| Sl. No. | Item Description |
| 1 | M&L for taking down defective centrifugal pump set 100 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at same location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :-(a)The spares shall be measured and paid seperately in the relevent items given below.(b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. Thecontactor is responsible for making alternate arrangement of pump set in case of time required more than one week.(d)In case services affected due to delay in repair of pump set, a penalty @ Rs 1000 per day will be levied from the contactor.(e)Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. |
| 2 | Supply only Ball bearing suitable for 100 HP capacity motor pump as per manufacturer\"s design complete all as specified and as directed.Make : Tata/SKF/NBC |
| 3 | Supply only split casing gaskets suitable for 100 HP capacity motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 4 | Supply only coupling Rubber Bush suitable for 100 HP capacity motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 5 | Supply only shaft sleeves suitable for 100 HP capacity motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 6 | Supply only water seal suitable for 100 HP capacity motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 7 | Supply only coupling bolt with nuts suitable for 100 HP capacity motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 8 | Supply only Air cock grease nipple suitable for 100 HP capacity motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 9 | Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 100 HP capacity motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 10 | Supply only bronze impeller suitable for 100 HPcapacity motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 11 | M&Lfor suitable size of gland packing for 100 HP pump set as per manufacturer\"s design complete all as specified and as directed. |
| 12 | M&L for rewinding ofsquirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 100HPmotor capacity. |
| 13 | M & L for servicing of starter by checking and servicing the contactor coil , over load relay coiland any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drillingtesting the panel complete all as specified and directedfor the100 HP capacity pump setsNotes :-(i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be include in quoted rate. |
| 14 | Supply & fix in replacement of 3 Pole power contactor AC 415 V 160 Amps ,AC3 ( inductive load ) type with Aux contact 2 NO + 2 NC50 Hz Model No. as per existing framesuitable for 100 HP Pump sets complete all as specified and as directed.Make : L & T / Indo Asian /Schneider |
| 15 | Supply & fix in replacement adjustable CT/Direct operated thermal over load relay 105 to 156 A for 100 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed.Make : L & T / Indo Asian /Schneider |
| 16 | M&L Taking down defective centrifugal pump set 40 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after).Note :-(a)The spares shall be measured and paid seperately in the relevent items given below.(b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. TheContractor is responsible for making alternate arrangement of pump set in case of time required is more than one week.(d)In case of services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor.(e)Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. |
| 17 | Supply only Ball bearing suitable for 40 HP motor pump as per manufacturer\"s design complete all as specified and as directed.Make : Tata/SKF/NBC |
| 18 | Supply only coupling Rubber Bush suitable for 40 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 19 | Supply only coupling bolt with nuts suitable for 40 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 20 | Supply only shaft sleeves suitable for 40 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 21 | Supply only split casing gaskets suitable for 40 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 22 | Supply only Air cock grease nipple suitable for 40 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 23 | Supply only water seal suitable for 40HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 24 | Supply only bronze impeller suitable for 40HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 25 | Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 40HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 26 | M&L for rewinding ofsquirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 40 HPmotor capacity. |
| 27 | M&Lfor suitable size of gland packing for 40 HP pump set as per manufacturer\"s design complete all as specified and as directed. |
| 28 | Taking down and relaying of existingDI water pipe lines of size 300 mm bore but of any type including all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 29 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 300 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 30 | Supply and fixing in replacement Sluice valve of size 300 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheelfixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 31 | Material & Labour as in repair for Construction ofValve chamber having inner dimensions 1200 mm x 1200 mm x 1200 mm with foundation in PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B bricks old size built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- Chamber cover shall be measured and paid seperately under relevant item of this schedule. |
| 32 | Material and Labour for dismantling the brassspindle from 300mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed. |
| 33 | Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size 300mm dia, by dewatering the leakage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending, grinding, ncluding all accessories such as tee, elbow, collar etc and ensure no leakage with pressure test complete all as specified and directed. Note : Pipes and mechanical collar and Excavation and earth work shall be measured and paid seperately |
| 34 | M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of size as per IS complete with mechanical/detachable type arrangement as per site requirementwith MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 300 mm borecomplete all as specified and as directed. |
| 35 | Taking down and relaying of existingDI water pipe lines of size 200 mm bore but of any type including all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 36 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 200 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 37 | Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size 200mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding, includingall accessories such as tee, elbow, collar etcand ensure no leakage with pressure test complete all as specified and directed. Note : Pipes and mechanical collar and Excavation and earth work shall be measured and paid seperately |
| 38 | M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of size as per IS complete with mechanical/detachable type arrangement as per site requirementwith MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 200 mm borecomplete all as specified and as directed. |
| 39 | Taking down and relaying of existingDI water pipe lines of size 150 mm bore but of any type includings all fittings after removal of scalling, cleaning and flushing etc complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 40 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 41 | Supply and fixing in replacement Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 42 | Material & Labour as in repair for Construction ofValve chamber having inner dimensions 900 mm x 900mm x 900 mm with foundation of PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B old size bricks/ built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick renderingin CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule. |
| 43 | Material and Labour for gland packing in leaking Sluice Valve of 150 mm dia Complete including replacing/tightening the existing bolts and nuts etc. complete all as specified and as directed. |
| 44 | Material and Labour for dismantling the brassspindle from 150mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed. |
| 45 | Supply and fixing in replacement Non return valve (NRV) of size 150 mm (ISI marked), gun metal body suitable for 150 mm dia pipe line complete all specified and directed |
| 46 | Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size 150mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee, elbow, collar etcand ensure no leakage with pressure test complete all as specified and directed. Note : Pipes and mechanical collar and Excavation and earth work shall be measured and paid seperately |
| 47 | M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of size as per IS complete with mechanical/detachable type arrangement as per site requirementwith MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 150 mm borecomplete all as specified and as directed. |
| 48 | Taking down and relaying of existingDI water pipe lines of size 100/80 mm bore but of any type includings all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 49 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 100 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 50 | Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed |
| 51 | Material and Labour for gland packing in leaking Sluice Valve of 100 mm dia Complete including replacing/tightening the existing bolts and nuts etc. complete all as specified and directed |
| 52 | Material and Labour for dismantling the brass spindle from 100mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed. |
| 53 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 80 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 54 | Supply and fixing in replacement Sluice valve of size 80mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 55 | Material & Labour as in repair for Construction ofValve chamber having inner dimensions 600 mm x 600mm x 600 mm with foundation of PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B old size bricks/ built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick renderingin CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule. |
| 56 | Material and Labour for dismantling the brass spindle from 80mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed. |
| 57 | Material and Labour for gland packing in leaking Sluice Valve of 80 mm dia Complete including replacing/tightening the existing bolts and nuts etc. complete all as specified and directed. |
| 58 | Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size 80/100mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee, elbow, collar etcand ensure no leakage with pressure test complete all as specified and directed. Note : Pipes and mechanical collar and Excavation and earth work shall be measured and paid seperately |
| 59 | M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of size as per IS complete with mechanical/detachable type arrangement as per site requirementwith MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 80/100 mm borecomplete all as specified and as directed. |
| 60 | Note :-(a) In case laying of CI/GI/DI pipe line is to be executed in civil area, it will be the responsibility of the contractor to obtain necessary permission for cutting of road & berm from BWSSB/ state Govt agency. |
| 61 | (b) For this purpose amount to be paid online to BWSSB, same is deemed to be included in unit quoted rate. |
| 62 | (c) The T&P like JCB, Drill Machine, Moveable Generator etc required for cutting of road shall be arranged by the contractor & no extra cost shall be paid for the same. |
| 63 | (d) After execution of work, the contractor will make good disturbed portion of road with bitumen or PCC complete as directed by Engineer-in-Charge. Cost of the same is deemed to be included in unit quoted rate. |
| 64 | M & L for DI specials and fittings as per IS for spigot and socketed pipes or flanged pipe for water mains I branches lines such as bends(any type radious and angle ) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pices,single branch,Y juntion, double branch, cross, including connecting pieces one end flanged and other socket or spigot and bell mouth pices suitable for rubber joint,tyton joint up to 300 mm bore and conforming to IS-9523: 2000 complete all as specified and directed. |
| 65 | Material and labour for Making arrangement to flush out the existing pipe line of any type 160 to 200 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed. |
| 66 | Material and labour for Making arrangement to flush out the existing pipe line of any type 110 to 150 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed. |
| 67 | Note for item 65 & 66 :-(i)The Contractor is deemed toarrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This shall be inclusive in quoted rate. (ii)Excavation and earth work required shall be measured and paid seperately. (iii)The flushing out shall be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This shall be inclusive in quoted rate. |
| 68 | S&F in replacementfoot valve cast iron of size 50 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed. |
| 69 | Material and labour for Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materialsfrom the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on plastered surfaces and one coat of synthetic enamelpaint on steel surfaces complete to make it operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers shall be given as per requirement by the Engineer-in-Charge. |
| 70 | Material and labourfor Fabricate valve chamber coversmade out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted cover complete all as specified and directed. |
| 71 | Material and labour for Painting with two coats of synthetic enamel paint over coat of zink chrome on steel surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed. |
| 72 | Material and labourfor Attending day to day water supply service related complaintslike choking of rising main pipes of buildings, blockage in control valves/ float valves/ pipe fittings, etc, applying necessaryengineering efforts like dismantle of pipes and fittings to clean and remove blocking objects, descaling of pipes, re-fixing of pipes on wall, etc to restore the proper flow of water to service tanks all as specified and directed. |
| 73 | Note :- (a) The contractor has to attend above mentioned job in any location of AFTC, 2 DC and entire AFS jalahalli East and West area |
| 74 | (b)The service tanks are positioned on roof top of multi storied buildings upto three storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc. |
| 75 | (c) The cost of rethreading of GI pipes of 25mm dia and adding of new GI nipple of suitable length after rethreading is deemed to be included in the quoted rate. |
| 76 | (d) Due to shortage of water in the station, the repair work and testing required under this item need to be carried out during water supply distribution hours i.e. 5:30 AM to 7:30 AM. Nothing extra shall be permitted in this regard. |
| 77 | (e) The cost of repair to the damages of cemented surfaces/ external finishes/ metal clamps of rising pipes are also deemed to be included in the quoted rate. |
| 78 | (f)In case of any delay in attending the complaint more than 6 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. |
| 79 | (g)If the delay is more then 06 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. |
| 80 | (h) The decision of the Accepting Officer in this regard shall be final and binding. |
| 81 | Supply and fixingin repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 82 | Supply and fixingin repair Chlorinated PVC Gate Valve of size 25 mm dia, ISI marked complete all as specified and as directed. |
| 83 | Supply and fixingin repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 84 | Supply and fixingin repair Chlorinated PVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed. |
| 85 | Supply and fix of PVC water tank 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed |
| 86 | Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20 mm complete all as specified and directed |
| 87 | Supply and fix Nipple suitable for HDPE water tankof size 20 mm complete all as specified and as directed. |
| 88 | Supply and fix in repairs lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire suitable up to 1000Ltrs cap of tanks complete all as specified and directed by Engineer-in Charge |
| 89 | S & F in replacement Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe fixed of size 15 mmfor brass ferrule fancy type and fixed complete all as specified and directed. |
| 90 | Cleaning of service tanks of the capacity as mentioned below on roof top of bldgs upto three storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properlyinside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such as\"TANK CLEANED ON\"--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed.Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours early in the morning or late in evening.(ii) Contractor shall maintain a pucca bound register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted alongwith RAR.(iii)Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same.(iv)All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept. |
| 91 | (a)For RCC /PVC tank exceeding 200 liters and not exceeding 500 ltrs |
| 92 | (b)For RCC /PVC tank exceeding 501 liters and not exceeding 1000 ltrs |
| 93 | (c)For RCC /PVC tank exceeding 1001 liters and not exceeding 2000 ltrs |
| 94 | (d)For RCC /PVC tank exceeding 2001 liters and not exceeding 5000 ltrs |
| 95 | (e)For RCC /PVC tank exceeding 5001 liters and not exceeding 25000 ltrs |
| 96 | Supply and fix of PVC water tank 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed |
| 97 | Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 25 mm complete all as specified and directed |
| 98 | Supply and fix Nipple suitable for HDPE water tankof size 40 mm complete all as specified and as directed. |
| 99 | Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all as specified for tanks ofcapacity 200 to 500 Ltrs. |
| 100 | Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all as specified for tanks of capacity 501-1000 Ltrs. |
| 101 | Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all as specified for tanks of capacity 1001-2000 Ltrs. |
| 102 | Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all as specified for tanks of capacity 2001-5000 Ltrs. |
| 103 | Supply and fix of PVC water tank 2000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed |
| 104 | Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 40mm complete all as specified and directed |
| 105 | Supply and fix Nipple suitable for HDPE water tankof size 25 mm complete all as specified and as directed. |
| 106 | Supply and fix in repairs lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire suitable for1001 to 5000 Ltrs cap of tanks complete all as specified and directed by Engineer-in Charge |
| 107 | Supply and fixingFramed brackets/staging to OH Tank of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, hinges and handles etc. n exc 10 kg each brackets, conforming to Fe.290. Gde-E-165 complete all as specified and as directed. |
| 108 | Material and labourfor Painting with one coat of synthetic enamel paint on old steel surfaces of any description, over 10cm in width or girth, not otherwise described including preparation of old surfaces complete all as specified and directed. |
| 109 | Supply ,Install, testing and commissioning in replacement of Smart control panel for dosing system with 3phase input supply and output capacity of minimum 6A and upgradable to 16A, Equipped with 20x4 Character LCD to display real time phase wise voltage. 5 mm LED Indication for fault detection including Under Voltage (380 Vac), Over load (440 Vac), Phase failure, Over Load. Weather proof IP54 enclosure indoor type complete all as specified and directed. |
| 110 | Chemical and physical analysis of water confirming to IS3025 - 58 (2006) second revision of various locations atAFS Jalahalli from any lab authorised by central/state govt for chemical analysis.The following test shall be carried out :-(a) Bacteriological Quality of water (ref Table 6, Clause 4.1.1, IS 105000 : 2012 second revision)(b) General Parameters Concerning Substances of water (ref Table 2, Clause 4.0, IS 10500 : 2012 second revision)(c) Organoleptic and Physical Parameters of water (ref Table 1, Clause 4.0, IS 10500 : 2012 second revision)Note : Contractor shall collect the water samples and submit the test results to Engr-in-Charge all as specified and directed. |
| 111 | Material and labour for removing the submersible pump set of capacity up to 15 HP including pipes and submersible cables complete from the exisiting bore well of depth up to 200 mtr by any suitable method i.e either manual vehicle mounted motorized system and disconnecting the pump motor to locate the faults in presence of Engr-in-Charge, transporting to Wksp and carry out repairs, reassembling, lowering to bore well after repairs, testing and commissioning complete all as specified and directed |
| 112 | Taking down defective open well submersible pump set 5 HP 7.5 HP toby disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a)The spares shall be measured and paid seperately in the relevent items given below.(b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. TheContractor is responsible for making alternate arrangement of pump set in case of time required more than one week.(d)In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor.(e)Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. |
| 113 | Supply only Ball bearing suitable for 5 HP 7.5 HPmotor pump as per manufacturer\"s design complete all as specified and as directed.Make : Tata/SKF/NBC |
| 114 | Supply only split casing gaskets suitable for 5 HP 7.5 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 115 | Supply only shaft sleeves suitable for 5 HP 7.5 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 116 | Supply only water seal suitable for 5 HP 7.5 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 117 | Supply only bronze impeller suitable for 5 HP 7.5 HP motor pump as per manufacturer\"s design complete all as specified and as directed. |
| 118 | Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 5 HP 7.5 HPmotor pump as per manufacturer\"s design complete all as specified and as directed. |
| 119 | M&L for rewinding ofopen well submersible electrical motor, 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 5 HP to 7.5 HPmotor capacity. |
| 120 | M&L flat three core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 6 .0 Sq mm nominal area including taking out old unserviceable cable complete all as specified and directed. Make :- Havells/Polycab/Finolex |
| 121 | Supply & Fix as in replacement GI tubing medium grade of size 80 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 122 | Taking down and relaying of existingserviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of size 40 to 50 mm bore complete all as specified and directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 123 | Supply & Fix as in replacement of GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 124 | S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm complete all as specified and directed. |
| 125 | Supply & Fix as in replacement of GI tubing medium grade of size 40 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 126 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm complete all as specified and directed |
| 127 | Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of size 25 mm bore complete all as specified and directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 128 | Supply & Fix as in replacement of GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 129 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed. |
| 130 | Taking down and relaying of existingserviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of size 20 mm bore complete all as specified and directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 131 | Supply & Fix as in replacement of GI tubing medium grade of size 20 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 132 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and directed. |
| 133 | Taking down and relaying of existingserviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site 15 mm bore complete all as specified and directed. |
| 134 | Supply & Fix as in replacement of GI tubing medium grade of size 15 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 135 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm complete all as specified and directed. |
| 136 | Material and labour for Making arrangement to flush out the existing pipe line of any type 63 to 100 mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing on completion all as specified and directed. |
| 137 | Material and labour for Making arrangement to flush out the existing pipe line of any type upto 50 mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing on completion all as specified and directed. |
| 138 | Note for item 136 & 137 :-(i)The Contractor is deemed toarrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This shall be inclusive in quoted rate. (ii)Excavation and earth work required shall be measured and paid seperately. (iii)The flushing out shall be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This shall be inclusive in quoted rate. |
| 139 | Supply and fix of PVC water tank 5000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed |
| 140 | Taking out silt, liquid water sludge in solid/semi solid state / pumping out all mud sewage water from collection sump of size 5 mtr dia and 4 mtrs depth /Manholes STP tanks of any capacity and size and removing the same using truck mounted honey sucker of capacity minimum 4 cum and to dispose off the sludgein low lying area at any distance during Sunday and holiday as per requirement, depositing the sludge in low laying area with covering by earth over it and leaving the collection sump clean etc. complete all as specified and directed. |
| 141 | Note for item No 140 :-The tenderer shall take into consideration for following points while quoting his rate for this item andthe unit rate is deemed to be included for :-(i) Cuttingand filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground leve around collection sump. Useful material shall be stacked. |
| 142 | (ii) De-watering by high presure submersible pump complete. |
| 143 | (iii)Removal of sludge & sand from inside the tank scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus, deposited stains using wire brush filling of cavities inside of tank with CM 1:2 mortar. |
| 144 | (iv) cleaning of walls , flooring and ceiling with special mechanized high pressure jet machines by high pressure jet pum 80-180 bar pressure , which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains. |
| 145 | (v)Anti-Bacterial Treatment ofInside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. |
| 146 | (vi) Cleaing/ above operations shall be executed by trained workers and technicians only. |
| 147 | (vii) Cost of T&P like rods, bamboos, gum shoes and hand gloves etc complete. |
| 148 | (viii) Driver and operator must be in possession of a valid licence and confirm the serviceability of the Truck/ machinery. |
| 149 | (ix) Removal of blockage of sewage lines up to one metre from collection sump including manholes by using necessary tools/ mechanically tools or manually such as passing rope knots, bamboo kamti and disc of required size including safety measures such as test for gas etc. before flushing the pipe well with water after removal of blockage ofpipe complete all as specified and directed. |
| 150 | (x) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with in the given period only. or otherwise penality shall be imposed @ Rs 500/- per day. |
| 151 | Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etcinsoft/loose soil, complete all as specified and directed. |
| 152 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. |
| 153 | Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. |
| 154 | Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. |
| 155 | Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. |
| 156 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 157 | Supply only of GI pipe light grade for cable protection of size 100mm bore with fittings, complete all as specified and directed. |
| 158 | Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 159 | Material and labour in repair for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 160 | Material and labour in repair for 3 ½ core 150 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 161 | Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 150 Sqmm to 185 Sqmm, complete all as specified and directed. |
| 162 | Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 120Sqmmto 185 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. |
| 163 | Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panel,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather, vermi proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall be submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board of any description and reconnecting existing LT UG Cable with new panel board all as directed and comprising of the following:- |
| 164 | (a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 400 Amps ,36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 200 Amps , 25 KA- 01 No.(c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 63 Amps ,10KA- 04 Nos.(d ) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder -01 No.Note :-(i)The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, wiring, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu = 100 % ICs .(v) Make of LT Panel /FPB shall be as mentioned in list of makes (PS). |
| 165 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of alluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/S LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- |
| 166 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA- 02Nos.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA- 01No.(d) MCB SPNof 240 V of capacity 40 Amps 10 KA- 01 No.(e) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(g) Space for spare feeder - 01 No. Note :-(i) The Contractor Shall submit the drawing for approvalof GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 167 | Attending, Repairing/restoring of electric power supply in the AFTC, CQAE and Jalahalli area, after identifying fault in HT 11 KVor LT415 volt system, RMU,VCB,LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size, complete all as specified and directed. |
| 168 | Note :- (i)The abovework also include checking, detectionand rectifcation of LT/HT UG Cable faults at AF Area as and when directed by Engineer-in-Charge/ JE (E/M). |
| 169 | (ii) Hiring of cable fault detector to detect exact location of HT UG cable fault deemed to be inclusive of unit quoted rate. |
| 170 | (iii) Major items required to be replaced/repaired shall be measured under relevant items of schedule/ BOQ. |
| 171 | (iv) Excavation and earth work if required shall be measured separately. |
| 172 | (v) compliants will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days). |
| 173 | (vi) In case of minor defect, entire job shall be completed within 02 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 300 /- per hours shall be recovered from the contractor. |
| 174 | (vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost shall be paid for the same. |
| 175 | (viii) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs.500/- per hours shall be deducted from the dues of the contractor. |
| 176 | (ix)Note that penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regard shall be final and binding. |
| 177 | Supply and fix 4 Pole MCCB, 415 volts, fixed type, 630 Amp, 50 Hz, with rupturing capacity 50 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder pillar box including connecting lugs with busbar and mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed. Make : Indo Asian/L&T/Havells |
| 178 | Surface dressing in any type of soilnot exceeding 15 cm deepand clearing all the grass weeds etc in the sub station yards after removing stone aggregate asideall as directed at site including setting / spreading back the aggregate complete all as specified and directed. |
| 179 | Supply and spreading stone aggregate of size not exceeding 40 mm spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer andpole structure area all as directed |
| 180 | Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. |
| 181 | Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. |
| 182 | Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 70 Sqmm to 95 Sqmm, complete all as specified and directed. |
| 183 | Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 70Sqmmto 95 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. |
| 184 | Supply and fix 4 Pole MCCB ,415 volts,fixed type ,400 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals, replacement to LT panel/ Feeder pillar box by connecting lugs with busbar including mounting arrengments i.e. screws,bolt, nut, washers etc including taking out of old unserviceable MCCB etc, complete all as specified and directed.Make : Indo asian/L&T/ Havells |
| 185 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, complete all as speified and directed and comprising of the following:- |
| 186 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amps, 25 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps,10 KA- 06 Nos.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 40 Amps,10 KA- 01 No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 187 | Repair and servicing of HT 11KV out door type Ring main unit (RMU) of capacity 400 to 630 Amps by opening and replacing all unserviceable parts, cleaning and tightening the terminals, checking the control circuit wiring, spring charging and interlocking mechanism and ascertaining the RMU healthiness for faults tripping system by using secondary injection method and checking breaker, closing coils, checking the tripping circuit and resetting trip values of relays and checking tripping machanism including servicing of the LBScomplete by engaging well experienced technicians as per manufacturer recommendation and all as directed by Engr in Charge. Note: Spare parts shall be measured and paid separately under relevant items. The rated quoted shall deemed to be inclusive of minor spares such as screws, bolts, nuts and all consumables. |
| 188 | Supply only the following spares suitable for 400 to 630 Amp HT RMUs repair work under above schedule items |
| 189 | (i)BushingBolted Type |
| 190 | (ii) Trip coil as per the existing make and type |
| 191 | (iii) Push ButtonGreen/Red W/ Label \"O\" |
| 192 | (iv) Spike Mechanism w/o hex rod |
| 193 | (v) Capacitor Unit, VPIS, 9-15kV without cord |
| 194 | (v) Battery of 1.5 V suitable for RMU |
| 195 | M&L for the current transformer ring type of ratio 40A to 100A/01class 5 P 10, 2.5 VA suitable for 400 to630 Amps HT switch gear panel repair work under above schedule items, all as specified and directed. |
| 196 | Material and labour forthree phase PT of ratio 11000/110V, burden 2.5 VA, class 0.2, voltage factor 1.2 suitable for 400 to 630 Amps HT switch gear panel repair work under above schedule items, all as specified and directed. |
| 197 | Supply and fixing Tite Foam PU sealant (white) ,Expanding Foam for sealing large gap of cable entry of RMU complete allas directed |
| 198 | Supply and fixingGlass putty forthe gap of cable entry of RMU complete all as directed. |
| 199 | Supply and fixingin replacement ofDC wiring of RMU panel including copper wire ,PVCwire holder and other connected items suitable for RMU panel630 A capacity as per existing make including testing and complete all as specified and directed. |
| 200 | Supply and fixing as in repair HT tape roll 35mm width Appx 5 mtr length all as specified and directed. |
| 201 | Material andlabour forTesting of earth resistancevalue from earthing pit test terminal pointand write in/ on existingidentification board complete all as specified and as directed.Around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip comprising of the following process :- |
| 202 | The following items are deemed to be inclusive of quoted rate :-(i)The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documantry proof of the education of tradesman shall be produced by the contractor to the Engr-in-charge, before commencement of work. |
| 203 | (ii)The aforsesaid test will be carried out in presence of user and MES represnetative. |
| 204 | (iii) Two Party (consisting 2 x 1 No. Technician with 2 x 1 No. Helper) willreport every Morningat 9 AM to JE E/M for Daily earth testing. |
| 205 | (vi) Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from Authorised Company/ Lab). |
| 206 | (v) Contractor will be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible). |
| 207 | (vi) Contractor will be responsible for marking of Earth check date and due date on existing Plate with synthetic enamel paint as specified by Engineer-in-Charge. |
| 208 | (vii)Contractor will be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip. |
| 209 | Supply only charcoal dust/Breeze in trenches to improve the ER value of existing earth pits, complete all as specified and as directed. |
| 210 | Supply only common salt commercial in trenches to improve the ER value of existing earth pits, complete all as specified and as directed. |
| 211 | Material and labour for magnesium sulphate (MgSO4) for improvement of earthing resistivity, complete all as specified and directed. |
| 212 | Material and labour for Powder Earthing Backfill Compound, Grade Standard for improvement of earthing resistivity and to increase the absorption of moisture around the earthing electrode, complete all as specified and directed. |
| 213 | Material andlabour for resistancereducing earthing liquid certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A for improvement of earthing resistivity complete all as specified and directed. |
| 214 | Supply and fixing in repair 20 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors etc, complete all as specified and directed. |
| 215 | Supply and fixing in repair 40 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches/or laid in floor etc, complete all as specified and directed . |
| 216 | Supply and Fix in repairs Bib Tap of 15 mm dia standard of PTMT any colour high pressure screwed for iron pipe(Minimum weight 90 gms ), complete all as specifed and directed. |
| 217 | Taking downn unsv funnel of any type and size Supply and fixing in repair GI funnels for earthing, complete all as specified and as directed. |
