified and as directed by Engr- in - Charge.Make :- Tata/ Jindal / BST/ Oswal |
| 13 | Supply and fixing, Gun Metal, single outlet type fire hydrant landing valve, type B (Double head outlet)ISI marked of size 63mm dia complete with brass spindle cast iron wheel, with rubber gasket, nut,bolt etc and instantaneous coupling ISI marked, confirming to IS 5290 hydrostatic test pressure 23 kg/cm2, minimum operating pressure 7kg/cm2. Make:- NewAge / Essel / Swati |
| 14 | Supply and fix 63 mm dia 15 meter long Controlled Percolating (CP) Fire hose with jacket 100% synthetic yarn fabric reinforced conforming to IS 8423:1994 complete with male and female coupling conforming to IS 903 complete all as directed by Engr-in-charge.Make:- NewAge / Essel / Swati / Safex |
| 15 | Supply and fixing standard short size gun metal branch pipe with gun metal nozzle 16 mm dia outlet with standard male instantaneous spring lock type 63 mm dia coupling. Branch pipe and nozzle shall confirm to IS : 903-1985 as per existing make all as directed by Engineer-in-Charge. |
| 16 | Supply, fixing, fire hose cabinet box of size as per requirement but not less than 800X600X250 mm, out door type Made out from 18 Gauge MS sheet duly painted with 2 coats of red colour synthetic enamel paint over a coat of redoxide primer with double leafed glazed shutters(Glaged with 4mm thick glass) suitable for housing of 2 length of canvas hose, branch pipe, fire hose and nozzle, fire man axe, first aid hose and single outlet landing valve,including free standing stand made of of MS angle of size 40 mm X 40mm X 5 mm and including pcc foundation of required size but not less than 0.45 mtr height above ground level complete all as directed.Make :- Vijay / Winco / Ceasefire / New Age |
| 17 | S&F fire pump electrically driven horizontal end suction, centrifugal type confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for Continuous operation with nonover loading power characteristics for frequent start / stop operations with range of operation 0% to 150% of rated capacity for 40 hp, 440 V, 3 phase, 50 Hz, 70 m head 2280 LPM discharge complete all as specified and as directed. Make: Kirloskar / Beacon / Crompton Greaves / KSB / Wilo Mather & Platt / Jyoti / V Guard |
| 18 | Supply and fix Galvanized Iron (GI) wire of size 4mm, including necessary welding/brazing, cutting to required lengths, and taking down of old/damaged strips as required at site, complete all as directed. |
| 19 | Supply & Fix fully automatic star delta starter suitable for 40 HP, 440 volt, 3 Ph Elect Motor with Single Phase Protection feature conforming to IS -13947 making electrical connection properly complete all as specified and as directed. Make: Lauritz Knudsen / C & S / Schneider / CROMPTON |
| 20 | Supply and fix GI slotted-type cable trays of size 100mm x 50mm x 2mm, including necessary fabrication and installation using MS angles, channels, flats, etc., as supports. All MS supports shall be given one coat of red oxide primer and two coats of synthetic enamel paint of approved colour, complete all as specified and directed. |
| 21 | M & L for Earthing complete with GI earth plate electrode of 600mm x 600mm x 6mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire of size4 mm diameter as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete as specified and directed by the engineer-in-charge. Notes: (i) The cost of GI earth continuity conductor with GI pipe 40mm medium grade upto 7.5m is deemed to be included in r/o above item (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item.Note: (1) 7.5 RM GI wire in deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately (2) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate.(4) The Execavation shall be done manually by man power, the quoted rate is inclusive of digging out roots.(5) The quoted rate is deemed to be inclusive of removal of the excess material from the work site. |
| 22 | Supply and Layingor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including necessary connection and providing cable lugs as required all as specified. Note : Cable shall be clamped on wall. |
| 23 | S&F sluice valve 80 mm bore, cast iron body, flanged drilled end, conforming to IS-14846, ISI marked, class PN 1.6, reselient seating as well as metal seating Fusion bonded epoxy coating including all joints with rubber gaskets, bolts and nuts, washers, iron wheel including any addition / alteration for fixing required complete all as specified and as directed.Make :- Kirloskar / Leader / Kartar / Upadhyay |
| 24 | S&F sluice valve 100 mm bore, cast iron body, flanged drilled end, conforming to IS-14846, ISI marked, class PN 1.6, reselient seating as well as metal seating Fusion bonded epoxy coating including all joints with rubber gaskets, bolts and nuts, washers, iron wheel including any position and any addition / alteration for fixing required complete all as specified and as directed.Make :- Kirloskar / Leader / Kartar / Upadhyay |
