Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-12-2025 |
| 2 | 10-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-12-2025 |
| Sl. No. | Item Description |
| 1 | M&L for demolition of brick work manually/ by mechanical means built in any cement mortar including stacking of serviceable material including disposal of material/malba outside MoD land from 5KM to 20KM lead at municipal dumping ground complete as specified and directed. |
| 2 | M&L for brick work straight or curved on plan exc 6m mean radius in cement mortar (1:4) with Sub class ‘B’ brick including manhole raising, footpath, etc complete all as specified and directed. |
| 3 | Taking down cement plaster/grit plaster any description on brick/concrete surfaces etc including raking out joints hacking for key, scrubing down with water etc including disposal of material/malba outside Mod land from 5KM upto 20KM lead at municipal dumping ground complete allas specified and directed. |
| 4 | M&Lfor 15mm thick renderingin cement mortar 1:6 on fair faces of new or old brick works or concrete work finished even & smooth without using extra cement complete all as specified and as directed. (i) Rate of plaster upto 10 M from ground level included. (ii) Shuttering/Jhoola/Struts etc required for plaster shall be arranged by the contractor.(iii) No other extra payment shall be made in this item. |
| 5 | M&L for 15mm thickrendering in cement mortar 1:4 on other than fair faces of new or old brick work or concrete work, finished even & smooth without using extra cement for height upto 10mfrom ground level including necessary shuttering/struts/Jhoola etc arrangement complete allas specified and directed. |
| 6 | M&L for 5 mm thick cement plaster of mix 1:3 (1 cement : 3 fine sand) on ceiling surface, new or old brick works or concrete work finished even & smoothwithout using extra cementcomplete allas specified and directed. |
| 7 | M&L for distempering with oil bound distemper(two or more coats)of approved brand and manufacture to give an even shade on new work over and including a coat ofwhite cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete allas specified and directed. |
| 8 | M&L for finishing and painting walls with Acrylic Smooth weather proof exterior emulsion paint of required shade on new work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete allas specified and directed. |
| 9 | M&L for white washing with lime to give an even shade on New work (three or more coats)complete as specified and directed. |
| 10 | M&Lfor complete removal dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches and Distempering two or more coats with 1st quality acrylic distemper having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade, over and including a coat of birla white wall care putyof average thickness 1 mm and applying additional coats wherever required, to achieve smooth surface complete allas specified and directed. |
| 11 | M&Lfor complete removal of old emulsion painrt, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches and painting walls with 100% Premium acrylic emulsion paint of exterior grade with two or more coats applied @ 1.43 litre/ 10 sqm of required shade including over and including priming coat of exterior primer complete allas specified and directed. |
| 12 | M&Lfor Painting One or more coats with synthetic enamel paint on OLD workon wood/steel surfaces of any description and size of approved brand and manufacture of required colour to give an even shade complete allas specified and directed. |
| 13 | M&L for cutting openings, through brick walls in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core etc. to store and rubbish not exc. 50m. |
| 14 | M&L for demolishing cement concrete,Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 15 | Providing and laying design mix cement concrete of M-30 grade prepared in automatic batching plant (RMC plant) including transportation to site in transit mixer,as in roads/Pavements/ taxi tracks and like, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, including providing of dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,finishing with required texture by brooming, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/expansion joints, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge Note:- 1. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge.2.Item of joint fillers/ sealants to be paid separately3. use and waste of side form for laying pavement concrete/hard-standing in bays between joints & contraction expansion joint/or between the two contraction joints for thickness of pavement upto and including 25 cm shall deem to beincluded in the unit quoted rate. 4. Design mix cement concrete shall be prepared in automatic batching plant (RMC plant) including transportation to site in transit mixer and contractor shall quote his rates keeping this aspect in mind. |
| 16 | M&L Forming 25 mm width expansion joint in concrete slab for full depth of POC. Early entry saw and subsequent cutting by using diamond bit cutter of appropriate size. straight and smooth edges. Join cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil , vegetation and other debris. The join then filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified thereafter application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 30 mm dia, over filler board and filled with polyurethane based sealant complying with BS- 5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of+/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints andremoving the masking tape after filling of sealant as per the method specified by the manufacture complete as specified and directed. |
| 17 | Forming dummy/contraction joint with an initial saw cut of 3 mm soon after the concrete has set, upto a depth of 1 J3rd to 1 /41h the thickness of the slab widening the first saw cut to 6 mm and 24 mm deep by using diamond bit cutter of appropriate size straight and smooth edges Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegetation and other debris. Application of two coats of primer with thin brush by forward and backwardmovement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell, medium density, crossed linked polyethylene foam backup rod of 8 mm dia application of bond breaker tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant complying with BS-5212 , BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) OF +/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed. |
| 18 | M&L for forming & Cutting of construction joints 25 mm deep and 10 mm wide by early entry saw cut using diamond bicutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application o compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil , vegetation and othe debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 12 mm dia, application of bond breake tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN- 141875- 2003 with minimum movement accommodation factor (MAF) of +I- 30% having minimum 10 year performance guarantee, applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed |
| 19 | M&L for dismentling of floor tiles / hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish of the premises out side MOD land complete all as specified and directed. |
| 20 | M&L for Providing and fixing Ist quality ceramic glazed coloured wall tiles of 300mm x 450mm x 7mm thick conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours and shades, of any size as approved by Engineer-in-Charge, in vertical surfaces including skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 21 | M&L for dismantling stone slab flooring and paver block laid in cement mortar including stacking of serviceable materialincluding disposal of material/malba outside MoD land from 5KM to 20KM lead at municipal dumping ground complete as per direction of Engineer - in - charge. |
| 22 | M&L for Kota stone slab flooring 18-20 mm thick laidover 20 mm (average) thick bedding layer in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete complete all as specified and directed. |
| 23 | M&L for providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources)type D2 using 40 mm graded mechanically crushed stone aggregate as in filling in mass concretein foundation and sub base of floor complete all as specified excluding the cost of centering and shuttering - All work up to plinth level complete all as specified and directed. |
| 24 | M&L for PVC sheets 2mm thick, laminated plain colour and design as in flooring approved by Engr-in-charge, laid with approved rubber based adhesive in floors complete all as specified and directed. |
| 25 | Dismantling and taking down doors, windows and clerestory windows (steel or wood)shutter of area 3 sq. metres and below including chowkhats/frames, architrave, holdfasts etc. including disposal of material/malba outside MoD land from 5KM to 20KM lead at municipal dumping ground complete as per direction of Engineer - in - charge. |
| 26 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coatingnot less than 50 micron thick) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 100 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction of Engineer-in-charge. |
| 27 | M&L for providing and fixing aluminium work Powder coated with thickness of section not less than1.5mm (minimum thickness of powder coating 50 micron) for frames of doors, windows, ventilator, partitions, fixed portion and frames with extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note:- Glazing and paneling to be paid for separately. |
| 28 | S&F anodised aluminiumPowder coating door shutters side hung/ sliding door with aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, ruber neoprene packing , hinges,anodised aluminium snap beading screws,all necessary builders hardware etc complete all as specified. |
| 29 | S&F anodised aluminiumPowder coatingwindow and ventilator shutters, side hung type without sash bars aluminium section weighing not less tha 0.55Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150mm long (1no), hinges type B-21 100mm long(2 no.) suitable handle (1 no) including all necessary builders hardware complete all as specified. |
| 30 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle with decorative lamination on one side and balancing lamination on other side board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. |
| 31 | Providing and fixing glazing With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. |
| 32 | S & F MS Framed work rolled sections, angle, tubular pipe or other sectionriveted, bolted or welded in built up sections, trusses, framed work as in fire exit staircase, stringers, treads, landing, balusters,electric trench frame work, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; hand rails etc, including cleats, brackets, of Fe 290 (Grade E-165) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and directed. |
| 33 | M&L MS Plates (plain or chequered) channels, Fe 290-165 square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed |
| 34 | M&L Expanded metal, wt n exc 4 kg/sqmcut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified |
| 35 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking GI metal grid of hot dipped galvanized steel sections consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture having 7 to 8 mm thick square edge PVC Laminated Gypsum board Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge |
| 36 | M&L Complete removal of existing roof treatment including brick tile, mud fusca,PCC padding,cowa, lime concrete etc up to any thickness and depth of original roof slab and Clean up to existing RCC roof by steel wire brushes and surface washed with clean water and complete all as specified and directed by Engr-in- charge.Note: All Demolished material / mud phuska sand/ brick tiles will be taken by the contractor out side of the Defence land without any extra cost to the govt. |
| 37 | M&L PCC 1:3:6 type C1 using 20 mm graded stone aggregate as inmass concrete over roof as in padding incl cement slurry over old RCCsurface, surface fair finished even & smooth without using extra cement all as specified and directed by Engr-in- charge. |
| 38 | M&L 15 mm thick layer of screed bed/ bedding layer in CM 1:4 over concrete surfaces of roofs surface finished even and smooth mixed with WPC @ 3% by weight of cement complete all as specified and directed. |
| 39 | M&L Applying a coat of approved bituminious primer @0.25 ltr/Sqm and allow to dry conforming to IS: 3384 -1965 all as specified and directed by Engr-in-charge. |
| 40 | Supplying and laying APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/Sqm ) laid on by torch forced application.The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction and 100mm overlap on all vertical surfaces/dado/parapets etc and sealing the overlaps by hot blown bitumen grade 85/25heating and fusing the layer of asphalt and melting the protective plastic filmcomplete all as specified and directed |
| 41 | M&L for applying two coats of bitumen based aluminium painting@ 0.2 Kg/Sqm on water proofing treatment with preparation of surface as on non assesible area complete all as specified and directed. |
| 42 | M&L preparation of newly plastered surfaces of ceiling and applying two coat of oil bound distemper(white or tinted) over a coat of alkali resistant primer, complete all as specified and as directed. |
| 43 | Dismentling of boarding, any description, fixed in any positioin with nails complete all as specified |
| 44 | S&F powder coated Gl frame work for seamless ceiling/wall comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centrecomplete all as specified and directed. |
| 45 | M&L for non-skid joint free coloured ceremic tiles 7 to 8 mm thick,(Square/rectangular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed |
| 46 | M&Lfor vitrified ceremic tiles 8 to 9 mm thick,in lightshade,(Square/rectangular) polished, area of each tilenot exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed |
| 47 | M&Lfor vitrified ceremic tiles 8 to 9 mm thick,in lightshade,(Square/rectangular) polished, area of each tilenot exceeding 0.36 sqm, in skirting/dado etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 10 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed |
| 48 | S&F in repairs vitreous china Urinal, Half stall type of size white including connections to flushing pipe and outgoing pipes complete all as specified and directed. |
| 49 | S&F as in repairs 10 ltrs capacity PVC low level flushing cisternvalveless,syphonic action type with inlet ball valve float and handle including brackets complete all as specified and directed. |
| 50 | S&F toughened glass partition for urinals 10 mm thick etched glass of size 600 x900mm with support of CP frame fancy type as approved by GE complete all as specefied and directed by Engr in chrge. |
| 51 | S&F as in repair urinal spreader CP coated for fixing with 15 mm dia PVC connection pipe complete all as specified and directed. |
| 52 | Supply and fixing 15mm dia PVC connection with brass nut, of length 600 mm,fixed as in repairs, complete all as specified and directed. |
| 53 | S&F as in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 54 | S&F in repairs soap dish chromium plated of size 100 x 100 mm any type, fixed with chromium plated brass screwscomplete all as specified. |
| 55 | S&Fin repairs wall mounted liquid soap dispensor chromium plated, fixed with chromium plated brass screwscomplete all as specified. |
| 56 | S&F in repairs 15mm dia bib tapcast copper alloy chromium plated but fancy type, long body quarter turn complete all as specified and directed. |
| 57 | S&F in repair 15mm dia brass chromium plated pillar tap (swan neck) fancy type with fly nut capstan head screwed quarter turn complete all as specified and directed. |
| 58 | S&F in repairs 15 mm dia stop valve chromium plated { with long shank (concealed type) cast copper alloy screwed down high pressure quarter turn complete all as specified and directed. |
| 59 | S&F in repairs 15 mm dia angle valve chromium plated brass quarter turn complete all as specified and directed. |
| 60 | S&F in repair vitreous china WHB oval shape under/over counter white of size 550X460 mm including CP waste coupling etc complete all as specified and directed . |
| 61 | S&F in repairs CP brass bottle trap 32 mm dia including joining to waste fitting and waste pipe complete all as specified and directed. |
| 62 | S&F in repairs CP grating 100/125 mm dia round fix on floor / nahani trap fixed with cement morter complete all as specified and directed. |
| 63 | S & F in repairs vitreous china pedastal pattern, \"EWC\"white withconnection to trap, and to flushing pipe anti-syphonage pipe and including PVC sheet cover and CP jet etc. complete all as specified and directed. |
| 64 | S&F in repairs plastic water closet seat cover white closed pattern with flat bottom end cover and mild steel chromium plated hanging device complete all as specified and directed. |
| 65 | S&F in repairs vitreous china Squatting pan Orissa pattern of size 580X440 mm white with integral foot rest water closetincluding provn of lime concrete bedding including connections toflushing cistern/pipe and making good disturbedportion to match existing surface complete all as specified and directed. |
| 66 | S&F In repair 16 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceilings or laying in floorscomplete all as specified and directed. |
| 67 | S&F In repair 20 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceilings or laying in floorscomplete all as specified and directed. |
| 68 | S&F In repair 25 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceilings or laying in floorscomplete all as specified and directed. |
| 69 | S&F in repairs 600mm x 450mm x 5 mm thick bevelled edge looking mirror of selected quality glass with aluminium frame of channel alround mounted on 4 mm thick commercial ply or AC building boardfitted to wooden plug with CP brassscrews complete all as specified and directed. |
| 70 | Supply and fixing for frameless looking mirror 5.50mm thick of required size with bevelled edges and approved border design of selected quality glass,mounted on wall surfaces with fancy type SS screws having SS cover caps visible on mirror surface including Plastic protector cover for edges oflooking mirror complete all as specified and directed. |
| 71 | S&F in repair health faucet (hand jet) ABS body mild steel chromium plated suitable for 15 mm dia pipe with 1.25 M long flexible tube and ABS wall hooks including making connections and fixed in position complete all as specefied and directed. |
| 72 | S&F in repairs CP jet spray with tube for single symphonic EWC complete all as specified and directed. |
| 73 | S&F in repairs 32mm/40 mm dia PVC waste pipe for WHB/Urinal 60cm long with union complete all as specified and directed. |
| 74 | S&F in repair Stainless steel sink with drain board, made out of 1.00mm thick sheet for kitchen or laboratory with plug waste pipe, washers including cantilever cast iron brackets connecting union etc. overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 75 | Material and labour for 16 to 18mm thick granite stone slab as in floor or shelves, over cooking platform,pillers,cills etc machine cut bedded and jointed with grey cementslurry and pointed with white cement with admixtur of pigment to match the shade of granite stone including grinding, moulding and polishing and beveling half round edges of stoneslaid over 15 mm thick sereed bed in CM (1:6) etc complete all as specified and directed. |
| 76 | Demolition of RCC any thickness and any size as in columns, roof slab, chajja, facia and beam etc complete all as specified and as directed. |
| 77 | M&L RCC M-25 design mix using 20 mm graded stone aggregates as in Foundations, including rafts, footings, Foundation beams; plinth beams; bases for columns, Shelves etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 78 | Material and labour mild steel 10 mm dia and over TMT bar cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 79 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 80 | S&F in repairs 20mm dia brass chromium plated tubular towel rail of size 60 cm long including brackets. complete all as specified and directed. |
| 81 | Supply and fixing in repairs brass chromium plated tubular towel ring having dia of ring not less than 150mm fixed to walls with necessary screws complete all as specified |
| 82 | M&L forchipping of spalled and loose concrete and cleaning rust from reinforement by sand blasting scrubbing down concrete surface with wire brushes cleaning with water allowed to dry and applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bounding coat of approved epoxy adheisve on complete exposed surfaces of concrete to be gunited all as specified and applying two layers of guniting over steel welded mesh 2mm dia of wire and aperature 75mm, avarage thickness of gunite n.exc 40mm thickin cement mortor (1:2) using OPC 53 grade cement mixed with polycrete admixture @ 2% by weight of cement or as per manufacturer instructions and finally applying cement plaster over gunite surface of required thickness to giveeven uniform and smooth finish conforming to proper geometrics in cement mortor (1:3) to match the existing surface as in sides and soffits etc of slabs, chajjas, fins, facias,parapets, lintels, columns and beams etc complete including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 6 storey building including removing of small trees shrubs etc all as specified and as directed |
| 83 | Taking down chowkhats or frames Exc 1.5 sqm but n.exc 4 sqm(without taking off shutter from the frame) each complete all as specified and directed. |
| 84 | S&F Fiber glass reinforced plastic(FRP) door frame of cross section 90 mm X 45 mm having single reveted of 32 mm X 15 mm to receive shutters of 30 mm thickness.The laminate shall be moulded with fire resistsnt grade unsaturated polyster resin and chopped mat. Door frame shall be laminated 2 mm thick and shall be filled with suitable wooden block in all the three legs.Frame shall be covered with fiber glass from all sides. MS stay shall be provided at th bottom to steady the frame all as specefied and directed. |
| 85 | S&F to existing door frames 30 mm thick FRP panelled door shutter of required colour and approved brand and manufacture,made with fire-retardant grade unsaturated polyster resin,moulded to 3 mm thick FRP laminate for forming hollow rail and stylewith wooden frame and suitable block of seasoned wood in side the required placefor fixing of fittings,cast monolothically with 5 mm thick FRP laminate for panells confirming to IS:14856 all as specefied and directed. |
| 86 | S&F 100mm size butt hinges, medium weight cold rolled mild steel all as spd and directed |
| 87 | S&F 150 mm long aluminum anodized barrel tower bolt of extruded section all as spd and directed |
| 88 | S&F 150mm size aluminum handles cast type, anodized all as spd and directed |
| 89 | S&F 250mm long aluminum alloy anodized sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts andsliding bolts of extruded section or cast aluminum alloy all as spd and directed |
| 90 | S&Fin repair aluminum alloy door closer hydraulically regulated, desination No 2 universal type, suitable for door shutters of 701 to 850mm in width and weight between 36 to 60 Kg and fixed to door frame complete all as specified and directed. |
| 91 | S&F in repair 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 92 | S&F in repair 110 mm bore PVC (SWR) bends with rubber ring joints complete all as specified and directed. |
| 93 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including clamps as required, fixed as in repair complete all as specified. |
| 94 | S&F 75mm dia PVC (SWR) bends with rubber ring joints fixed as required complete all as specified. |
| 95 | Taking down of Old unserviceable point wiring any type for light, fan, power etc includingunserviceable switch,socket, regulator and ceiling rose etc of any make complete including making good disturbed surfaces of walls, floors roof etc complete all as specified and directed. |
| 96 | Supplying and fixing 05/06 Amp modular switch on the modular plate & switch box including connections but excluding modular plate etc. as required |
| 97 | Supplying and fixing 15/16 Amp modular switch on the modular plate & switch box including connections but excluding modular plate etc. as required |
| 98 | Supplying and fixing 05/06 Amp modular Socket outlet 3 pin 5/6 Amp including connections but excluding modular plate etc. as required |
| 99 | Supplying and fixing 15/16 Amp modular Socket outlet 6 pin 15/16 Amp including connections but excluding modular plate etc. as required |
| 100 | S&F for TP&N vertical load line DB double door with provision of MCCB as Incomer upto suitable 100 Amps, 415 volts 4 way, 50 Hz complete all as specified and directed by Engr-in-charge. Make: Legrand Cat part No. 507753 (Note: The cost of MCCB and MCBs shall be measured and paid under separate item) |
| 101 | Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required |
| 102 | S&F MCCB of 04 pole 100 amp, TPN, 16 KA (Ics=Icu=100%)thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed. |
| 103 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 6 to 32 Amps poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 104 | S&F energy efficient LED light fitting, slim LED panel, recessed mounting 2 ftx 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT>90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed. |
| 105 | S&F energy efficient LED light fitting surface mounted 4\" long, 20 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI > 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed. |
| 106 | M&L for Wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor,single core cable in surface/recessed of size 4X10 sq mm + 2X6 Sq mm earth wire including suitable size ofPVC conduit and lugs/thimble with nuts,bollts and washers etc completeincluding taking down of existing unserviceable wiring. |
| 107 | Material and Labour for earthing complete with copper plate electrode 600mmx600mmx3.15mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.Copper plate connected with copper earth strip 20x3mm by means ofnuts, bolts and washers.Copper striplaid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:-(a)Copper strip 20x3mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. |
| 108 | M&L copper strip 20mmx3mm buried in ground including necessary excavation & earth work in soft/loose soil and removal of excavated material to a distance not exceeding 50 mtrs and deposited where directed including taking out old unserviceable complete all as specified and directed. |
| 109 | Supply and laying in trenches, fixed to wall / pole/ tray etcUG cable XLPE insulated armouredheavy duty electric UG cable with aluminiumconductor1100 volts grade of cross sectional areaof 35 Sqmm 3.5 Core complete all as specified and directed. |
| 110 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louverscomplete all as specified and directed. |
| 111 | Supply and fix wall mounting fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and framecomplete all as specified and directed. |
| 112 | M&L for point wiring with PVC insulated unsheathed FRLS wire 1.5 sqmm multi stranded two single copper conductor cable passing through in existing PVC/steel conduit pipe complete with all accessories and with 1.5 sqmm PVC insulated copper cable FRLSas continous earth wire with recessed mounting GI sheet box with cover plate suitable for modular switch of adequate size including cutting chases in wall where required for inserting new conduit being included and making good the distrubed surface to match with the existing completeincluding taking down existing old aluminium/copper wiring all as specified and directed for followings :- |
| 113 | (a)One light/ fan point controlled by one switch with copper cables 1.5 sqmm size. |
| 114 | (b)One 3 pin socket outlet on independent board. |
| 115 | (c)One 3 pin socket outlet on same board. |
| 116 | All as per item No 112.01 here in before but for one socket point out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor FRLSH and 2.5 sqmm PVC insulated copper conductor FRLSH as earth continuity conductor complete all as specified and directed. |
| 117 | M&L for power point wiring concealed type with PVC insulated unsheathed copper cable FRLS 4 sqmm multi stranded two single copper conductor in Including 20mm diaPVC conduit pipemidium grade complete with all accessories and with 2.5 sqmm PVC insulated copper cable FRLS continous earth wire, re-recessed mounting pressed steel (mild steel) sheet box suitable for modular switch/sockets/AC metal clad socket of adequate size complete all as specified and directed.Note For item no 112 to 114 -: (a) Any civil work such as falls ceiling, POP, cutting of window glass/plybood taking down and refixing / repairing work such as ceiling, POP, cement plaster,window glass,plybood, white/colour wash and E&M fitting and fixture,wire connection, taking downand refixing as same on site, rate to be deemed in quoted rate.(b)No other extra payment shall be madeto the contractor in ths account. |
| 118 | Supply and fixing in replacement of modular switch single pole one way6 Amps 1 module complete all as specified and directed. |
| 119 | Supply and fixing in replacement of modular switch single pole one way 16/20 Amps 1 module complete all as specified and directed. |
| 120 | M&L in replacement of modularsocket 6 A/16 amp -3/5 pin combined 2 module complete all as specified and directed. |
| 121 | M&L in replacement of modularsocket 6 A-2/3 pin combined 2 module complete all as specified and directed. |
| 122 | S&F in replacement ofceiling rose, surface bakelite 65x50mm three terminals complete all as specified and as directed. |
| 123 | S & F in replacement of electronic fan regulator 240 V step type single pole complete all as specified and directed . |
| 124 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps Note Rate to be demmed for cutting and chasing making good surfacewhit wash /distamper matching as per existing . |
| 125 | S&F for SPN DB with 63 Amps rated bus bar, double door with 230 volts 8 way, 50 Hz complete all as specified and directed by Engr-in-charge. |
| 126 | S&F for SPN DB with 100 Amps rated bus bar, double door with 230 volts 12 way, 50 Hz complete all as specified and directed by Engr-in-charge. |
| 127 | S&F MCB SPN 40 Amps C curve,10 KA complete all as specified and directed. |
| 128 | M&L in replacement ofSub main wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor,single core cable in surface/recessed of size 2X10 sq mm + 1X6 Sq mm earth wire including suitable size ofPVC conduit of size 25mm dai medium grade and lugs/thimble with nuts,bollts and washers etc complete all as specified and directed. |
| 129 | M&L in replacement of Wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor,single core cable in surface/recessed of size 2X16 sq mm + 1X6 Sq mm earth wire including suitable size ofPVC conduit of size 25mm dai medium grade and lugs/thimble with nuts,bollts and washers etc complete all as specified and directed. |
| 130 | M&L in replacement of sub main wiring with two run of single core PVC insulated FRLS stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductordrawn in and in existing surface PVC conduit concealed medium grade complete all as specified and directed. |
| 131 | S&F in replecement energy efficient LED light fitting, slim LED panel, recessed mounting 2 ft x 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT>90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed. |
| 132 | S&F in replacement energy efficient LED light fitting surface mounted 4\" long, 20 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI > 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed. |
| 133 | Supply and fixing round/square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed. |
| 134 | Supply, installation, testing and commissioning of Hi wall mounted, high efficientSplit type, Five Star rating (as per leatest rateing) ofBEE air conditioner inverter type of following capacity, Machines confirming to latest Indian Standards and suitable for operation on 230 Volts + 10 %, single Phase, 50 Hz AC supply with cooling capacity 5275 watt and cordless remote and durecell batteries unit shall comprise of separate Indoor and outdoor unit of 1.5 ton as specified. |
| 135 | a. Indoor (fan coil) unit shall be Wall Mounted type comprising of Fan, Two way air discharge and 2 Row Deep DX coil with finned copper tubes duly coated with anti corrision and thermally conductive coating, T-Flow Fan unit with direct drive Motor ,unit shall have proper air circulating, auto mode, auto swing, anti bacteria filtering, ventilation with remote control having Cool/Fan/Dry/Auto mode, sleep mode & on/off timer with suitable thermostat and insulated & leak proof condensate base complete all as specified and as directed by EIC. .b. The outdoor (condensing unit) shall be of Corrosion resistant Galvanized powder coated or equivalent Sheet steel low vibration assembly installed on suitable vibration isolators and comprising of energy efficient hermetically sealed Rotary / Reciprocating compressor operating on R 32/ R 410a refrigerant with copper condenser coilsand unit shall have proper insulated & leak proof condensate base. The units shall be installed on M.S channels, angles, flats fram welded structure of appropriate size & thicknesses duly painted with anti corrosive paint (Expoxy , welded structure and anti vibration Isolated pad complete all as specified and as directed by EIC. |
| 136 | Note: (i) 3 mtrCopper pipping duly coated with anticorrision and thermally conductive coating with insulation and PVC flexible copper cable of suitable size as per OEM shall be deemed including in coated rate and if more than 3 mtr copper pipping is required shall be measured and paid seperatly.(ii) Warranty ofSplitAC unit is 2 Years, Compressor is 10 Years and PCB/controller ofis 5 Years(iii)The units shall be installed on MS angle iron frame welded structure (measured and sepatate item) with duly with anti-corrosive paint (Expoxy) and anti vibration Isolated pad. (iii) The rate should include civil work required to be executed in order to make the Airconditioning system installed & put in working condition. The item includes making holes/gaps in walls to pass duct & pipes, making zaries required for various types of drain, refregerent Civil work required to be executed in order to make the Airconditioning system installed & put in working condition. The item includes making holes/gaps in walls to pass duct & pipes, making zaries required for various types of drain, refregerent & drain water pipes/ lines in walls, floor etc. using cutter machine, including core cutting as per site requirement, refinishing on all the side with rich cement mortar to match the surrounding original finised surfaces to put the entire work in order. While crossing the wall, a heavy duty PVC pipe sleve shall be fixed of the total wall thickness & shall be finished from out with rich cement mortar & from inside with white cement. No extra will be paid for any civil work related to AC work. in walls, floor etc. using cutter machine, including core cutting as per site requirement, refinishing on all the side with rich cement mortar to match the surrounding original finised surfaces to put the entire work in order. While crossing the wall, a heavy duty PVC pipe sleve shall be fixed of the total wall thickness & shall be finished from out with rich cement mortar & from inside with white cement and painting with existing color. |
| 137 | Supply, installation, testing and commissioning of Highly Efficient ceiling suspended, 4-way air flow CASSETTE TYPE AIR CONDITIONERS of capacity 4.0 Ton,230V, single phase, 50Hz, AC, inverter type, 4 star or higher, confirming to latest Indian Standards duly comprising of indoor and outdoor units. The indoor unit comprising with multi-row DX type copper cooling coil with anti corrison and thermally conductive coating, driver, expension valve/devices, air blower with copper wound motor and other connected accessories. Outdoor unit complete withhermetically sealed, rotory/scroll compressor operating on R-32/R-410a, copper condensor coil with anti corrive coating, fan and other connecting accessories, full function cordless remote controller with batteries( |
| 138 | (vii) 3 mtrCopper pipping duly coated with anticorrision and thermally conductive coating with interil insulation of suitable size as per OEM shall be deemed including in coated rate and if more than 3 mtr copper pipping is required shall be measured and paid seperatly. (viii) Warranty ofCASSETTE TYPE AIR CONDITIONERS unit is 2 Years, Compressor is 10 Years and PCB/controller ofis 5 Years |
| 139 | Supply & fixing wall mounted Voltage Stablizer of capacity 4.0 KVA single phase, 50 Hz AC supply with Hi & Low cut off, surge protection, High voltage protection, In-bulit thermal overload protection and ITDS, copper wound with efficiency 95% at nominal load and voltage range input voltage range 140 to 280 volts and output voltage 230 Volt ± 1%, air cooled with digital display complete all as specified and as directed. |
| 140 | Supply & fixing wall mounted Voltage Stablizer of capacity 5.0 KVAsingle phase, 50 Hz AC supply with Hi & Low cut off, surge protection, High voltage protection, In-bulit thermal overload protection and ITDS, copper wound with efficiency 95% at nominal load and voltage range input voltage range 140 to 280 volts and output voltage 230 Volt ± 1%, air cooled with digital display complete all as specified and as directed. |
| 141 | M&L for one pointwiring of with PVC insulated FR LSH unsheathed coppercable of size 4.0 sqmm including earth wire of size 4.0 Sqmm inand including Concealed rigid 20 mm dia PVCconduitincluding GI sheet box and white modular Inner/Outer cover plate with frame, for 15 amps power pointincluding cutting chases for conduit where required andmaking good to wall and ceiling completeall as specified and as directed . |
| 142 | M&L for sheet metal enclosures with plug top and MCBs single pole and natural enclosures with two pin and earth plug and socket complete with one single pole MCB 32A\"C\" curve capacity all as per directed. |
| 143 | S & F in replacement of electrolyte grade copper tubing of size 3/8\" suitable for any type ofsplit type ACincluding synthetic rubber foam complete all as specified and directed. |
| 144 | S & F in replacement of electrolyte grade copper tubing of size 5/8\" suitable for any type ofsplit type ACincluding synthetic rubber foam complete all as specified and directed. |
| 145 | Supply and fixing Flexible PVC with nylon braided heavy duty AC drain pipe 20 mm dia in and including supporting clamps/hungers etc. and it should be connected to the nearest rain water pipeline/drain pipe .. The item includes making holes/gaps/ chiseling in walls to pass pipes as per site requirement, refinishing on all the side with rich cement mortar to match the surrounding original finised surfaces to put the entire work in order complete all as specified and directed. |
| 146 | S&F in replacement AC stand suitable for out door splitAC unit up to cap of 2 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete allas specified and as directed. Note : No other/extra payment shall be madeto the contractor in ths account. |
| 147 | Supply and Fix 40 Itr cooling capacity fully stainless steel water cooler of storage capacity 80 Ltr, 230 V, 50 Hz, all as specified and directed. |
| 148 | Wiring for light point/fan point/exhaust fan point/call bell point with 2.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate suitable GI box and earthing the point with1.5 sq mm FRLS pvc insulated copper conductor single core cable etc complete all as specified and directed. |
| 149 | S&F SPN-DB 6 way, 230 volts, 50 HZ concealed on wall including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white /colour washing/distempering etc to the disturbed surfaces to match the existing completeall as required or all as specified and as directed. |
| 150 | M&L in replacement wiring for circuit/submain wiring along with earth wire with the 2x 6.00 sqmm+6 sq mm earth wire of FR LSH PVC insulated copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories completeall as required or all as specified and as directed. |
| 151 | Supply, installation, testing & comissioning of high efficient non inverter window type three star rating (as per latest rating) of BEE air conditioner of 2.0 TR capacity, machines confirming to latest ndian standards and suitable for operationon 230 volts + 10 %, single phase, 50 hz, AC supply with cooling capacity 5275 watt and cordless remote and 02 nos of duracell batteries inclding cutting windows as per the size of Air conditioner, placing the window AC and covering the extra area of window with plywood sheet all as specified and directed. |
| 152 | Supply and fix Voltage stabilizer for automatic operation, single phase of capacity of 5.0 KVA,naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 Voltage with accuracy of + 2.5% complete all as specified and directed. |
| 153 | M&L for one pointwiring of with PVC insulated FR LSH unsheathed coppercable of size 4.0 sqmm including earth wire of size 4.0 Sqmm inand including Concealed rigid 20 mm dia PVCconduitincluding GI sheet box and white modular Inner/Outer cover plate with frame, for 15 amps power pointincluding cutting chases for conduit where required andmaking good to wall and ceiling completeall as specified and as directed . |
| 154 | Supply & Laying of drain piping carried out of UPVC pipes 25 mm dia, with solvent joints forSplit units, up to the nearest drain complete all as specified and directed. |
| 155 | Supply, installation & testing Heavy duty desert cooler in FRP (Fiber reinforced plastic), weather resistant body with wheels (4 Nos), high efficiency honeycomb pads with anti-microbial property, collapsible louvers, auto swing wide angle air flow, 150 ltrs tank capacity, 6000 to 8000 cfm air flow capacity, heavy duty copper wound fan motor with three speed single phase, 230V, 50 Hz, with thermal over load protection, and 80 feet air through in and including pvc insulated 2.5 sqmm, 3 core flexi cable copper conductor cable with 3 pin plug top complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy