| 1 | Supply, fixing and testing of Flood light 200 Watt at existing pole. Make: Havells JETAIRSMAXFLS200WLED757PWBLTG or equivalent. |
| 2 | S&F submain wiring with Four run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 2.5 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitalbe size ISI marked Medium grade, fixed on/through wall, ceiling including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed. |
| 3 | S&F MCB SPN 32 Amps, 10 kA, C Curve complete all as specified and as directed. |
| 4 | S&F MCB Single Pole 6-32 Amps, 10 kA, C Curve complete all as specified and as directed. |
| 5 | S&F SPN DB Double door 2 way with tray for provision of MCBs, and Dolly for earth and netural complete all as specified and as directed. |
| 6 | Supply and fixing 4 pole contactor MCX 11/12/13, AC-1:50A Coil 240 Volt, 50 Hz upto 415 V 50/60 Hz complete all as per direction of engr-in-charge. |
| 7 | S&F street light timer analog clock type 3 module with battery backup, programmable for every 15 min, and connected to existing power contact fdor controlling complete alll as specified and as directed. |
| 8 | DismantlingRCC fencing Posts embedded in concrete, any section, including taking out embedded portion and removal of surplus excavated materials to a distance not exc 50m all as specified and directed |
| 9 | Dismantling offencing wire mesh of any descripyion including round bar,line wires , flat iron, clamps etc complete all as specified and directed by Engineer-in-Charge |
| 10 | Excavation in post holes (or simlar holes) each n.exc 0.50cum, getting out, returning, filling and ramming including disposal of surplus soil complete all as specified and directed |
| 11 | M&L forPlain cement concrete 1:4:8 mixtype D-2 (using 40mm graded stone aggregate)as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge |
| 12 | M&L for Mild steeldeformed TMT bars 8mm diaas in reinforcement to concrete, cut to length, bent to shape required incl cranking, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm diacomplete all as directed by Engineer-in-Charge |
| 13 | M&L for mild steel deformed TMT bars 5mm dia andupto and including 10mm dia as in stirrups, spacers, cut to lengyh, bent to shape required, including cranking, ooking ends and binding with and including mild steel wire (annealed) not less than 0.90mmdia complete all as directed by Engineer-in-Charge |
| 14 | M&L for providingReinforced cement concrete type B-1, 1:2:4mix ( using 20mm graded stone aggregate) as in precast posts, fencing posts, staining or terminal posts, struts etc. for fencing, , avarage sectional area exc 100sqcm and n.exc 250sqcm with or with out chamfered angles and flat, splayed, rounded or mitred tops and fixed complete all as specified and directed by Engineer-in-Charge |
| 15 | S&F for mild steel machine made screw bolts of 5 to 10mm dia (diameter of neck in mm) hexagonal or square heads at one end and screwed the othe, screwed end fitted with washers and one hexagonal or square nut exc 10cm but n.exc 15cm long all as specified and directed by Engineer-in-Charge |
| 16 | S&Fin repair Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and staining and fixed to RCC precast fencing posts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc.fixed in repairs complete all as specified and directed by Engineer-in-Charge. (Each line wire to be measured) |
| 17 | S&F PVC coated chain link fencing of mesh size 50 X 50 X 4mm dia wire ( 1.50 mm PVC coating over 2.50mm dia wire) fixed to any type of standard rails, posts, staining bolts etc. all as specified and directed by Engineer-in-Charge |
| 18 | S&FFe-290 Gde E-165 mild steelflat iron fillets for securing wire mesh etc. including all necessary drilling holes for bolting or riveting etc. and similar workall as specified and directed by Engineer-in-Charge |
| 19 | S&FFe-290 Gde E-165 mild steelwork as in clamps, hold fasts, hooks etc., and similar small articlesall as specified and directed by Engineer-in-Charge |
| 20 | S&F for mild steel machine made screw bolts not exceeding 5cm long with 5 to 10mm (diameter of neck) hexagonal or square heads at one end and screwed the othe, screwed end fitted with washers and one hexagonal or square nut 5cm long all as specified and directed by Engineer-in-Charge |
| 21 | M&LMild steel bar round bars 10mm dia and over in fencing,cut to length, bent to shape required incl cranking, bending,hooping ends and binding etc., conforming to Gde 1, IS-432 (Party-1) all as pecified and directed |
| 22 | M&L for preparation of new or previously untreated surfaces of steel and iron surfaces of any description over 10cm width or girth, and applying two coats of synthetic enemal paint over a coat of red oxide or zinc chrome primer all as specified and directed by Engineer-in-Charge(Make: ASIAN/SHALIMAR/BERGER/JHONSON & NICHOLSON ) |
| 23 | M&L for preparation of newy plastered surfaces of RCC fencing posts/pillars etc and applying three coats ofwhite wash, including preparation of surfaces all as specified and directed by Engineer-in-Charge |
| 24 | Taking down cementor cement lime plaster, any description, on brick walls including racking out joints hacking for keyscrubbing down with water etc. all as specified and directed. |
| 25 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished the surfaces even and smooth with out using extra cement all as specified |
| 26 | M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash over a coat of alkali resistant priming paint all as specified and directed. |
| 27 | M&L forFramed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as spd and as directed. |
| 28 | M&L 75mm thick cement concrete type C-2 1:3:6 (40mm graded aggregate) as in plinth protection for fixing of grill and packing with concrete complete all as specified and as directed. |
| 29 | Demolition of Concrete of any description and in any position not otherwise specifically provided including removal of debris for complete all as directed. |
| 30 | supplied and fixed in grill work Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia n exc 4 kg wt per sqm complete all as directed. |
| 31 | M&L for Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type E-11all as specified and directed. |