| 1 | Taking down cement plaster on brick/stone walletcincluding raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 2 | M&L for Rendering using Ready mix plaster 12 mm thick of approved make equivqlent to CM 1:4 or above on fair external faces of brick work,block masonryor concrete surfaceswith mixing water proofing compound as per manufactures instructions on walls and finishing even and smooth complete all as specified and directed. (Note: WPC will be measured and paid seperately) |
| 3 | M&L for Rendering 10mm thick in (1:3) cm on fair faces of ceiling and finishing even and smooth without using extra cement complete all as specified and directed. |
| 4 | M&L for Rendering10mm thick in CM 1:6 to fair faces of brick surface or concrete surface finished even and fair without using extra cement all as specified and directed. |
| 5 | Supply only liquid water proofing compound. |
| 6 | M & L for preparation of new plastered external surfaces and applying Two coats of 100% Premium acrylic emulsion paint ( Weather Proof) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as directed. |
| 7 | M & L complete removal of existing treatment of external surfaces and applying Two coats of 100% Premium acrylic emulsion paint ( Weather Proof) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as directed. |
| 8 | M & L for prepartion of newly plastered surfaces of wall and priming plastered surfaces with alkali resistant primer and applying two coats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as permanufacturer\"s specification over 3mm thick putty (in three layers) complete all as specified and directed. |
| 9 | M & L for complete removal of existing treatment of old surfaces of wall and applying distmepring with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved munufacutre of required shade and colour over 3 mm wall care putty in three layers complete as per munufacuters specification two or more coat all as specified and directed. |
| 10 | M & L for prepartion of newly plastered surfaces of ceiling andapplying two coats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as permanufacturer\"s specification over 3mm thick putty in three layers complete all as specified and directed. |
| 11 | M & L for complete removal of existing treatment of old surfaces of ceiling andapplying two coats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as permanufacturer\"s specification over 3mm thick putty in three layers complete all as specified and directed. |
| 12 | M & L for complete removal of old surfaces of walls and applying two coat of synthetic enamel paint over 3 mm wall care putty (in three layers) on walls complete as per munufacuters specification two or more coat all as specified and directed. |
| 13 | M & L for Preparation of old painted steel/iron surfaces of any description having width/girth exceeding 10cm and applying one coat of synthetic enamel paint for material and labour complete. |
| 14 | Excavation in trenches n.exc 1.5m wide & n.exc 1.5m depth for fdn etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in hard/dense soil. |
| 15 | M&L for returning, filling incl spreading levelling watering and well ramming in layers n.exc 25 cm as in hard/dense soil. |
| 16 | Removing excavated surplus soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 17 | Demolition of cement concreteof any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 18 | M&L for Brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete. |
| 19 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specifed and directed. |
| 20 | M&L for 10mm thick rendering in CM (1:6) on fair surfaces of brick work or concrete surfacesfinished even and smooth without using extra cement, complete all as specified and directed. |
| 21 | M&L for hardcore of gauge n.exc 0.63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface of a broken stone or boulders complete all as specified and directed. |
| 22 | M&L for 100mm thick PCCtypeC-2 (1:3:6) using 40mm graded agg as inflooring finished even and smooth w/o using extra cement . |
| 23 | M& L hand cut kota stone slab flooring 20-22mm thick over cement screed base laid andjointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including screed bed 15 mm thick in cement mortar (1:4), including rubbing and mirror polishing complete all as specified and directed. |
| 24 | M& L hand cut kota stone slab flooring 20-22mm thick as in vertical surface such as skirting and dado jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including rendering of 10 mm thick in cement mortar (1:4), including rubbing and mirror polishing complete all as specified and directed. |
| 25 | S&F PVC(SWR) floor trap, plain with grating including jointing with solvent cement 75mm outlet |
| 26 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors110mm bore |
| 27 | S&F PVC (SWR) bend any radius 110mm bore |
| 28 | M&L for Reinforced concrete 150mm dia pipes, class NP2, laid in treches & jointed in cm 1:1 complete with collars |
| 29 | M&L for concrete bed to drain pipes 150mm dia using cement concrete 1:4:8 type D2 including packing under and haunching against the sides of pipes after they are laid and tested in. |
| 30 | M & L Joist, channel, angle, or tee sections, fixed independently in vertical Posts, without connecting plates, etc.Fe 410-W (Gde E250) quality-A |
| 31 | S&F rolled section as in main & cross beam , hip and jack rafter &purlins where connected to common rafter and running rails with cleats and connecting plates etc complete using Fe 410 -W (Gde- E- 250) quality- A all as specified and directed. |
| 32 | M&L two coats of synthetic enamel paint over one coat of red oxide primer on new steel surface after necessary preparaton of surface over 10 cm in width or girth complete |
| 33 | S & F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 34 | M& L for sand cushioning for laying paver block. |
| 35 | M&L for machine pressed precast concrete interlocking paver block 60 mm thick rubber molded any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment over sand complete all as specified and directed. |
| 36 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 37 | S & F 15mm dia medium grade GI tubing with all fitting and fixed to wall, ceiling or laid in floors etc complete all as specified and directed. |
| 38 | S & F 20mm dia medium grade GI tubing with all fitting and fixed to wall, ceiling or laid in floors etc all as specified and directed. |
| 39 | S & F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed |
| 40 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming Fe 410 -W (Gde- E- 250) quality. |
| 41 | S&F rotational moulded polyethylene cylindrical vertical with closed top water storage tank double layered 1000 Ltr capacity, hoisted and fixed in position on new or existing foundation and makingGI tubing inlet or outlet connection. |
| 42 | S & F in repairs 20 mmBrass valves ,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed |
| 43 | M& L for Steel work in tubular frames including special shaped washer and ball bearing etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as directed. |
| 44 | M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 10cm long complete all as specified and directed. |
| 45 | Dismantling roof treatment of any description including cement mortar bedding(But not backing)cleaning the surface by blowing,washing and rubbish off the premises complete all as directed.(a) M&L for10 mm thick rendering onfair faces of brick works / Concrete surfaces finished even and smooth without using extra cement in cement mortar 1: 3complete all as specified and as directed(b) M&L for priming evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sq.m including cleaning the surface.(c) M&L App based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforment with polyster non woven fabric (wt reinforcement not less than 150 gms/sqm) laid on primed surfaced application complete all as apecified and directed (Primer should be measured and paid as per Item above).(d) M&L applying two coat of Aluminium paint over APP Membrane complete all as apecified and directed. |
| 46 | Cutting out cracks to V section in existing roofs or terracing ,cleaning out ,wetting, grouting with cement and sand slurry 1:3 |
| 47 | M&L for 25mm thick PCC type B0 (1:2:4) using 12.5 mm graded crushed aggregate in padding concrete and the like all as specified and directed. |
| 48 | M&L for 5mm thick rendering on concrete surface of ceiling in CM 1:3and rendering is to be finished even and smooth with out using extra cement |
| 49 | M & L three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces. |
| 50 | M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified |
| 51 | M&L for preperation of new concrete /plastered surface of any description, two coat of destemper oil emulsion over a coat of primer complete all as specified and as directed complete all as specified and as directed. |
| 52 | S&F Aluminium Powder Coated sliding window two track with outer frame & two glass shutters using aluminium powder coated section aluminium cleat, PVC track, bearing, handle lock rubber beading etc complete fittings as approvedNote :- Size of aluminium section shall be under -(i) Two track top and vertical- Jindal main 2010. section no 20621 or equivalent as approved by GE(ii) Two track bottom section- Jindal main-2010 section 20620 or equivalent as approved by GE(iii) Shutter vertical section- Jindal main-2010 section 20604 or equivalent as approved by GE(iv) Shutter top and bottom- Jindal main-2010 section 20604 or equivalent as approved by GE(v) Shutter vertical middle (interlock)- Jindal main-2010 section 20605 or equivalent as approved by GE(wiremesh and glass measured separatly) |
| 53 | S & F 4.8mm thick Sheet black glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each paneall as specified and directed by Engr -in-Charge. |
| 54 | M&L for complete removal ofexisting finishes from old plastered surface of wall , Stone, Concrete of any description all as specified and as directed. |
| 55 | M & L two coats of oil bound distemper over a coat of primer on newly plastered walls surfaces with 1mm thick puttyincluding preparation of surfaces. |
| 56 | Demolition of cement concrete in ground floor and pavings n\"exc 15cm thickness (below or above ground level complete all as specified and as directed). |
| 57 | M & L for 25mm thick PCC 1:2:4,type B-0, (using 12.50 mm graded stone aggregate) as in under layer of tile flooring & finishing the surfacesrough to receive screed bed complete as specified and directed. |
| 58 | M&L for machine cut mirror polish kota stone slab flooring 20-25mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. |
| 59 | S&F 8mm thick rubber mat for flooring anti skid and water resistance Heavy duty all as specified and directed. |
| 60 | M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified |
| 61 | M&L for Cement concrete type B1 1:2:4 (20mm graded aggregate) lintel upto 1.5m clear span cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 62 | S&F Steel rolling shutters with thicknes of each laths of 1mm thick,with out ball bearing ,as specified,including top cover anchoring rod ,hasp and staple and one shop coat of primer;erected in position as indicated,complete:push pull or manual type complete all as specified and as directed |
| 63 | M&L Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof ,Brackets for Valley gutters ,including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 |
| 64 | S&F for Mild steel ,plain black sheet of minimum 0.8mm thickness for Hoods cover for Rolling shutters;cladding to door shutters/Hangar doors ; water tank platforms etc with plain 40mm lap joints or welded/riveted seams including ,bending, turning up, mitred angles , stopped ends,outlets,etc. as required all as sprcified and directed by Engr-in Charge. |
| 65 | M&L for Cutting holes in brick/stone walls in mud/cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4Type B-1 as required all as specified and directed by Engineer-in-Charge. |
| 66 | S&F of Collapsible steel gates side hung, considering of channel pickets , pivoted flat bars, top and bottom runners,handles etc, as specified,errected in position and securing runners with hold fasts and brackets, complete all as specified and directed by Engr-in- Charge |
| 67 | M&L Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof ,Brackets for Valley gutters ,including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 |
| 68 | M&L for Cutting holes in brick/stone walls in mud/cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4Type B-1 as required all as specified and directed by Engineer-in-Charge. |
| 69 | Excavating in post holes Soft/disintegrated rock (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified |
| 70 | M & L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in foundation filling and mass concrete |
| 71 | M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified |
| 72 | M&L for 10mm thick rendering onfair faces of brick works finished even andfairwithout using extra cement in cement mortar 1: 4 complete all as specified and as directed |
| 73 | M & L three coats of white wash on newly plastered wall surfaces including preparation of surfaces. |
| 74 | M & L for 75 mm thick PCC 1:4:8 type D-2 using 20mm graded aggregate as sub flooring all as specified and direcetd. |
| 75 | M&L for 100mm thick cement concrete type B-1,1:2:4 (20mm graded aggregate) as in flooring & finish surface smooth all as specified and directed |
| 76 | S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 graded St 240 all as specified and directed.(Eaves Baords) |
| 77 | Supply and fixing mild steel work as in angle iron, flat iron of any size for post and struts as in fencing including, cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron filletsfor securing wire mesh ,chain link fencing etc including all necessary drilling bolting or riveting etc and/or fixing with screws, bolts etc. and similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed. |
| 78 | Fixing only Chain link fencing including line wires, any mesh size and type to any type of standards,rails, straining bolts,etc.including provision of binding wire. |
| 79 | Supply only chain link MS galvanised fencing of weight not less than 3.5 Kgs per sqm and size as directed by Engr-in-charge. |
| 80 | Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and capingwith all fittings/fixture etc andsurface typePVC box, cover plate all as specified and directed by Engr-In-Charge.(a) OneFan point controlled by one switch. |
| 81 | S&F Piano switch flush type, 5A, one way, complete all as specified and directed. |
| 82 | S&F Fan regulator electronic type, 230V, 100W complete all as specified and directed. |
| 83 | S&F Ceiling fanscomplete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC)all as specified and directed. |
| 84 | M&L for wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100V grade conforming to IS 694 drawn through steel ERW conduit flame proof, heavy grade ISI marked including necessary conduit accessories surface on wall, ceiling etc including 1.5 sqmm PVC insulated flame retardant copper conductor as in continious earth wire for FLP light/fan point controlled one way metal clad switch of 5A capacity complete all as specified and directed. |
| 85 | S&Fswitch flame proof, rotary type with termination box in LM6, 16A single pole 250V complete all as specified and directed. |
| 86 | S&F LED light fitting 2x16 W flame proof CMRI certiied recommended for gas/vapor group of IIA & IIIB, Zone 1&2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver holders connector etc complee with al accessories prewired an including connecting up with three core flexibe copper conductor cable with suitable size. |
| 87 | Supply and fix Flameproof Exhaust fan, AC Single phase 230 V of size 400 mm sweep with Blade & Frame and louvers complete al as specified & directed |
| 88 | M&L for cutting hole of suitable size for exhaust fan of given size and making good existing wall complete all as specified and directed by Engr-in-Charge |
| 89 | Supply and fixing Flameproof Ceiling fan complete with blades, down rods, regulator and accessories 230 V, 1200 mm sweep with Blade & Frame and louvers complete al as specifited & directed |
| 90 | Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete al as specified & directed |
| 91 | M&L for sub main wiring with three single core 4 Sqmm PVC insulated FR multistranded flexible copper conductor cable 660/1100 volts grade with and including stove enamelled steel conduit laid over the surface of structures/wall/ceilling the cable shall be drawn in through PVC conuit and connected to DB, equipments, connector,common earth dolly all as specified in wall,cailing, steel structures of buildings with necessary saddles & spacers and as directed |
| 92 | S&F MCB DB SPN 08 way IP43 IK-09 with metal door suitable for housing of MCBs complete all as directed by Engineeroin-Charge |