| 1 | Sch \"A\" |
| 2 | Taking down existing street light fittings of any type/size/capacityfixed in any position i.e. on wall/ pole/ watch tower refixing the fitting in its original position after repairs complete all as specified and directed. (Note:-Spares shall be measured and paid separately under item No 05 & 06.) |
| 3 | S&F in replacement LED street light luminaire of 45 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having Efficiency ≥ 120 Lumen/watt, 10KV SPDwith provision of 2.5 sq mm three core copper conductor cable multi stranded from fitting to security light junction box including taking down the old unserviceable light of same cap Brand name should be embossed on fixture to ensure Indian brand only complete all as specified and directed. |
| 4 | S&F in replacement LED Sensor street light luminaire of 60 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having Efficiency ≥ 120 Lumen/watt, 10KV SPDwith provision of 2.5 sq mm three core copper conductor cable multi stranded from fitting to security light junction box including taking down the old unserviceable light of same capacity Brand name should be embossed on fixture to ensure Indian brand only complete all as specified and directed. |
| 5 | S & F in replacement LED Sensor street light luminaire of 90 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficiency ≥ 120 LPW, 10KV SPDwith provision of 2.5 sq mm three core copper conductor cable multi stranded from fitting to security light junction box including taking down the old unserviceable light of same capacity Brand name should be embossed on fixture to ensure Indian brand only complete all as specified and directed. |
| 6 | S & F in replacement LED flood light fitting of 120 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimumwith IP-66, protection for LED and control gear compartments with high power LED chipssuitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficiency ≥ 130 lumen/watt, 10KV SPDincluding taking down the old unserviceable light of same capacity complete all as specified and directed. |
| 7 | S&F in replacement LED flood light fitting of 150 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimumwith IP-66, protection for LED and control gear compartments with high power LED chipssuitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficiency ≥ 130 lumen/watt, 10KV SPDincluding taking down the old unserviceable light of same capacity complete all as specified and directed. Note for Ser No 2 to 6 :- (ii) All LED fittings shall have supporting LM-79 & LM-80 test certificate from govt approved NABL/UL accredited Labshowing all the parameters duly signed by the local office bearer of manufacturer. |
| 8 | S&F in replacement of copper conductor cable3 core 2.5 Sqmm 1100 volts multistranderd PVC insulated weather proof, sheathed heavy duty ISI marked drawing through 20mm dia PVC pipe/conduit from LED street light fitting to junction box with proper connection with thimbles as per site requirement complete all as specified and directed. |
| 9 | Supply and fixing in replacementof driver suitable for any type of street light 45W/60W/90W complete all as specified and directed. |
| 10 | Supply and fixing in replacementof Surge protection device suitable for any type of street light 45W/60W/90W complete all as specified and directed. |
| 11 | Supply and fixing in replacement SMC pole junction box of size 300x200x105,dust proof, water tight weight acid resistence, corrosion proof insulated and shock proof fire retardant self extingushing, halogen & silica free non-Toxic material,UV resistance (UI subject 94:V2) with internally embeded gasket size of test certificate and verification by glow wire test in accordance with IEC60695-2-11 cat no-K8250with 6 Amps MCB SP neutral link with three phase copper busbar 63 amps TPN connector for connection of cable of suitable size complete all as specified and directed. |
| 12 | M&L for replacement TPN MCB,4 pole 415 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 40 to 100 Amps, C curve complete all as specified and directed. |
| 13 | M&L for replacement MCB SPN, 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating32 Amps complete all as specified and directed. |
| 14 | M&L for replacement MCB SP 5 to 32 Amps, 10 KA,C-curve complete all as specified and directed. |
| 15 | M&L painting of cement concrete poles with junction box,clamp and bracket any type of size externally above foundation with two coats of cement base paint for pole after scraping/cleaning well the existing surface with black and yellow or black white strips 30cm each up to 1.5 metre height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mm x 230mm yellow base complete all as specified and directed. |
| 16 | M&L painting of LT Steel tubular pole with junction box,clamp and bracket any type of size externally above foundation with two coat of aluminium paintafter scraping/cleaning well the existing surface incl painting of bottom with black white or yellow color strip 30cm each upto 1.5 mtr high from top of PCC foundation block and numbring of pole with synthetic enamel paint white in 80mm high letter over 150mmx230mm yellow base complete all as specified and directed. |
| 17 | Supply and fixing in replacement,bracket made out of 40 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete all as specified and directed.(Rates quoted by the contractor shall deemed to include for nut and bolts). |
| 18 | Supply and fixinginsulation LT tape size normal width 20mm, length 25 mtr, thickness 0.125mm complete all as specified and directed. |
| 19 | M&L for PCC 1:2:4, type B-1 using 20mm graded crushed stone aggregate for coping of poles & LT panels complete all as specified and directed. |
| 20 | Supply, laying, jointing, testing and commissioning in replacement of cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade,laid in trenches, fixed by means of MS saddles on or fixed on poles including connection with proper lugs for the following size including taking out old XLPE cable etc complete all as specified and directed. Note :- (i) Excavation and earth work shall be measured and paid separately. |
| 21 | 10 Sqmm 2 Core |
| 22 | 10 Sqmm 4 Core |
| 23 | 25 Sqmm 3.5 Core |
| 24 | 35 Sqmm 3.5 Core |
| 25 | 50 Sqmm 3.5 Core |
| 26 | 95 Sqmm 3.5 Core |
| 27 | 120 Sqmm 3.5 Core |
| 28 | 50 Sqmm 3.5 Core |
| 29 | Excavation in trenches in soft loose of soil not exceeding 1.5 mtr wide and not exceeding 1.5metre in depth for taking out of unserviceable under ground cable complete all as specified and directed. |
| 30 | Material and labour for sand cushioing with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Notes-:(i) Excavation and earth work to be measured and paid for separately. (ii)Thickness of 18cms after punning shall be considered for payment. |
| 31 | Supplying and laying bricks common brunt clay building bricks sub class \"B\"including removing of old bricks complete all as specified and directed. |
| 32 | Returning, filling in, any type of soil and spreading, in layers not exceeding 25 cm thick complete all as specified and directed. |
| 33 | Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed& complete all as specified and directed. |
| 34 | Supply and fix of Aluminium Lugs uitable for 16 to 35 Sqmm 1100 Volts including taking down old unserviceable lugs complete all as specified and directed. |
| 35 | Supply and fix of aluminium Lugssuitable for 70 to 185 Sqmm1100 Volts including taking down old unserviceable lugs, complete all as specified and directed. |
| 36 | Supply and fixing in replacment GI pipe light grade 80 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking out old GI pipe complete all as specified and directed. |
| 37 | M &L Earthing incl earth work complete with galvanised steel earth plate electrode60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner. |
| 38 | Supply and fixing in replacement digital voltmeter (0-500 Volts ) 96x96mm square type including taking out old unserviceable voltmeter complete all as specified and directed. |
| 39 | Supply and fixing in replacement digital Amps meter (0-600 Amps ) 96x96mm aquare type including taking out old unserviceable seperator complete all as specified and directed. |
| 40 | Material and labour for replacement of indicator lamp in red, yellow and blue colour with lamp holder multi LED type complete including wiring with copper conductor cable of suitable size complete all as specified and directed. |
| 41 | Supply and fixing in replacement of MCCB of current rating 400 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal, adjustable magnetic type releaseand spreader linkas per site requirement including taking down old unserviceable MCCBs complete all as specified and directed. |
| 42 | Supply and fixing in replacement of MCCB of current rating 315/320 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal, adjustable magnetic type release and spreader linkas per site requirement including taking down old unserviceable MCCBs complete all as specified and directed. |
| 43 | Supply and fixing in replacement of MCCB of current rating 250 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal, adjustable magnetic type release and spreader linkas per site requirement including taking down old unserviceable MCCBs complete all as specified and directed. |
| 44 | Supply and fixing in replacement of MCCB of current rating 200 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal, adjustable magnetic type release,Ics=100% Icu with spreader linkas per site requirement including taking down old unserviceable MCCBs complete all as specified and directed. |
| 45 | Supply and fixing in replacement of MCCB of current rating 160 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal, adjustable magnetic type release,Ics=100% Icu with spreader linkas per site requirement including taking down old unserviceable MCCBs complete all as specified and directed. |
| 46 | Supply and fixing in replacement of MCCB of current rating 125 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal, adjustable magnetic type release,Ics=100% Icu with spreader linkas per site requirement including taking down old unserviceable MCCBs complete all as specified and directed. |
| 47 | Supply and fixing in replacement of MCCB of current rating 100 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal, adjustable magnetic type release,Ics=100% Icu with spreader linkas per site requirement including taking down old unserviceable MCCBs complete all as specified and directed. |
| 48 | Supply and fixing in replacement of MCCB of current rating 63 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal, adjustable magnetic type release Ics=100% Icu with spreader linkas per site requirement including taking down old unserviceable MCCBs complete all as specified and directed. |
| 49 | S & F Straight Through Joints (heat shrinkable) including Jointing Kit complete for making Joints suitable for LT UG Aluminium Conductor cable 11000 volts grade 16 Sqmmto 35 Sqmm including necessary excavation of earth work and removal of existing unserviceable one complete all as specified and directed. |
| 50 | S & F Straight Through Joints (heat shrinkable) including Jointing Kit complete for making Joints suitable for LT UG Aluminium Conductor cable 11000 volts grade 50 Sqmmto 150 Sqmm including necessary excavation of earth work and removal of existing unserviceable one complete all as specified and directed. |
| 51 | Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables complete all as specified and directed. |
| 52 | M&L for stone aggregate of size 40mm to 80 mm spreading over as per requirement in the sub station areas/2 Pole/4 Pole structure including proper levelling complete all as specified and directed. |
| 53 | M&L for taking down unserviceable High Mast Light Fitting Set from any Height, repairing the same at site by opening cover after bringing down by using control gear box symmetrically fitted along with steel rope, replacing unservicable Parts such as driver, SPD and unserviceable/ burnt cable, etc. as required at site, after repairing fixing in the same Position including necessary greasing the gear box, checking control mechanisum with minor repairs as required complete all as specified and directed. Note : (a)Spare Parts such as driver, Surge protection devicerequired will be measured and paid under appropriate Item(s) as ‘Supply only fix in item No 45 & 46.(b)Labour Element for replacement of unserviceable Parts will deem to be included in the Quoted Unit Rate. |
| 54 | Supply and fixing in replacementof driver suitable for any type of street light 120W/160W complete all as specified and directed. |
| 55 | Supply and fixing in replacementof Surge protection device suitable for any type of street light 120W/160W complete all as specified and directed. |
| 56 | Supply and fixing PVC insulated,PVC sheathed multistranded copper conductor cable of size 4 core 10 Sqmm with necessary electrical connections from switch gear to high mast top connector block including taking down old unserviceable one complete all as specified and directed. |
| 57 | Supply only Stain less steel rope twisted of size 10 mm dia with necessary connections proper binding on both sides from bottom drum mast top connecting hook including taking down old unserviceable one complete all as specified and directed. |
| 58 | M&L Pruning of tree branches around LT over head electric lines and cleaning 3 Mtrs from the line, removing cut materials ( tree branches) from site and stacking properly where directed complete all as specified and directed. |
| 59 | S & F Surface/pole mounted astronomical time switch paneloutdoor type of suitable size cubical type factory made, weather and vermin proof made out of polycarbonate thermoplastic outdoor junction box/CRCA sheet thick panel duly powder coacted heaving Astronomical time switch, Contactor suitable for street light time switch with duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles,with cable gland andfixed on wall/pole with clamp, nut & bolts complete all as specified and as directed. Main Incomer MCB 32A FP 10 KA - 1 No., Contractor 3P 40Amp with Digital Time Switch for Auto On/Off - 1 Set, Selector Switch for bypass Arrangement - 1 No, LED Indicators, Street Light DB shall 12KW complete with Suitable Glands, Pole Mounting Clamp with Nut Bolts etc.complete all as specified and directed. |
| 60 | S&F Contactor suitable for Street Light Time Switch 4 Pole, 100 Amps, 415 Volt, including taking down old unserviceable Contactor complete all as specified and directed. |
| 61 | S&F Integral LED aviation light comprising of aluminium housing with ploycarbonate enclosure including taking down old unserviceable light from any height of OH tank complete all as specified and directed. |
| 62 | S & Fon load Auto Changeover 415 V4 pole of capacity 63 Amps complete all as specified and directed. |
| 63 | S & Fon load Auto Changeover 415 V4 pole of capacity 100 Amps complete all as specified and directed. |
| 64 | S & F for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 66 protection complete with all accessories fixed on GI pipe 50 mm dia including removal of old unserviceable one complete all as specified and directed. |
| 65 | Checking the fault in the LT distribution cable of any size and length at any location withfault detector machine and inserting straight through cable joint kits (LT) and piece of LT UG cable as required length after determining the fault location including earth work at any strata as required depth and widthand testing complete all as specified and directed.Note:- i) Fault detector machine & other equipment shall be arranged by the contractor.ii) Cable jointing kit and LT UG cable measured and paid seperatly under relevant items below. |
| 66 | Labour only for laying LT UG Cable of any description and size (serviceable cable obtained from item No 19 here-in-before), laid in trenches/ surface of Wall/in GI Pipe along with Pole for connection to pole/junction box/OH Lines including Brass cable glands MS flat iron clamps, etc. and testing complete all as specified and directed. Note : (i)Earth wors, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. (ii)Cost of shifting of Cables at Work Sites as ordered is deemed to be included in the Quoted Unit Rate. |
| 67 | Supply,installing, testingand commissioningout door type control panel for security light made out of 3 mm thick CRCA sheet with top canopywith locking arrangementsof suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side , having proper locking arrangement in both front and rear door and painted with powder coating paint and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Plat form all round the panel board complete with the following items housed in :- (a) MCCB 4 Pole 63 Amps, RotaryHandle, adjustable Thermal, adjustable Magnetic relay with breaking capacity 25 KA at 415 voltsIcs=100% Icu - 01 No (in coming) (b) MCCB 4 Pole 63 Amps, Rotary Handle, adjustable Thermal, adjustable Magnetic relay with breaking capacity 25 KA at 415 voltsIcs=100% Icu - 02 Nos (out going) (c)Digital time switch Astro type, daily astronomical caculation of sunrise/ sunset times based on the entered location or location condition of Ludhiana area including power contractor of capacity 63 Amps) including necessary wiring complete - 01 No.(d) Digital Voltmeter 0 - 500 Volt with selector switch- 01 No. (e)Digital Ammeter0 - 100 Amps with selector switch - 01 No. (f) Copper wound with CTR 100/5 - 03 Nos (g) Indicator Lamps (LED type) showing R,Y, B phase - 01 set |
| 68 | S&F Surface/pole Mounting Digital time switch Astro type, daily astronomical caculation of sunrise/ sunset times based on the entered location or location condition of Ludhiana areaand connecting with contactor with necessary electrical connectionsin existing panelincluding taking down old unserviceable one complete all as specified and directed. |
| 69 | M&L for retreatement of earthing by removing old earth pit and refilling Charcol & Salt cristals of 50 Kg Each including taking out old expired chemical/Charcol/ Salt and refilling of soil, watering & well ramming and constrction of new earth Chamber with fixing of funnel complete with colour code such as green for body earthing/blue etc complete all as specified and directed. |