Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-12-2025 |
| Sl. No. | Item Description |
| 1 | M & L 25 mm thick PCC type B0 1:2:4 (using12.5 mm graded stone aggregate) asin leveling all as specified and directed. |
| 2 | S&F 75 mm size stainless steel butt hinges medium weight cold rolled. |
| 3 | M & L MS flat ironwork as in hold fast and similar small articles, cut to length, bent to shape, drilled hole and fixed with screw etc conforming to Fe-290 Gde-E-165 complete as specified and directed. |
| 4 | M&L PCC 1:3:6, C-1 (using 20 mm graded stone aggregate) as in bed blocks for inserting holdfast/ filling of steel frame, etc including necessary form work complete as specified and directed. |
| 5 | S&F powder coated aluminium anodised frame for doors, windowsetc with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 6 | S&F Anodised aluminium powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including all necessary fittings like hinges joining cleats, glazing clips,moving roller, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 7 | S & F as in repairs Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 8 | S & F in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.88mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 9 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with puttty or fixed with beads, |
| 10 | S & F for 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises as directed. |
| 12 | M&L Non skid ceramic tiles 7 to 8mm thickarea of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm 7mm thick coloured tiles in floors etc., set and jointed in neatcement slurry and pointed in white or coloured cement to match, over screed bedding 15mm thick in CM 1:4as specified and as directed. |
| 13 | Material & Labour for Brick work with sub class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) complete all as specified. |
| 14 | M&L for half thickbrick work with sub class \"B\" bricks straight or curved on plan exceeding 6m mean radius with old size bricks locaaly available built in cement mortar 1:4 complete. |
| 15 | M&L 15 mm thick cement plaster in CM (1:4) on wall( with approved water proofing compound) on fair faces of brick work incl finished even and smooth without using extra cement.Note: 1. WPC @ 2% of cement, will be paid separately.2. The rate quoted by contractor is deemed to be included necessary scaffolding and formwork as required upto 7.00 Mtr height building. |
| 16 | M&L 5 mm thick cement plaster in CM (1:3) on ceiling surfaces incl finished the surface even and smooth without using extra cement. |
| 17 | Supply only Integral water proofing compound |
| 18 | M&L for Preparation of new plastered surfaces andapplying three coat of white wash on ceiling complete all as specified. |
| 19 | Refixing 15mm old steel tubing and connection in new or old position (wall, ceiling, floors, etc.) |
| 20 | Refixing 20mm old steel tubing and connection in new or old position (wall, ceiling, floors, etc.) |
| 21 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing and making good , cutting not exc 10cm girth complete all as directed. |
| 22 | S & F in repairs, stop valves, 15 mm bore cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions as specified and directed. |
| 23 | S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges all as specified and as directed. |
| 24 | S& F as repairs brass chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union 125 mm size complete all as specified and directed. |
| 25 | S & Fin repairs, vitreous China squatting pan, \"Orissa\"pattern, size 580mm x 440 mm, white with integral foot rest and \"P\" or \"S\" trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications as specified. |
| 26 | S&F in repair for Vitreous China urinals,half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing grating and Union for discharge pipe incl CP 40mm waste coupling and PVC 40mmwaste pipe 900mm long . |
| 27 | S&F in repair Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) |
| 28 | M& L for PVC (SWR) floor trap 100 dia, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified. |
| 29 | M&L for special treatment for sunken portion of WCs/Bath & toilet executed in following stage:- Stage1:-Demolition of wc including lime concrete and cemennt concrete etc and preparing of surfaces of existing sunken portion of wc`s or bath etc with wire brush to removed all loose dirts, oil grease etc including removing debries from site of work etc.Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantityall as per manufacturere`s instructions.Stage 3:- Apply Dr. Fixit Premeseal primer or equivelent of STP Ltd (and allow to dry for 8 hrs) all as per manufacturer`s instructions.Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 micron or shilicry 215 of STP (The surfaces after painting one coats shall be allowed to dry for 6 hrs before next coats) Stage 5:-Rendering 10mm thick in CM 1:3 mixed with integral water proofing chemical of Dr Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantityall as per manufacturere`s instructions. Stage 6:-All CI joints shall be filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr. Fixit pidicrete URP all as per manufacturer`s instructions.Stage 7:- Making holes in walls and fixing 600mm long 40mm dia medium grade GI spouts for draining of excess water if any. Stage 8:-Carryout ponding testfor 48 hrs to ensure water tighteness of repaired sunken portion and filling of sunken portion for cement concrete Type E2, 1:5:10 using 40mm graded stone aggregate as in lean concrete complete all as specified and directed. Note:- only plan area shall be measured for payment under this items. (b)Depth of suken portion of WC`s/ bath shall be upto 35 CM which is to be taken into account while coating the rate against this item.(c)The rate shall be quoted by contractor shall be deemed to be included for all the horizontal and verticl treated surface of sunken portion of WC`s/baths. |
