| 1 | Framed work such as grills. gratings etc. with ends of bars shouldered and/or riveted. or forget into spikes, framed guard bars, barred iron doors,ladders framed balusters, walk ways, railings. framework of water tanks and similar work conforming to Fe 290 Gde E-165, complete all as specified and directed. |
| 2 | M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 3 | Brick work with subclass \"B\"\" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1.6 of using class designation 100 of bricks in lteu of 75, complete all as specified and directed. |
| 4 | M&L for 15mm thick rendering in CM 1·6 on fair faces of brick work. surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 5 | M&L for Preparation of new plastered surface of wall and applying two coats of cement base paint over a coat of primer including balance area complete removal, complete all as specified and directed. |
| 6 | M&L for 75mm thick PCC (1:2:4) type C-2 using 20mm crushed stone aggregate as in sub base/ flooring, complete all as specified and directed. |
| 7 | M&L for 25mm thick plain cement concrete type B0, 1 :2:4 (using 12 5 mm graded stone aggregate), as levelling course, complete all as specified and directed. |
| 8 | M & L for Non Skid Heavy duty Outdoor ceramic tile 400x400x 12mm thick coloured joint free in floors etc set and Jointed in neat cement slurry and pointed in colored cement to match over and including 15mm thick screed in CM 1:4, complete all as specified and directed. |
| 9 | Excavation in post holes (or similar holes) each n exc 0.5 Cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 10 | Removing excavated soil n.exc 50m and depositing where directed at a level n.exc1.5m above the starting point etc., complete all as specified as directed. |
| 11 | M&L forPCC 1:4:8 type D-2 (40mm graded crushed stone aggregate) Cement concrete in foundations filling and mass concrete etc., complete all as specified as directed. |
| 12 | M&L for Pre- painted galvalume aluminum zinc coating GI basedcorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all specifiedas directed. |
| 13 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance places, cleats etc. conforming to Fe-410-W (Gde E-250) quality-B etc., complete all as specified and directed. |
| 14 | Taking down cement plaster on brick walls incl. raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed. |
| 15 | M & L for 15 mm thick cement plasteron fair faces of brick work or concrete surface on wall in CM 1:4finished fair and even, complete all as specified and directed. |
| 16 | Taking down chowkats or frames nexc. 1.5 Sqm each with shutters (W/o taking off shutters from the frame) and removal to store, complete all as specified and directed. |
| 17 | S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple, complete all as specified and directed. |
| 18 | S&Ffor 5mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m including Hacking out old broken glass (any thickness, size, quality or description) from steel frames or fixed with beads,complete all as specified and directed. |
| 19 | M & L for precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as inmanhole cover, shelves, chajjas etc andset in CM 1:6, complete all as specified and directed. |
| 20 | S&F of MS rolled section as in framed work as in doors or gates of angle or other section, complete all as specified and directed. |
| 21 | M&L for two coats of exterior emulsion paint (weather coatof Berger or equivelent ) over a coat of primer over a thin layer of external wall putty to achive a smooth finish surface overnewly plastered surface of wall, complete all as specified and as directed. |
| 22 | S&F of MS 1.60 mm thick MS plain black sheet in steel gates and similar work, cut to size, holes punched, including round headed screws and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded as required, complete all as specified and as directed. |
| 23 | S&F of standard aluminium section powder coated any colour as approved for door frames / shutters, window frames/shutters sliding/fixed and partitions etc including jointing cleat and rubber beading/linning, Pivot ,locking aragement and fixed in position with stainless steel screws, complete all as specified and as directed. |
| 24 | Supply and Fixing of sheet glass 5.5mm thick ordinary quality and glazing with oil putty or rubber and aluminium beading in squares n. exc 0.5 sqm in each pane, complete all as specified and as directed. |
| 25 | S&F of galvanised mild steel wire cloth 0.56 mm nomonal dia of bar and 1.18 mm avrage width of aperture ,fixed with tined tacks or galvanised wire staples, complete all as specified and as directed. |
| 26 | M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash, complete all as specified and directed for socket outlet 5 Amps on independent board. |
| 27 | M&L for Modular switch 1 way 6A, 1 module, flush button single pole, complete as specified and directed by Engineer in Charge. |
| 28 | M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 1.5 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1.5 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit) |
| 29 | Supply & fixing of 45W LED building security light fittingincluding provision of 25/32mm bore GI light grade pipe1.2 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole/ wall, complete allas specified and directed. |
| 30 | Supply and fixing erecting truly to vertical position steel tubular swaged pole complete with base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed (PCC, earth work shall be measured & paid separately under respective items). |
| 31 | Excavation in trenches exceeding 1.5 metre wide and not exceeding 3 metre in depth,for foundations,laying of pipes etc not exceeding 10sqm on plan for mamholes etc and not exceeding 3 metre in depth and getting out in hard/dense soil, complete all as specified and directed. |
| 32 | M & Laying of PCC 1:3:6, type C2, 40 mm graded aggregate for foundation fillings and mass conctere, complete all as specified and directed. |
| 33 | M & Laying for cement concrete for copying of poles B1 1:2:4, 20 mm graded crushed stone aggregate ,smooth finishing without using extra cement, complete all as specified and directed. |
| 34 | Material, labour jointing & testingXLPE insulated armoured heavy duty electric cable with standard aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core including making connection with suitable size of cable gland, aluminium lugs etc., complete including taking down old unserviceable cable, complete all as specified and directed. |
| 35 | Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes, complete all as specified and directed. |
| 36 | Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick, complete all as specified and directed. |
| 37 | Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning, complete all as specified and dierected. |
| 38 | Supplying, laying sub class \"B\" bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection, complete all as specified and directed. |
| 39 | Supply & fix hot press moulded SMC boxes with 200 Amps rating bus bar and distribution boardand single core PVC FRLS single core copper conductor 2.5 Sqmm in GI pipe 20mm dia for connection from junction box to street light complete , including MS clamps fabricated from 25 x 3 mm MS flat iron, nuts, bolts, etc for mounting all as specified and directed. Note :- MCBs, GI pipe, copper cable 2.5 Sqmm etc. required will be measured and paid under relevant items. |
| 40 | Supply & fixing of MCB\"s single pole 240 Volts 6 to 32 Amps 10 KA\"C\" series, all as specified and as directed. |
| 41 | S & F of GI water tubing 40 mm bore \"light grade\" galvanized,with all fittings like socket, union, elbow, bend, tees etc jointing and complete all as specified and as directed. |
| 42 | S & Fof LED Street Light 70 watt in new generation Energy Saving & Environment friendly light fitting which uses 36 No. high power LEDs as light source. Total LED lumens 9000 lm. Working lifetime of over 50000 burning Hours and it uses Active Power Factor Correction (APFC) electronic gear (electronic driver). Luminaire housing is of pressure die-cast alluminum alloy LM6 for housing (Heat Sink) for better heat transmission. It has IP65 protection. Operating Voltage range is from 100Volt to 265 Volt AC and Frequency range of 50 - 60 Hz. Fitting is suitable for an ambient temperature from -40 deg C to + 50 deg C and Humidity level of 10% to 90% RH complete. |
| 43 | Supply and fixing single core FR-LSH PVC flexible wire 1.5 Sqmm , 240 Volts for street lights including earth wire of 1.5 Sqmm. Two run of single core wire and one earth wire will be measured as one run meter. |