| 1 | Manual Rescue and Operation Rescue of Two lifts from 0600 to 1400 and 1400 hrs to 2200 hrs in two shifts operated by one operatorper shift for both the lifts (one operator for two lifts per shift shall be employed) on all days including holidays and during all type of weather/climatic conditions, providing rescue to the trapped person, maintaining the lifts and connected equipments and accessories including lift room in clean and tidy condition during the operation period and also Manning & Operation of Lifts in case of failure of commercial supplyby running of DG Set installed within the vicinity meant for lift supply complete all as specified and directed. Location:- 08 passenger lift and 13 passanger lift, both the Lifts are serving Ground+ 7 Upper Floors and installed at Vidhut Cheetah, B Camp, P-56. |
| 2 | Manual Rescue and Operation Rescue of Four lifts from 0600 to 1400 and 1400 hrs to 2200 hrs in two shifts operated by one operatorper shift for both the lifts (one operator for four lifts per shift shall be employed) on all days including holidays and during all type of weather/climatic conditions, providing rescue to the trapped person, maintaining the lifts and connected equipments and accessories including lift room in clean and tidy condition during the operation period and also Manning & Operation of Lifts in case of failure of commercial supplyby running of DG Set installed within the vicinity meant for lift supply complete all as specified and directed. Location:- 10 passengerlift and Goods Lift (Capacity 2000Kg), both of the lifts are serving Ground + 06 Upper Floors and installed at Godavari Building (NOFRA) P-31 & 08 passenger lift single lift is serving Ground + 05 Upper Floors and installed at Kaveri Bldg(NOFRA), P-09 & 08 passenger lift single lift is serving Ground + 06 Upper Floors and installed at Single Offr Accn Bldg(NOFRA), P-76 |
| 3 | Manual Rescue and Operation Rescue of Three lifts from 0900 to 1700 hrs in one shift operated by one operatorper shift for both the lifts (one operator for three lifts per shift shall be employed) on all days including holidays and during all type of weather/climatic conditions, providing rescue to the trapped person, maintaining the lifts and connected equipments and accessories including lift room in clean and tidy condition during the operation period and also Manning & Operation of Lifts in case of failure of commercial supplyby running of DG Set installed within the vicinity meant for lift supply complete all as specified and directed.Location:- 08 passenger lift and 08 passanger lift, both the Lifts are serving Ground + 5 Upper Floors and installed at Release Block (Tanaji), P-79 & 08 passanger lift single Lift is serving Ground + 5 Upper Floors and installed at DSC Single Living Accomodation (Tanaji), P-7 |
| 4 | Manual Rescue and Operation Rescue of Four lifts from 0900 to 1700 hrs in One shift operated by one operator per shift for both the lifts (one operator for four lifts per shift shall be employed)on all days including holidays and during all type of weather/climatic conditions, providing rescue to the trapped person, maintaining the lifts and connected equipments and accessories including lift room in clean and tidy condition during the operation period and also Manning & Operation of Lifts in case of failure of commercial supply by running of DG Set installed within the vicinity meant for lift supply complete all as specified and directed.Location:- Goods Lift (Capacity 2000Kg) and Goods Lift (Capacity 3000Kg) both of the lifts are serving Ground + 02 Upper Floors and installed at NSD Store (SPDC), CMT Complex, P-77 & 8 passanger lift and 08 passanger lift both Lifts are serving Ground+ 5 Upper Floors and installed at GE Office, (SPDC)Notes for item No.01 to 04:-(a)Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves and other instruments etc, as required for maintenance, manning and operation of Lift shall be arranged by the contractorfrom his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account.(b) Installation shall be manned including Saturdays, Sunday & Holiday.(c)Proper log sheets to be maintained.(e)Carry out weekly maintenance of Lift panels installed in Lift Room and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f)Carry out checking of nuts bolts, replace when required, applying oil and greasing.(g)The contractor shall be responsible to keep the Lift cabin and installation neat and clean on every day.(h)All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue.(j) If the operator are found absent from duty, penal recovery shall be made per shift per head are as follows :-(i)Operator- @ Rs 2000 per operation shift per head. |
| 5 | Comprehensive maintenance (Routine , preventive , breakdown) as per attached format (Daily, weekly, fortnightly, monthly, qtrly, half yearly, yearly maintenance) and keeping the lift and its connected equipments in servicable condition round the clock(on all days including holidays) and during all type of weather/climatic conditions for the undermentioned lift of any type (geared or gearless, Auto or manual operated, with or without VVVF drive system, with or without ARD system etc) and also maintainingthe necessary documents complete all as specified and directed.Location:- 08 passenger lift and 13 passanger lift, both the Lifts are serving Ground+ 7 Upper Floors and installed at Vidhut Cheetah, B Camp, P-56 |
| 6 | Comprehensive maintenance (Routine , preventive , breakdown) as per attached format (Daily, weekly, fortnightly, monthly, qtrly, half yearly, yearly maintenance) and keeping the lift and its connected equipments in servicable condition round the clock(on all days including holidays) and during all type of weather/climatic conditions for the undermentioned lift of any type (geared or gearless, Auto or manual operated, with or without VVVF drive system, with or without ARD system etc) and also maintainingthe necessary documents complete all as specified and directed. Location:- 10 passengerlift and Goods Lift (Capacity 2000Kg), both of the lifts are serving Ground + 06 Upper Floors and installed at Godavari Building (NOFRA) P-31 |
| 7 | Comprehensive maintenance (Routine , preventive , breakdown) as per attached format (Daily, weekly, fortnightly, monthly, qtrly, half yearly, yearly maintenance) and keeping the lift and its connected equipments in servicable condition round the clock(on all days including holidays) and during all type of weather/climatic conditions for the undermentioned lift of any type (geared or gearless, Auto or manual operated, with or without VVVF drive system, with or without ARD system etc) and also maintainingthe necessary documents complete all as specified and directed. Location:- 08 passenger lift single lift is serving Ground + 05 Upper Floors and installed at Kaveri Bldg(NOFRA), P-09 |
| 8 | Comprehensive maintenance (Routine , preventive , breakdown) as per attached format (Daily, weekly, fortnightly, monthly, qtrly, half yearly, yearly maintenance) and keeping the lift and its connected equipments in servicable condition round the clock(on all days including holidays) and during all type of weather/climatic conditions for the undermentioned lift of any type (geared or gearless, Auto or manual operated, with or without VVVF drive system, with or without ARD system etc) and also maintainingthe necessary documents complete all as specified and directed. Location:- 08 passenger lift single lift is serving Ground + 06 Upper Floors and installed at Songle Offr Accn Bldg(NOFRA), P-76 |
| 9 | Comprehensive maintenance (Routine , preventive , breakdown) as per attached format (Daily, weekly, fortnightly, monthly, qtrly, half yearly, yearly maintenance) and keeping the lift and its connected equipments in servicable condition round the clock(on all days including holidays) and during all type of weather/climatic conditions for the undermentioned lift of any type (geared or gearless, Auto or manual operated, with or without VVVF drive system, with or without ARD system etc) and also maintainingthe necessary documents complete all as specified and directed. Location:- 08 passenger lift and 08 passanger lift, both the Lifts are serving Ground+ 5 Upper Floors and installed at Release Block (Tanaji), P-79 |
| 10 | Comprehensive maintenance (Routine , preventive , breakdown) as per attached format (Daily, weekly, fortnightly, monthly, qtrly, half yearly, yearly maintenance) and keeping the lift and its connected equipments in servicable condition round the clock(on all days including holidays) and during all type of weather/climatic conditions for the undermentioned lift of any type (geared or gearless, Auto or manual operated, with or without VVVF drive system, with or without ARD system etc) and also maintainingthe necessary documents complete all as specified and directed. Location:- 08 passanger lift single Lift is serving Ground+ 5 Upper Floors and installed at Dsc Single Living Accomodation (Tanaji), P-7Note:For BOQ item No. 05 to 10 only:-Comprehensive maintenance of lifts shall be done by the contractor through respective OEM as mentioned in on Schedule \"A\" Notes, Note No. 18 on Serial page No. 17 of tender documents and MoU shall be submitted to GE office within 30 days of acceptance of tender failing which, contract shall be cancelled without any notice to the contractor.Please also refer Note No.18 (a), (b), (c), (d) on Serial page No. 17 of tender documents. |
| 11 | Comprehensive maintenance (Routine , preventive , breakdown) as per attached format (Daily, weekly, fortnightly, monthly, qtrly, half yearly, yearly maintenance) and keeping the lift and its connected equipments in servicable condition round the clock(on all days including holidays) and during all type of weather/climatic conditions for the undermentioned lift of any type (geared or gearless, Auto or manual operated, with or without VVVF drive system, with or without ARD system etc) and also maintainingthe necessary documents complete all as specified and directed. Location:- Goods Lift (Capacity 2000Kg) and Goods Lift (Capacity 3000Kg) both of the lifts are serving Ground + 02 Upper Floors and installed at NSD Store (SPDC), CMT Complex, P-77 |
| 12 | Dismantling and taking out u/s old control paneland control wiring and S & Fnew control panel in hinged MS powder coated cabinet, with control wiring comprising with multiple micro controlled programmed chip based, controlled by pulse modulation, complete with all safeties such as thermal over load protection , over current protection, auto phase reverse link to each other in net work, andcompitable to 18.5KW / 25.0 HP capacity VVVF driveincludingproper connection with proper lugs, terminalconnectors screws and motor connectionwith galvanished sheet trucking 24 SWG including wiring of main motor with suitable size of standard copper cable etc lifts complete all as specified and as directedby Engr-in-Charge. |
| 13 | Taking down unserviceable main pulley with complete set Supply & fixing new main pully with complete set complete all as specified & directed by Engr-in-Charge. |
| 14 | Taking down unserviceable Overspeed governor assembly complete set Supply & fixing new Overspeed governor assembly with complete set complete all as specified & directed by Engr-in-Charge. |
| 15 | Disconnecting and taking out defective shaft wiring andproviding new shaft wiring in hoist way upto lower limit switch with PVC insulatedcopper conductor cable size 1.0sqmm 1100volts grade with ISI marked and0.75sqmm single corefor earthing drawing through in andincluding galvanised sheet metal (24 SWG) trucking upto ground floor inhoist way for control of all floor hall push button assembly limit switch,Firemen switch etc. Complete all; as specified as directed by Engr-in-Charge. |
| 16 | Dismantling & Taking out defective unserviceable main drive (any type) from existing control panel and supply and fixing new variable voltage, variable frequency drive (VVVF) of make Yasakawa/Fuji Japan/Monarch upto 18.5.0 KW suitable for EXISTING LIFT and including making necessary electric connection, complete all as specified and directed. |
| 17 | Dismantling & Taking out defective unserviceable main drive (any type) from existing control panel and supply and fixing new variable voltage, variable frequency drive (VVVF) of make Yasakawa/Fuji Japan/Monarch upto 11.0 KW suitable for EXISTING LIFT and including making necessary electric connection, complete all as specified and directed. |
| 18 | Dismantling and Taking out unserviceable old landing push button box alongwith illuminated call button with control wiring & in lieu supplying and fixing new landing push button box alongwith illuminated call button and LED display indicator with CPI card on stainless steel face plate with control wiring, complete all as specified and directed. |
| 19 | Disconnecting and Taking out existing unserviceable COP assembly and supply and fixing new car operating panel (COP) assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, complete all as specified and directed. |
| 20 | Taking out old unservicable travelling cable from hoist way and supply and fixingnew travelling cable PVC insulated, 12 core, flat / round type withstrandedcopper conductor, 1100 volts grade of size 0.75 sqmm, conforming to relavant IS with and including crimping with lugs of appropriate thimbles, suspended type, freelymoveable with car cabin up & down betweenground & upper floors includingnecessary proper connectionetc withmid way junction andother connectionsrequiredin circuit, complete all as specifedand directedMake : Finolex / Polycab/ Incab/ Macrotherm. |
| 21 | Dismantling and taking out defective automatic door drive unit and Supply & Fix New door drive unit with 1.0 HP motor, VVVF Drive car topdrive to match with existing system as specified and directed by Engineer-In-Charge |
| 22 | Taking out existing old defective senser and in lieu proving new senser with INFRA RED safety edge with power unit for full hight of car door to safeguard passenger entering and leaving the lift complete all as specified and directed, Weco or equivalent makes as approved by GE. |
| 23 | Taking out existing Emergency Alarm System and S&F new hooter complete all as specified and directed by the Engr-in-Charge. |
| 24 | Taking down existing unserviceble ARD batteries from machine room and in lieu S & F new sealed maintenance free (SMF) batteries of 12 volts, 18 AH (Make : Exide/ Amron), making necessary connections with and including copper lead to connect brass terminals of batteries etc, complete all as specified and directed by the Engr-in-Charge. |
| 25 | Taking down existing underviceable ARD from machine room and S&F new Automatic Rescue Device (ARD) including relays, PCB cards/dioders card and ,complete all as specified and directed |
| 26 | Taking down existing unserviceable LED light from ceiling of cabin and Supply & Fix new LED light 3 Watt Complete with all accessories including wiring complete all as specified and directed. |
| 27 | Disconnecting and taking out unserviceable Main steel wire rope after disconnecting from car cabin, supply and fixing in steel wire rope 8 mm diaungalvanised08/19 construction in and including necessary connection with machine room and shaft pit complete with clamp nuts bolts and washers complete all as specified and as directed by the Engr-in-charge. |
| 28 | Disconnecting andtaking out unserviceable Main steel wire rope after disconnecting from car cabin supply and fixing main steel wire rope 13 mm dia ungalvanised08/19 construction in and includingnecessary connection with machine room and shaft pit complete with clamp nut bolt and washers complete all as specified and directed by Engr-in-charge. |
| 29 | Taking out existing unserviceable cabin fan and providing new cabin fan, non-oscilating type, axial flow, single speed, 300mm sweep, 240 volt, with grill, (Make : EMCO/VBM/CINI), complete all as specified and directed. |