| 25 | S&F sluice valve 150 mm bore, cast iron body, flanged drilled end, conforming to IS-14846, ISI marked, class PN 1.6, reselient seating as well as metal seating Fusion bonded epoxy coating including all joints with rubber gaskets, bolts and nuts, washers, iron wheel including any position and any addition / alteration for fixing required complete all as specified and as directed.Make :- Kirloskar / Leader / Kartar / Upadhyay |
| 26 | S & F cast iron Foot valve 100 mm, Ball type with flange joint model B-05 (N) conforming to IS with MS nuts bolts, washer, rubber gasket etc., any pattern as approved including any position and any addition / alteration for fixing required with testing complete all as specified and as directed.Make : KIRLOSKAR / UPADHAYA / LEADER / ZOLOTO |
| 27 | Supply and fixing of 100 mm dia strainer for suction including necessary fittings, flanges, gaskets, nut-bolts, washers, cutting and welding as required, making proper alignment and connections including any position and any addition / alteration for fixing required with testing complete in all respects as per site requirement and engineer-in-charge direction.Make :- Kirloskar / Leader / Kartar / Upadhyay / Zoloto |
| 28 | Supply, installation, testing and commissioning of Cast Iron Y-Type Strainer, 80mm NB, PN 16 with flanged ends, fitted with SS 304 perforated screen (3 mm), having large screening area for high efficiency, streamlined body for minimal pressure drop, suitable for water and non-corrosive fluids,Hydrostatic test pressure for shell is 24 kg/cm², and max. working pressure up to 16 kg/cm²g,including any position and any addition / alteration for fixing required with testing complete in all respects as per site requirement and engineer-in-charge direction.Make :- Kirloskar / Leader / Kartar / Upadhyay / Zoloto |
| 29 | Supply, installation, testing and commissioning of Bronze Ball Valve with Screwed Female Ends (IS 554 / BS 21 / ISO 7), Full Bore Two-Piece Design, Quarter Turn Lever Operated, Stainless Steel Ball, PTFE Gland Packing and Seats, Hydrotested at 25 kg/cm²g (Shell) and 16 kg/cm²g (Seat), suitable for Water and Oil up to 220°C installed at any position and any addition / alteration for fixing required complete all as specified and as directed.Make :- Kirloskar / Leader / Kartar / Upadhyay / Zoloto |
| 30 | Supply and fix Cast Iron Non Return valve of size 80 mm dia with gun metal seat threaded type ISI marked including dismantling old unserviceable NRV 50 mm bore complete all as specified and directed.Make : KIRLOSKAR / UPADHAYA / LEADER / ZOLOTO |
| 31 | Supply and fix Cast Iron Non Return valve of size 100 mm dia with gun metal seat threaded type ISI marked including dismantling old unserviceable NRV 50 mm bore complete all as specified and directed.Make : KIRLOSKAR / UPADHAYA / LEADER / ZOLOTO |
| 32 | Supply and fix Cast Iron Non Return valve of size 150 mm dia with gun metal seat threaded type ISI marked including dismantling old unserviceable NRV 50 mm bore complete all as specified and directed.Make : KIRLOSKAR / UPADHAYA / LEADER / ZOLOTO |
| 33 | Supply and fixing brass Air release valve of size 20 mm dia including all necessary fittings required for fixing complete all as specified and directed. Make :- Kirloskar / Leader / Kartar / Upadhyay / Zoloto |
| 34 | Supply and installation of Neoprene Single Arch Flexible Connectors, molded type, suitable for absorbing vibrations, noise, thermal expansion, and pipe misalignment, with high pressure rating, in sizes ranging of 80mm NB installed at any position and any addition / alteration for fixing required complete all as specified and as directed. Make: Easyflex |
| 35 | Supply and fix Pressure gauge of4\" dial 0-14 kgs rating with ball valve including taking up / down old unserviceable pressure gauge from any position and any addition / alteration for fixing required complete all as specified and as directed. Make: FIEBIG/ H. GURU/ BAKER MERCER/ DANFOSS |
| 36 | \"Supply and fixing of four-way Fire Brigade Inlet / Collecting Head, ISI marked as per IS: 904, made of gunmetal body, suitable for design pressure up to 24 Kg/cm² and operating pressure of 7 Kg/cm², provided with 63 mm dia gunmetal instantaneous inlets with built-in non-return valves (NRVs), flanged type, suitable for installation on 150 mm dia fire hose pipeline, complete in all respects and all as specified and directed. |
| 37 | M&L for renewal of valve pit of size up to 80 cm x 80 cm x 80 cm (internal diamension), stone / brick construction including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, PCC in foundation for mix (1:2:4) type D2 brick mansonary in cement mortar (1:4) rendering 12 mm duck in cement mortar (1:4) internally ,finished even and fair and polishing flush externally as the work proceeds in the same mortor. Mild steel angle iron 40 x 40 x 6 mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all exposed MS work with two coats of synthetic enamel paint of the that as approved by the Engineer - in - charge over a coat of red oxide primer and painting all the MS embeded in PCC with two coats of black bitumenous paint complete all as specified. |
| 38 | Supply, design, fabrication, and installation of an illuminated schematic layout signboard of size 1.5 meters x 1.5 meters, made of high-quality PVC acrylic sheet, complete with LED backlighting. The signboard shall display a schematic layout of the Fire Main Line System and Fresh Water Line System at B Camp including ERW/GI/CI/DI pipes, control valves, and associated components, with provisions for hanging at the specified locations. The contractor shall be responsible for the following:1. Trace existing ERW, GI, CI, and DI lines, including control valves and associated systems of respective area to prepare an accurate layout diagram.2. Submit the traced layout as a draft for approval by the Engineer-in-Charge before fabrication.3. Fabricate the signboard using a durable PVC acrylic sheet, suitable for both indoor and outdoor use.4. Ensure the diagram is printed with high-definition graphics and labels for clarity and long-term readability.5. Incorporate LED backlighting or other suitable illumination for visibility during day and night.6. Provide all necessary mounting arrangements for securely hanging the board at the designated locations.7. Submit a traceable or CAD-format version of the schematic diagram along with the final installed board for reference.8. A one-year warranty covering defects in material, workmanship, and illumination performance. |
| 39 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of 1.5Ton capacity |
| 40 | M & L forpoint wiring complete with proper colour coding with 1100 Volts grade, 4.0 Sqmm PVC insulated FRLS, unsheathed, wire confirming to IS-694, Part II, ISI marked with multistranded copper conductor drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc,for mounting modular switches, sockets, fan regulators etc, also including 4.0 Sqmm, PVC insulated, FRLS unsheathed, 1100 Volts multistranded copper conductor green colour as contineous earth wire connected to common earth dolly for one light point/fan/bell point controlled by one way switch, complete all as specified and directed. Note : Rates included for concealed cutting as required at site without any damage and making good in CM 1:4 and matching the surface as required 2 all screws and washer for point wiring shall be Stainless steel. Nothing is extra shall be admisible on this account Make: Benlo/ Polycab/ KEI/ Anchor(Panasonic) |
| 41 | Supply and fixing in repairsSheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 20 Amps 240 Volts.Make: Schnieder/Legrand/ C&S/ L&T |
| 42 | Supply & Fix MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs The DB Shall be of Make -Indoasaian/Legrand/ABB/Schnider |
| 43 | Supply and fixing SPN 32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.Legrand/L&T/Schnider |
| 44 | Supply and fix copper tube of size 1/4\" bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air conditioners complete all as specified and directed. |
| 45 | Supply and fix copper tube of size 5/8\" bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air conditioners complete all as specified and directed. |
| 46 | Supply and fix PVC drain pipe of size 5/8\" bore for supply pipes for air conditioners complete all as specified and directed. |
| 47 | Supply and fix Heavy duty Water Proof Powder coated mounting bracket for installation of outdoor unit of air condiioner made out of 2 mm thick high grade steel with suitable fastener, MS nuts, bolts M8 x 45mm, washer, bolt M8 x 30mm nut, bolts & washers etc. duly painted complete set all as specified and directed.Make :- Companion Sleek, Aircool Sales Corporation or equillant make. |
| 48 | M&L for sub mainwiring with 4 core 4.0 sq. mm with 2 core 2.5 sq. mm earth wire PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughPVC concealed conduitwith and includingPVC insulated 4 core 4.0 sq. mm with 2 core 2.5 sq. mm earth wire copperconductoras continous earth wire in greencolour connected to commonearth dollyincluding taking down old unserviceable submain wiring complete all as specified and as directedNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.Make of wire : KEI/ BENLO/ Polycab/ Anchor(Panasonic) |
| 49 | M&L for earthing using GI earthing strip 25 x 4mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deepbelow ground level connection to and including GI strip of size 25x4mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed. |