| 1 | M&L of septic tank of size 16Cum, PMF Tank size 5.8Cum, FFT Tank size 1.9 Cum, TWT tank size 1.9 Cum including sufficient pump for filter and arboriculture having capacity of sewage generation 6Cum / day including excavation and foundation of tank as designed by OEM and as directed by Engineer in Charge for 100 User capacity.OEM of tank : Sujal Eco Tech Pvt Ltd or Techno Commercially equivalent or as approved by Garrison Engineer |
| 2 | M&L of RCC NP3 150 mm diameter Pipes laid on 150 mm thick bedPCC Cradle PCC 1:4:8 with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functionalfor depth 0.70m – 1.65 m complete all as specified and directed.. |
| 3 | M&L of RCC NP3 150 mm diameter Pipes laid on 150 mm thick bed PCC Cradle PCC 1:4:8 with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functionalfor depth 1.65 – 2.30 m complete all as specified and directed.. |
| 4 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above GL) complete all as specified and directed. |
| 5 | M&L for 75mm thick PCC 1:4:8type D2 using 40mm graded stone aggregate as in sub base etc. complete all as specified and directed. |
| 6 | M&L for Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick , set , jointed and pointed in neat cement slurry over and including15 mm thick screed bed or bedding layers in CM 1:6 for laying floor finishes in floors , path / hard standing etc with grey cement andpigment (Coloured Tiles) complete all as specified and directed |
| 7 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 8 | M&L for Glossy finished pre-polished coloured machine pressed precast concrete interlocking paver block any shpe and size confirming to IS 15658-2006 of 60 mm thickness , M-35 grade with grey cement and pigments complete all as specified and directed. |
| 9 | M & L for Rendering 15 mm thick on brick or concretesurfaces in cement mortar (1:4) finished even & fair without using extra cement work complete all as specified and directed. |
| 10 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar complete all as specified and directed. |
| 11 | M&L Brick work with sub class \"B\", old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 12 | M&L for Pavement quality concrete(PQC) of minimum 28 days field Flexural strength of 45Kg/ Sqcm or 4.5Mpa, aggregate gradation as per Table 3 of IRC 15 2017, coarse aggregate of clean , hard strong, dense non-porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed stone sand or combination of both using minimum 360 kg/cum of cement with non -circular virgin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1 .39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum meltingtemperature as 240°C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minimum 7.50 m width , including curing and tining by Texturing cum Curing Machine complete all as specified and directed. Requ ired surface texturing to be done as specified in Clause -, rr,10 1 14 and Tabl~ 9 of IRC\" 15-2017. |
| 13 | M&L 150mm thick PCC 1:4:8type D2- using 40mm graded stone aggregate as in sub base etc. complete all as specified and directed. |
| 14 | M&L 150cm thick (compacted thickness) WBM with coarse aggregates of grading 1 (90 to 40mm size),spread, rolled and consolidated to gradient and camber required complete all as specified and directed. |
| 15 | M&L Quarried rubble stone or broken nullah boulders, in large pieces for soling/sub base of road, etc complete all as specified and directed. |
| 16 | Dismantling water tanks exc 250 but not exc 500 Litres capacity complete all as specified and directed. |
| 17 | Dismantling water tanksexc 500 but not exc 1000 Litres capacity.1000 Litres capacity complete all as specified and directed. |
| 18 | S&F rotational moulded water storage tank 500 Ltr capacity double layer (cylindrical/vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 19 | S&F rotational moulded water storage tank 1000 Ltr capacity double layer (cylindrical/vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 20 | S&F 25 mm ball brass valves,high pressure,with polythene float and flynutcomplete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 21 | S&F in repairs 25 mm ball brass valves,high pressure,with polythene float and flynutcomplete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 22 | S&F in repairs 40 mm ball brass valves,high pressure,with polythene float and flynutcomplete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 23 | Taking up or down steel /UPVC water tubing and connections,25 mm bore complete all as specified and directed. |
| 24 | Taking up or down steel /UPVC water tubing and connections,40 mm bore complete all as specified and directed. |
| 25 | Refixing/ fixing only old steel / UPVC tubing and connections 20 mm bore in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed. |
| 26 | Refixing/ fixing only old steel / UPVC tubing and connections 25-32 mm bore in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed. |
| 27 | S&F 25 mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. |
| 28 | S&F 32 mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. |
| 29 | S&F 25 mm Brass elbow for PVC/ iron pipe complete all as specified and directed. |
| 30 | S&F 32 mm Brass elbow for PVC/ iron pipe complete all as specified and directed. |
| 31 | S&F 25 mm Brass Tee for PVC/ iron pipe complete all as specified and directed. |
| 32 | S&F 32 mm Brass Tee for PVC/ iron pipe complete all as specified and directed. |
| 33 | S&F 25 mm Brass union for PVC/ iron pipe ccomplete all as specified and directed. |
| 34 | S&F 32 mm Brass union for PVC/ iron pipe complete all as specified and directed. |
| 35 | S&F in repairs Gun-metal, globe or gate valves 20 mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 36 | S&F in repairs Gun-metal, globe or gate valves 25mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 37 | S&F of 110 mm (4\") Down take Pipes fixing done with Pipe Supporting Clamping System with Bracket Set with Pipe Support Channel + U Bolt Rubber Sleeve mounted system running vertically with wall distance 75 mm (3\"):Pipe Supporting Clamping made of: Pipe Bracket for 110 mm (4\") PVC Pipe with pipe suppon channel having Wall Distance 75 mm (3\") made of Low Carbon Hot roll Gauge Corrected Oil Pickled & Orawn (HROP D) Steel (IS 1079); with ribs and notch are Hot Dip Galvanzied + Zn AI Flake coated having Salt Spray Test (Test method - ASTM B-117-20t9) result 2000 hrs.2. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn AI rlake coated with noise absorbingtransparent ribbed silicon rubber sleeve mounted; with Hex Flange Nut BSW 5/16 x 18 8 x T3 with Serration set as per DIN 6923 - Zn AI Flake coated. Hotdip Galvanising: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 DD used as per MTC confirms to IN10204.Material Quantity for one unit : 1. Rain Water Bracket Set with pipe support channel for 110 mm (4“) PVC Pipe; Wall distance 75 mm (3\") - 1 Nos. ; 2. U Bolt Rubber Sleeve mounted for 110 mm (4\") PVC Pipe Dia. - 1 No.; and 3.Fixing Nail of thickness 6.5 mm and length 63 mm (2 1/2\") - 2 nos. |
| 38 | S&F of 75 mm (3\") Down take Pipes fixing done with Pipe Supporting Clamping System with Bracket Set with Pipe Support Channel + U Bolt Rubber Sleeve mounted system running vertically with wall distance 75 mm (3\"):Pipe Supporting Clamping made of:Pipe Bracket for 75 mm (3\") PVC Pipe with pipe suppon channel having Wall Distance 75 mm (3\") made of Low Carbon Hot roll Gauge Corrected Oil Pickled & Orawn (HROP D) Steel (IS 1079); with ribs and notch are Hot Dip Galvanzied + Zn AI Flake coated having Salt Spray Test (Test method - ASTM B-117-20t9) result 2000 hrs.2. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn AI rlake coated with noise absorbingtransparent ribbed silicon rubber sleeve mounted; with Hex Flange Nut BSW 5/16 x 18 8 x T3 with Serration set as per DIN 6923 - Zn AI Flake coated.Hotdip Galvanising: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 DD used as per MTC confirms to IN10204 Material Quantity for one unit : 1. Rain Water Bracket Set with pipe support channel for 75 mm (3“) PVC Pipe; Wall distance 75 mm (3\") - 1 Nos. ; 2. U Bolt Rubber Sleeve mounted for 110 mm (4\") PVC Pipe Dia. - 1 No.; and 3.Fixing Nail of thickness 6.5 mm and length 63 mm (2 1/2\") - 2 nos. |
| 39 | S&F in repairs 75 mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints, laid in floors/ trenchescomplete all as specified and directed. |
| 40 | S&F in repairs 110 mm bore PVC (SWR) pipes single socketed inany length withrubber ring joints fixed to walls complete all as specified and directed. |
| 41 | S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed. |
| 42 | S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed. |
| 43 | S&F PVC (SWR) vent cowl any radius 75mm dia complete all as specified and directed. |
| 44 | S&F PVC (SWR) vent cowl any radius 110mm dia complete all as specified and directed. |
| 45 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal 75mm dia complete all as specified and directed. |
| 46 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal 110mm dia complete all as specified and directed. |
| 47 | S&F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement75 mm bore dia of outlet of pipe complete all as specified and directed. |
| 48 | S&F in repairs PVC (SWR) gully trap 125/110mm setting and jointing with solvent cementand making good of disturbing gound with PCC 1:2:4 complete all as specified and directed. |
| 49 | S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 50 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of steel surfaces complete all as specified and directed. |
| 51 | Brick work with sub class \"B\", old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 52 | Supply only Liquid water proofing compound. |