| 1 | Surface dressing n exc 15 cm deep and getting out in soft /loose soil, complete all as specified and directed. |
| 2 | Excavation in trenches not exc 1.5 m wide and n.exc 1.5m in depthfor foundations soft/loose soil, complete all as specified and as directed. |
| 3 | Returning, filling in spreading and levelling and well ramming in layers not exc 25cmincluding wateringfor filling under floor, complete all as specified and as directed. |
| 4 | Removing of excavated material (soils, etc) to distance n.exc 50 M and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed. |
| 5 | M&L for hardcore (broken stone or boulders) of gauge n exc 63 mm deposited, spread and levelled in layers n. exc 15 cm thick watered and rammed to true surface, complete all as specified and as directed. |
| 6 | M&L for PCC (1:5:10) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 7 | M&L for reinforced cement concrete Type(Nominal mix) A1 1:11/2:3 (using 20mm graded stone aggregate)as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, etc and mass concrete, complete all as specified and directed. |
| 8 | M&L for reinforced cement concrete (Nominal mix)A1 1:11/2:3(using 20mm graded stone aggregate)as in Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 9 | M&L for reinforced cement concrete(Nominal mix)A1 1:11/2:3(using 20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span,complete all as specified and directed. |
| 10 | M&L for (Nominal mix) A1 1:11/2:3(using 20mm graded stone aggregate) as in slabs supported on walls etc, complete all as specified and directed. |
| 11 | Formwork to Square, rectangular or polygonal rough surface of concreteof sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed. |
| 12 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and directed. |
| 13 | Formwork to chullah hoods, chajjas, troughs and similar items including edges, complete all as specified and directed. |
| 14 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 15 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed. |
| 16 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spiarally for hooping for columns, plinth beam etc, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 17 | S&F of 5 mm dia and over upto including 10mm dia in stirrups, spacers and binder, complete all as specified and directed. |
| 18 | M&L for brick work with sub class \"B\" bricks, straight or curvedon plan exc 6m mean radius, built in CM 1:6, complete all as specified and directed. |
| 19 | M&L for brick work with sub class \"B\" bricks , straight or curvedon plan exc 6m mean radius, built in CM 1:4 (half brick wall), complete all as specified and directed. |
| 20 | M&L damp proof coarses in cement concrete1:2:4 type B-0 (using 12.5mm graded stone aggregate) 40mm thick including necessary form work complete all as specified. |
| 21 | M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in sub floor to receive any type of floor finish, tiles etc, complete all as specified and directed. |
| 22 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in sub floor to receive any type of floor finish, tiles etc, complete all as specified and directed. |
| 23 | M&L for 75 mm thick PCC as in plinth protection and path type C-2 1:3:6 (20 mm graded agg) finishing cement surfaces even and smooth with out using extra cement complete allas spd & directed including making of joints at every 2.5 mtr and at corner fillled with mastic filling with bitumens 85/25 and sand in ratio 1:2 by weight, complete all as specified and as directed. |
| 24 | M&L for rendering 10mm thick plaster in CM 1:6 onbrick or concrete surfaces,complete all as specified and as directed. |
| 25 | M&L for 15mm thick rendering on fair faces of brick or concrete surface in Cm (1:4) and providing in two layers, with WPC @ 3% of cement and finishing even and smooth without using extra cement, complete all as specified and directed. |
| 26 | M&L for rendering 5 mm thick in CM 1:3 as in ceiling, complete all as specified and directed. |
| 27 | M&L for Non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular)area of each tiles exceeding 0.06 sqm but n.exc 0.11sqm in floor etc,over 15 mm thick screed bed in CM(1:6),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces, complete all as specified and directed. |
| 28 | M&L for glazed ceramic coloured tiles in vertical surface 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match. complete all as specified & directed incl rendering 10mm thick in CM (1:4) and finished rough. |
| 29 | M&L for two coat of oil boundemulsion distemper including prepration of new plastered surface of wall over a coat of primer, complete all as specified. |
| 30 | M&L for three coat of white washing on ceiling including preparation of surfaces, complete all specified and as directed. |
| 31 | M & L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over one coat of alkali resistantprimer, complete all as spd & directed. |
| 32 | M&L for Liquid water proofing compound as per latest IS specification, complete all as specified and directed. |
| 33 | S&F of Vitreous China cascade type wash down water closet pan(one piece type), white with soft seat cover,fixing accessories incl cistern fitting, flushing cistern and flush pipe \"P\" or \"S\" trap etc. all as specified and as directed.(Make : jaquar CNS -WHT-757NS 300SPPZ or equivalent in Cera/Hindware as approved. |
| 34 | S&F for vitrious china wash basin, white size 600x400x185 mm counter typeas per catalouge,SLS-WHT-6601 Make- Jaquar or equivalent series in hindware or parryware complete fixed in counter opening of granite platform and supported overbracket etc. including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium platedetc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including bottle trap fitted, complete all as specified and directed. |
| 35 | S&F of 15 mmfancytype pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered ‘Hot’ or ‘cold’ with long screwed shanks and fly nuts, all as specified and directed by Engr-in-charge. Make : Jaquar CON -021KN or equivalent in Cera/Hindware as approved. |
| 36 | S&F of 15 mm fancy/concealedtypestop valve cast copper alloy chromium plated screwed high pressure with crutch or butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube, complete all as specified and directed by Engineer-in-Charge. |
| 37 | S&F (in repairs) Bib taps cast copper alloychromium plated fancy type with crutch or butterfly handle screw down ,screwed for iron pipe or or brass ferrule for 15 mm bore of pipe, complete all as specified and as directed. Make : Jaquar CON -037KN or equivalent in Cera/Hindware as approved. |
| 38 | S&F of 15 mmstop valve cast copper alloy chromium plated fancy type screwed high pressure with crutch or butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube, complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for brass chromium plated tubular towel rail 20mm dia D type 600 mm long between flanges fixed, complete all as specified and directed. |
| 40 | S&F of Bevelled edge mirror of size 600x450mm of selected quality glass 4mm thick mounted on 6mm thick AC building board or commercial ply wood and fixed with wooden plugs with chromium plated screws, complete all specified and as directed. |
| 41 | S&F of PVCconnection pipe 45 cm long with PTMT fixedto WHB, flushing cistern an complete all as directed at site. |
| 42 | S & F for Soap dish, any type, fixed to plugs with chromium plated brass screws, complete all specified and as directed. |
| 43 | S&F of Toilet paper holder of chromium plated fixed to walls with chromium plated (CP) brass screws, complete and all as specified and directed. |
| 44 | S&F ofshower rose 125 mm brass chromium plated with swivel joints, complete and all as specified and directed. |
| 45 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete and all as specified and directed. |
| 46 | S& F in repairs Brass CP mixer 15mm Dia for mixing hot & cold water, screwed down, three joints to steel pipes or unions and plugging and screwing to walls,complete all as specified and directed. Make :Cera QTF2006401HT F3001401 or equivalent in Jaquar or Hindware as approved. |
| 47 | S & F of glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm, complete all specified and as directed. |
| 48 | Cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing ,steps cills, sunshades, shelves ,lintels etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good ,cutting not exc. 10 cms girth complete in brick walls, complete all specified and as directed. |
| 49 | S&F of GI tubing medium grade with all fitting and fixed to wall ,ceiling or laid in floor etc complete of 15 mm bore pipe, complete all specified and as directed. |
| 50 | All as per item No49.00above but20 mm bore,complete all specified and as directed. |
| 51 | S&F of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia GI tube, complete all specified and as directed. |
| 52 | S&F of rotational moulded polethylene water tank of 1000 ltrs capacity (cylindrical vertical with closed top) hoistedand fixed in position all as pacific SSR Part- I, complete all as specified and directed. |
| 53 | S&F of PVC(SWR) 75mm bore pipes single socketed in any length with rubber ring joints fixed to walls/floor, complete all specified and as directed. |
| 54 | S&F of 110mm PVCsoil waste and vent pipes in any length with or with out ears with cement joints, fixed to wall, complete all specified and as directed. |
| 55 | S & F of PVC (SWR) bend 110mm bore, complete all specified and as directed. |
| 56 | S & F of PVC (SWR) bend 75mm bore, complete all specified and as directed. |
| 57 | Supply and laying double wall corrugated DWC pipe HDPE pipe of outer dia 150mmof approved make ISI marked polythene with smooth internal wall & profiles external surfaces for non pressure for sewage, complete all specified and as directed. |
| 58 | Supply and fixed of PVC (SWR) vent cowl, 100mm dia, complete all specified and as directed. |
| 59 | M&L for concrete bed to drain pipe including packing under and haunching against the side and pipe of 150mm bore in cement concrete 1:3:6 type C2 after they laid and tested, complete all specified and as directed. |
| 60 | S&F ofGrating doom 125 mm dia with waste hole of PTMT Minimum weight 40 gms, complete all as specified and directed. |
| 61 | S&F of 75mm PVC (SWR) floor trap(S/P), plain with grating including jointing with solvent cement, complete all specified and as directed. |
| 62 | S&F of stack clamps out of 50mmby 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall pipe, complete all as specified and directed. |
| 63 | S&F of 110 mm borebends PVC (any radius) with oval access doors ISI marked, complete all specified and as directed. |
| 64 | S&F of solid PVC door frame of size 50mmx47mm thick made out of 5mm thick plain colour PVC sheet reinforced with M.S Sqare tube, single side prelam PVC sheet used instead of plain colour PVC sheet edges will be painted to match with prelam sheet, complete all specified and as directed. |
| 65 | S&F of factory made solid panel PVC door shutter28 to 30mm thick (style)with 2,4 or 6 raised panel design with 2mm thick moulded pvc sheet on the front face and 2mm plaib colour PVC sheet on the back face , supplying and fixing in frame atat site as per specification and SSR Part-1, complete all specified and as directed. |
| 66 | S & F of Anodised aliminium window and ventilators shutters, side hung type ithout sash bars, aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips rubber packing anodised aliminium snap beading screws anodised aluminiumfitting such as peg stays 150mm long(1no)hinges type B-21 100mm long (2 No) hinges type B-21 100mm long (2no) suitable handles(1no), complete all specified and as directed. |
| 67 | S&Fof 100 mm long aluminum anodized barrel tower bolt extruded section, complete all specified and as directed. |
| 68 | S&F of aluminum handles cast type anodize 150 mm long, complete all specified and as directed. |
| 69 | S&F of extruded aluminium alloy butt hinges 100mm size type B-21, complete all specified and as directed. |
| 70 | S & F of curtain rods of anodised aluminium alloy with fixing brackets, stops, roller etc in repairs, complete all specified and as directed. |
| 71 | S&F of galvanised steel wirecloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mmin repairs, complete all as directed at site. |
| 72 | S&F of figured glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane thickness of glass 3mm thick, complete all specified and as directed. |
| 73 | S&F inMS sliding door bolts 300mm long plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bold plate and two on staple plate and fixed, complete all as specified and directed. |
| 74 | M&L for Sand filling under floors/ paver block or in foundationincluding watering and consolidation, complete all as specified and directed. |
| 75 | M&L for colouredmachine pressed rubber moulded precast conctete interlocking paver blockany shape and any size confirming to IS 15658-2006 of 80mm thickness, M-35 grade,complete all as specified and directed. |
| 76 | M&L for chequered cement concrete tiles (coloured) 20cm x 20cm x 25mm thick, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors, complete all as specified and directed. |
| 77 | M&L for PCC 1:2:4, type B1, using 20mmgraded stone aggregate asin kerbs, mudstops, rounded or chamfered on edges and similer work, complete all as specified and directed. |
| 78 | M&L for precast cementconcrete 1:2:4 type-B1 as in landings, cover slabs (for manholes etc) Chula hoods, chajjas, water through managers shelves and similar articles with plain faces set in cementmortar 1:4, complete all as specified and directed. |
| 79 | M&L for rendering 10 mm thick in CM 1:3, mixed with water proofing compound, on concrete surfaces of roof, surface finished even and smooth, complete all as specified and directed. (supply only of water proofing compound shall be measured and paid seperately) |
| 80 | M&L for applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm, complete all as specified and directed. |
| 81 | M&L for two coat of aluminium paint on APP based polymeric water proofing membrane 0.1 ltr/sqm in each coat including prepartion of surface of roof etc, complete all as specified and directed. |
| 82 | M & L for APP basedpolymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS),laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer. |
| 83 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI markedand including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches, socket outlet and fan regulators etc, complete all as specified and as directed for the followings:- |
| 84 | (a)One light/fan/bellpoint controlled by one switch single pole one way, complete all as specified and directed. |
| 85 | (b) All as per item No 83.01here-in-before butone3 pin 6 amp switch socket out let independent, complete all as specified and directed. |
| 86 | All as per item No 83.02 here-in-before but using 02 Nos. 2.5 sq mm size for main cable and 01 No.2.5 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board, complete all as specified and directed. |
| 87 | Supply and fixing of switch modular flush 10A single pole one way ISI marked, complete all as specified and directed. |
| 88 | Supply and fixing of modular sockets 10 Amp 2 in 1 2/3 pin combined, complete all as specified and directed. |
| 89 | Supply and fixing of switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked, complete all as specified and directed. |
| 90 | Supply and fixing ofmodular sockets 16Amp 2 in 1 3/5pin combined, complete all as specified and directed. |
| 91 | Supply and fixing of ceiling rose surface bakelite 60x25mm three terminal, complete all as specified and directed. |
| 92 | Supply and fixing ofLED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 93 | S&F of LED batten extruded surface mountingfitting 2 feet long aluminium housing 10 wattinput voltage 220 volt inbuilt LED and driver, complete all as specified and directed. |
| 94 | Supply and fixing of Ventilating Fan250 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of making holes and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan, completeall as specified and as directed. |
| 95 | S & F of LED light fitting 10 Watt bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 96 | Supply and fixing of connecting and testing LED street light 35 watt 6000k/3000k new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high efficient led as lighting source and PC cover having toP opening seperate driver compartment with IP66 protection and impact resistance of IK07 roadway luminaries with high power LED as light source and electronic driver complete with connection and accessories for fixing with with including grade 40mm dia GI pipe as bracket in appropriate length complete including taking down old light fitting. |
| 97 | Supply & fixing of MCB DB SPN 8 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting, completeall as specified and directed. |
| 98 | Supply and fixing of MCB, single pole and neutral, 230 volts, 32 Amp rating, \"C\" series fixed in DBs catered here-in-before, completeall as specified and as directed. |
| 99 | Supply and fixing of MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve, complete all as specified and directed by Engineer in Charge. |
| 100 | Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning, complete all as specified and dierected |
| 101 | Supplying, laying sub class \"B\" bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection, complete all as specified and directed. |
| 102 | Supply & Fixingin replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia, complete all as specified and directed |
| 103 | Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable under ground cable with 1100 volts grade with stranded aluminium conductor of sizes 10 Sqmm 4 core, completeall as specified and as directed. |
| 104 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. |