Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-12-2025 | Third extension of due date for entrusting of Annual Maintenance Contract and supply of spares for maintenance of 355 Nos. of A.C. units installed at Legislative Assembly, Chief Secretariat and Main office, Electricity Department, Puducherry | Date | 06-01-2026 |
| 2 | 18-12-2025 | Second extension of due date for Entrusting of Annual Maintenance Contract and supply of spares for maintenance of 355 Nos. of A.C. units installed at Legislative Assembly, Chief Secretariat and Main office, Electricity Department, Puducherry | Date | 29-12-2025 |
| 3 | 09-12-2025 | First extension of due date for Entrusting of Annual Maintenance Contract and supply of spares for maintenance of 355 Nos. of A.C. units installed at Legislative Assembly, Chief Secretariat and Main office, Electricity Department, Puducherry | Date | 18-12-2025 |
| Sl. No. | Item Description |
| 1 | Entrusting of Annual Maintenance Contract of A.C. Units |
| 2 | Legislative Assembly, Puducherry |
| 3 | Monthly maintenance charges for Cassette / Vertical type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 4 | Monthly maintenance charges forCassette / Vertical type inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 5 | Monthly maintenance charges for split type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 6 | Monthly maintenance charges for split type inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 7 | Total monthly maintaintence charges for 118 Nos. of A.C. Units |
| 8 | Total Annual maintaintence charges for 118 Nos. of A.C. Units |
| 9 | Details of spares required for maintenance of Cassette / Vertical type non-inverter A.C. Units |
| 10 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Cassette / Vertical type non-inverter A.C. unit |
| 11 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 12 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 13 | Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 14 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 15 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 16 | Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 17 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 18 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 19 | Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 20 | Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 21 | Provision of new Reciprocating compressor(Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 22 | Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) Less buy back value of old Compressor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 23 | Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) Less buy back value of old Compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 24 | Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) Less buy back value of old Compressor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 25 | Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 26 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 27 | Replacement of condensing coil Less buy back value of old condensing coil (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 28 | Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 29 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 30 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 31 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 32 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 33 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 34 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 35 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 36 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 37 | Fan motor rewinding and fan bush replacement (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 38 | Fan motor rewinding and fan bush replacement (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 39 | Fan motor rewinding and fan bush replacement (2.5 Ton) forCassette / Vertical type non-inverter A.C. unit |
| 40 | Replacement ofindoor Blower (1.5 Ton) for Cassette / Vertical type non-inverter A.C. unit |
| 41 | Replacement ofindoor Blower (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 42 | Replacement ofindoor Blower (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 43 | Replacement of fanoutdoor blade (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 44 | Replacement of fanoutdoor blade (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 45 | Replacement of fanoutdoor blade (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 46 | Replacement of digital remote board (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 47 | Replacement of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 48 | Replacement of digital remote board (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 49 | Repairing of digital remote board (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 50 | Repairing of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 51 | Repairing of digital remote board (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 52 | Replacement of air filter (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 53 | Replacement of air filter (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 54 | Replacement of air filter (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 55 | Replacement of single pole contactor (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 56 | Replacement of single pole contactor (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 57 | Replacement of single pole contactor (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 58 | Replacement of fan capacitor 4-10 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 59 | Replacement of running capacitor 36 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 60 | Replacement of running capacitor 45 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 61 | Replacement of running capacitor 50 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 62 | Replacement of running capacitor 50+5 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 63 | Supply and fixing of MCB breaker 20 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 64 | Supply and fixing of MCB breaker 25 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 65 | Supply and fixing of MCB breaker 32 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 66 | Supply and fixing of metal glad plug and socket with MCB for Cassette / Vertical type non-inverter A.C. Unit |
| 67 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Cassette / Vertical type non-inverter A.C. Unit |
| 68 | Shifting of Cassette/Vertical A.C. one location to another location including gas charge (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 69 | Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 70 | Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 71 | Replacement of drain pipe for Cassette / Vertical type non-inverter A.C. Unit |
| 72 | Copper pipe with insulation(1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 73 | Copper pipe with insulation(2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 74 | Copper pipe with insulation (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 75 | Thermal insulation with tape for Cassette / Vertical type non-inverter A.C. Unit |
| 76 | Complete rewiring kit for Cassette / Vertical type non-inverter A.C. Unit |
| 77 | Tinkering charge for outdoor unit for Cassette / Vertical type non-inverter A.C. Unit |
| 78 | Stabiliser repairing charge for Cassette / Vertical type non-inverter A.C. Unit |
| 79 | Supply of hand remote for Cassette / Vertical type non-inverter A.C. Unit |
| 80 | Replacement of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit |
| 81 | Repairing of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit |
| 82 | Swing Motors for Cassette / Vertical type non-inverter A.C. Unit |
| 83 | Dummy valve, ยผ, ยฝ, 5/8, 3/8 for Cassette / Vertical type non-inverter A.C. Unit |
| 84 | A/C Metal clad plug Top for Cassette / Vertical type non-inverter A.C. Unit |
| 85 | A/C Metal clad Socket for Cassette / Vertical type non-inverter A.C. Unit |
| 86 | 15A modular 3 pin Plug top for Cassette / Vertical type non-inverter A.C. Unit |
| 87 | 15A modular 3 pin socket for Cassette / Vertical type non-inverter A.C. Unit |
| 88 | Room Sensor for Cassette / Vertical type non-inverter A.C. Unit |
| 89 | Coil Sensor for Cassette / Vertical type non-inverter A.C. Unit |
| 90 | Replacement of outdoor Base plate for Cassette / Vertical type non-inverter A.C. Unit |
| 91 | A.C. unit pump down service for Cassette / Vertical type non-inverter A.C. Unit |
| 92 | Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit |
| 93 | Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit |
| 94 | Details of spares required for maintenance of Cassette / Vertical type inverter A.C. Units |
| 95 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 96 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 97 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 98 | Provision of new Reciprocating compressor (Carrier, Blue Star, Haier) (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 99 | Replacement of Reciprocating Compressor (Carrier, Blue Star, Haier) Less buy back value of old Compressor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 100 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 101 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 102 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 103 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 104 | Fan motor rewinding and fan bush replacement (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 105 | Replacement ofindoor Blower (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 106 | Replacement of fanoutdoor blade (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 107 | Replacement of digital remote board (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 108 | Repairing of digital remote board (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 109 | Replacement of air filter (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 110 | Replacement of single pole contactor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 111 | Replacement of indoor main PCB (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 112 | Replacement of Indoor sensor PCB (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 113 | Replacement of Outdoor PCB (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 114 | Replacement of expansion valve (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 115 | Replacement of outdoor sensors each (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 116 | Supply and fixing of MCB breaker 20 Amps for Cassette / Vertical type inverter A.C. Unit |
| 117 | Supply and fixing of MCB breaker 25 Amps for Cassette / Vertical type inverter A.C. Unit |
| 118 | Supply and fixing of MCB breaker 32 Amps for Cassette / Vertical type inverter A.C. Unit |
| 119 | Supply and fixing of metal glad plug and socket with MCB for Cassette / Vertical type inverter A.C. Unit |
| 120 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Cassette / Vertical type inverter A.C. Unit |
| 121 | Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 122 | Replacement of drain pipe for Cassette / Vertical type inverter A.C. Unit |
| 123 | Copper pipe with insulation(2.0 Ton) for Cassette / Vertical type inverter A.C. Unit |
| 124 | Thermal insulation with tape for Cassette / Vertical type inverter A.C. Unit |
| 125 | Complete rewiring kit for Cassette / Vertical type inverter A.C. Unit |
| 126 | Tinkering charge for outdoor unit for Cassette / Vertical type inverter A.C. Unit |
| 127 | Stabiliser repairing charge for Cassette / Vertical type inverter A.C. Unit |
| 128 | Supply of hand remote for Cassette / Vertical type inverter A.C. Unit |
| 129 | Replacement of indoor drain pump motor for Cassette / Vertical type inverter A.C. Unit |
| 130 | Repairing of indoor drain pump motor for Cassette / Vertical type inverter A.C. Unit |
| 131 | Swing Motors for Cassette / Vertical type inverter A.C. Unit |
| 132 | Dummy valve, ยผ, ยฝ, 5/8, 3/8 for Cassette / Vertical type inverter A.C. Unit |
| 133 | A/C Metal clad plug Top for Cassette / Vertical type inverter A.C. Unit |
| 134 | A/C Metal clad Socket for Cassette / Vertical type inverter A.C. Unit |
| 135 | 15A modular 3 pin Plug top for Cassette / Vertical type inverter A.C. Unit |
| 136 | 15A modular 3 pin socket for Cassette / Vertical type inverter A.C. Unit |
| 137 | Room Sensor for Cassette / Vertical type inverter A.C. Unit |
| 138 | Coil Sensor for Cassette / Vertical type inverter A.C. Unit |
| 139 | Replacement of outdoor Base plate for Cassette / Vertical type inverter A.C. Unit |
| 140 | A.C. unit pump down service for Cassette / Vertical type inverter A.C. Unit |
| 141 | Details of spares required for maintenance of split type non-inverter A.C. Units |
| 142 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.0 Ton) for Split type non-inverter A.C. Unit |
| 143 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit |
| 144 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit |
| 145 | Gas charging (410A Gas) and replacement of capillary tube & strainer (1.0 Ton) for Split type non-inverter A.C. Unit |
| 146 | Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit |
| 147 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit |
| 148 | Replacement of New Rotary compressor Less Buy back value of old compressor (1.0 Ton) for Split type non-inverter A.C. Unit |
| 149 | Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 150 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 151 | Provision of new Reciprocating compressor(Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) (1.0 Ton)for Split type non-inverter A.C. Unit |
| 152 | Provision of new Reciprocating compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) (1.5 Ton) for Split type non-inverter A.C. Unit |
| 153 | Provision of new Reciprocating compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi)for Split type non-inverter A.C. Unit |
| 154 | Replacement of Reciprocating Compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) Less buy back value of old Compressor (1.0 Ton) for Split type non-inverter A.C. Unit |
| 155 | Replacement of Reciprocating Compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) Less buy back value of old Compressor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 156 | Replacement of Reciprocating Compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) Less buy back value of old Compressor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 157 | Replacement of condensing coil Less buy back value of old condensing coil (1.0 Ton)for Split type non-inverter A.C. Unit |
| 158 | Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton)for Split type non-inverter A.C. Unit |
| 159 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type non-inverter A.C. Unit |
| 160 | Replacement of evaporating coil Less buy back value of old evaporating coil (1.0 Ton)for Split type non-inverter A.C. Unit |
| 161 | Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton)for Split type non-inverter A.C. Unit |
| 162 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type non-inverter A.C. Unit |
| 163 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.0 Ton)for Split type non-inverter A.C. Unit |
| 164 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit |
| 165 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type non-inverter A.C. Unit |
| 166 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.0 Ton) for Split type non-inverter A.C. Unit |
| 167 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit |
| 168 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype non-inverter A.C. Unit |
| 169 | Fan motor rewinding and fan bush replacement (1.0 Ton)for Split type non-inverter A.C. Unit |
| 170 | Fan motor rewinding and fan bush replacement (1.5 Ton)for Split type non-inverter A.C. Unit |
| 171 | Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type non-inverter A.C. Unit |
| 172 | Replacement ofindoor Blower (1.0 Ton) for Split type non-inverter A.C. Unit |
| 173 | Replacement ofindoor Blower (1.5 Ton) for Split type non-inverter A.C. Unit |
| 174 | Replacement ofindoor Blower (2.0 Ton) for Split type non-inverter A.C. Unit |
| 175 | Replacement of fanoutdoor blade (1.0 Ton)for Split type non-inverter A.C. Unit |
| 176 | Replacement of fanoutdoor blade (1.5 Ton)for Split type non-inverter A.C. Unit |
| 177 | Replacement of fanoutdoor blade (2.0 Ton)for Split type non-inverter A.C. Unit |
| 178 | Replacement of digital remote board (1.0 Ton)for Split type non-inverter A.C. Unit |
| 179 | Replacement of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit |
| 180 | Replacement of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit |
| 181 | Repairing of digital remote board (1.0 Ton)for Split type non-inverter A.C. Unit |
| 182 | Repairing of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit |
| 183 | Repairing of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit |
| 184 | Replacement of air filter (1.0 Ton)for Split type non-inverter A.C. Unit |
| 185 | Replacement of air filter (1.5 Ton)for Split type non-inverter A.C. Unit |
| 186 | Replacement of air filter (2.0 Ton) for Split type non-inverter A.C. Unit |
| 187 | Replacement of single pole contactor (1.0 Ton) for Split type non-inverter A.C. Unit |
| 188 | Replacement of single pole contactor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 189 | Replacement of single pole contactor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 190 | Replacement of fan capacitor 4-10 mfd for Split type non-inverter A.C. Unit |
| 191 | Replacement of running capacitor 36 mfd for Split type non-inverter A.C. Unit |
| 192 | Replacement of running capacitor 45 mfd for Split type non-inverter A.C. Unit |
| 193 | Replacement of running capacitor 50 mfd for Split type non-inverter A.C. Unit |
| 194 | Replacement of running capacitor 50+5 mfdfor Splittype non-inverter A.C. Unit |
| 195 | Supply and fixing of MCB breaker 20 Amps for Split type non-inverter A.C. Unit |
| 196 | Supply and fixing of MCB breaker 25 Amps for Split type non-inverter A.C. Unit |
| 197 | Supply and fixing of MCB breaker 32 Amps for Split type non-inverter A.C. Unit |
| 198 | Supply and fixing of metal glad plug and socket with MCB for Split type non-inverter A.C. Unit |
| 199 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type non-inverter A.C. Unit |
| 200 | Shifting of Split A.C. one location to another location including gas charge (1.0 Ton) for Split type non-inverter A.C. Unit |
| 201 | Shifting of Split A.C. one location to another location including gas charge (1.5 Ton) for Split type non-inverter A.C. Unit |
| 202 | Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type non-inverter A.C. Unit |
| 203 | Replacement of drain pipe for Split type non-inverter A.C. Unit |
| 204 | Copper pipe with insulation(1.0 Ton) for Split type non-inverter A.C. Unit |
| 205 | Copper pipe with insulation(1.5 Ton) for Split type non-inverter A.C. Unit |
| 206 | Copper pipe with insulation(2.0 Ton) for Split type non-inverter A.C. Unit |
| 207 | Thermal insulation with tape for Splittype non-inverter A.C. Unit |
| 208 | Complete rewiring kit for Split type non-inverter A.C. Unit |
| 209 | Tinkering charge for outdoor unit for Split type non-inverter A.C. Unit |
| 210 | Stabiliser repairing charge for Split type non-inverter A.C. Unit |
| 211 | Supply of hand remote for Split type non-inverter A.C. Unit |
| 212 | Swing Motors for Split type non-inverter A.C. Unit |
| 213 | Dummy valve, ยผ, ยฝ, 5/8, 3/8for Split type non-inverter A.C. Unit |
| 214 | A/C Metal clad plug Top for Split type non-inverter A.C. Unit |
| 215 | A/C Metal clad Socket for Split type non-inverter A.C. Unit |
| 216 | 15A modular 3 pin Plug top for Split type non-inverter A.C. Unit |
| 217 | 15A modular 3 pin socket for Split type non-inverter A.C. Unit |
| 218 | Room Sensor for Split type non-inverter A.C. Unit |
| 219 | Coil Sensor for Split type non-inverter A.C. Unit |
| 220 | Replacement of outdoor Base plate for Split type non-inverter A.C. Unit |
| 221 | A.C. unit pump down service for Split type non-inverter A.C. Unit |
| 222 | Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit |
| 223 | Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit |
| 224 | Details of spares required for maintenance of split type inverter A.C. Units |
| 225 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type inverter A.C. Unit |
| 226 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type inverter A.C. Unit |
| 227 | Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type inverter A.C. Unit |
| 228 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type inverter A.C. Unit |
| 229 | Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) for Split type inverter A.C. Unit |
| 230 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Split type inverter A.C. Unit |
| 231 | Provision of new Reciprocating compressor (Carrier, Blue Star) (1.5 Ton) for Split type inverter A.C. Unit |
| 232 | Provision of new Reciprocating compressor (Carrier, Blue Star) (2.0 Ton) for Split type inverter A.C. Unit |
| 233 | Replacement of Reciprocating Compressor (Carrier, Blue Star) Less buy back value of old Compressor (1.5 Ton) for Split type inverter A.C. Unit |
| 234 | Replacement of Reciprocating Compressor (Carrier, Blue Star) Less buy back value of old Compressor (2.0 Ton) for Split type inverter A.C. Unit |
| 235 | Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton)for Split type inverter A.C. Unit |
| 236 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type inverter A.C. Unit |
| 237 | Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton)for Split type inverter A.C. Unit |
| 238 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type inverter A.C. Unit |
| 239 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton)for Split type inverter A.C. Unit |
| 240 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type inverter A.C. Unit |
| 241 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton)for Split type inverter A.C. Unit |
| 242 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype inverter A.C. Unit |
| 243 | Fan motor rewinding and fan bush replacement (1.5 Ton)for Split type inverter A.C. Unit |
| 244 | Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type inverter A.C. Unit |
| 245 | Replacement ofindoor Blower (1.5 Ton) for Split type inverter A.C. Unit |
| 246 | Replacement ofindoor Blower (2.0 Ton) for Split type inverter A.C. Unit |
| 247 | Replacement of fanoutdoor blade (1.5 Ton)for Split type inverter A.C. Unit |
| 248 | Replacement of fanoutdoor blade (2.0 Ton)for Split type inverter A.C. Unit |
| 249 | Replacement of digital remote board (1.5 Ton)for Split type inverter A.C. Unit |
| 250 | Replacement of digital remote board (2.0 Ton)for Split type inverter A.C. Unit |
| 251 | Repairing of digital remote board (1.5 Ton)for Split type inverter A.C. Unit |
| 252 | Repairing of digital remote board (2.0 Ton)for Split type inverter A.C. Unit |
| 253 | Replacement of air filter (1.5 Ton)for Split type inverter A.C. Unit |
| 254 | Replacement of air filter (2.0 Ton) for Split type inverter A.C. Unit |
| 255 | Replacement of single pole contactor (1.5 Ton) for Split type inverter A.C. Unit |
| 256 | Replacement of single pole contactor (2.0 Ton) for Split type inverter A.C. Unit |
| 257 | Replacement of indoor main PCB (1.5 Ton) for splitl type inverter A.C. Unit |
| 258 | Replacement of indoor main PCB (2.0 Ton) for splitl type inverter A.C. Unit |
| 259 | Replacement of Indoor sensor PCB(1.5 Ton) for splitl type inverter A.C. Unit |
| 260 | Replacement of Indoor sensor PCB (2.0 Ton) for splitl type inverter A.C. Unit |
| 261 | Replacement of Outdoor PCB(1.5 Ton) for splitl type inverter A.C. Unit |
| 262 | Replacement of Outdoor PCB (2.0 Ton) for splitl type inverter A.C. Unit |
| 263 | Replacement of expansion valve (1.5 Ton) for splitl type inverter A.C. Unit |
| 264 | Replacement of expansion valve (2.0 Ton) for splitl type inverter A.C. Unit |
| 265 | Replacement of outdoor sensors each (1.5 Ton) for splitl type inverter A.C. Unit |
| 266 | Replacement of outdoor sensors each (2.0 Ton) for splitl type inverter A.C. Unit |
| 267 | Supply and fixing of MCB breaker 20 Amps for Split type inverter A.C. Unit |
| 268 | Supply and fixing of MCB breaker 25 Amps for Split type inverter A.C. Unit |
| 269 | Supply and fixing of MCB breaker 32 Amps for Split type inverter A.C. Unit |
| 270 | Supply and fixing of metal glad plug and socket with MCB for Split type inverter A.C. Unit |
| 271 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type inverter A.C. Unit |
| 272 | Shifting of Split A.C. one location to another location including gas charge (1.5 Ton) for Split type inverter A.C. Unit |
| 273 | Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type inverter A.C. Unit |
| 274 | Replacement of drain pipe for Split type inverter A.C. Unit |
| 275 | Copper pipe with insulation(1.5 Ton) for Split type inverter A.C. Unit |
| 276 | Copper pipe with insulation(2.0 Ton) for Split type inverter A.C. Unit |
| 277 | Thermal insulation with tape for Splittype inverter A.C. Unit |
| 278 | Complete rewiring kit for Split type inverter A.C. Unit |
| 279 | Tinkering charge for outdoor unit for Split type inverter A.C. Unit |
| 280 | Stabiliser repairing charge for Split type inverter A.C. Unit |
| 281 | Supply of hand remote for Split type inverter A.C. Unit |
| 282 | Swing Motors for Split type inverter A.C. Unit |
| 283 | Dummy valve, ยผ, ยฝ, 5/8, 3/8for Splittype inverter A.C. Unit |
| 284 | A/C Metal clad plug Top for Split type inverter A.C. Unit |
| 285 | A/C Metal clad Socket for Split type inverter A.C. Unit |
| 286 | 15A modular 3 pin Plug top for Split type inverter A.C. Unit |
| 287 | 15A modular 3 pin socket for Split type inverter A.C. Unit |
| 288 | Room Sensor for Split type inverter A.C. Unit |
| 289 | Coil Sensor for Split type inverter A.C. Unit |
| 290 | Replacement of outdoor Base plate for Split type inverter A.C. Unit |
| 291 | A.C. unit pump down service for Split type inverter A.C. Unit |
| 292 | Chief Secretariat, Puducherry |
| 293 | Monthly maintenance charges for Cassette / Vertical type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 294 | Monthly maintenance charges for split type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 295 | Total monthly maintaintence charges for 142 Nos. of A.C. Units |
| 296 | Total Annual maintaintence charges for 142 Nos. of A.C. Units |
| 297 | Details of spares required for maintenance of Cassette / Vertical type non-inverter A.C. Units |
| 298 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Cassette / Vertical type non-inverter A.C. unit |
| 299 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 300 | Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 301 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 302 | Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 303 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 304 | Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Lloyd) (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 305 | Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Lloyd) (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 306 | Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Lloyd) Less buy back value of old Compressor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 307 | Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Lloyd) Less buy back value of old Compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 308 | Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 309 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 310 | Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 311 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 312 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 313 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 314 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 315 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 316 | Fan motor rewinding and fan bush replacement (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 317 | Fan motor rewinding and fan bush replacement (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 318 | Replacement ofindoor Blower (1.5 Ton) for Cassette / Vertical type non-inverter A.C. unit |
| 319 | Replacement ofindoor Blower (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 320 | Replacement of fanoutdoor blade (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 321 | Replacement of fanoutdoor blade (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 322 | Replacement of digital remote board (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 323 | Replacement of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 324 | Repairing of digital remote board (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 325 | Repairing of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 326 | Replacement of air filter (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 327 | Replacement of air filter (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 328 | Replacement of single pole contactor (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 329 | Replacement of single pole contactor (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 330 | Replacement of fan capacitor 4-10 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 331 | Replacement of running capacitor 36 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 332 | Replacement of running capacitor 45 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 333 | Replacement of running capacitor 50 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 334 | Replacement of running capacitor 50+5 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 335 | Supply and fixing of MCB breaker 20 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 336 | Supply and fixing of MCB breaker 25 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 337 | Supply and fixing of MCB breaker 32 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 338 | Supply and fixing of metal glad plug and socket with MCB for Cassette / Vertical type non-inverter A.C. Unit |
| 339 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Cassette / Vertical type non-inverter A.C. Unit |
| 340 | Shifting of Cassette/Vertical A.C. one location to another location including gas charge(1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 341 | Shifting of Cassette/Vertical A.C. one location to another location including gas charge(2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 342 | Replacement of drain pipe for Cassette / Vertical type non-inverter A.C. Unit |
| 343 | Copper pipe with insulation(1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 344 | Copper pipe with insulation(2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 345 | Thermal insulation with tape for Cassette / Vertical type non-inverter A.C. Unit |
| 346 | Complete rewiring kit for Cassette / Vertical type non-inverter A.C. Unit |
| 347 | Tinkering charge for outdoor unit for Cassette / Vertical type non-inverter A.C. Unit |
| 348 | Stabiliser repairing charge for Cassette / Vertical type non-inverter A.C. Unit |
| 349 | Supply of hand remote for Cassette / Vertical type non-inverter A.C. Unit |
| 350 | Replacement of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit |
| 351 | Repairing of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit |
| 352 | Swing Motors for Cassette / Vertical type non-inverter A.C. Unit |
| 353 | Dummy valve, ยผ, ยฝ, 5/8, 3/8 for Cassette / Vertical type non-inverter A.C. Unit |
| 354 | A/C Metal clad plug Top for Cassette / Vertical type non-inverter A.C. Unit |
| 355 | A/C Metal clad Socket for Cassette / Vertical type non-inverter A.C. Unit |
| 356 | 15A modular 3 pin Plug top for Cassette / Vertical type non-inverter A.C. Unit |
| 357 | 15A modular 3 pin socket for Cassette / Vertical type non-inverter A.C. Unit |
| 358 | Room Sensor for Cassette / Vertical type non-inverter A.C. Unit |
| 359 | Coil Sensor for Cassette / Vertical type non-inverter A.C. Unit |
| 360 | Replacement of outdoor Base plate for Cassette / Vertical type non-inverter A.C. Unit |
| 361 | A.C. unit pump down service for Cassette / Vertical type non-inverter A.C. Unit |
| 362 | Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit |
| 363 | Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit |
| 364 | Details of spares required for maintenance of split type non-inverter A.C. Units |
| 365 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit |
| 366 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit |
| 367 | Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit |
| 368 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit |
| 369 | Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 370 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 371 | Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Panasonic, Mitshubhishi, Hitachi, Llyod, Haier, Voltas) (1.5 Ton) for Split type non-inverter A.C. Unit |
| 372 | Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Panasonic, Mitshubhishi, Hitachi, Llyod, Haier, Voltas) (2.0 Ton) for Split type non-inverter A.C. Unit |
| 373 | Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Panasonic, Mitshubhishi, Hitachi, Llyod, Haier, Voltas) Less buy back value of old Compressor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 374 | Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Panasonic, Mitshubhishi, Hitachi, Llyod, Haier, Voltas) Less buy back value of old Compressor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 375 | Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton)for Split type non-inverter A.C. Unit |
| 376 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type non-inverter A.C. Unit |
| 377 | Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton)for Split type non-inverter A.C. Unit |
| 378 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type non-inverter A.C. Unit |
| 379 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit |
| 380 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type non-inverter A.C. Unit |
| 381 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit |
| 382 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype non-inverter A.C. Unit |
| 383 | Fan motor rewinding and fan bush replacement (1.5 Ton)for Split type non-inverter A.C. Unit |
| 384 | Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type non-inverter A.C. Unit |
| 385 | Replacement ofindoor Blower (1.5 Ton) for Split type non-inverter A.C. Unit |
| 386 | Replacement ofindoor Blower (2.0 Ton) for Split type non-inverter A.C. Unit |
| 387 | Replacement of fanoutdoor blade (1.5 Ton)for Split type non-inverter A.C. Unit |
| 388 | Replacement of fanoutdoor blade (2.0 Ton)for Split type non-inverter A.C. Unit |
| 389 | Replacement of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit |
| 390 | Replacement of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit |
| 391 | Repairing of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit |
| 392 | Repairing of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit |
| 393 | Replacement of air filter (1.5 Ton)for Split type non-inverter A.C. Unit |
| 394 | Replacement of air filter (2.0 Ton) for Split type non-inverter A.C. Unit |
| 395 | Replacement of single pole contactor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 396 | Replacement of single pole contactor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 397 | Replacement of fan capacitor 4-10 mfd for Split type non-inverter A.C. Unit |
| 398 | Replacement of running capacitor 36 mfd for Split type non-inverter A.C. Unit |
| 399 | Replacement of running capacitor 45 mfd for Split type non-inverter A.C. Unit |
| 400 | Replacement of running capacitor 50 mfd for Split type non-inverter A.C. Unit |
| 401 | Replacement of running capacitor 50+5 mfdfor Splittype non-inverter A.C. Unit |
| 402 | Supply and fixing of MCB breaker 20 Amps for Split type non-inverter A.C. Unit |
| 403 | Supply and fixing of MCB breaker 25 Amps for Split type non-inverter A.C. Unit |
| 404 | Supply and fixing of MCB breaker 32 Amps for Split type non-inverter A.C. Unit |
| 405 | Supply and fixing of metal glad plug and socket with MCB for Split type non-inverter A.C. Unit |
| 406 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type non-inverter A.C. Unit |
| 407 | Shifting of Split A.C. one location to another location including gas charge (1.5 Ton) for Split type non-inverter A.C. Unit |
| 408 | Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type non-inverter A.C. Unit |
| 409 | Replacement of drain pipe for Split type non-inverter A.C. Unit |
| 410 | Copper pipe with insulation(1.5 Ton) for Split type non-inverter A.C. Unit |
| 411 | Copper pipe with insulation(2.0 Ton) for Split type non-inverter A.C. Unit |
| 412 | Thermal insulation with tape for Splittype non-inverter A.C. Unit |
| 413 | Complete rewiring kit for Split type non-inverter A.C. Unit |
| 414 | Tinkering charge for outdoor unit for Split type non-inverter A.C. Unit |
| 415 | Stabiliser repairing charge for Split type non-inverter A.C. Unit |
| 416 | Supply of hand remote for Split type non-inverter A.C. Unit |
| 417 | Swing Motors for Split type non-inverter A.C. Unit |
| 418 | Dummy valve, ยผ, ยฝ, 5/8, 3/8for Split type non-inverter A.C. Unit |
| 419 | A/C Metal clad plug Top for Split type non-inverter A.C. Unit |
| 420 | A/C Metal clad Socket for Split type non-inverter A.C. Unit |
| 421 | 15A modular 3 pin Plug top for Split type non-inverter A.C. Unit |
| 422 | 15A modular 3 pin socket for Split type non-inverter A.C. Unit |
| 423 | Room Sensor for Split type non-inverter A.C. Unit |
| 424 | Coil Sensor for Split type non-inverter A.C. Unit |
| 425 | Replacement of outdoor Base plate for Split type non-inverter A.C. Unit |
| 426 | A.C. unit pump down service for Split type non-inverter A.C. Unit |
| 427 | Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit |
| 428 | Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit |
| 429 | Main office, Electricity Department, Puducherry |
| 430 | Monthly maintenance charges for Cassette / Vertical type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 431 | Monthly maintenance charges for split type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 432 | Monthly maintenance charges for split type inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) |
| 433 | Total monthly maintaintence charges for 95 Nos. of A.C. Units |
| 434 | Total Annual maintaintence charges for 95 Nos. of A.C. Units |
| 435 | Details of spares required for maintenance of Cassette / Vertical type non-inverter A.C. Units |
| 436 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 437 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 438 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 439 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 440 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 441 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 442 | Provision of new Reciprocating compressor (Blue Star, Daikin, Carrier) (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 443 | Provision of new Reciprocating compressor (Blue Star, Daikin, Carrier) (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 444 | Replacement of Reciprocating Compressor (Blue Star, Daikin, Carrier)Less buy back value of old Compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 445 | Replacement of Reciprocating Compressor (Blue Star, Daikin, Carrier)Less buy back value of old Compressor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 446 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 447 | Replacement of condensing coil Less buy back value of old condensing coil (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 448 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 449 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 450 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 451 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 452 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 453 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 454 | Fan motor rewinding and fan bush replacement (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit |
| 455 | Fan motor rewinding and fan bush replacement (2.5 Ton) forCassette / Vertical type non-inverter A.C. unit |
| 456 | Replacement ofindoor Blower (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 457 | Replacement ofindoor Blower (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 458 | Replacement of fanoutdoor blade (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 459 | Replacement of fanoutdoor blade (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 460 | Replacement of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 461 | Replacement of digital remote board (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 462 | Repairing of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 463 | Repairing of digital remote board (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 464 | Replacement of air filter (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 465 | Replacement of air filter (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 466 | Replacement of single pole contactor (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 467 | Replacement of single pole contactor (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 468 | Replacement of fan capacitor 4-10 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 469 | Replacement of running capacitor 36 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 470 | Replacement of running capacitor 45 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 471 | Replacement of running capacitor 50 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 472 | Replacement of running capacitor 50+5 mfdfor Cassette / Vertical type non-inverter A.C. Unit |
| 473 | Supply and fixing of MCB breaker 20 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 474 | Supply and fixing of MCB breaker 25 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 475 | Supply and fixing of MCB breaker 32 Amps for Cassette / Vertical type non-inverter A.C. Unit |
| 476 | Supply and fixing of metal glad plug and socket with MCB for Cassette / Vertical type non-inverter A.C. Unit |
| 477 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Cassette / Vertical type non-inverter A.C. Unit |
| 478 | Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 479 | Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 480 | Replacement of drain pipe for Cassette / Vertical type non-inverter A.C. Unit |
| 481 | Copper pipe with insulation(2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 482 | Copper pipe with insulation (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit |
| 483 | Thermal insulation with tape for Cassette / Vertical type non-inverter A.C. Unit |
| 484 | Complete rewiring kit for Cassette / Vertical type non-inverter A.C. Unit |
| 485 | Tinkering charge for outdoor unit for Cassette / Vertical type non-inverter A.C. Unit |
| 486 | Stabiliser repairing charge for Cassette / Vertical type non-inverter A.C. Unit |
| 487 | Supply of hand remote for Cassette / Vertical type non-inverter A.C. Unit |
| 488 | Replacement of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit |
| 489 | Repairing of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit |
| 490 | Swing Motors for Cassette / Vertical type non-inverter A.C. Unit |
| 491 | Dummy valve, ยผ, ยฝ, 5/8, 3/8 for Cassette / Vertical type non-inverter A.C. Unit |
| 492 | A/C Metal clad plug Top for Cassette / Vertical type non-inverter A.C. Unit |
| 493 | A/C Metal clad Socket for Cassette / Vertical type non-inverter A.C. Unit |
| 494 | 15A modular 3 pin Plug top for Cassette / Vertical type non-inverter A.C. Unit |
| 495 | 15A modular 3 pin socket for Cassette / Vertical type non-inverter A.C. Unit |
| 496 | Room Sensor for Cassette / Vertical type non-inverter A.C. Unit |
| 497 | Coil Sensor for Cassette / Vertical type non-inverter A.C. Unit |
| 498 | Replacement of outdoor Base plate for Cassette / Vertical type non-inverter A.C. Unit |
| 499 | A.C. unit pump down service for Cassette / Vertical type non-inverter A.C. Unit |
| 500 | Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit |
| 501 | Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit |
| 502 | Details of spares required for maintenance of split type non-inverter A.C. Units |
| 503 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit |
| 504 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit |
| 505 | Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit |
| 506 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit |
| 507 | Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 508 | Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 509 | Provision of new Reciprocating compressor (Carrier, Blue Star, L.G. Daikin, Haier, Llyod, Panasonic, Mitshubhishi) (1.5 Ton) for Split type non-inverter A.C. Unit |
| 510 | Provision of new Reciprocating compressor (Carrier, Blue Star, L.G. Daikin, Haier, Llyod, Panasonic, Mitshubhishi)(2.0 Ton) for Split type non-inverter A.C. Unit |
| 511 | Replacement of Reciprocating Compressor (Carrier, Blue Star, L.G. Daikin, Haier, Llyod, Panasonic, Mitshubhishi) Less buy back value of old Compressor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 512 | Replacement of Reciprocating Compressor (Carrier, Blue Star, L.G. Daikin, Haier, Llyod, Panasonic, Mitshubhishi) Less buy back value of old Compressor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 513 | Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton)for Split type non-inverter A.C. Unit |
| 514 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type non-inverter A.C. Unit |
| 515 | Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton)for Split type non-inverter A.C. Unit |
| 516 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type non-inverter A.C. Unit |
| 517 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit |
| 518 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type non-inverter A.C. Unit |
| 519 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit |
| 520 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype non-inverter A.C. Unit |
| 521 | Fan motor rewinding and fan bush replacement (1.5 Ton)for Split type non-inverter A.C. Unit |
| 522 | Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type non-inverter A.C. Unit |
| 523 | Replacement ofindoor Blower (1.5 Ton) for Split type non-inverter A.C. Unit |
| 524 | Replacement ofindoor Blower (2.0 Ton) for Split type non-inverter A.C. Unit |
| 525 | Replacement of fanoutdoor blade (1.5 Ton)for Split type non-inverter A.C. Unit |
| 526 | Replacement of fanoutdoor blade (2.0 Ton)for Split type non-inverter A.C. Unit |
| 527 | Replacement of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit |
| 528 | Replacement of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit |
| 529 | Repairing of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit |
| 530 | Repairing of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit |
| 531 | Replacement of air filter (1.5 Ton)for Split type non-inverter A.C. Unit |
| 532 | Replacement of air filter (2.0 Ton) for Split type non-inverter A.C. Unit |
| 533 | Replacement of single pole contactor (1.5 Ton) for Split type non-inverter A.C. Unit |
| 534 | Replacement of single pole contactor (2.0 Ton) for Split type non-inverter A.C. Unit |
| 535 | Replacement of fan capacitor 4-10 mfd for Split type non-inverter A.C. Unit |
| 536 | Replacement of running capacitor 36 mfd for Split type non-inverter A.C. Unit |
| 537 | Replacement of running capacitor 45 mfd for Split type non-inverter A.C. Unit |
| 538 | Replacement of running capacitor 50 mfd for Split type non-inverter A.C. Unit |
| 539 | Replacement of running capacitor 50+5 mfdfor Splittype non-inverter A.C. Unit |
| 540 | Supply and fixing of MCB breaker 20 Amps for Split type non-inverter A.C. Unit |
| 541 | Supply and fixing of MCB breaker 25 Amps for Split type non-inverter A.C. Unit |
| 542 | Supply and fixing of MCB breaker 32 Amps for Split type non-inverter A.C. Unit |
| 543 | Supply and fixing of metal glad plug and socket with MCB for Split type non-inverter A.C. Unit |
| 544 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type non-inverter A.C. Unit |
| 545 | Shifting of Split A.C. one location to another location including gas charge (1.5 Ton) for Split type non-inverter A.C. Unit |
| 546 | Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type non-inverter A.C. Unit |
| 547 | Replacement of drain pipe for Split type non-inverter A.C. Unit |
| 548 | Copper pipe with insulation(1.5 Ton) for Split type non-inverter A.C. Unit |
| 549 | Copper pipe with insulation(2.0 Ton) for Split type non-inverter A.C. Unit |
| 550 | Thermal insulation with tape for Splittype non-inverter A.C. Unit |
| 551 | Complete rewiring kit for Split type non-inverter A.C. Unit |
| 552 | Tinkering charge for outdoor unit for Split type non-inverter A.C. Unit |
| 553 | Stabiliser repairing charge for Split type non-inverter A.C. Unit |
| 554 | Supply of hand remote for Split type non-inverter A.C. Unit |
| 555 | Swing Motors for Split type non-inverter A.C. Unit |
| 556 | Dummy valve, ยผ, ยฝ, 5/8, 3/8for Split type non-inverter A.C. Unit |
| 557 | A/C Metal clad plug Top for Split type non-inverter A.C. Unit |
| 558 | A/C Metal clad Socket for Split type non-inverter A.C. Unit |
| 559 | 15A modular 3 pin Plug top for Split type non-inverter A.C. Unit |
| 560 | 15A modular 3 pin socket for Split type non-inverter A.C. Unit |
| 561 | Room Sensor for Split type non-inverter A.C. Unit |
| 562 | Coil Sensor for Split type non-inverter A.C. Unit |
| 563 | Replacement of outdoor Base plate for Split type non-inverter A.C. Unit |
| 564 | A.C. unit pump down service for Split type non-inverter A.C. Unit |
| 565 | Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit |
| 566 | Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit |
| 567 | Details of spares required for maintenance of split type inverter A.C. Units |
| 568 | Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type inverter A.C. Unit |
| 569 | Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type inverter A.C. Unit |
| 570 | Replacement of New Rotary compressor (Carrier) Less Buy back value of old compressor (2.0 Ton) for Split type inverter A.C. Unit |
| 571 | Provision of new Reciprocating compressor (Carrier) (2.0 Ton) for Split type inverter A.C. Unit |
| 572 | Replacement of Reciprocating Compressor(Carrier) Less buy back value of old Compressor (2.0 Ton) for Split type inverter A.C. Unit |
| 573 | Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type inverter A.C. Unit |
| 574 | Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type inverter A.C. Unit |
| 575 | Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type inverter A.C. Unit |
| 576 | Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype inverter A.C. Unit |
| 577 | Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type inverter A.C. Unit |
| 578 | Replacement ofindoor Blower (2.0 Ton) for Split type inverter A.C. Unit |
| 579 | Replacement of fanoutdoor blade (2.0 Ton)for Split type inverter A.C. Unit |
| 580 | Replacement of digital remote board (2.0 Ton)for Split type inverter A.C. Unit |
| 581 | Repairing of digital remote board (2.0 Ton)for Split type inverter A.C. Unit |
| 582 | Replacement of air filter (2.0 Ton) for Split type inverter A.C. Unit |
| 583 | Replacement of single pole contactor (2.0 Ton) for Split type inverter A.C. Unit |
| 584 | Replacement of indoor main PCB (2.0 Ton) for splitl type inverter A.C. Unit |
| 585 | Replacement of Indoor sensor PCB (2.0 Ton) for splitl type inverter A.C. Unit |
| 586 | Replacement of Outdoor PCB (2.0 Ton) for splitl type inverter A.C. Unit |
| 587 | Replacement of expansion valve (2.0 Ton) for splitl type inverter A.C. Unit |
| 588 | Replacement of outdoor sensors each (2.0 Ton) for splitl type inverter A.C. Unit |
| 589 | Supply and fixing of MCB breaker 20 Amps for Split type inverter A.C. Unit |
| 590 | Supply and fixing of MCB breaker 25 Amps for Split type inverter A.C. Unit |
| 591 | Supply and fixing of MCB breaker 32 Amps for Split type inverter A.C. Unit |
| 592 | Supply and fixing of metal glad plug and socket with MCB for Split type inverter A.C. Unit |
| 593 | Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type inverter A.C. Unit |
| 594 | Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type inverter A.C. Unit |
| 595 | Replacement of drain pipe for Split type inverter A.C. Unit |
| 596 | Copper pipe with insulation(2.0 Ton) for Split type inverter A.C. Unit |
| 597 | Thermal insulation with tape for Splittype inverter A.C. Unit |
| 598 | Complete rewiring kit for Split type inverter A.C. Unit |
| 599 | Tinkering charge for outdoor unit for Split type inverter A.C. Unit |
| 600 | Stabiliser repairing charge for Split type inverter A.C. Unit |
| 601 | Supply of hand remote for Split type inverter A.C. Unit |
| 602 | Swing Motors for Split type inverter A.C. Unit |
| 603 | Dummy valve, ยผ, ยฝ, 5/8, 3/8for Splittype inverter A.C. Unit |
| 604 | A/C Metal clad plug Top for Split type inverter A.C. Unit |
| 605 | A/C Metal clad Socket for Split type inverter A.C. Unit |
| 606 | 15A modular 3 pin Plug top for Split type inverter A.C. Unit |
| 607 | 15A modular 3 pin socket for Split type inverter A.C. Unit |
| 608 | Room Sensor for Split type inverter A.C. Unit |
| 609 | Coil Sensor for Split type inverter A.C. Unit |
| 610 | Replacement of outdoor Base plate for Split type inverter A.C. Unit |
| 611 | A.C. unit pump down service for Split type inverter A.C. Unit |
Copyright © 2026 ยท All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail