| 1 | Surface excavation n exc. (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil, all as specified and as directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of underground cables etc. or for shafts, wells, cesspits, manholes, pier holes, under groung cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil, complete all as specified and directed. |
| 3 | Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed. |
| 4 | Returning, filling in,including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil all as specified and directed. |
| 5 | M&L for plain cement concrete (1:4:8), type D2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed. |
| 6 | M&L for plain cement concrete(1:3:6), type C-2(40 mm graded stone aggregate) in surface channels and drains including all necessary form work, complete all as specified and directed. |
| 7 | M&L for hardcore using broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 8 | M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 9 | M&L for pre-cast cement concrete block masonry (1:3:6), type C-1 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and as directed. |
| 10 | M&L for 15 mm thick rendering in cement mortar (1:6) on stone masonry surfaces or surfaces onfair faces of brick or concrete surfacework, rendering finished even and smooth (without using extra cement), complete all as specified and directed. |
| 11 | M&L for rendering 20mm thick (two layer, 10mm and 10mm thick) in cement mortar (1:4)on newbrick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed. |
| 12 | M&L for walling of random rubble or polygonal rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement morter (1:6) including brought up to course at interval of every 60cm, complete all as specified and directed. |
| 13 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with mild steelwire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 14 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed. |
| 15 | S&F of rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed. |
| 16 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed. |
| 17 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete on flat surface, complete all as specified and directed. |
| 18 | S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. |
| 19 | M&L preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash on wall, complete all as specified and directed. |
| 20 | M&L for 75 mm thick plain cement concrete(1:4:8), type C2(40 mm graded stone aggregate) as in Subbase flooring, plinth protection, hard standing, path etc including50 micron polythene complete all as specified and directed. |
| 21 | M&L for 40mm thick plain cement concrete(1:2:4), type B-1, (using 20mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment etc., complete all as specified and directed. |
| 22 | M&L for coloured non-skid ceramic tiles 7 to 8 mm thick, premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match includingscreed bed or bedding layer of mortar 20 mm thick for laying floor finishes in cement mortar (1:6), complete all as specified and directed. |
| 23 | M & L glazed ceramic coloured tiles 300 x 200 x 7 mm thick,in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match over and incl 10mm thick screed bed in cm 1:4 in dados/skirting complete all as specified and directed. |
| 24 | S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed. |
| 25 | S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed. |
| 26 | S&F of 75 mm sizebutt hinges, medium weight, cold rolled mild steel and fixed, all as specified and directed. |
| 27 | S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, all as specified and directed. |
| 28 | S&F of 125 mm size aluminium handles, cast type, anodised, all as specified and directed. |
| 29 | S&F in repair 15mm bore dia stop valves, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. |
| 30 | S&F of PVC connections 15mm size with PTMT nuts of length 450mm, all as specified and directed. |
| 31 | S&F of PVC (SWR) pipes single socketed 75mm bore, in any length with rubber ring joints, laid in trenches or in floors/weep hole or fixed to wallscomplete all as specified and directed. |
| 32 | S&F of 75 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed. |
| 33 | S&F of PVC (SWR) pipes single socketed 110mm bore, in any length with rubber ring joints, laid in trenches or in floors/ fixed to wallcomplete all as specified and directed. |
| 34 | &F of 110 mm bore PVC (SWR) bends any radius, complete all as specified and directed. |
| 35 | S&F of 110mm bore PVC (SWR) junction single, (Single T) equal or unequal including jointing with solvent cement, complete all as specified and directed. |
| 36 | S&F of 110 mm bore PVC (SWR) vent cowlincluding jointing with solvent cement, complete all as specified and directed. |
| 37 | S&F of 110 mm PVC (SWR) \"P’ trap or \"S\" trap, all as specified and directed. |
| 38 | S&F for vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect, all as specified and as directed. |
| 39 | S&F of PVClow level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and directed. |
| 40 | S&F of health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, complete all as specified and directed |
| 41 | S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 42 | S&F in repair vitreous china wash basin, white, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, taps, chain and plug and porcelain stopper but including bracketsincluding 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, all as specified and directed. |
| 43 | Supply only liquid water proofing compound, all as specified and as directed. |
| 44 | S&F of 15 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces,back nuts, unions, caps and plug etc ) and fixed complete to wall and ceilingor laid in/on floor, complete all as specified and directed. |
| 45 | S&F of 20 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces,back nuts, unions, caps and plug etc ) and fixed complete to wall and ceilingor laid in/on floor, complete all as specified and directed. |
| 46 | S&F of rotational moulded polyethylene water storage tanks of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-l including 25 mm bore dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) included connection and dismantling water tanks of capacity 500 litres and removing to store, complete all as specified and directed. |
| 47 | Supplied and fixed of 20 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 48 | M&L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed. |
| 49 | S&F of wall mixer with bend pipe with built in non return valve with all fitting, complete all as specified and directed. Make: Essco MQT-517BKN or equivalant |
| 50 | S&F for 15mm bore dia of pipe, brass CP mixer for mixing hot and cold water screwed down for iron pipe and fixed suitable for wash hand basin flat back / kitchen sink, complete all as specified and directed. |
| 51 | M&L for 75 mm thick plain cement concrete(1:3:6), type C2(40 mm graded stone aggregate) as in flooring, plinth protection, hard standing, path etc including finish the surface even and smooth with using extra cement including panels not exc 2.00 Sqm each including construction joint at suitable interval and each corner and filled with bituminous mastic filling ( 1 part bitumen and 3 part sand)CM 1:6complete all as specified and directed. |
| 52 | Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and includingrigidnonmetallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring, for one light point or one fan point or one bell point controlled by one switch, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion. |
| 53 | All as per item No 52 here-in -before but One socket outlet/metal clad socket of 5 Amps fixedon independent board with 1.5 Sq.mm multistranded copper condutor wire FRLS PVC insulated and 1.5 SQ.mm copper coundutor wire FRLS PVC insulated using as earth wire complete as specified and directed by Engr-in-Charge. |
| 54 | All as per item No 52 above but One switch socket outlet point 5/6 Amp on same board with other switch |
| 55 | All as per item No 52 here-in -before but One socket outlet/metal clad socket of 15 Amps fixedon independent board with 2.5 Sq.mm multistranded copper condutor wire FRLS PVC insulated and 2.5 SQ.mm copper coundutor wire FRLS PVC insulated using as earth wire complete as specified and directed by Engr-in-Charge. |
| 56 | Supply and fix switch piano flush type single pole , one way 6 Amp 230 Volts,50Hz, ISI marked all as specified and as directed.Make:Havells/legrandor equivalent |
| 57 | S&F of switch socket combination 2 in 1, 3 Pin / 5 Pin, 5 Amps / 6 Amps flush non shutter, non inter locking type 230 volts flush type, white/ivory finossh with two fixing hole including suitable gang box, complete all as specified and directed. |
| 58 | M&L for switch socket combination 2 in 1, 6 pin, 5 /15 Amps multipurpose flush non shutter, non inter locking type 230 volts flush type, white/ivory finossh with two fixing hole including suitable gang box, complete all as specified and directed. type universal, all as specified and directed. |
| 59 | S&F ceiling rose, 3 termanal and 240 volts ,PVC polycarbonate ,insulated body (ISI Marked) complete all as specified and directed. |
| 60 | Supply and fixing of sheet metal enclosure, double door for MCB DB\"s, 4 way single pole & neutral (SPN) double door with IP-43 protection suitable for fixing MCB\"s/Isolators, complete all as specified and as directed.. |
| 61 | Supply and fixing for MCB single pole & neutral 32 to 40 Amps, 240 Volts, 10 KA rapturing capacity \"C\" Curve , all as specified and directed. |
| 62 | &F MCB single pole 6 to32 Amps , 240 Volts , 10 KA rupturing capacity , C curve complete all as directed |
| 63 | Supply and fixing of LED lights fitting 1x 18W (4 Ft) CRI>=80, CT>=5700, wall surface mountd, integrated type condtruction of fire retardant engineering grade extrded plastic & decorative end caps with interated high efficiency driver & surge suppressor of 2 KV or more, luminaire efficacy >95 lumens/Watt power factor >/0.90 operating range - 140 to 270 V 50 Hz with suitable fixing arrangements complete 01 No 18 W 4 Ft LED lamp with all accessories internally prewired and including connecting connecting up with incuding twin wire core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 64 | S&F of water proof LED light fitting 1x9 Watt / 1X10 Watt bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, all as specified and directed. |
| 65 | M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burrieddirectly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected with galvanised iron/steel earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plateNo 3 of SSR Part-I and earth wire protected by galvanized pipe light grade 15mm bore andconnectedto DBs including necessary earthwork and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed by Engineer-in-Charge .Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge. |
| 66 | Supply and fix of non metallic ventilating fan, 200 mm sweep 900 rpm AC single phase 230 volts including louvers, connecton with multistranded copper condutor flexible wire of sutable size from ceiling rose, nessary fixing arrangement i.e. anchor nut bolt washer and grouting and making good to disturbed surface complete all as specified and directed. |
| 67 | Supply and fix electric water heater(Geyser), storage typewith copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated with all accessories such as safety valve, thermostate, NRV, connection piece etc, and connecton with multistranded copper condutor flexible wire of sutable size from ceiling rose, nessary fixing arrangement i.e. anchor nut bolt washer and grouting and making good to disturbed surface complete all as specified and directed. |
| 68 | Supply, Laying, Jointing and testing in tranches/ through pi[es/ducts or on poles/ walls jointing to O/H conductor, LT plnels, main switch with cable size aluminum lugs and tested. XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables, heavy duty 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 2 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed. |
| 69 | Supply and laying DWC pipe SN-4 with coupler 50mm OD, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, PartII complete with fitting and cutting , jointing etc. Laid in trenches/fixed to pole /laying under road crossing /fixed on pavement wall with clamps complete all as specified and as directed. |
| 70 | S&F of GI tubing of 40 mm bore medium grade ISI Marked fixing on wall jointed tested and commissioned including all fittings such as elbow, union, reducer, tees, bends etc and shortlength, complete all as specified and directed. |
| 71 | Supply and laying testing steel water tubing medium grade with all fitting fixed to wall/ceiling or laid in floor of size 25 mm bore all as specified and directed. |
| 72 | S&F Gun-metal, globe or gate valves, ISI marked, 25mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed |
| 73 | Cutting existing steel tubing for alterations or additions (Each cut measured) and screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector), necessarily done in position without taking down, complete all as specified and directed. |
| 74 | Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates.Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. |