| 218 | Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, whichever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed includingPCC 1:3:6 type C1 using 20mm graded stone aggregate for pit with cover of RCC 1:2:4 type B1 using 20mm graded aggregate, reinforced with welded steel wire fabric not less than 4 kg per Sqmtr with handle and angle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of common salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning, complete all as specifed and as directed.Note : GI Funnel, brazing, mixture of salt/char coal/MgSO4 shall be measured and paid separately under releavant items. |
| 219 | Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed. |
| 220 | Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mm of 450 mm long to be fixed to ground by means withnecessarycement concrete andpainting with two coats of synthetic enamel paint over a coat of red oxide primer, writing earth reading and connected items like painting of panel etc, and necessary excavation and earth work including taking down old, complete all as specified and as directed. |
| 221 | Material and labourin repairs Galvanised iron Earth strip of size 32 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed. |
| 222 | S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip of any description, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. |
| 223 | Material and labour for Brazing of copper strip for continuity, complete all as specified and as directed. |
| 224 | Taking down existing GI earthstrip 25x3mm thick as earthing lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etc complete all as specified and as directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed. |
| 225 | Supply and fixing in replacement of aluminium strip 25x3mm fixed withinsulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc,.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed. |
| 226 | Taking down of serviceable aluminium strip 25x3mm and refixing the same with epoxy based insulator/post insulator/spacerfor down/ lightening conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed. |
| 227 | Supplying, errecting and fixingas in repair GItubular swaged welded pole of height 5 m long suitable for 900 mmlightening Arrestercompletewith GI base plate with stand fixing over the roof, finial tapper plug cap, bolt, nut and washer etc. The pole shall be fixed with suitable GI clamp weldedfor holding of lightening conductor insulator / post insulator with a distance of 600 mm from top to bottom with PCC (1:2:4) type B-1 using 20mm graded aggregate 750X750 X500 mm over the roof anchored with suitable size bolts complete all as specified and directed . |
| 228 | Supply and fixing in repair copper lightening arrester having 5 spikes of 10mm dia fixed over base plate of size 8.5 x 8.5 cm and 3mm thick and main base rod of 20mm dia and 915mm long fixed to copper strip including nuts,bolts & washersfor earth conductivity to ground complete all as specified and as directed. |
| 229 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 230 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 231 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 232 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 233 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 234 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 235 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 236 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 237 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 238 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 239 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 240 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 241 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 242 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 243 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 244 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 245 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 246 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 247 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 248 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 249 | M&L in repair Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed. |
| 250 | Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panel,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermi proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall be submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No of 16 A 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed and comprising of the following:- |
| 251 | (a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 315 Amps ,36 KA- 01 No. (Incomer).(b) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 200 Amps , 25 KA- 02 Nos.(c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 63 Amps ,10 KA- 06 Nos.(d ) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder -01 No.Note :-(i)The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, wiring, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schenider/L&T/C&S.(iv) MCCB should be ICu = 100 % ICs .(v) Make of LT Panel /FPB shall be as mentioned in list of makes (PS). |
| 252 | Supplying and laying reinforced precast concrete cable cover, class HV, type 1 with flat, size300mm x 180mmx 40mm, all as specified and as directed. |
| 253 | Supply, lay, test and commissioning ofXLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HT UG), 11000 volts grade with stranded aluminium conductor of size 3 core120 Sqmm (Earthed)including taking out existing old unserviceable cable complete all as specified and as directed. Make: Havells/Polycab/RPG AsianNote - Earthwork and bricks to be measured and paid separately under respective items. |
| 254 | Repair and servicing of HT 11KV LBS of capacity 400 Amps to 630 Amps by opening and replacing all unserviceable parts, cleaning and tightening the terminals, checking and greasing of charging mechanism and fault tripping system including servicing of the LBScomplete by engaging well experienced technicians as per manufacturer recommendation and all as directed .Note: Spare parts shall be measured and paid separately under relevant items. The rated quoted shall deemed to be inclusive of minor spares such as screws, bolts, nuts and all consumables. |
| 255 | Supply only the following spares suitable for 400 to 630 Amps HT Load Breaking Switch repair work under above schedule items :- |
| 256 | (i)High repturring capacity fuse unit upto 400 Amps as per sample and suitable for housing in Megawin make out door LBS unit |
| 257 | (ii)Operating mechanism spring as per sample |
| 258 | (iii) Trip Coil suitable for HT LBS as per sample |
| 259 | (iv)Fuse holder assemblysuitable for 400 Amps HT LBS as per sample |
| 260 | M&L for leak testing with pressure testing of SF6 gas ofRMUunits andrectifying the leakage by gas welding / brazing , completepressure testing andSF6 gas charging in the RMU unit , testing and commissioning complete all as specified and as directed. Make of RMU : ABB/SimensNote :- (a) SF6 Gas shall be paid and measured separately.(b) The work shall be executed all as per OEM recommendations. |
| 261 | Supply only SF6 Gas in manufacturer\"s sealed cylinder complete all as specified and as directed. |
| 262 | Supply and fixing Gas fuse plate with fuse and O ring complete all as specified and as directed. |
| 263 | M&L in repair for fabricatedsheet metal board of building panel /LT Panel complete with locking arrangement, fabricated out of3.0 mm thick MS sheetwith powder quotedinternal and external surfaces including taking down old unserviceable rusted sheet metal enclosure complete all as specified and directed.Note:-(a) Size Shall be decided as per site requirement. |
| 264 | M&L in repair for fabricated sheet metal board of building panel /LT Panel complete with locking arrangement, fabricated out of2.0 mm thick MS sheetwith powder quotedinternal and external surfaces including taking down old unserviceable rusted sheet metal enclosure complete all as specified and directed.Note:-(a) Size Shall be decided as per site requirement. |
| 265 | M&L Taking down of serviceable energy meters 4 to 6 Nos ofanytype ,MCB TPN /SPNDB with MCB of 1to 2 Nos , MCCB TPN DBwithMCCBs of 1 to 2 Nosfrom the rusted building main panel and refixing the same in same day after replacement of the new fabricated building main panel and complete all as specified and directed.Note:-(a) Concealed the DBs on wall all including making good and matching with existing surface is inclusive in the quoted rates. |
| 266 | M&L Taking down of serviceable MFM/volt meter/Ammeterof 1 to 2 Nos ofanytype ,MCB TPN /SPN of 1to 2 Nos , MCCB TPN /4 Pole of 1 to 2 Nosfrom the rustedLT panel / Feeder pillar Box and refixing the same in same day after replacement of the new fabricated frame of LT panel / Feeder pillar Box and complete all as specified and directed.Note:-(a) PCC foundation is inclusive in the quoted rates. |
| 267 | Welding of two MS/GI Sheet /Pipes on site of required size including grinding the welded portion and making smooth surface complete all as specified and as directed. |
| 268 | Supply and fixing in repair of Aluminium Bus Bar of existing Size in the existing panel board on site of required shape post insulator with removing and refixing of existing UG cablecomplete all as specified and as directed . |
| 269 | Supply and fixing in repairof copper Bus Bar of existing Size in the existing panel board on site of required shape post insulator with removing and refixing of existing UG cable complete all as specified and as directed . |
| 270 | Supply and fixing in repair LED Indicating lamp (R-Y-B) complete all as specified and as directed by Engineer-in -charge. |
| 271 | Supply and fixing in repair Multifunction Meter (V,I,PF) with suitable capacity of CT\"scomplete all as specified and as directed |
| 272 | Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. |
| 273 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/PVC casing-caping etc as per site requirement onwalls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etccomplete for the following :-Make of wire: Polycab/Plaza/HavellsNote: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 274 | All as per item No.273here in before but forOne light point/fan point controlled by one way 5 Amp switch. |
| 275 | All as per item No.273here in before but forOne light point controlled by two way 5 Amp switch. |
| 276 | All as per item No. 273here in before but for one bell point controlled by one way bell push. |
| 277 | All as per item No.273here in before but forOne 3 pin socket out let 5 Ampon the same board |
| 278 | All as per item No. 273 here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 279 | All as per item No. 273here in before but for Wiring with 2.5 Sqmm copper multistranded unsheathed cable and2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 280 | All as per item No. 273here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 281 | Supply and Fix switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 282 | Supply and Fix switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 283 | Supply and Fix switch piano flush type 5 Amps240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 284 | Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 285 | Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 286 | Supply and Fix shuttered switch socket outlet 2 in 1, 3 pin, 5 and 15 Amps, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 287 | S & F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directedMake : Anchor/Havells/L&T |
| 288 | S & F2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton |
| 289 | S & Felectric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T |
| 290 | S & F in repairfan regulator 120W,for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T |
| 291 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length complete all as specified and directed.Make:- Havells/ Polycab/ Plaza. |
| 292 | S&F in replacementfactory madepowder coated distribution board VTPN, 8 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 293 | S&F in replacement distribution board MCCB four pole, 160Amp ultimate breaking capacity 25 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 294 | S&F in replacementfactory madepowder coated distribution board TPN, 8 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 295 | S & F in repair and replacement TPN, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian |
| 296 | S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 297 | S & F MCB in repair SPN 240 volts 32 Amps suitable for \"C\" curve, 10 KA complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 298 | Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 299 | S & F in repairs 3.0 mm thick hylum sheetof size 4\"x 4\" forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed. |
| 300 | S & F in repairs 3.0 mm thick hylum sheetof size 6\"x 8\" forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed. |
| 301 | S & F in repairs Modular flush metal box 3 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall including making good and matching with existing surface included in the quoted rate. |
| 302 | S & F in repairs Modular flush PVC box 1/2 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screwscomplete all as directed. |
| 303 | S & F in repairs Modular flush PVC box 3 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screwscomplete all as specified and directed. |
| 304 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed. |
| 305 | Supply and fixing in repair building security/ LED street light fitting 35/36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG |
| 306 | Supply and fix GI pipe 32 mm dia, medium grade for mounting bracket, bent to shape 1.5 meter length and fixing arrangement with two Nos ofclamps set, nut, bolts, washers, andincl taking down old unserviceable GI pipe complete all as specified and directed |
| 307 | Supply and Fix in repair switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 308 | Supply and Fix in repair shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 309 | Supply and Fix in repair shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 310 | Supply and Fix in repair shuttered switch socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian |
| 311 | S&F in repairs 35/36 W (WH) LED Surface type2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. |
| 312 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 313 | S&F in replacementfactory madepowder coated distribution board VTPN, 6 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 314 | S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 315 | S&F in replacementfactory madepowder coated distribution board TPN, 6 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 316 | S & F in repair and replacement TP, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian |
| 317 | S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 318 | S & F MCB in repair SPN 240 volts 40 to 63 Amps suitable for \"C\" curve, 10 KA complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 319 | Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 320 | Refixingexisting serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size after cleaning all dust etc. completeall as specified and as directed . |
| 321 | S & F in repairs 3.0 mm thick hylum sheetof size8\"x 8\" forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed. |
| 322 | S & F in repairs 3.0 mm thick hylum sheet of size 8\"x 12\" forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed. |
| 323 | S & F in repairs Modular flush PVC box 4 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. |
| 324 | S & F in repairs Modular flush metal box 4 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 325 | S&F in repairs LED bed side light /wall light/study lightenvironmentel friendly energy effcient of capacity3 W warm whiteetc,inbuilt drivercomplete with all accessories internally pre-wired swing type and including connecting up towith twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj/ Philips / Wipro/CG |
| 326 | Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed . |
| 327 | Disconnecting of burnt/ damaged wire of MCB/MCCB/ TPN/ VTPN DB4/6/8 way etc, cutting out the burnt out ends, making new end joints by supply and fixing new copper lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 1.5 Sqmmto 10 Sqmm single core of LT copper wire.Note :- Cementand painting work required for make goodthe incoming/ outgoingwire of MCB/MCCB TPN DBetc shall deemed to be included in the unit rate quoted. |
| 328 | M& L for preparation to internal and external old steel surface of Main building distribution Board / Main building distribution Board of various size and completely removal of existing treatment by scraping or chemical and surface painted with Synthetic enamel paint with help of spray gun over a coat of red oxide primer complete all as specified and as directed. |
| 329 | S&F in repairs 35/36 W( WH) LED recessed type 2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. |
| 330 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 331 | All as per item No. 330 here in before but for one light point/fan/bell point controlled by one wayswitch. |
| 332 | All as per item No. 330here in before but for one light point controlled by twowayswitch. |
| 333 | All as per item No. 330here in before but for one bell point controlled by one bell push. |
| 334 | All as per item No. 330 here in before but for one 3 pin socket out 5 Ampon the same board |
| 335 | All as per item No. 330 here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 336 | All as per Sl No 330 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independentlycomplete all as specified and directed. |
| 337 | All as per Sl No.330 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 338 | Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 339 | Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian |
| 340 | Supply and Fixmodular switchbell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian |
| 341 | Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 342 | Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 343 | Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 344 | Supply and fix White cover plate with frame,2/3 module |
| 345 | Supply and fix White cover plate with frame,4 module |
| 346 | Supply and fix White cover plate with frame,8 module |
| 347 | Supply and fix White cover plate with frame,6 module |
| 348 | Supply and fix White cover plate with frame,12 module |
| 349 | S & F in repair Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor |
| 350 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)4 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 351 | S&F in replacement factory madepowder coated distribution board SPN 6 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 352 | S&F in replacement factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 353 | S & F in repair MCB single pole 240 volts 6 to 32 Amps suitable for \"C\" curve, 10 KA complete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. |
| 354 | S & F in repair MCB single pole 240 volts 40 to 63 Amps suitable for \"C\" curve, 10 KA complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian |
| 355 | Supply and Fixin repair and replacement ofsurface mounted Square/Roundfor LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed.Make : Philips/ Bajaj/ CG/Havells. |
| 356 | S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 357 | Supply and fix 4 Pole MCCB, 415 volts, fixed type, 250 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals, replacement to LT panel/ Feeder pillar box including connecting lugs with busbar and mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed. Make : Indo Asian/L&T/Havells |
| 358 | S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 359 | Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 10 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as per Cat Part No - LBLSN-10-CDL of Make : Crompton or equivalent in Halonix/Bajaj/ Philips |
| 360 | Suply and fix in repairs LED decorative post top lantern fitting 40 W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection completeall as specified as directed. Make: Bajaj / Philips/Halonix/ CG |
| 361 | Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed. |
| 362 | Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. |
| 363 | M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to poleincluding necessary form work slightly rounding or squaring, complete all as specifiedand as directed. |
| 364 | M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles etc, complete all as specified and as directed |
| 365 | M&L for Octgonal GI poles complete with GI base plate finial taper plug, bolts, nuts and screws,with suitable bracketall as specifiedof height 7 M including necessaryEarth work,PCC foundation copping etc and refixing of all existing fitting fixture from existing old electric pole complete all as specified and as directed Make - Philips /Bajaj/Havells/Surya |
| 366 | Supply and fixing in repair LED street light fitting of 60 watts, 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed. Make : Bajaj/Surya/CG/Halonix |
| 367 | Supply and fix in repair bracket for street light fitting made out of40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed. |
| 368 | Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. |
| 369 | Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/Havells |
| 370 | Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 25Sqmmto 35 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. |
| 371 | Disconnecting of burnt/ damaged wire of MCBSPN DB4/6/8/12 way etc, cutting out the burnt out ends, making new end joints by supply and fixing new copper lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 1.5 Sqmmto 10 Sqmm single core of LT copper wire.Note :- Cement and painting workmake goodthe incoming/ outgoing wire in wire of MCBSPN DBetc shall deemed to be included in the unit rate quoted. |
| 372 | S&F in replacement distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 373 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/S LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :- |
| 374 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 36 KA 4 Pole - 01 No. (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps, 25 KA - 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amps, 25 KA - 01 No.(d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps, 10 KA - 01 No.(e) MCB TPNof 415 V of capacity 40 Amps 10 KA- 01 No.(f) MCB SPNof 240 V of capacity 40 Amps 10 KA- 01 No.(g) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(h) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(i) Space for spare feeder - 01 No. Note :-(i) The Contractor Shall submit the drawing for approval of GEbefore executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 375 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure shall be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one Nopolycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6)type C-1 using 20mm graded/ stone agregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :- |
| 376 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA- 01 No. (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity250 Amp,25 KA- 01No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp,25 KA- 04 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 377 | Note :- An amount of Rs 2,73,379.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |