| 1 | Taking down carefully copper/ aluminum point wiring (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, socketslight fittings etc , removing material to store for keeping in safe custody or for taking credit , and making good disturbed surface of walls, floors, etc. complete all as specified and as directed. |
| 2 | M&L forpoint wiring with 1.5 Sqmm single core PVC insulated unsheathed multi stranded copper conductor FRLSH cable 1100V grade drawn through and incl PVC concelled conduit with accessories like bends tees, junction boxes etc fixed recessed in wall or ceiling etc including 1.5 Sqmm single core PVC insulated but unsheathed multistrandard copper conductor FRLSH cable 1100V grade as earth continuity wire incl modular sunken type pressed steel terminal boxes of size with 3mm thick bakelite steel white/coloured top cover for the following:-(a) One light pointcontrolled by one switch complete |
| 3 | All as per item No 2 here in before but One fan point controlled by one switch. |
| 4 | All as per item No 2 here in before but One 3 pin socket out let 5 Amps on the independent board. |
| 5 | All as per item No 2 here in before but One 3 Pin socket out let 5 Amps on the same board. |
| 6 | All as per item No 2 here in before but with cable of size 2.5 Sq mm PVC insulated on independent boardfor power plug 15 Amps. |
| 7 | All as per item No 2 here in before but with cable of size 4 Sq mm PVC insulated on independent boardfor power plug 15 Amps. |
| 8 | Supply and fixingModular switch one way 6A, 1 Module, complete all as specified and directed. |
| 9 | Supply and fixingModular switch one way 16A, 1 Module, complete all as specified and directed. |
| 10 | Supply and fixingModular socket 6/10A-2/3 pin combined 2 Module complete all as specified and directed. |
| 11 | Supply and fixing Modular socket 16/15A-2/3 pin combined2 Module complete all as specified and directed. |
| 12 | Supply and fixingModular Fan Regulator, 120W, 2 module complete all as specified and directed. |
| 13 | Supply & fix ceiling rose 3 terminal/ poly carbonate, isolated body complete all as specified and directed. |
| 14 | Supply and fixing in replacement of 3 pin plug top 16 Amp, 240 volt complete all as spcified and directed. |
| 15 | Supply and fixing in replacement white cover plate with frame, 3 module complete all as specified and directed |
| 16 | Supply and fixing in replacement white cover plate with frame, 4 module complete all as specified and directed |
| 17 | Supply and fixing in replacement white cover plate with frame, 6 module complete all as specified and directed |
| 18 | Supply and fixing in replacement white cover plate with frame, 8 module complete all as specified and directed |
| 19 | Supply and fixing in replacement white cover plate with frame, 12 module complete all as specified and directed. |
| 20 | M&L for concealed sub main wiring complete with PVC insulated FRLSH cable of single core 4 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conduiting PVCConduit with accessories incl 4 Sqmm unsheathed multi standard FRLSH copper conductor as earth wire complete all as specified and directed. Note: Two runs of cable and one run of conduit & earth wire shall be measured as one run length. |
| 21 | M&L for concealed sub main wiring complete with PVC insulated FRLSH cable of single core 6 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conduiting PVCConduit with accessories incl 6 Sqmm unsheathed multi standard FRLSH copper conductor as earth wire. Note: Two runs of cable and one run of conduit & earth wire shall be measured as one run length complete all as specified and directed. |
| 22 | M&L for concealed sub main wiring complete with PVC insulated FRLSH cable of single core 10 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conduiting PVCConduit with accessories incl 10 Sqmm unsheathed multi standard FRLSH copper conductor as earth wire. Note: Two runs of cable and one run of conduit & earth wire shall be measured as one run length complete all as specified and directed. |
| 23 | M&L for concealed sub main wiring complete with PVC insulated FRLSH cable of single core 16 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conduiting PVCConduit with accessories incl 16 Sqmm unsheathed multi standard FRLSH copper conductor as earth wire. Note: Two runs of cable and one run of conduit & earth wire shall be measured as one run length complete all as specified and directed. |
| 24 | S & F in replacement of Casing N Caping patti of any size upto 50 mm dia includingall fittings i.e. Tees, bends, etc of colour as directed by Engr-in-Charge complete all as specified and directed. |
| 25 | Supplying and fixing of sheet meal enclosure for VTPN DBs 4 way with addl space to fix the 100 Amps MCCB complete all as specified and directed. |
| 26 | Supplying and fixing of sheet metal enclosure, single phase, double door SPN DB 12 way, flush to wall mounting for MCB fitted with 200 Amp ratedbus barsand neutral links ( without MCB\"s) SPN/ TPN complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fixing of MCCB 415 Volts, 16 KA, 4 pole of 100 Amps rated capacity complete all as specified and directed. |
| 28 | Supplying and fixing 415 Volts 10 KA \"Ç\" Curve MCBTPN4 pole of 63 Amp capacity complete all as as specified and directed. |
| 29 | Supply & fix MCB SP 6 to 32 Amps 10 KA 240 V, 10 KA \"Ç\" Curvecomplete all as specified and directed. |
| 30 | M & L for single pole and neutral enclosure with a two pin earth plug socket complete with one ssingle pole MCB of 20 Amp capacity complete all as specified and directed. |
| 31 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 32 | Supply and fixing in replacementLED luminaire 600 mm x 600 mm,36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare freelightwhite/warm white/multi coloured (quantity as directed and decided by Engineer in Charge) complete with driver, holders & LED lamp suitable for false ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 33 | Supply and fixing in replacementround shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free white light complete with drivers, holders ,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 34 | Supply and fixing in replacementwall mounting/surface mounting/focus light/mirror light CRCA body powde coated and colour as directed by Engr in Charge of 12/15 watt capacity with conencting up with three core flexible copper cable of suitable size complete all as specified and directed. |
| 35 | Supply and fixing in replacementLED street light fitting 60 Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 36 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 HZ of Size 300 mm complete all as specified and directed.Note :- (a)Making hole in existing brick/PCC wall of required size to accommodate exhaust fan and fixing louvers on outer surface shall be deemed to be inclusive of quoted rate by the contractor. |
| 37 | Supply & fix ceiling fans complete with blades, down rods as per site requirement ,and accessories, 1 Phase, 230 V, 50 Hz, AC, 1200 mm sweep. Min air delivery 210 CFMwith brushless direct current motor (BLDC, including down rod, Nut, Bolt, Clamp, hold fastener)complete all as specified and directed. |
| 38 | M & L for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6mm thick burried directly in ground not less that 2.25 m deep below normal ground level and top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI wire of 40 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical palte No 3 connected to earthing test point incl excavation, earth work in any type of soil strata, PCC chamber, 40 mm dia GI med grade pipe as protection of strip and 15 mm dia GI Med grade watering pipe, funnel, wire mesh etcincluding testing on complete all as specified and directed. |
| 39 | Supply, install, testing and commissioning ofservo controlledVoltage stabilizer (confirming to BIS 9815: Part I : 1994)for automatic operation, three phase, naturally oil cooled, outdoor type, plinth mounted & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% , rated frequency 50 Hq, No distortion in wave form, response time not to exceed 20 mile second, efficiency more than 95%,suitable for three phase unbalanced load , digital display of voltmeter, ammenter incl first filling of transformeroil upto level,copper wound,metallic body duly powder coated with lifting hooks two nos, digital display type relay free smooth and silent operation incl all other accessories reqd for functioning and speed of correction 8 Volts per second and of capacity 30 KVAhaving over load.short circuit protections, high/low voltage cut off, By pass arrangement in case of emergency and single phase sequence change protection complete all as specified and directed.(Note :- the rate quoted is deemed to include the rate of making plinth to install the stabilizer and the height of the plinth shall not be less thanbe 1 mtr from existingground level or as directed by Engr-in-Charge). |
| 40 | M & L for Surface dressing n exc 15 cm deep and getting out complete all as specified and directed. |
| 41 | M & L hardcore of broken bricks of gauge n.exc.63mm, eposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface complete all as specified and directed. |
| 42 | M&L 150 mm thickPCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base, complete all as specified and directed. |
| 43 | M&L100mm thick (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate as in hard standing etc finished with without using extra cement, complete all as specified and directed. |
| 44 | M&L 75 mm th PCC 1:2:4 type B-2using 40mm graded aggregate as in Plinth Protection, finished even and smooth without using extra cement complete all as specified and directed. |
| 45 | Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as specified and directed. |
| 46 | Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm in Soft/loose soil complete all as specified and directed. |
| 47 | Removal of excavated material at a distance notexc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting pointin Soft / loose soil complete all as specified and directed. |
| 48 | Supply and layingdry Sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and directed.Note: - Thickness after punning will be measured for payment. |
| 49 | Supplying and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mmx 40mm complete all as specified and directed by Engineer in charge. |
| 50 | Supply and layand testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 35 Sqmm 3.5 Core complete all as specified and as directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. |
| 51 | M & Lin replacement of Earthing complete in repairs with galvanised steel earthelectrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth leadas eGI strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.Note: (i)Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order.(ii) Necessary excavation wk is included in this item. |
| 52 | M & L for Repair to Washer Extractor of cap 60kg by disconnecting electrical, water and steam connection for overhauling and servicing of machine, balancing of inner basket, replacement of old/rusted parts (as follow from item No 53 to 65) complete all as specified and directed.Note : Spares required for replacement will measured and paid separately under respective items here-in-after of this schedule. |
| 53 | M & L for Replacement of water solenoid as per existing and suitable size complete all as specified and directed. |
| 54 | M & L for Replacement of steam solenoid as per existing and suitable size complete all as specified and directed. |
| 55 | M & L for Replacement of drain assembly valve as per existing and suitable size complete all as specified and directed. |
| 56 | M & L for Replacement of Temperature sensor probe as per existing size complete all as specified and directed. |
| 57 | M & L for Replacement of Relay card with base 8pin 230V as per existing capacity complete all as specified and directed. |
| 58 | M & L for Replacement of Power supply (SMPS) 4-5 Amps as per existing complete all as specified and directed. |
| 59 | Taking down the main bearing housing assembly in drum for replacement of bearings and re-fixing the same with necessary connected items using chain pulley complete all as specified and directed. |
| 60 | M & L for Replacement of front and rear bearings in drum as per existing size complete all asspecified and directed. |
| 61 | M & L for Replacement of oil seal as per existing size complete all asspecified and directed. . |
| 62 | M & L for Repair/Replacement of VFD by new controller relay system box with IGBT as per existing and suitable size complete all as specified and directed. |
| 63 | Taking down the electrical panel of machine & taking out old/unsv parts and wires and rewiring the same with new cables/wires & re-fixing the panel in machine complete all as specified and directed. |
| 64 | Taking down electrical motor and servicing & rewinding the same and re-fixing in machine complete all as specified and directed. |
| 65 | M & L for Foundation work as required for no vibration during operation of machine complete all as specified and directed. |
| 66 | M & L for Repair to Washer Extractor of cap 30kg by disconnecting electrical, water and steam connection for overhauling and servicing of machine, balancing of inner basket, replacement of old/rusted parts (as follow from item No 67 to 79) complete all as specified and directed.Note : Spares required for replacement will measured and paid separately under respective items here-in-after of this schedule. |
| 67 | M& L for Replacement of water solenoid as per existing and suitable size complete all as specified and directed. |
| 68 | M & L for Replacement of steam solenoid as per existing and suitable size complete all as specified and directed. |
| 69 | M & L for Replacement of drain assembly valve as per existing and suitable size complete all as specified and directed. |
| 70 | M & L for Replacement of Temperature sensor probe as per existing size complete all as specified and directed. |
| 71 | M & L for Replacement of Relay card with base 8pin 230V as per existing capacity complete all as specified and directed. |
| 72 | M & L for Replacement of Power supply (SMPS) 4-5 Amps as per existing complete all as specified and directed. |
| 73 | Taking down the main bearing housing assembly in drum for replacement of bearings and re-fixing the same with necessary connected items complete all as specified and directed. |
| 74 | M & L for Replacement of front and rear bearings in drum as per existing size complete all as specified and directed. |
| 75 | M & L for Replacement of oil seal as per existing size complete all as specified and directed.. |
| 76 | M & L for Repair/Replacement of VFD by new controller relay system box with IGBT as per existing and suitable size complete all as specified and directed. |
| 77 | Taking down the electrical panel of machine & taking out old/unsv parts and wires and rewiring the same with new cables/wires & re-fixing the panel in machine complete all as specified and directed. |
| 78 | Taking down electrical motor and servicing & rewinding the same and re-fixing in machine complete all as specified and directed. |
| 79 | M & L for Foundation work as required for no vibration during operation of machine complete all as specified and directed. |
| 80 | M & L forRepair to Drying tumbler of cap 30kg by disconnecting electrical and steam connection for overhauling and servicing of machine, balancing of inner basket, replacement of old/rusted parts. (as follow from item No 81 to 86) complete all as specified and directed.Note : Spares required for replacement will measured and paid separately under respective items here-in-after of this schedule. |
| 81 | M & L for Replacement of steam solenoid as per existing sizecomplete all as specified and directed. |
| 82 | M & L for Replacement of steam radiator as per existing size complete all as specified and directed. |
| 83 | M & L for Replacement of ball bearing assembly of main and counter housing as per existing size complete all as specified and directed. |
| 84 | M & L for Replacement of door gasket as per existing size complete all as specified and directed. |
| 85 | Taking down the electrical panel of machine & taking out old/unsv parts and wires and rewiring the same with new cables/wires & re-fixing the panel in machine complete all as specified and directed. |
| 86 | Taking down electrical motor and servicing & rewinding the same and re-fixing in machine complete all as specified and directed. |
| 87 | M & L for Complete overhauling and servicing of Flat work ironer and chest buffing by taking down the chest of machine and re-fixing the same for smooth function of machine and replacement of following parts from Item No 88 to 95 complete all as specified and directed.Note : Spares required for replacement will measured and paid separately under respective items here-in-after of this schedule. |
| 88 | M & L for Replacement of polyester padding as per existingcomplete all as specified and directed. |
| 89 | M & L for Replacement of Pneumatic cylinder kits as per existing complete all as specified and directed. |
| 90 | M & L for Replacement of steam solenoid valve as per existingcomplete all as specified and directed. |
| 91 | M & L for Replacement of air solenoid valve as per existing complete all as specified and directed. |
| 92 | M & L for Replacement of air filter with lubricator as per existing complete all as specified and directed. |
| 93 | M & L for Replacement of steam hose pipe as per existing complete all as specified and directed. |
| 94 | M & L for Replacement of air hose pipe as per existing complete all as specified and directed. |
| 95 | M & L for Replacement of temp. controller with sensor probe as per existing complete all as specified and directed. |
| 96 | M & L for Overhauling and servicing of steam boilerand repair to boiler jacket and tank by replacement of old/rusted parts from item No 97 to 99 for the better performance and function complete all as specified and directed.Note : Spares required for replacement will measured and paid separately under respective items here-in-after of this schedule. |
| 97 | M & L for Replacement of electric heater as per existing size and capacity complete all as specified and directed. |
| 98 | M & L for Replacement of temp. controller with sensor probe as per existing complete all as specified and directed. |
| 99 | M & L for Replacement of main contactor in electric panel as per existing capacity complete all as specified and directed. |
| 100 | M & L for Painting of Machines by providing two coat of super enamelled paint over a coat of red oxide and scratching out old paint for the following equipments complete all as specified and directed.Washer Extractor 60kg - 01 no.washer extractor 30Kg- 01 no. Drying tumbler 30kg - 02 nos. Flat work ironer- 01 no. Steam Boiler - 01 no. |
| 101 | M & L for Repair/ Servicing of Air Compressor complete all as specified and directed. |
| 102 | M & L for concealed sub main wiring complete with PVC insulated FRLSH cable of 4 run of single core 10 Sqmm 1100 volts grade with unseathead multistranded copper coductor (for phase and neutral)drawn through and including PVC med grade conduit with accessories and 1 run of 10 sqmm 1100 volts grade with unseathead multistranded FRLSH copper coductor (for earthing) complete all as specified and directed. (Note :- (a) four run of 10 Sqmm multistranded FRLSH copper conductor and one run of 10 Sqmmmultistranded FRLSH copper conductor and one run of 25 mm dia med grade PVC conduit shall be measured adn paid as one run length. Colour coding for wiring shall be followed as per direction of Engr-in-Charge. (b) The rate quoted by contractor shall be included for chess cutting of the existing wall/surface for concealed wiring and making good the disturbed surfaces to match with the existing wall/surfaces) |
| 103 | M & L for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6mm thick burried directly in ground not less that 2.25 m deep below normal ground level and top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI strip of size 25 x 4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical palte No 3 connected to earthing test point incl excavation, earth work in any type of soil strata, PCC chamber, 40 mm dia GI med grade pipe as protection of strip and 15 mm dia GI Med grade watering pipe, funnel, wire mesh etcincluding testing on complete all as specified and directed. |