| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-12-2025 |
| Sl. No. | Item Description |
| 1 | Material & Labour in repair for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC capping & casing or existing concealed conduit not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC surface type terminal box of suitable size with PVC cover complete all as specified as directed by Engineer in Charge. |
| 2 | All as per item No 1 above but point wiring for One light point controlled by two Nos 2-way switch complete all as specified as directed by Engineer in Charge. |
| 3 | All as per item No 1 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch complete all as specified as directed by Engineer in Charge. |
| 4 | All as per item No 1 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch complete all as specified as directed by Engineer in Charge. |
| 5 | All as per item No 1 above but One bell /Buzzer point controlled by one push button on the same board with other switch complete all as specified as directed by Engineer in Charge. |
| 6 | All as per item No 1 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified as directed by Engineer in Charge. |
| 7 | Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable, of size2.5 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC conduit/ casing capping not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified as directed by Engineer in Charge.Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 8 | Material & Labour ion repair for sub main wiring with 2 run single core multistranded copper conductor cable, of size4.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC conduit/ casing capping not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified as directed by Engineer in Charge.Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 9 | Material & Labour in repairfor sub main wiring with 2 run single core multistranded copper conductor cable, of size6.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC conduit/ casing capping not less than 32 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified as directed by Engineer in Charge.Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 10 | Material & Labour in repair for sub main wiring with 4 run single core multistranded copper conductor cable, of size10.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC conduit/ casing capping not less than 40 mm wide with all necessary fitting and including two run single core multistranded copper conductor cable, of size 10.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified as directed by Engineer in Charge. |
| 11 | M&L in repair Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete all as specified as directed by Engineer in Charge. |
| 12 | M&L in repair Switch Piano type, white polycarbonate body, single pole, two way 6 amp, 230 V, including connecting complete all as specified as directed by Engineer in Charge. |
| 13 | M & L in repair for Bell push, white polycarbonate body, 6 Amp, 230 V, including connecting complete all as specified as directed by Engineer in Charge. |
| 14 | M & L in repair for Switch socket combinationwhite polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete all as specified as directed by Engineer in Charge. |
| 15 | M & L in repair for Switch socket combinationwhite polycarbonate body, 6A / 16A- 230 V, Multipurpose, including connecting complete all as specified as directed by Engineer in Charge. |
| 16 | M & L in repair socket outlet 2 in 1 ,6/16 amps 5 in 1 flush type white polycarbonate body 230 V, Multipurpose, including connecting complete all as specified as directed by Engineer in Charge. |
| 17 | M & L in repair socket outlet 3 pin 6 amps amps flush type white polycarbonate body 230 V, Multipurpose, including connecting complete all as specified as directed by Engineer in Charge. |
| 18 | M&L in repair for casing capping of size 25-32 mm with its necessary accessories screw and bolt etc complete all as specified as directed by Engineer in Charge. |
| 19 | M&L in repair for pvc conduit of size 20-25 mm with its necessary accessories screw and bolt etc complete all as specified as directed by Engineer in Charge. |
| 20 | S&F in repair capacitor 2.5 Mfd suitable for ceiling fan complete along with taking down old one complete all as specified as directed by Engineer in Charge. |
| 21 | S&F in repair modular type switch, 230 volts, single pole one-way 6 Amps in 1 module & connecting complete all as specified as directed by Engineer in Charge. |
| 22 | Supply and fix in repair modular type bellpush, 230 volts, single pole one-way 6 Amps in 1 module including connection complete all as specified as directed by Engineer in Charge. |
| 23 | Supply and fix in repair modular type white socket 3 pin cum 2 pin, 6 Amps 230 volts in 2 modules complete all as specified as directed by Engineer in Charge. |
| 24 | Supply and fix in repair modular type white switch, 16 Amps 230 volts in 1 modules complete all as specified as directed by Engineer in Charge. |
| 25 | Supply and fix in repair modular type white fan regulator stepped type of 120 watt in 2 modules complete all as specified as directed by Engineer in Charge. |
| 26 | Fixing only dislogdged,hanging, surface plastic box,modular plate,tube lights,exhaust fans,distribution box,electric meter with driling new holes and screws and reconnecting it complete all as specified as directed by Engineer in Charge. |
| 27 | Supply and fix in repair surface plastic box of 1 module for mounting switch/socket inluding taking oiutold box and connecting all wires connection as in working condition complete all as specified as directed by Engineer in Charge. |
| 28 | Supply and fix in repair surface plastic box of 2 module for mounting switch/socket inluding taking oiutold box and connecting all wires connection as in working condition complete all as specified as directed by Engineer in Charge. |
| 29 | Supply and fix in repair surface plastic box of 4 module for mounting switch/socket inluding taking oiutold box and connecting all wires connection as in working condition complete all as specified as directed by Engineer in Charge. |
| 30 | Supply and fix in repair surface plastic box of 8 module for mounting switch/socket inluding taking outold box and connecting all wires connection as in working condition complete all as specified as directed by Engineer in Charge. |
| 31 | Supply and fix in repair 3 modular top plate with support plate of modular fitting including taking down old one complete all as specified as directed by Engineer in Charge. |
| 32 | Supply and fix in repair 8 module top plate with support plate of modular fitting including taking doen old one complete all as specified as directed by Engineer in Charge. |
| 33 | M&Lin repair for Ceiling rose, 3 terminal polycarbonate body 6 Amps, 250 volts AC, including connecting complete all as specified as directed by Engineer in Charge. |
| 34 | Supply and fix in repair stepped type electronic fan regulator flush type, 230 V, including connecting complete all as specified as directed by Engineer in Charge. |
| 35 | M & L in repair for Bell ding dong AC 230 Volts, single pole, including connecting complete all as specified as directed by Engineer in Charge. |
| 36 | S&F in repair Distribution boardmade out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type,240 V fixed flush to wall complete all as specified as directed by Engineer in Charge. |
| 37 | S&F in repair Distribution boardmade out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type,240 V fixed flush to wall complete all as specified as directed by Engineer in Charge. |
| 38 | S&F in repair Distribution boardmade out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type, fixed flush to wall complete all as specified as directed by Engineer in Charge. |
| 39 | S&F in repair Distribution boardmade out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way, vertical type with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, double door type 415 volts, fixed flush to wall complete all as specified as directed by Engineer in Charge. |
| 40 | Supply and fix in repair MCB’ssingle pole 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete all as specified as directed by Engineer in Charge. |
| 41 | Supply and fix in repair MCB’ssingle pole & neutral, 40-63 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete all as specified as directed by Engineer in Charge. |
| 42 | Supply and fix in repair MCB’ssingle pole & neutral,32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete all as specified as directed by Engineer in Charge. |
| 43 | Supply and fix in repair MCB’striple pole & neutral, 40-63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. |
| 44 | Supply and fix in repair MCB’striple pole & neutral 6-32 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. |
| 45 | Supply and fix in repair 2x36watt,240 V,50 Hz electronic choke suitable for false ceiling light fitting complete all as specified as directed by Engineer in Charge. |
| 46 | Supply and fix in repair 40watt,240 V,50 Hz electronic driver suitable for false ceiling light fitting complete all as specified as directed by Engineer in Charge. |
| 47 | Supply and fixin repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 amps, 240 V complete all as specified as directed by Engineer in Charge. |
| 48 | S&F in repair 18 watt Ballast , 220 V , 50 HZ suitable for 18 watt CFL light fitting complete all as specified as directed by Engineer in Charge. |
| 49 | S&F in repair 18 watts CFL, 2 or 4 pin type fixed to CFL light fittingscomplete all as specified as directed by Engineer in Charge. |
| 50 | S&F in repair 36 watts CFL, 2 or 4 pin type fixed to CFL light fittings complete all as specified as directed by Engineer in Charge. |
| 51 | S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired,fixed in position & connecting complete all as specified as directed by Engineer in Charge. |
| 52 | S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 8 to 10 watt, channel housing & diffuser of length 600 mm (approx) with all accessories, fixing arrangement internally pre-wired,fixed in position & connecting complete all as specified as directed by Engineer in Charge. |
| 53 | S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 5 watt, channel housing & diffuser of length 300 mm (approx) with all accessories, fixing arrangement internally pre-wired,fixed in position & connecting complete all as specified as directed by Engineer in Charge. |
| 54 | Supply and fixing in repair LED bulk head light fitting of 10 Watt capacity, Cool white with all connected accessories fixed in position complete all as specified as directed by Engineer in Charge. |
| 55 | S&Fin repair Recessed/ceiling mounted LED smart down light of 10-12 watt, 4000 K including all fitting, fixturecomplete all as specified as directed by Engineer in Charge. |
| 56 | S&F in repairRecessed/ceiling mounted LED smart down light of 5-6 watt, 4000 K including all fitting, fixturecomplete all as specified as directed by Engineer in Charge. |
| 57 | S&F in repairRecessed mounted LED round panel light of 15-16 watt, 6500 K ofincluding all fitting, fixturecomplete all as specified as directed by Engineer in Charge.. |
| 58 | Supply and fix driver in repairEnergy efficient recessed mounted LED luminaries 36 watt suitable for 600 x 600 mm grid ceiling along withflat diffuser along with constant current electronic driver including taking down and refixing complete all as specified as directed by Engineer in Charge. |
| 59 | Supply and fixin repairEnergy efficient recessed mounted LED luminaries 36 watt suitable for 600 x 600 mm grid ceiling along withflat diffuser along with constant current electronic driver complete all as specified as directed by Engineer in Charge. |
| 60 | Taking down carefully ceiling fan / wall mounted fan/exhaust fan by disconnecting electric connection for repairing such as rewinding, replacement of defective spare part, over haulingetc as required and re-fixing in the same position after carry out the repairs works, and connecting complete all as specified as directed by Engineer in Charge.Note:-(i) Repairing such as rewinding, replacement of defective spare part, connecting wire etc will be measured & paid separately as supply & fix in repair . (ii) Overhauling and painting will be measured and paid separately. (iii)Replacement of nut, bolt ,washer, split pin and rubber seal for the down rod of ceiling fan if found defective will be measured and paid separately as supply only. |
| 61 | M & L for rewinding of ceiling fan 1200 mm sweep of any make, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enameled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as specified as directed by Engineer in Charge.Replacement of bearing and capacitor paid seprately as supply only. |
| 62 | M & L for rewinding of wall mounted fan 400-600 mm sweep of any make by dismantling the fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enameled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as specified as directed by Engineer in Charge.Replacement of bearing and capacitor paid seprately as supply only. |
| 63 | All as item No 62 above but exhaust fan 300 mmsweep.Replacement of bearing and capacitor, arms set paid seprately as supply only complete all as specified as directed by Engineer in Charge. |
| 64 | All as item No 62 above but exhaust fan 450 mmsweep.Replacement of bearing and capacitor ,arms setpaid seprately as supply only complete all as specified as directed by Engineer in Charge. |
| 65 | Supply& fix in repair louvers shutter aluminum body size 450mmx 450mm size including taking down old louver complete all as specified as directed by Engineer in Charge. |
| 66 | Supply& fix in repair only MS clamp with MS nuts,bolts, rubber bush, quarter pin complete for the down rod of ceiling fan complete all as specified as directed by Engineer in Charge. |
| 67 | Supply and fix in repair ball bearing suitable for ceilingfan 1200 mm sweep of any type and make complete all as specified as directed by Engineer in Charge. |
| 68 | Supply and fix in repair Capacitor of 4/3.15 mfd capacity for exhaust fan on any sweep including removing old one complete all as specified as directed by Engineer in Charge. |
| 69 | supply and fix in replacementfor plastic body exhaust fan of capacity 200-225 mm exhaust fan complete all as specified as directed by Engineer in Charge. |
| 70 | supply and fix in replacementfor plastic body exhaust fan of capacity 300 mm exhaust fan complete all as specified as directed by Engineer in Charge. |
| 71 | supply and fix in repair ball bearing for exhaust fan of capacity 300 mm exhaust fan complete all as specified as directed by Engineer in Charge. |
| 72 | supply and fix in repair ball bearing for exhaust fan of capacity 450mm exhaust fan complete all as specified as directed by Engineer in Charge. |
| 73 | supply and fix in repair suicide fan downrod of 15\"\" including taking down and refixing the fan complete all as specified as directed by Engineer in Charge. |
| 74 | Comprehensive / Preventive maintenance / servicing of Window/Split AC up to 2.0 ton capacity of any make, maintenance carried out by cleaning of cooling and condenser coil of indoor and outdoor units with descaling solution, checking of refrigerant pressure and charging of refrigerant gas including testing / checking the serviceability of spares such as starting capacitor, running capacitor, fan motor, blower motor relays, thermostat, & wiring etc and servicing complete of indoor and outdoor units complete all as specified as directed by Engineer in Charge.Note:-(i)Spares such as starting capacitor, running capacitor, fan motor, blower motor relays, thermostat, & wiring etc if found defective will be measured & paid separately as supply & fix in repairs. |
| 75 | (ii) Charging of gas if required will be measured and paid separately as supply & topping of gas complete all as specified as directed by Engineer in Charge.(iii)Replacement of compressor wherever required will be measured and paid separately. |
| 76 | Comprehensive / Preventive maintenance / servicing of water cooler capacity 80/20 ,120/150 of any make, maintenance carried out by cleaning of water cooler and cleaning capiilary tube cleaning blower fan and motor , providing new hinges,locking arrangements ,taps included in comprehensive maintenence cost and checking of refrigerant pressure and charging of refrigerant gas including testing / checking the serviceability of spares such as starting capacitor, running capacitor, fan motor, blower motor relays, thermostat, & wiring etc and servicing complete of indoor and outdoor units complete all as specified as directed by Engineer in Charge.Note:Spares such as starting capacitor, running capacitor, fan motor, blower motor relays, thermostat, & wiring ,compressor,etc if found defective will be measured & paid separately as supply & fix in repairs. |
| 77 | Material & labour for recharging of R-32/22/407/410/134 gas to Window/ Split type air conditioner of capacity 1.5 / 2.0 TR after flushing the complete system, vacuum testingand the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete all as specified as directed by Engineer in Charge. |
| 78 | Material & labour for recharging of R-32/22/407/410gas to refrigerator of capacity300 / 310 ltrs after flushing the complete system, vacuum testingand the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete all as specified as directed by Engineer in Charge. |
| 79 | Material & labour for recharging of R-32/22/407/410gas to water cooler ofstorage capacity 80/120 ltrs & cooling capacity 40 ltrs after flushing the complete system, vacuum testing up to 24 hours and the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete all as specified as directed by Engineer in Charge. |
| 80 | Dismantling blowerof water cooler/deep and supply and fixing new fan blower of indoor unitin repair along with fan of existing make and size and refixing in position, connecting and testing on loadcomplete all as specified as directed by Engineer in Charge. |
| 81 | Dismantling blowerof split AC 1.5 / 2 TR and supply and fixing new fan blower of indoor unitin repair along with fan of existing make and size and refixing in position, connecting and testing on loadcomplete all as specified as directed by Engineer in Charge. |
| 82 | Dismantling blower fan motor of split AC 1.5 / 2 TR and supply and fixing new fan motor of indoor unitin repair along with fan of existing make and size and refixing in position, connecting and testing on load complete all as specified as directed by Engineer in Charge. |
| 83 | Dismantling blower fan motor of split AC 1.5 / 2 TR and supply and fixing new fan motor of outdoor unitin repair along with fan of existing make and size and refixing in position, connecting and testing on loadcomplete all as specified as directed by Engineer in Charge. |
| 84 | Dismantling blower fan motor of 80/40 and 120/150 ltrs water cooler and supply and fixing new fan motor in repair along with fan of existing make and size and refixing in position, connecting and testing on load complete all as specified as directed by Engineer in Charge. |
| 85 | S&F in repair Over load Protector suitable for window type AC of capacity 1.5 Ton complete all as specified as directed by Engineer in Charge. |
| 86 | S&F in repair starting capacitor80 to 100 MFDsuitable for window type AC / Split AC 1.5 TRcomplete all as specified as directed by Engineer in Charge. Make Keil, Keltron,Epcon |
| 87 | S&F in repair running capacitor 36-45 MFD suitable for window type / Split AC 1.5 / 2.0 Ton complete all as specified as directed by Engineer in Charge. |
| 88 | S&F in repair starting relay suitable for water coolerof any capacity complete all as specified as directed by Engineer in Charge. |
| 89 | S&F in repair thermostat switchsuitable forrefrigerator of capacity165 / 300 Ltrs complete all as specified as directed by Engineer in Charge. |
| 90 | S&F in repair contactor relay suitable for split typeair conditioner of capacity 1.5 /2 TR capacity complete all as specified as directed by Engineer in Charge. |
| 91 | M&L for replacement non invertor PCB suitable indoor/ outdoor for split type AC 1.5/2 ton capacity ofalong with necessary electrical connections including spare parts transformer,diode,triode,condensor etc. complete all as specified as directed by Engineer in Charge. Make LG / Carrier / Voltas / Blue Star |
| 92 | S&F in repairsof PCB for indoor unit suitable for inverter type split type AC 1.5/2 ton capacity ofalong with necessary electrical connections including spare parts etc complete all as specified as directed by Engineer in Charge. Make LG / Carrier / Voltas / Blue Star |
| 93 | S&F in repairsof PCB for outdoor unit suitable for inverter type split type AC 1.5/2 ton capacity of along with necessary electrical connections including spare parts etc. complete all as specified as directed by Engineer in Charge. Make LG / Carrier / Voltas / Blue Star |
| 94 | S&F in repair cooling effect transmitting motorsuitable for refrigerator 310 Ltrs capacity complete all as specified as directed by Engineer in Charge. |
| 95 | M&L in Repairs to internal remote assembly corded / cordless universal of split type AC 1.5 / 2.0 ton capacity complete all as specified as directed by Engineer in Charge. |
| 96 | Supply and fix in repair PVC flexible pipe of 15 mm dia suitable for Split AC out let of water drain pipe as per sample complete all as specified as directed by Engineer in Charge. |
| 97 | Supply and fix outdoor unit condensing coil (Aluminum material) whole assembly suitable for 1.5/2 TR split AC along with standard accessories, fitting, fixtureincluding fixed in position as per standard practice and dismantling / taking down complete all as specified as directed by Engineer in Charge. |
| 98 | Supply and fix outdoor unit condensing coil (copper material) whole assembly suitable for 1.5/2 TR split AC along with standard accessories, fitting, fixtureincluding fixed in position as per standard practice and dismantling / taking down complete all as specified as directed by Engineer in Charge. |
| 99 | Supply and fix in repairs brass service valve of size 3/8\" suitable for split ACs of any capacity complete all as specified as directed by Engineer in Charge. |
| 100 | Supply and fix in repairs brass service valve of size 5/8\" suitable for split ACs of any capacity complete all as specified as directed by Engineer in Charge. |
| 101 | Supply and fix in repair insulation on copper pipe of split AC of size 1/4 inch internal diameter and thickness 6mm complete all as specified as directed by Engineer in Charge. |
| 102 | Supply and fix in repair insulation on copper pipe of split AC of size 1/2 inch internal diameter and thickness 6mm complete all as specified as directed by Engineer in Charge. |
| 103 | Supply and fix in repair cupromet copper tube ASTM B68 of size 1/4 inch x 0.48 mm complete all as specified as directed by Engineer in Charge. |
| 104 | Supply and fix in repair cupromet copper tube ASTM B68 of size 1/2 inch x 0.48 mm complete all as specified as directed by Engineer in Charge. |
| 105 | Supply and fix in repair PVC insulated and PVC sheathed 3 core with multi stranded flexible copper cable of size 2.5 sqmm including connecting complete for desert cooler complete all as specified as directed by Engineer in Charge. |
| 106 | Supply and fix in repair PVC float valve with complete set of rod and ball of 15 mm size for water cooler of any capacity complete all as specified as directed by Engineer in Charge. |
| 107 | Supply and fix in repairs stainless steel drain water tray of water coolers of any capacity of existing size by suitable size of screws nut and bolts complete all as specified as directed by Engineer in Charge. |
| 108 | Supply and fix in repair thermostate any type (i.e; Cup thread or triangular) of capacity 2 KW,220/230 Volts ISI marked,incluiding Its thermostate and relay fixed to electric geyser of any capacity complete all as specified as directed by Engineer in Charge.Note: sample of heating element is provided by office of Engr-in-charge. |
| 109 | Supply and fix in repair Heating element any type (i.e; Cup thread or triangular) of capacity 2 KW,220/230 Volts ISI marked,incluiding Its thermostate and relay fixed to electric geyser of any capacity complete all as specified as directed by Engineer in Charge.Note: sample of heating element is provided by office of Engr-in-charge. |
| 110 | Supply and fix in repair Hot water connection (2 nos) brass chromium plated, with brass chromium plated hexagonal adaptor, 450 mm long complete with rubber washer,ISI marked complete all as specified as directed by Engineer in Charge. |
| 111 | Supply and fix in repair Plug top 3 pin 15 Amps, polycarbonate body, ISI marked & connecting complete all as specified as directed by Engineer in Charge. |
| 112 | M&L for replacement of5 Kva Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with out put voltage stabilized at 230V with accuracy of±2.5% complete all as specified as directed by Engineer in Charge. |
| 113 | S&F in repair AC 3 pin metal clad top use for AC power supply box complete all as specified as directed by Engineer in Charge. |
| 114 | M&L for taking out unserviceable compressor sealed unitof 40/80 water cooler , single phase 230 Volts, and replacing the same with new compressor sealed unit fixing & connecting the same including vacumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete all as specified as directed by Engineer in Charge. Note: Unserviceable old retrieved compressor shall be replace with the same authorized dealer / company manufacture. Make - Carrier / LG / Blue Star / Voltas / Shriram |
| 115 | M&L for taking out unserviceable compressor sealed unitof 1.5 ton capacity from the split type AC , single phase 230 Volts, and replacing the same with new compressor sealed unit fixing & connecting the same including vacumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete all as specified as directed by Engineer in Charge. Note: Unserviceable old retrieved compressor shall be replace with the same authorized dealer / company manufacture. Make - Carrier / LG / Blue Star / Voltas / Shriram |
| 116 | M&L for taking out unserviceable compressor sealed unitof 2 ton capacity from the split type AC , single phase 230 Volts, and replacing the same with new compressor sealed unit fixing & connecting the same including vacumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete all as specified as directed by Engineer in Charge. Make - Carrier / LG / Blue Star / Voltas / Shriram Note: Unserviceable old retrieved compressor shall be replace with the same authorized dealer / company manufacture. |
| 117 | Supply and fix in replacement heavy duty Air conditioner outdoor Ac stand for 0.8 to 2 ton (mounting bracket) 24 inch including taking out old bracket with AC and and refixing the AC with new bracket complete all as specified as directed by Engineer in Charge. |
| 118 | Supply and fix in repairhoneycomb padnumbers for air suction side for Symphony Hicool i 31 Litre Airevaporative cooler of cooling capacityof 50 Sqft complete all as specified as directed by Engineer in Charge. |
| 119 | Supply and fix in repair desert cooler submerssible pumpof capacity 8 watt,220-240 V,50 Hz and maximium lift of 1 meter complete all as specified as directed by Engineer in Charge.Make:- crompton greaves/khaitan/usha/Symphony |
| 120 | Supply and fix in repair centifuge type fan blade along with its two bearing suitable for Symphony Hicool31 Litre Airevaporative cooler of cooling capacity 50 sqft complete all as specified as directed by Engineer in Charge. Sample is Kept in office of AGE(B&R) Samana. |
| 121 | Supply and fix in repair fan motor of capcity 185 watt ,230 V, 50 Hz for Symphony Hicool31 Litre Airevaporative cooler complete all as specified as directed by Engineer in Charge. Make:- crompton greaves/khetan/coolhome |
| 122 | Supply and fix in repair PCB board ofSymphony Hicool31 Litre Airevaporative cooler complete all as specified as directed by Engineer in Charge. |
| 123 | M&L for taking out and rewinding of Exhaust fan motor of capacity 500 watt ,230 V,50 HZ for industrial desert cooler of sweep 1400 sqft with copper wire, after rewinding fix it in its position complete in running condition with connection complete all as specified as directed by Engineer in Charge. |
| 124 | Supply and fix in repair 5 amps 240 V, three pin plug top complete all as specified as directed by Engineer in Charge. |
| 125 | Comprehensive / Preventive maintenance / servicing of PackageAC of 11 ton capacity of any make, maintenance carried out by cleaning of cooling and condenser coil of indoor and outdoor units with descaling solution, checking of refrigerant pressure and charging of refrigerant gas including testing / checking the serviceability of spares such as starting capacitor, running capacitor, fan motor, blower motor relays, thermostat, & wiring etc and servicing complete of indoor and outdoor units complete all as specified as directed by Engineer in Charge.Note:-(i)Spares such as starting capacitor, running capacitor, fan motor, blower motor relays, thermostat, & wiring etc if found defective will be measured & paid separately as supply & fix in repairs. |
| 126 | (ii) Charging of gas if required will be measured and paid separately as supply & topping of gas.(iii)Replacement of compressor wherever required will be measured and paid separately.(iv) consumable like wiring, nuts, terminal blocks connecting wires lugs are included in comprehensive maintenence |
| 127 | S&Fin repair compressor over load protection relay current rating 16-22 Amps rated voltage 415V, 50HZ including connecting complete all as specified as directed by Engineer in Charge.Make:- SIEMENS / L&T / ABB/ BCH / C&S / Legrand |
| 128 | Supply and fix in repair hermetic filter drier DCL 305 for Air cooled package AC of 11 ton capcity complete all as specified as directed by Engineer in Charge.Make:- Danfoss/Emerson or equivalent make as approved by GE Part no :- DCL 305 023Z0014 danfoss. |
| 129 | Supply and fix in repair suction line accumulator for package AC of 11 ton capcity , Model ACCM-5330-9S complete all as specified as directed by Engineer in Charge.Make:- Danfoss/Emerson or equivalent make as approved by GE |
| 130 | Material & labour for leakage checkAir cooled package air conditioner of capacity 11 TR after flushing the complete system, vacuum testing and filling nitrogenand the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete all as specified as directed by Engineer in Charge.Note: Gas for recharging will be paid seperately |
| 131 | Supply and fix in repair fan blade suitable for outdoor unit of Air cooled package AC of 11 ton capcity complete all as specified as directed by Engineer in Charge. |
| 132 | Supply and fix in repair condensing unit fan motor suitable for outdoor unit of Air cooled package AC of 11 ton capcity complete all as specified as directed by Engineer in Charge. |
| 133 | Supply and fix in repairbrass expansion valvesuitable for Air cooled chiller AC of 40 ton capcity complete all as specified as directed by Engineer in Charge.Make:- Danfoss/Emerson or equivalent make as approved by GE |
| 134 | Supply and fix in repairbrass expansion valvesuitable for Air cooled package AC of 11 ton capcity complete all as specified as directed by Engineer in Charge.Make:- Danfoss/Emerson equivalent make as approved by GE |
| 135 | M&L in repair for AHU motor of capacity 10HP, with removing and installation after rewinding in its position with its belt connection with damper blower complete all as specified as directed by Engineer in Charge. |
| 136 | M&L in repair for motor rewinding of indoor unit 11 TR package AC air blow duct three phase induction motor of capacity 2.2 HP,230 V,50 Hz with removing and installation after rewinding in its position with its belt connection with damper blower complete all as specified as directed by Engineer in Charge. |
| 137 | supply and installation and testing indoor unit aluminum metal cross flow blower of indoor unit 11 TR package AC and aligning it with three phase induction motorwith taking out old one asspecified as directed by Engineer in Charge. |
| 138 | S&F in repair pedestral bearning P205 for package AC discharge air duct blower complete all as specified as directed by Engineer in Charge. |
| 139 | M&L for descaling cleaningof complete makeup tankchilled water pipe, copper condenser/evaporator pipe ,cleaning air filter of central air cooledtype AC plants of Make- Bluestar, model KAC2-048AP2capacitiy 40TR X4 by circulating suitable descaling compound / solution into the tube/pipe with pump, and running the pump continuously till all the scale from tub/pipe are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc.and pressurised cleaning of40 TR chiller with waterafter applying cleain solution also making the alignmen of 4 chiller pumps correctly complete all as specified as directed by Engineer in Charge.Note :- (i) The Contractor shall descalinated each AC Plant twice during contract period . (ii) Eachdescaling shall be counted as one job for the purpose of payment.(iii) The time interval between both descaling will be intimated by Engineer-in-charge as per requirement. |
| 140 | Note :- contrator will carried out descaling work two time during contract period and shall be measured two times, the time interval between both descaling will intimated by Engineer -in-charge as per requirement . |
| 141 | M&L for taking out Chilled water pumps 7 HPopening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings,shaft and base plate, reassembling, refixing and alingnment properly in same position & connectingwith coupling shaft including testing and commissioning complete all as specified as directed by Engineer in Charge. |
| 142 | Supply and fix in repair of coupling for 7 HP pump and motor complete all as specified as directed by Engineer in Charge. |
| 143 | Supply and fix in repair of 100 mm dial type Pressure Gauge with appropriate range & SS valvesand SS tubing complete all as specified as directed by Engineer in Charge. |
| 144 | Supply and fix in repair of set of individual confirm 150 mm dial type Temp Gauge with appropriate range & SS valvesand SS tubing complete all as specified as directed by Engineer in Charge. |
| 145 | Comprehensive maintenance / basicservicing of chilled water 4 way cassette unit /FCU up to 4.0 ton capacity of any make, maintenance carried out bycleaning offilter and condenser coil of indoor units with pressure spray of water cleaning of strainer and testing the serviceability of wiring (cost of change of wire and cables included) of units complete all as specified as directed by Engineer in Charge.Note:-(i)Spares such as s, fan blade, blower motor relays, thermostat, & wiring etc if found defective will be measured & paid separately as supply & fix in repairs. |
| 146 | S&Fin repairs ofPCB suitable for four way chilled water type cassate units/FCU unit AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etccomplete all as specified and as directed. |
| 147 | Supply and installation in repair of insulation with using 12 mm thick open cell Nitrile Rubber for pipe duct / plenum, complete all as specified as directed by Engineer in Charge.Make: Armaflex/ Aeroflex/ Durkee |
| 148 | Supply and fix in repair of 25mm Auto air purge valve/ for chilled water pipingt complete all as specified as directed by Engineer in Charge. |
| 149 | Providing and fixing replacing in position of approved make AFT valve complete with Aluminum control wiring at chiller outlet complete all as specified as directed by Engineer in Charge. |
| 150 | S&F in repairs of coil sensorfor four way chilled water type cassatte units/FCU unit AC 1.5/2 ton capacity along with necessary electrical connections including spare parts etc, complete all as specified as directed by Engineer in Charge. Make LG / Carrier / Voltas / Blue Star |
| 151 | S&Fin repairs oftemperature sensorfor four way chilled water type cassatte units/FCU unit AC 1.5/2 ton capacityalong with necessary electrical connections including spare parts etc complete all as specified as directed by Engineer in Charge.Make LG / Carrier / Voltas / Blue Star |
| 152 | S&Frepairing ofdrain pump for four way chilled water type cassatte units/FCU unit AC 1.5/2 ton capacity along with necessary electrical connections including spare parts etc complete all as specified as directed by Engineer in Charge.Make LG / Carrier / Voltas / Blue Star |
| 153 | S&Frepairing offloat valve sensor suitable for four way chilled water type cassette units/FCU unit AC any capacityalong with necessary electrical connections including spare parts etccomplete all as specified as directed by Engineer in Charge.Make LG / Carrier / Voltas / Blue Star |
| 154 | S&Frepairing of2/3 way actuater valve suitable for four way chilled water type cassette units/FCU unit AC any capacityalong with necessary electrical connections including spare parts etc complete all as specified as directed by Engineer in Charge.Make LG / Carrier / Voltas / Blue Star |
| 155 | S&Freplacement ofblower fan blade with bearing ofchilled water four way cassette unit AC 1.5/2/3/4 ton capacity of Make Carrier along with necessary electrical connections including spare parts etc complete all as specified as directed by Engineer in Charge. |
| 156 | S&Freplacement offan motor ofchilled water four way cassette unit AC 1.5/2/3/4 ton capacity of Make Carrier along with necessary electrical connections including spare parts etc complete all as specified as directed by Engineer in Charge. |
| 157 | Supply & fix in repairspre filter10 micron of size 610x610x50mm AHU chiller unit complete all as specified as directed by Engineer in Charge.Make: THERMADYNE or equivalent make approved by GE |
| 158 | Supply & fix in repairsin pre filter 10 micron of size 395x483x25mm AHUchiller unit complete all as specified as directed by Engineer in Charge.Make: THERMADYNE or equivalent make approved by GE. |
| 159 | Supply and fix in repair contactor 3 pole ,240 V,32 amps for Package AC panel complete all as specified as directed by Engineer in Charge..Make:-NC1 3201 |
| 160 | Supply and fix in repair contactor 3 pole ,240 V,18 amps for Package AC panel complete all as specified as directed by Engineer in Charge..Make:- NC1 1801 |
| 161 | Supply and fix in repair LP/HP cutout for compressor of 40 TR blue star pakage unit complete all as specified as directed by Engineer in Charge. Make dafnoss or equivalent |
| 162 | Supply and fix in repair LP/HPswitch cutout for compressor ofr 11 TR blue star pakage unit complete all as specified as directed by Engineer in Charge. Make dafnoss or equivalent |
| 163 | Supply and toping up refrigerant gas R-407 C to the central / package AC plant of any capacity system complete all as specified as directed by Engineer in Charge. |
| 164 | Material & labourchecking leakge in Air cooled package air conditioner of capacity 11 TR after flushing the complete system, vacuum testing, Nitrogen fillingand the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete all as specified as directed by Engineer in Charge. |
| 165 | Material & labour for checkingleakage central air cooled chillercapacity 40 TR after flushing the complete system, vacuum testing, Nitrogen fillingand the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete all as specified as directed by Engineer in Charge. |
| 166 | S&Fin repair 4 pole power contactor 12A, 415 V, coil voltage 230 V including connecting complete all as specified as directed by Engineer in Charge. |
| 167 | S&Fin repair 4 pole power contactor 9A, 415 V, coil voltage 230 V including connecting complete all as specified as directed by Engineer in Charge. |
| 168 | S&Fin repair 4 pole power contactor 60 A, 415 V, coil voltage 230 V including connecting complete all as specified as directed by Engineer in Charge. |
| 169 | Supply and fix in repair \"V\" belts of size A-32 of 11 TR pakage AC plant motorof AC planttype complete all as specified as directed by Engineer in Charge. |
| 170 | Supply and fix in repair \"V\" belts of size B-72/75 of AHU motorof AC planttype complete all as specified as directed by Engineer in Charge. |
| 171 | Supply and fix in repair \"V\" belts of size B-100/112 of AHU motorof AC plant any type complete all as specified as directed by Engineer in Charge. |
| 172 | S&Fin repair temperature controller display with cable bluestar pakage AC 11 TRincluding connecting complete all as specified as directed by Engineer in Charge. |
| 173 | S&Fin repair compressor thermal over load protection type 12 Arated voltage :- 415V, 50HZ including connecting complete all as specified as directed by Engineer in Charge. |
| 174 | S&Fin repair compressor thermal over load protection type 60 Arated voltage :- 415V, 50HZ including connecting complete all as specified as directed by Engineer in Charge. |
| 175 | Supply and fixing inrepair Oil/HP/LPpressure sensor Probe suitable for scroll Chiller unit of 40 TR central AC plant complete all as specified as directed by Engineer in Charge.Make:- bluestar or equivalent make approved by the GE. |