| 1 | Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out in hard/dense of soil complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for foundation, laying of cables, footings up to proper level and laying of pipelines etc and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. |
| 4 | Removing surplus excavated material (soil) to a distance not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. |
| 5 | Formwork to sides of concrete foundations, footings, bases of columns, rafts, plinth beam and similar work;vertical or to batter complete all as specified and as directed. |
| 6 | M&L Formwork to chajjas and similar items including edges complete all as specified and directed. |
| 7 | M&L RCC M25 as in chajjas and in shelves and like complete all as specified and directed. |
| 8 | Formwork For Lintel and soffits of floor or roof beams, beam haunching incl supports, overhangs, etc also splays between floors and beams etc complete all as specified and directed. |
| 9 | M&L RCC M25 (20mm aggregate) For Foundations, including rafts, footings,foundation beams, plinth beams, bases for columns, lintel beams etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 10 | M&L for Anti-termite treatement of the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 11 | M & L mild steel TMT bar 10mm dia and over cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed. |
| 12 | M & L mild steel TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed. |
| 13 | M & L mild steel TMT bar 6mm dia and over upto 8mm diacut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed. |
| 14 | M&L Pre-cast PCC 1:3:6 type C1 (20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 of any description complete all as specified and directed. |
| 15 | M&L PCC 1:3:6 type C1 (40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 16 | M&L 75mm thick PCC type D-2 (1:4:8) using 40mm graded stoneaggregate as in sub base floor to floor, complete all as specified and directed. |
| 17 | M&L hard core broken stone of guage n exc 63mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 18 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or welded complete all as specified and directed |
| 19 | S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50 sqm in each pane complete all as specified and directed. |
| 20 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed |
| 21 | S&F 2nd class hardwood Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 22 | S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panels with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 23 | S&F Aluminium, anodised, barrel tower bolts 200mm long of extruded section complete all as specified and directed. |
| 24 | S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 25 | S&F Aluminium handles 200mm size, cast type, anodised complete all as specified and directed. |
| 26 | S&F overall length of cover plate 150mm long Floor door stopper of aluminium alloy body & tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 27 | S&F 100mm butt hinges stainless steel complete all as specified and directed. |
| 28 | M&L Preparation of new wooden surfaces over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 29 | M&L for 100 mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone agg) as in hard standingand similar works with , spike rolling ,or making impression of expanded metal, while the concrete is green complete all as specified and directed. |
| 30 | M&L for cement plaster rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surface as on wall finished even and smooth without using extra cement complete all as specified and directed. |
| 31 | M&L for cement plaster rendering 15mm thick on fair faces of brick/concrete surfaces with two coats i.e. (10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4) and mixed with WPC as per manufacturer instructions, finished even and smooth without using extra cement (WPC to be measured and paid separately) complete all as specified and directed. |
| 32 | Supply only Integral liquid waterproofing compound of approved make (ISI marked) complete all as specified and directed |
| 33 | M&L Preparation of newly plastered surfaces of walls and applying two coats cement base paint on walls over a coat of alkali resistant primer complete all as specified and directed. |
| 34 | M & L for preparation of new plastered surfaces of walls applying one coat of wall care putty and then applying two coats of premium oil bound distemper over one coat of primer as per manufacture instruction of required shade complete all as specified and directed. |
| 35 | Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, returning,filling in and ramming earth or broken rubble mixed with earth, in layers n exc 25 cm in hard/dense soil,watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. |
| 36 | S&F steel work in tublar truses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1998 grade St 240 complete all as specified and directed. |
| 37 | S & F mild steelplate (plain or chequered) channels, square cut or notched (ordinary or counter sunk), forming holes with riveted, bolted or welded attachement etc. and hanging also fastening and fixing complete conforming to Gde Fe 410 W (Gde E-250 Quality A) complete all as specified and directed. |
| 38 | S & F mild steelwork in framed brackets of angle or tees with web flanges cut to shape, flat irons, drilled and countersunk of screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc, 10 kg each bracket, and hanging also fastening and fixing complete conforming to Gde Fe 290, Gde E-165 complete all as specified and directed. |
| 39 | M&L for preparation of newsurfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 40 | M&L for preparation of new steel surfaces of any description, not exc 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat ofprimer complete all as specified and directed. |
| 41 | S & F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 42 | S & F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 43 | S&F for Plain, galvanised, mild steel sheeting of 0.8mm thickness, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 44 | Taking down and refixing precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment and included side kerb concrete, included removal and refixing and all as specified and directed . |
| 45 | M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade over sand cushion with grey cement and no pigment complete all as specified and directed. |
| 46 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 47 | M&L for Stone kerb of roughly squared stones of size 15cm x 30cm, dressed so that the maximum depression from a straight edge held againstthe dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush and all as specified and directed. |
| 48 | M&L Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed . |
| 49 | M&L Preparation of new plastered surfaces and applying three coats of white wash on walls complete all as specified and directed. |
| 50 | Demolition of cement concrete (unreinforced) of any description in ground floor not otherwise specifically provided for complete all as specified and directed. |
| 51 | M&L 75mm thick PCC type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base of floor, surface finished even and fair complete all as specified and directed |
| 52 | M&L 100 mm thick, Cement concrete 1:2:4,type B2 using 40 mm graded stone aggregate as in pavings, hardstandings and similar workcomplete all as specified and directed. |
| 53 | M&LChequered cement concrete tiles 30cm x 30cm x 25mm thick, set,laid with colour pigment jointed and pointed in neat cement slurry in floors as per IS 1237-1980 (Reaffaired in 2006) design astype (samples approved by Engr-in-Charge) over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 54 | M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment complete all as specified and directed. |
| 55 | M & L for Sand filling under floors or in foundations including watering and consolidation and all as specified and directed. |
| 56 | Material and labour for 25mm thick PCC (1:2:4) type B1 using 12.5mm graded stone agg as in levelling coarse under floor finished surface even and smooth with using extra cement all as specified & directed |
| 57 | M&L 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone agg) as in plinth protection finished even and fair without using extra cement floor shall be laid in alternate panels inluding necessary form work etc all as specified and directed. |
| 58 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed/surface in wall/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame, concealed in wall and 1.5 sq mm multi stranded copper conductor cable (FRLS) as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 59 | All as per item No. 58 here in before but for one light point/fan/bell point controlled by one wayswitch. |
| 60 | All as per item No. 58 here in before but for one switch socket outlet 3 pin 6 Amps on independent board |
| 61 | All as per Sl No. 58 above but Wiring with 4 Sqmm copper multistranded unsheathed cable (FRLS) and 4 Sqmm copper cable for earth continuity conductor controlled by one 16A switch socket independently complete all as specified and directed. |
| 62 | Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 63 | Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 64 | Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 65 | Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 66 | S & F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directedMake : Anchor/Havells/L&T |
| 67 | Supply and fix White cover plate with frame,2/3 module |
| 68 | Supply and fix White cover plate with frame,4 module |
| 69 | Supply and fix White cover plate with frame,8 module |
| 70 | Supply and fix White cover plate with frame,6 module |
| 71 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length complete all as specified and directed.Make:- Havells/ Polycab/ Plaza. |
| 72 | Supply and Fixing 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 73 | S&F factory madepowder coated distribution board VTPN, 6 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and directedMake : Indoasian/ Havells/ Legrand. |
| 74 | S&F distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 75 | Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, PVC body,1400 RPM, suitable hold fast with necessary nut, bolts / screws with louver ,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard. |
| 76 | Supply and Fixing 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 77 | Supply and fixing building security/ LED street light fitting 35/36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG |
| 78 | S & F MCB SPN 240 volts 32 to 40 Amps suitable for \"C\" curve, 10 KAcomplete all as specified and as directed. Make : Legrand/ L&T/ Indo Asian. |
| 79 | S & F MCB single pole 240 volts 6 to 32 Amps suitable for \"C\" curve, 10 KA complete all as specified and as directed. Make : Legrand/ L&T/ Indo Asian. |
| 80 | Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. |
| 81 | Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. |
| 82 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 83 | Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed. |
| 84 | Material and labour for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 85 | S&F distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 86 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installationcomplete all as specified and directed.Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 87 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 88 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 89 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 90 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 91 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 92 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 93 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 94 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 95 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 96 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 97 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 98 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 99 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 100 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 101 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 102 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 103 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 104 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 105 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 106 | M&L Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit,complete all as specified and directed. |
| 107 | S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. |
| 108 | Note :- An amount of Rs 1,050.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |