| 1 | DTR 11/0.4 KV BIS Level-III Conventional 100 KVA |
| 2 | 9 KV Gapless type ( 5KA) Polymer for DTR |
| 3 | 11 KV D.O. Fuse Unit Polymer type |
| 4 | Three phase Static Energy meters 20-80 Amps.with L.S. & TOD Facility with box |
| 5 | AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) |
| 6 | XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts |
| 7 | XLPE Cable 1 core unarmoured 150 sqmm Aluminium conductor 1100 Volts |
| 8 | M.S.Channel |
| 9 | 11 KV Strain hardware (T&C type) fittings |
| 10 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 11 | Back Clamp for H-Beam of MS Flat 65x8 mm (Each Weight 1.92 Kg) |
| 12 | AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) |
| 13 | H-Beam 152x152 mm, 37.1 kg /Mtr-13 mtr Long=482.3 kg |
| 14 | M.S. Angle 65x65x6mm |
| 15 | 11 KV AL 59 ACS Covered Conductor 78.82 SQ.mm Along with MVCC accessories as per EN;50397 Calculated for 1 KM Single Phase Feeder ,Tension/dead/anchoring clamps with piercing connector suitable for MVCC,IPC for CC to CC connection EN-50397 P-2 |
| 16 | LT XLPE AB CABLE 3x95+1x16+1x70 Sq.mm with Alluminium alloy insulated messenger wire |
| 17 | 11 KV AB Switch polymer type 400 AMP with Complete fitting |
| 18 | Transformer mounting Channel (100X50x6 mm.) |
| 19 | Danger Boards Enamelled 11 KV |
| 20 | Trans. Belting with 50 X 50 X 6 mm.angle with two cross fixing channels |
| 21 | D.O.Mounting Channel 75x40x6mm |
| 22 | 11 KV Pin Insulator Polymer Composite(5KN) |
| 23 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 24 | Bi-metallic clamps suitable for 12mm dia stud and 80sqmm AAAC |
| 25 | Bi-metallic clamps Distribution Transformers Bushing |
| 26 | Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) |
| 27 | Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor |
| 28 | Clamps for neutral for AB Cable |
| 29 | Back filling of poles with boulders. |
| 30 | G.I.Wire 4.0 MM. (8 SWG) |
| 31 | Aluminium Binding wire and tape |
| 32 | Piercing Connector Type-I For Single/three phase (Main 16-50 sqmm tap off 16-50 sqmm) |
| 33 | LT A.B. Cable tension Clamps (Galvanized) |
| 34 | LT A.B. Cable Suspension Clamps (Galvanized) |
| 35 | Piercing Connector Type-II For Single/three phase (Main 16-50 sqmm tap off 16-50 sqmm) |
| 36 | Earthing for PCC Pole 4.00 mm 8 SWG G.I.Wire-0.8 kg per pole |
| 37 | Single phase service connection box (Deep Drawn Metal Service Connection Boxes) With one incoming up to 25 mm2 and 8 no. out going up to 10 mm2 with insulated multiple outgoing connector- |
| 38 | Three phase service connection box (Deep Drawn Metal Service Connection Boxes) With one incoming up to 25 mm2 and 8 no. out going up to 10 mm2 with insulated multiple outgoing connector- |
| 39 | L.T. Distribution box with Isolator on Incoming with HRC fuse for 100 KVA DTR (300 Amp. Isolator & 6 no j type AI Hook |
| 40 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 41 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 42 | G.I.Pipe 40 mm Dia C grade type |
| 43 | EARTHING SET (40MM , 3 METER GI PIPE , GI WIRE, EARTHING CLMAP AND NUT BOLT) |
| 44 | Galvanized nut & bolt with washer |
| 45 | M.S.Nuts with Bolts |
| 46 | Stay set complete without Stay wire 16 mm. (Painted) |
| 47 | Stay Insulators 90X65mm |
| 48 | Red oxide paint |
| 49 | Aluminium paint |
| 50 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 51 | Complete jumpering of DTR |
| 52 | Concreting of structures & foundation (1:3:6) |
| 53 | DTR S/s fencing (31 feet) of 5\" barbet fencing on PCC support of 7No, 6\" Height |
| 54 | Double Gate (2No-2.5\"x5x) set of MS angle (25x25x4mm) with mesh & locking |
| 55 | G.I. STRIP 25X3 MM1 |
| 56 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 57 | Bentonite compound powder |
| 58 | Erection Cost |
| 59 | GST @ 18% on Total Material Amount and Erection Cost Please Enable Macros to View BoQ information |