| 30 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints laid in trenches or in floors complete all as specified including dismantling of PCC & taking out old unserviceable 110mm bore PVC pipe with fittings & making good disturbed area complete all as specified & directed. |
| 31 | S &F for PVC (SWR) pipes single soketed, in any length with rubber ring joints, fixed to walls, 75mm bore pipes complete all as specified and directed. |
| 32 | S & F for PVC (SWR) bends any radius with access door, 110mm bore complete all as specified and directed. |
| 33 | S & F for PVC (SWR) bends any radius, 75mm bore complete all as specified and directed. |
| 34 | S & F for PVC (SWR) bends any radius with access door, 75mm bore complete all as specified and directed. |
| 35 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed. |
| 36 | Taking down chowkhats or frames with shutter (without taking off shutter from the frame) n. exe 1.50 sqm in each complete all as specified & directed. |
| 37 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawin |
| 38 | S & F Factory made solid panel PVC door shutter30 mm thick (style) consisting of framemade out of M.S. tubes for top & bottomrails. M.S. frame shall be covered with heatmoulded plain colour PVC ‘C’ channelhaving a PVC sheet strip of 20mm widthstuck inside with solvent cement for stilesand plain colour PVC sheets for top rail,lock rail & bottom rail on either side & asgap insert for top rail & bottom rail; but wire gauzedi.e. panel will be of wire gauze in lieu ofPVC sheet panel. The wire gauze shallbe wrapped on an additional square8mm M.S. Solid tube and this tube shallbe welded to M.S. tubes. The wire gaugeshall be stretched to tighten firmly as per specification & drawing., Section -8, clause 8.24(a). |
| 39 | Taking down chowkhats or frames with shutter (without taking off shutter from the frame)exe 1.50but n. exc. 4sqm in each complete all as specified & directed. |
| 40 | S&F Pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and as directed. |
| 41 | S&F 35 mm thick, 2nd class hardwood plain, Flush shutters,solid core construction, with blockboard core and plywoodface panels, commercialtype on both sides complete as specified and directed. |
| 42 | S&F Powder coating anodised aluminium window and ventilator shutters, side hung type without sash,aluminium sectiion weighihg 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber e packing, anodised handles 2 nos in each door, hinges, anodised aluminium snap beading screws etc, complete all as specified. |
| 43 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge |
| 44 | S&F4 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sq.m. each pane . |
| 45 | S&F 100 mm size, butt hinges, extruded medium weight cold rolled mild steeletc complete. |
| 46 | M&L 150 mm long aluminium anodised, barrel tower bolts of extruded section etc complete. |
| 47 | S&F 150mm size, aluminium anodised handle,fabricated type. |
| 48 | S&F Mild steel sliding door bolts,250mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed |
| 49 | S & Fstainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples. |
| 50 | M&L 15 mm thick, screed bed or bedding layer of cement mortar 1:4,for laying floor finishes as directed. |
| 51 | M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles all as specified and directed. |
| 52 | M&L rendering 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces as in vertical surfaces for laying tiles as directed. |
| 53 | M&L Glazed ceramic tiles in vertical surface 350x 400x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchwith the shade of tiles all as specified and directed. |
| 54 | M&L for Machine cut kota stone slab flooring 20-25mm thick over 15 mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 55 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick screed bed in CM 1:4 and with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 56 | Dismantling water tanks and removing to store Exc 500 & n.exc 1000 Ltrs |
| 57 | S&F Rotational moulded polyethylene water storage tanks 1000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 58 | S&F 15mm bore ball brass valves high pressure, with polythene float & fly nuts complete, screwed for iron pipe or brass ferrulecomplete all as specified and directed. |
| 59 | S&F 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 60 | S&F in repairs Vitreous china wash basin, white flat back, size 550mm x 400mm with brackets, excluding pillars cock 15mm bore CP, PVC connection of 450mm long including PVC (HDPE) 32mm bore waste pipe, brass couplings 32mm CP etc complete all as specified and directed. |
| 61 | S&F 15mm bore Brass CP basin mixer for mixing hot & cold water screwed down for iron pipe and fixed |
| 62 | S&F in repairs 600 x 450mm beveled edged mirror or selected quality glass mounted on 6mm thick AC building board or commercisl plywood and fixed to wooden plugs with chromium plated brass screws and cup and washers. |
| 63 | S&F in repairs, stop valves, 15mm bore cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed bhoth ends for iron pipe or for unions as specified and directed. |
| 64 | S&F in repairs 15mm bore PVC connection pipe 450mm longh with PTMT nuts at both ends. |
| 65 | S&F in repairs, 10 Litres capacity PVC valveless syphonic action type, flushing cistern (ISI marked), low level with inlet. Ball valve, float bracket & flush pipe complete all as specified& directed. |
| 66 | S&F in repairs 15mm bore Bib Taps, Chromium plated cast copper alloy with crutch or butterfly handle, screwex for iron pipeor for brass ferrule and fixed. |
| 67 | Demolition and breakingup 100mm bore drain pipes (Saltglazed ware, AC orReinforced concrete) setincement mortar |
| 68 | S&F 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete as specified and directed. |
| 69 | S&F 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, laid in trenches complete as specified and directed. |
| 70 | S&F PVC (SWR) pipes single sockets, in any length with rubber ring joints, laid in ground or floors 75mm dia complete as specified anjd directed. |
| 71 | S&F 110mm bore PVC (SWR) bends of any radius complete as specified and directed. |
| 72 | S&F in repairs, PVC (SWR) junction, single T equal or unequal 110mm bore. |
| 73 | S&F in repairs, PVC (SWR) 75 mm dia, floor trap ,plain with grating including jointing to waste pipe with solvent cement and fixing in PCC 1:2:4. |
| 74 | S&F in repairs, 110mm bore PVC (SWR) vent cowl. |
| 75 | S&F in repairs Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern omplete all as specified and as directed. |
| 76 | S&F in repairs 32mm diaWaste coupling of PTMT (half or full threaded) (Minimum weight 32mm45gms/40mm-60 gms) complete all as specified and directed. |
| 77 | Demolition of brick work or stone/boulder masonry, built in cement morter including all quoins, arches, pillars etc complete all as specified and as directed |
| 78 | Taking down cement plaster on brick or stone or concrete surfaces of wall etc ,icluding raking out joints , hacking for key, scrubbing down with wateretc. |
| 79 | M&L for rendering 10mm thick on fair face of brick worksor concretesurfaces of wallswith CM (1:4) anf finished even and smoothwithout using extra cement. |
| 80 | M&L for rendering 15mm thick on other than fair face of brick worksor concretesurfaces of wallswith CM (1:6) and finished even and smoothwithout using extra cement. |
| 81 | Taking up or down 15 mm bore steel tubing and connections, including removal to store complete all as specified and directed. |
| 82 | S&F steel tubes, galvanised 15 mm bore, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete as specified and directed including taking down old one. |
| 83 | Taking up or down 20 mm bore steel tubing and connections, including removal to store complete all as specified and directed. |
| 84 | S&Fsteel tubes, galvanised 20 mm bore, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete as specified and directed . |
| 85 | S&F for Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms |
| 86 | S&F for Grating doom 100mm dia of PTMT (Minimum weight 25gms) |
| 87 | S&F for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) |
| 88 | S&F in repairs, Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) |
| 89 | Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15cm thickness (below or above ground level) |
| 90 | M & L PCC 1:3:6 type C-2 (75 mm) thick ( 40mm graded aggregate) thick as in plinth protection/Hard standing , etc finishing cement concrete surface even & fair whthout using extra cementmaking joints with bitumastic filling in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 91 | M&L for broken stone bolder as hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surfaceas specified and as directed. |
| 92 | M&L 75 mm THICK , plain cement concrete 1:4:8, type D-2 (ussing 40mm graded stone aggregate ) as in sub base of flooring etc all as specified as direected. |
| 93 | Sand filling under floors ,foundations including watering and consolidation all as specified and directed. |
| 94 | M&L For Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade for light traffic all as specified and directed. |
| 95 | M&L for Providing, cement concrete 1:2:4 type B0 (12.5 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges o, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 96 | M&L for preparing the new plastered surfaces and applying two coats ofcement base paint over a coat of wash white on wallsall as specified and direcrted. |
| 97 | M&L for preparation of new plastered surfaces of wall and applying three coats of white wash etc complete all as specified and directed by Engr-in-charge. |
| 98 | S & F for rolled mild steel work in roof trusses (framed), trussed, purlins crane gantries , rafts and fastening and heavy brackets framming (beams tee,angle channel and or flat sections) including distance pieces, cleat nut bolts etc quality confirmingto Fe-290 (Gde E-165)as specified and as directed. |
| 99 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. |
| 100 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roofcoverings roof coverings. |
| 101 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws asspecified. |
| 102 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ as in ridge, fixed with ixed with selftapping screws asspecified. |
| 103 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying twocoatsof synthetic enamel paint over acoat of red oxide primer complete all as specified and directed by Engr-in- charge. |
| 104 | Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,sunken type box etc.and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed by Engr-in-Charge. |
| 105 | Taking down carefully MCB DBs any type and size by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. |
| 106 | Taking down carefully old/unsv lights of any type any type and size by unscrewing from wall fixtures and fittingfor taking credit including complete fitting and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. |
| 107 | Material and labour for point wiring for the followings with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and includingPVC casing caping including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of 1.2mm thickness with plastic laminated white top sheet cover 3mm thick.(Note:-(1) Rate forCutting, chieseling and making good the existingsurface for complete concealed wiring is deemed to be included in quoted rate) all as specified & directed by Engr-in-Charge as below :-(a)One light/fan point controlled by one,one way switch. |
| 108 | All as per item No 110 here-in-before butOne 3 Pin 5 Amps socket out let point onindependentboard. |
| 109 | All as per item No 110 here-in-before butOne 3 Pin 5 Amps socket out let point on same board alongwith other suitable switchs. |
| 110 | All as per item No 110 here-in-before but using 4 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board complete all as specified/directed. |
| 111 | Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, one way complete all as specifed/directed. |
| 112 | Supply and fixing of switch socket combination 3/5 Pin, 2 in 1, 5 Amps, 240 volts flush type (non shuttered) complete all as specified/ directed. |
| 113 | Supply & fixing of socket outlet 2 in 1, 3/5 pin 5 Amps, 240 Volts,flush type (non shuttered) complete all as specified / directed. |
| 114 | Supply and fixingof switch socket combination multipurpose 3/5 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) complete all as specified/directed. |
| 115 | Supply and fixing angular/batten holderPVC/Polycarbonate suitable for batten fittings including one LED Lamp of inverter type min 4hr backup9W of Havells/Philips/Cromton Make, complete all as specified/directed. |
| 116 | Supply and fixing ofceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified/directed. |
| 117 | Supply and fixing motion sensor LED fitting 1x20 watts,interver batten holder with 2000 lumen 220volts AC decorative box type with driver with aluminium housing,LED tube light conncting up to 3 core flexible copper conductor cable of suitable size from ceiling rose complete as specified/directed. |
| 118 | S&F LED Bldg light fitting 35W 230 volts AC outdoor tye with high pressure die cst aluminium hostng and heat resistant complete with driver, lamp baacket with impact and corrosin resistant including thermal management in multiple optics complete wth IP 65/66 protection complete as specified/directed. |
| 119 | Supply and fixing in repair of MCB Distribution board SPN 8 Way for mountingSPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed by Engr-in-charge. |
| 120 | Supply & fixing in repair of MCB DP 32 Amps\"C\" Series 10 KA 240 volts complete all as specified/directed. |
| 121 | Supply & fixing in repair of MCB SP 6-32 Amps\"C\" Series 10 KA, 240 volts complete all as specified/directed. |
| 122 | Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised wire of dia 4 mm as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and eath works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed.Note:No extra payment will be for the earthing GI wire of size 4 mm dia all complete as specified and as directed. |
| 123 | Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including PVC conduit of adequate size fixed on surface of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 6 Sqmm as earth wire (green in colour) run through PVC casing capingand connected common earth dolly including taking out the old sub main wiringfor connection to DBs/dolly shall be deemed to be included in this item and Two runs of 6 Sq mm as current carrying conductor and one run of6 Sq mm as earth conductor PVC conduit shall be measured as one run for measurement, complete all as specified and directed. |
| 124 | Taking down and Supply and laying and testing cable, XLPE insulated,screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm. With 2 core all complete as specified/directed. |
| 125 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed. |
| 126 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 127 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 128 | M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. |
| 129 | S&F LT cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. |
| 130 | Supply & fixing of Tubes, \"light grade\" galvanised 50mm bore, with all fitting and fixed complete to walls and ceilings or laid in floors to run cables through them for its protection including all the accessories required, complete as directed /specififed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail